Uric Acid (Uod -Pap) - Colorimetric Enzyme Method For The Determination Of Uric Acid. Enzyme Reagent: 02 100 Ml Vials Each, Aqueous Solution Containing Ph 7, 20, Uricase ³ 120 U/L, Peroxidase ³ 1000 U/L, 4-Aminoantipirin 1, 0 Mmol/L, 0, 60 Mmol/L And Azidasod 0, 1 G/Dl. Conserve Between 2 And 8 ° C. Standard: 01 Phrascocom 5, 0 Ml, Containing Uric Acid 8 Mg/Dl (0, 476 Mmol/L) In Aqueous And Azidal Sodium Solution 0, 1 G/Dl. Conserve Between 2 And 8 ° C. Validity At Least 18 Months. Kit. Note: Compatible With The Sinnowasx260 Automatic Biochemical Analyzer., Albumin - Monoreagent Kit For The Determination Of Albumin In The Serum. With Pattern Included In The Kit, Methodology: Green Bromocresolsensitivity: 0, 27 G/Dl, Linearity Of: 6 G/Dl, Presentation: R1 1X250ml + Std 3Ml, Linearity Up To 6G/Dl. 250Ml Mime Quantity. Note: Compatible With Automatic Analyzer Sinnow Sx260., Alpha-1 Glycoprotein Acid-Kit Intended To Determine The Alpha-1 Glycoprotein Acid In Serum And Plasma. Methodology: Turbidimetry; Sensitivity: 1, 55 Mg/Dl; Linearity Of: 250 Mg/Dl; Presentation: R1 1 × 25Ml. Note: Compatible With The Biochemical Analyzer Sinnow Sx260., Alt -Tgp - Kit For Quantitative Determination Of Tgp Activity In The Serum. Methodology: Uv - No Pyridoxal Phosphate. Sensitivity: 5.15 U/L, Linearity Of: 350 U/L, Presentation: R1: 4X40ml And R2: 4X10ml. Minimum Amount Of 200Ml. Note: Compatible With Automatic Analyzer Sinnow Sx260., Ast -Tgo - Kit For Quantitative Determination Of Tgo Activity In Serum. Methodology: Uv - No Pyridoxal Phosphate, Sensitivity: 3.05 U/L, • Linearity Of: 440 U/L. Presentation R1: 4X40ml And R2: 4X10ml. Minimum Amount Of200ml. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer. Methodology: Dca (Dicloroaniline Diazoted). Reaction: Final Point. Presentation R1 1X80ml + R2 2X12ml Linerality. At Minimum 50Mg/Dl. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer., Total Bilirubin - Kit Intended For The Determination Of Total Bilirubin In Serum And Plasma (Heparin And Edta). Methodology: Dca (Dicloroaniline Diazoted). Reaction: Final Point. Presentation R1 1X80ml + R2 2X12ml Linerality. At Least 20Mg/Dl Note: Compatible With The Sinnowasx260 Automatic Biochemical Analyzer. Methodology: Galg2 - Cnp, Sensitivity: 3.167 U/L, Linearity Of: 1200 U/L, Presentation: R1: 4X15ml. Minimum Amount Of 60Ml. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer., Calcium Asx - Monoreagent Kit For The Determination Of Calcium In Serum, Plasma And Urine. With Pattern Included In The Kit. Methodology: Arsenazo Iii. Sensitivity: 0.94 Mg/Dl, Linearity From: 20 Mg/Dlapress: R1: 4X50ml +Std 1X4ml. Minimum Amount Of 200Ml., Iron Fixation Capacity (Ibc) - Kit Intended To Determine The Iron Fixing Capacity In The Serum. Automated Method, Final Point Reaction. Compadrão Included In Kit. Volume: R1 2 × 50Ml - R2 2 × 15Ml - Cal 1 × 3Ml. Linearity: 450 Μg/Dl. Minimum Quantity Of130ml. Note: Compatible With The Sinnow Sx260 Automatic Biochemical Analyzer., Kit Intended For The Quantitative Determination Of The Activity
|