Quotation Are Invited For Ceramic Coating On Chiller Condenser Tube Sheets And End Covers Water Boxes1032201292 Carrier Wc Chiller Maintrfx DescriptionCeramic Coating On Chiller Condenser Tube Sheets And End Covers Water Boxes For 3 Nos Of Carrier Water Cooled Chillers At Al Quoz Sustainable Building As Per The Attached Specification Contact Person For Site Visit Mr Akbar Ali 052 8682151 And Mr Mohideen 055 3810513 04 3227879 1 Item 00001 Ceramic Coating On Chiller CondenserTube Sheets And End Covers Water BoxesFor 3 Nos Of Carrier Water Cooled ChillersAt Al Quoz Sustainable Building A Scope Of Works The Contractor Is Required To QuoteLump Sum Price For Ceramic Coating OnCondenserTubes End Covers And Water Boxes For 6Nos Of Trane Water Cooled Chillers TheQuotation Will Be Submitted As Per DewaSpecificatIon And Survey Only Contractor ShallVisit The Site And Take NecessaryMeasurement And Connections As PerExisting Conditions Contractor To Arrange Crane And RiggingTo Remove And Fix The End Covers As PerSite Requirement Dismantling The EndPlates DrYing The Tube Sheet And Flash Out AnyWater Contents Inside The Tubes Using AirBlower Covering The Chiller Using Tarpaulin To MiNimize Dust Plugging The Tubes Of ChillerCondenser Tube Sheets Using Plug GritBlasting The Chiller Condenser TubeSheets And End Covers To Sa 2 1 2 Standard RebuildThe Pitted Area On The Tube Sheet And EndCovers With Metal Putty TheEroded Pitted ArEa Only On Tube Sheets And End Covers OfChiller Condenser Will Be Filled RebuildWith Metal Putty Resimac 101 Apply2 Coat SYstem Of Ceramic Coating Material On TubeSheet And End Covers Apply Two CoatSystem Of Ceramic Coating Material Resimac 203 BoTh On Tube Sheets And End Covers OfChiller Condenser At 500 Micron DftMinimum Cary Out Pin Hole Holiday TestOn End Coavers ONly Using Elcometer Positector CaryOut Thickness Test To 500 Micron Dft Minimum Using Elcometer Positector Remove The PluGs Cleaning The Area Fix Back TheCondenser Water Boxes CommissioningThe System And Final Testing Under ThePresence Of Dewa Supervisor Engineer Contractor To HandOver The Cooling Towers In WorkingCondition Testing Installing AndCommissioning TheComplete System As Per Existing SiteRequirements And ManufacturesRecommendation The Job Execution ShallBe Carried Out In The TIming Assigned By The Dewa Engineer TheContractor Is Required To Take AllPrecaution So As Not Damage Any Of TheExisting EquipmEnt Structure Etc Contractor Staff IsRequired To Wear Proper PersonalProductive Equipment At All Times InsideThe Premises AlL Health And Safety Measures Signboards Fire Blanket Fire Extinguishers Etc To BeFollowed Up Strictly Contractor Has ToProviDe Material Submittal Method Statement And Schedule Of Work To The Engineer ForApproval Before Carrying Out TheInstallation IN Case Of Un Satisfactory Performance The Lpo Will Be Cancelled Giving 15 Days Notice Contact Person For Site Visit Mr Akbar AlI 052 8682151 And Mr Mohideen 055 3810513 043227879 B General Condition MobilizationAt Site Of The Contract Spare PaRts Required To Carry Out TheRectification Activity Should Be ArrangedAt The Earliest In Order To Keep TheEquipment Down Time ToMinimum And Must Be Genuine Spares FromOem Or Oem Recommended Vendors AllThe Materials In General Will Conform AsPer Latest StAndards And Shall Be Submitted To Dewa For Engineers Approval The ContractorIs Required To Take All Precaution So AsNot DamagE Any Of The Existing Equipment StructureEte The Contractor Shall Deploy TheSkilled Technicians For Carrying Out TheWorks Should We Experience A Breakdown In AnyOf Equipment System At Any Time Of The DayOr Night You Will Respond To Our RequestWith YoUr 24 Hours Emergency Call Out SystemAvailable 7 Days A Week Responding Time ToBreakdown Calls Is Within 1 Hour AfterReceipt OfNotification All Activities Shall BePerformed In Presence Supervision OfCompetent Supervisor Contractor ShallObtain All NeCessary Approvals Clearance FromConcerned Dewa Engineer SupervisorBefore Commencing Any MaintenanceActivities Supervisor Shall Be Responsible For The Safety Of Men Equipment During The Activities And AlsoMust Ensure That Work Executed Is OfHighest StandaRd Contractor Shall Take Care Of AllRelated Formalities Like Mobilization OfStaff Ensuring Tools Test Equipment SAre AvailaBle At Site For Carrying Out The CorrectiveMaintenance Activities Transportation OfStaff From To Site Shall Be Arranged ByTheContractor Dewa Will Not Accept AnyClaim For Extras Beyond The Order PriceDuring And After The Execution Of Work Unless ClaimWith Proper Justification Is Approved ByDewa Management Contractor Shall BeResponsible For Any Discrepancies OrDamages Of TheExisting System During Execution Of TheWork Contractor Must Execute AllRelated Works Required For The Safe Execution Of MainteNance Activity Even Though Not MentionedExplicitly In The Order Covid 19Precaution Measures To Be Followed AsPer Dewa Health Safety Department Recommendation UntilFurther Notice Contractor Staff IsRequired To Wear Proper PersonalProtective Equipment At All Time On The Site C SafteyPrecaution Site Cleanliness Area OfWork Shall Be Kept Clean Clear At AllTimes During And After The Work If Any WasteGenerated Then It Should Be Cleaned AndDisposed Immediately Contractor MustEnsure That All STaff Inside Dewa Premises Shall FollowDewa S Safety Environment Rules AndRegulations Welding Flame Heating OrCutting GrindIng Pneumatic Chipping Etc Shall BeCarried Out Without Specific Clearance From Dewa All Such Activities Will BeCarried Out ThroUgh Hot Work Permits Hot Work Permit IfRequired Shall Be Obtained On Daily Basis Contractor Shall At No Time KeepInflammablE Substances In The Plant Work Areas ButIn Case Such Items Are Required For TheActivity Then All Required Permission MustBe ObtAined From Concerned Authorities Workmen Shall Wear All Necessary PpesLike Uniform Safety Shoes And Helmet AtWork Site AllAdjoining Plant Installation Instruments Electric Cables And Cubicles Shall BeAdequately Protected During Execution OfAny MainteNance Activities Rigging Tools TacklesWith Valid Test Inspection CertificatesFrom 3Rd Party Shall Only Be Used By TheContraCtor D Terms Of Payment Payment Will Be Made After Completion Of The Work Invoice Shall Be Addressed To Our FinanceDeparTment Along With Completion Of Reports E Warranty Five 5 Years Warranty ForCeramic Coating And Workmanship TheWarranty Will Take Effect From The Date OfTakeover By Dewa On The Job Carried Out ByThe Contractor F Penalty Clause InCase ContraCtor Due To His Fault Fails To Complete TheJob In Time As Per Given And AgreedSchedule Then Contractor Is Liable To Pay1 25 Of The Job Value As Penalty For Every WeekOf Delay With A Maximum Ceiling Of 10 InCase Contractor Fails To Keep The ActivitySchEdule In Progress Then Dewa Will TakeOver The Work And Execute It The Way ThatMay Feel Right To Meet The Time Schedule The Expenditure Incurred Will Be Back Charged ToThe Contractor G Documents OnSatisfactory Completion Of Each Activities A Detailed FAct Finding Report In English Shall BeSubmitted Which Will Cover Root CauseAnalysis Observations RecommendationsAnd ConfirmatIon Of Equipment Fitness Based On The TestResults 3 EaStandard Terms Conditions1 Prices Should Be Ddp Delivery Duty Paid At Dewa Stores 2 Quotation To Be Submitted Only In Local Currency U A E Dirhams3 Dewa Standard Payment Terms Is 30 Days Credit From The Date Of Acceptance Of Material4 No Dewa Staff Or His Or Her Relatives Up To Third Degree Should Have Ownership Or Partnership In Your Company And Your Participation In Dewa Tenders Rfqs Should Not Constitute A Conflict Or Perceived Conflict Of Interest
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 50714403
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.