Roll Sterilization Bag Designed For Plasma Sterilizers Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). Thermo-Sealable Packaging Rolls Are Used In Human Meditek Plasma Sterilizers And Are Intended For Packaging Medical Products With Subsequent Long-Term Storage After Sterilization. The Bags Are Made Of Polyethylene, Polyester And Special Material That Allows The Sterilizing Agent To Pass Through. Roll Size - 75 Mm × 70 M, Material Thickness - 240 Microns. Material: Front Side - Transparent Ldpe, Back Side - White Tyvek®. Sealing Temperature: 115–130 °C. Storage Conditions: Temperature 25±5 °C, Relative Humidity 50±5%. Intended Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek., Roll Sterilization Bag Designed For Plasma Sterilizers Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). Thermo-Sealable Packaging Rolls Are Used In Human Meditek Plasma Sterilizers And Are Intended For Packaging Medical Products With Subsequent Long-Term Storage After Sterilization. The Bags Are Made Of Polyethylene, Polyester And Special Material That Allows The Sterilizing Agent To Pass Through. Roll Size - 100Mm × 70 M, Material Thickness - 240 Microns. Material: Front Side - Transparent Ldpe, Back Side - White Tyvek®. Sealing Temperature: 115–130 °C. Storage Conditions: Temperature 25±5 °C, Relative Humidity 50±5%. Intended Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek., Chemical Indicator - 55 M Long Tape, Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). Chemical Indicator Tape Is Intended For Use In Human Meditek Plasma Sterilizers, Has An Adhesive Base And Is Used For Gluing To The Outside Of Packaging Intended For Sterilization. During The Sterilization Process, Upon Contact With Hydrogen Peroxide Vapor, The Indicator Tape Changes Color From Red To Yellow, Confirming The Completion Of The Sterilization Cycle. Development Time Is 30–60 Minutes. Tape Dimensions: Length 55 M, Width 19 Mm. Shelf Life - Up To 2 Years From The Date Of Production. Storage Conditions: At Room Temperature 15–30 °C In A Dry Room At A Relative Humidity Of 20–80%, Excluding Exposure To High Temperature, High Humidity, Sterilants And Direct Sunlight. Intended Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek., Roll Sterilization Bag Designed For Plasma Sterilizers Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). Thermo-Sealable Packaging Rolls Are Used In Human Meditek Plasma Sterilizers And Are Intended For Packaging Medical Products With Subsequent Long-Term Storage After Sterilization. The Bags Are Made Of Polyethylene, Polyester And Special Material That Allows The Sterilizing Agent To Pass Through. Roll Size - 150Mm × 70 M, Material Thickness - 240 Microns. Material: Front Side - Transparent Ldpe, Back Side - White Tyvek®. Sealing Temperature: 115–130 °C. Storage Conditions: Temperature 25±5 °C, Relative Humidity 50±5%. Intended Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek., Neutral Enzymatic Agent Is Intended For Cleaning And Disinfection Of Medical Instruments In Washing And Disinfection Machines. Provides Effective Removal Of Organic Contaminants Due To The Action Of Enzymes And Surfactants And Does Not Require Subsequent Neutralization. Used In A Concentration Of 5–10 Ml/L (0.5–1%) At A Temperature Of 45–60 °C With An Exposure Of At Least 5 Minutes; Dosing Is Carried Out At A Temperature Of 35 °C. For The Treatment Of Instruments, A Dose Of 2–5 Ml/L In Deionized Water Is Allowed. A Two-Stage Cleaning Mode Is Possible Without Intermediate Draining Of The Solution: The First Stage Is 5-10 Ml/L At 45 °C For 3 Minutes, The Second Stage Is At 60 °C (Or 58 °C For Heat-Sensitive Invasive Devices) For 3 Minutes. The Ph Value Of A 1% Solution Is About 9.8 In Demineralized Water And About 7.2 In Tap Water, The Density Of The Concentrate Is About 1.1 G/Ml. The Concentrate Is A Transparent Yellow Liquid. The Composition Includes Nonionic And Amphoteric Surfactants, Enzymes, Phosphates And Polycarboxylates (Each Component Less Than 5%), As Well As An Active Substance Of The Amine Oxide Class With A Mass Fraction From 1% To Less Than 5%. The Product Is Suitable For Processing Products Made Of Stainless Steel, Anodized Aluminum, Titanium, Non-Ferrous Metals, Plastics, Elastomers, Silicone, Rubber, Latex, Ptfe, Glass And Ceramics, And Is Biodegradable. Products Must Meet The Requirements For Medical Devices And Be Registered In The Eaeu. Release Form: 5 Liter Canister. The Product Is Subject To Mandatory Prior Approval With The Customer And Must Be New And Undamaged. Delivery And Acceptance Are Carried Out Only On Working Days And Working Hours. In Case Of Non-Compliance With The Specifications, The Supplier, At Its Own Expense, Ensures Reconfiguration Of The Washing Machine And Repair Of Equipment Or Processed Products., Sterilizer, Bottle No More Than 130 Ml, Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). Contains Hydrogen Peroxide (H₂o₂), Intended For Use In The Plasma Sterilization System For Medical Equipment Of A Wide Range Of The Hma Line Manufactured By Human Meditek. The Diameter Of The Bottle Is No More Than 8 Cm, The Height Is No More Than 12.1 Cm. The Bottle Material Is Plastic, The Lid Is Black Plastic. The Bottle Is Equipped With A Protective Cap On The Bottom Side With A Height Of No More Than 3.4 Cm And A Diameter Of No More Than 2 Cm. There Is An Individual Id Number Of The Bottle For The Hma Series Plasma Sterilizer. The Concentration Of Hydrogen Peroxide Is No More Than 50%. Shelf Life: No Less Than 18 Months At A Temperature Of 2–8 °C, No More Than 10 Months At Room Temperature, Use In The Device No More Than 45 Days., The Acid Neutralizer And Pre-Cleaner Are Intended For Use In Washer-Disinfectors Of The Central Sterilization Unit After Weakly Alkaline Or Alkaline Machine Cleaning. The Product Is Used To Neutralize Alkaline Residues, Remove Acid-Soluble And Lime Deposits, Prevent The Formation Of Stains And Damage To Materials During Subsequent Sterilization, As Well As To Clean The Loading Compartments Of Washing Machines And Washing Conveyors. Can Be Used For Processing Surgical Instruments Made Of Stainless Steel; Use For Tools Made Of Aluminum And Zinc Is Not Permitted. The Ph Of A 1% Solution In Demineralized Water Is About 2.3. The Concentrate Is A Transparent Liquid From Colorless To Light Yellow, Density About 1.07 G/Ml. Composition: Inorganic Acid With A Mass Fraction Of At Least 1% And Less Than 5%, (Ethylenedioxy)Dimethanol - Less Than 5%. Release Form - Canister Weighing 5 Kg (Volume About 4.7 L), Approximate Dimensions: Width 24 Cm, Height 20 Cm, Depth 12 Cm, Neck Diameter About 5 Cm. The Product Must Have Registration And Permits In The Territory Of The Customs Union (Eaeu) And Comply With Current Regulatory Requirements. The Product Is Subject To Mandatory Prior Approval With The Customer, Must Be New, Without Damage Or Damage To The Integrity Of The Packaging. If Any Discrepancies Are Identified, The Customer Has The Right To Demand A Replacement. Delivery And Acceptance Are Carried Out Only On Working Days And Working Hours. For Imported Goods, A Certificate Of Origin Is Provided. In The Event Of Delivery Of A Product That Does Not Meet The Declared Characteristics, The Supplier, At Its Own Expense, Ensures Reconfiguration Of The Washing Equipment And Repair Of The Equipment Or Processed Products., Biological Indicator Kit Bi (30 Pieces Per Box), Incubation Time 24 Hours, Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). A Self-Contained Biological Indicator Incubated With Geobacillus Stearothermophilus, A Highly Resistant Bacterial Spore, Designed To Safely And Effectively Monitor Sterilization Processes. Spore Density Is 1–1.2×10⁶ Cfu/Disc. The Color Of The Nutrient Medium Is Purple. Incubation Time Is 24 Hours At A Temperature Of 60±2 °C. Storage Conditions: Temperature 10–30 °C At Relative Humidity 30–80%. Quantity Per Package: 30 Pieces. Package Size: Width 8.2 Cm, Height 9.3 Cm, Depth 14 Cm. Bottle Dimensions: Diameter 1 Cm, Height 4.5 Cm. Designed Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek., Chemical Indicator - Strips, Pack Of 250, Manufactured By Meditek Human Co., Ltd. (Republic Of Korea). Chemical Indicator Strips Are Intended For Use In Human Meditek Plasma Sterilization Devices And Are Placed In The Packaging Together With The Products To Be Sterilized. During The Sterilization Process, Upon Contact With Hydrogen Peroxide Vapor, The Indicator Strips Change Color From Red To Yellow, Which Confirms The Completion Of The Sterilization Cycle. The Indicator Development Time Is 30–60 Minutes. Dimensions Of One Strip: Length 10.5 Mm, Width 18 Mm. Shelf Life - Up To 2 Years From The Date Of Production. Storage Conditions: Room Temperature 15–30 °C In A Dry Room At A Relative Humidity Of 20–80%, With The Obligatory Exclusion Of Exposure To High Temperature, High Humidity, Sterilants And Direct Sunlight. There Are 250 Pieces In A Package. Intended Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek., Biological Incubator, Incubation Time 24 Hours, Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). Designed For Incubation Of Biological Indicators After Sterilization And Maintaining A Constant Temperature To Ensure The Growth And Cultivation Of Microorganisms In The Biological Indicator. The Operating Temperature Range Is From 5 To 40 °C, The Maximum Relative Humidity Is Up To 80%. Incubation Temperature - 60±2 °C, Incubation Time - 24 Hours. Electrical Parameters: Voltage 200–240 V, Frequency 50/60 Hz, Current 0.375 A. Product Weight - No More Than 1 Kg. Overall Dimensions (L×W×H): No More Than 95×130×76 Mm. The Number Of Indicator Cells Is 15. The Product Is Manufactured In Accordance With Electrical Safety Standards Csa C22.2 No. 61010-1, Ul 61010-1 And Iec/En 61010-1. Intended Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek., Tablet Salt Is Intended For Use In Water Softening And Treatment Systems For The Purpose Of Regenerating Ion Exchange Resins. Used To Protect Pipelines, Heating Elements And Process Equipment From The Formation Of Lime Deposits. It Is Table Evaporated Salt (Nacl) Of The “Extra” Grade Pressed Into Tablets Without The Addition Of Iodine And Anti-Caking Additives. Mass Fraction Of Sodium Chloride - Not Less Than 99.5%. Salt Does Not Contain Insoluble, Mechanical And Microbiological Impurities. The Tablets Ensure Uniform Dissolution And Stable Concentration Of The Saline Solution, Do Not Cake And Do Not Form Solid Deposits In The Salt Solvent. Complies With The Requirements Of St Rk Gost R 51574. Appearance - White Tablets Without Foreign Odor. Shelf Life: At Least 24 Months. Packaging: Bags That Provide Protection From Moisture And Dirt. The Product Must Be New, Without Damage To The Packaging, And Is Subject To Mandatory Prior Approval With The Customer. Delivery And Acceptance Are Carried Out Only On Working Days And Working Hours. In Case Of Non-Compliance With The Declared Characteristics, The Supplier Is Obliged To Replace The Product At Its Own Expense., Roll Sterilization Bag Designed For Plasma Sterilizers Manufactured By Human Meditek Co., Ltd. (Republic Of Korea). Thermo-Sealable Packaging Rolls Are Used In Human Meditek Plasma Sterilizers And Are Intended For Packaging Medical Products With Subsequent Long-Term Storage After Sterilization. The Bags Are Made Of Polyethylene, Polyester And Special Material That Allows The Sterilizing Agent To Pass Through. Roll Size - 200Mm × 70 M, Material Thickness - 240 Microns. Material: Front Side - Transparent Ldpe, Back Side - White Tyvek®. Sealing Temperature: 115–130 °C. Storage Conditions: Temperature 25±5 °C, Relative Humidity 50±5%. Intended Exclusively For Use In Plasma Sterilizers Manufactured By Human Meditek.
|