Electronic Scalpel 300 Watts Microprocessed. For Use In All Types Of Surgeries, Low, Medium And High Complexity, Without Restriction, For Both Heart Surgery And Urological Surgery Or Neurosurgery. Cut And Coagula In Humid Field (Underwater) Enabling All Types Of Endoscopic Resection. Allow Simultaneous Work And Electronic Scalpel 300 Watts Microprocessor. For Use In All Types Of Surgeries, Both For Heart Surgery And Urological Surgery Or Neurosurgery. Cutting And Coagula In Humid Field (Underwater) Enabling All Types Of Endoscopic Resection. (...), Microprocessed Inhaling Anesthesia Car To Care For Neonatal, Pediatric, Adult And Morbid Patients. Structure In Non -Oxidizing Material; Or With Anti -Corrosion Treatment. With Shelf For Monitors Support; 03 Drawers, At Least One With Key, And Desk; With Rotating Casters, Being At Least 02 With Locks. With Functional Autoteste System For Error Detections, Operating Failures, Etc. With Universal Single Flow Sensor For Adult Patients To Neonates; With The Possibility Of Using Autoclavable Flow Sensor. Valves For Flow And Pressure Control With Safety System To Protect The Patient From Pressure And Inadequate Flows. Rotameter Consisting Of High -Scales With High And Low Flows At Least For Oxygen (O2) And Nitrous Oxide (N2o) And May Be A Single For Compressed Air Or Digital Monitoring With Oxygen Input (O2), Compressed Air And Nitrous Oxide (N2o). Safety System To Automatically Interrupt N2o Flow In The Absence Of O2; Quick Hitch Vaporizer, Allow 02 Vaporizers And Security System For The Selected Agent. Patient Circuit System Of Rapid Assembly And Disassembly By The Operator And Sterilization Subject To; Tracheas, Valves, Respiratory Circuits, Canister And Volume Delivery System, Self -Share; Canister For Soda Cal Storage; Possibility Of Gas Exhaust System; Graduated Apl Valve; Passive Bellows, Bypass, Fully Autoclavable Filter. Microprocessed Electronic Fan With Lcd Display With A Minimum Color-Colored Screen. Minimum Ventilatory Modes: Manual Ventilation; Ventilation With Spontaneous Breathing Without Fan Resistance; Volume Controlled Ventilation And Cycled On Time (Vcv);, 06.2.29237 - Vital Signal Signal Multiparrameters Monitor, At Least 12 ”Lcd Screen In Single And/Or Modular Block To Be Used In All Hospital Environments, With The Following Parameters: Ecg, Breathing, Oximetry, Pni And Temperature. From The St Segment Of All Derivations, Detection Of Arrhythmias And Loose Electrode, Option To Show The Trend In Minimized. At Least 8 Curves Of Vital Signal Monitor, Option To Show The Tendency In Minimized Presentation. And Iii), 0 To 150 Rpm Measurement Range, ± 2 Rpm Accuracy, Showing Numerical And Graphic. Oximetry: 0 To 100%Measurement Range Of 25 To 250 Bpm Pulse With Resolution Of 1 Bp, Showing In A Numerical And Graphic Way.
|