Tripod Support Extinguishing Up To 12 Kgtype: Type Soil Support With Capacity To Support Extinguishers Up To 12 Kg. Material: Carbon Steel, Painting: Bchromatized, Dimensions: 17 Cm Diameter; Approximate Height Of 30 Cm; Approximate Weight: 0, 6 Kg., Wall Support Extinguisher Up To 12 Kg- Wall Extinguisher Support, Capable Of Supporting Extinguishers Up To 12 Kg; Material: Carbon Steel; Painting: Zinca Or Bichromatized With A Support Hook Of Approximately 8 Cm And Two Holes For The Wall Fixation Approximately 6, 5 Cm. Extinguishing Agent: Abc / Monoamonic Phosphate. Weight: 6 Kg. Intended To Combat Class A (Solid Waste) Fire Principles, B (Flammable Liquids), C (Electrical Equipment), With Working Pressure Around 10 Kgf./Cm2. Color: Red. Manufacture: According To Abnt Nbr 15808. Approximate Dimensions: Diameter = 13, 8 Cm; Height = 56, 3 Cm; Total Weight: Approximately 9, 15 Kg. Extinguishing Capacity = 4A-40B-C. Hydrostatic Testing: 5 Years, Extinguisher Extinguisher Identification Card, Extinguisher Identification, 1 Mm Pvc Photoluminescent, 20 Cm X 20 Cm E5 E5 Dimensions. Red Color And Pictograms In Accordance With Abnt Nbr 13434-2, It 15 Cbmmg Standards, With Self -Adhesive Tape, Level Ii - Ap 10 Lcontamplation Will Complete The Full Disassembly Of All Components Of The Extinguisher For Cleaning. Then The Visual Inspection Of The Parts And The Interior Of The Extinguisher Should Be Performed. All Components Under Pressure Should Then Be Tested And Tested. Finally The Extinguisher Must Be Reassembled And Ring, Lock, Seal, Other Components And The Proper Seal Of Inmetro And Warranty Term Will Be Placed. It Should Also Be Performed, If Necessary, The Extinguisher Recharge, Breeding Seal (S), Violated External Identification Ring Change, Component Replacement, When Necessary, With Other Original, Regulating Relief Valves And Pressure Regulator, When There Is, Revision Of The Defects In The Systems Of High, Transportation Or Drive, According To Abnt Nbr 12962, 005/2011 And Updates. Periodicity: Maintenance Is Mandatory And Should Be Performed Every 12 Months (Annually) Or According To Corrective Maintenance Demand. Material: Pressurized Water Extinguisher With A Nominal Load Of 10 Liters, Intended To Combat Class A Fire Principles For Small Areas, Extinguishing Capacity 2 -A., 06/11/2025, Level Iii - Ap 10 Will Be The Same Same Sequence Of Level 2 Maintenance, But Includes Two Additional Steps. The First Of These Is The Hydrostatic Test, Which Serves To Identify Integrity And Resistance, Also Of The Cylinder. The Second Of These Is Cylinder Painting: Repinence According To Standard And Placement Of The Instruction Board, When Necessary. The Containers And Cylinders Of The Fire Extinguishers Should Be Painted Externally In Red Color, Preferably According To The Munsell 5 R 4/14 Standard. Periodicity: Maintenance Is Performed According To Abnt Nbr 13485 Standard, Inmetro Ordinance 005/2011 And Updates And Must Be Performed Every 5 Years Or In A Lower Time As Per Corrective Maintenance Demand. Material: Pressurized Water Extinguisher With Nominal Load Of 10 Liters, Extinguishing Capacity 2 -A, Maintenance Level Ii - Bc 06 Kgcontemplating The Complete Disassembly Of All Ext Components
|