|
Type A Stage - Stage With Minimum Dimensions Of 16M X 12M, In Metal Structure To Aluminum, With A Right -Back 2M -Wide Fly Tower, P50 Aluminum Air Contour, With Minimum Ground Floor Of 2,00M, Floor In Galvanized Tubular Structure, Covered With Naval Plywood With A Minimum 25Mm Thickness, With A Capacity Of 450 Or Higher. Kg/M² (Static), According To Abnt Standard, The Floor Will Not Contain Amendments, With Relief Or Depression, Its Surface Should Be Completely Uniform, 02 P30 Waterfall Cover, With Minimal Support Capacity For 3,000 Pvc Canvas, White, Blue Or Red, Standard, Night And Day, Anti-Mopus And Anti-Mammal. Galvanized Plate, With Tubular Hardware, And Runs, To Chest On The Sides And In The Bottom, Have Place For The Placement Of The Event Logo, With Assembly And Disassembly Included., Led Outdoor Panel High Definition Water Resistant Of At Least 6Mm, To Be Used By M2, Can Be In External Areas In The Transmission Of Live External Shows. (Csf System For German Stage) May Be Equal To Or Similar To Jbl 4888, Jbl4889, Norton Ls-9, Ls Audio, Fz-J15 ...) For Large Event, With A Structure Composed Of: Sound With 64 Sub-Graves 2,400W Rms Each; 48 Boxes With At Least 03 Acute Severe And Medium Ways (2,000W Rms Each); 04 Mixing Console With Minimum 48 Channels, (Minimum) 16 Subgroups, 24 Lr Master Auxiliary Roads, 08 Bands Plus 04 Parametric, With Insert Point On All Channels; 02 Frequency Dividers With Minimum 04 Copies With Minimum 24 Db Per Octave, Phase Angle Adjustment Between Bands, Entrances And Balanced Outputs; 02 Stereo Graphic Equalizers With Minimum 31 Bands And 06 12 Db Filters Per Octave; 12 Stage Floor Monitors, Battery Sub, 02 Side Lr Line Array, Downward And Keyboard Return Amplifiers, 48 Microphones With Respective Pedestals; 06 Wireless Voice Microphones, With Selectable Work Frequency And Uhf Operating Range; 24 Impedance Direct Box For Instruments; 02 Multicabos With Minimum 60 Copies Of 60 Meters; 01 Mixing Console With Minimum 52 Channels, 24 Copies Aux. Masterlr, Power Amplifiers Compatible With The Pa System. All Signal Distribution Should Be Done With Balanced And Electrically Isolated Cables From The Control Center Stage Equipment, A1 Light Table Light 2, 02 Martin Macvipeirfx, 20 Robin Pinte, 20 Bean Rush Mh3, 16 Robin Led Wash 600, 14 Stroboatomic 3000 Led, 14 Sgm Led P-5, 30 Rgbdw Led Par, 15 Led 4 Lamp Led, 12 Cob Cob, 02 Fogs 3000 With Fan., High Definition Indoor Panel Of At Least 4Mm, To Be Used Per Panel, Measuring 6X4, Can Be In Internal Areas. Measuring At 4M High., Houser Mix Mix In Aluminum Structure Q-30 Measuring 5X5 With Vinyl Canvas Ant-Flame., Galvanized Steel Structure Plates Measuring 2Mx2m With Assembly And Disassembly Included. Galvanized., Covered Stand For Camarin - Covered Stand, Mounted On Octanorm System, Having The Following Characteristics: Dimensions: Minimum Length: 4M X 4M, Floor: Assoalh
|