Table Pulse Oximeter (Adult, Pediatric And Neonatal Sensor) Features: Color Graphic Display With Touch Screen 3, 2; Sd Card Input Connector; Alarms: Distinct Sound Alarms To Check The Sensor, Upper Or Lower Boundary Alarms Exceeded For Peripheral O² Saturation, Very Long Demand Alarm, Pulseless Patient Alarm; Alarm Limits Oximetry: 30 To 100 In Steps Of 1; Pulse Alarm Limits: 15 To 250 Bpm In 5 Bpm Steps; Power Supply: Battery Version (Autonomy From Up To 12Hs To Full Charge) External Source (Optional); 64 Hours Of Information Storage; Dimensions: 86Mm X 138Mm X 30Mm; Weight: 0, 5Kg (Maximum Without External Power Supply); Measurement Range: Saturation 40 To 100 Pulse From 35 To 250Bpm; Alarms: 30 To 100 Pulse Saturation From 15 To 254Bpm., Hospital Nebulizer 8 Outputs With Specifications Support: Voltage: Automatic Bivolt; Product Dimensions (Cm): 104 X 45 X 45; Weight: 7, 6 Kg (Without Accessories); Flow Intensity: Intense; Anvisa No. 10332170049; Wireless Operation: No (Requires Power Via Power Grid); It Has Battery: No; Automatic Shutdown: No; Hose Length: 1, 5 Meters; Medicines Restriction: No; Warranty: 1 Year After Receiving The Product; Items Included: 01 Inhaler; 08 Adult Masks; 08 Childrens Masks; 08 Turbo Nebulizers; 08 Air Hoses; 01 Support With 5 Casters With Lock; Product Dimensions: 104 Cm X 45 Cm X 45 Cm (Cxlxa) Weight: 7.6 Kg Package Dimensions: 104 Cm X 45 Cm X 45 Cm (Cxlxa) Weight: 7.6 Kg, Multiparameter Monitor Indications: Adult, Pediatric And Neonatal Use. Hospitals, Icu, Surgical Center, Emergency Room. Specifications: Display: 12.1 Colorful (With Tft Touch Screen Option); Ecg: Dynamic Input Range: (0, 5Mvp 5Mvp); Input Impedance: = 10 Mo; Band Width: 0.05 150Hz (Diagnostic Mode) - 0.5 40Hz (Monitoring Mode); Cmrr: 1 20Hz (Operation Mode); = 90 Db (Diagnosis); = 105 Db (Monitoring And Operational); Sensitivity: X 1/4, X 1/2, X 1, X 2, X4 And Automatic; Scanning Velocity: 6, 25Mm/S, 12, 5Mm/S, 50Mm/S; Hr Measurement Range: 15 350Bpm; Hr Accuracy: 1 Or 1Bpm, Whatever It Is; Detection And Rejection Function Of Pacemaker Pulse; Protection Against Defibrillator Discharge; Arrhythmias Analysis; St/Qt/Qtc Monitoring; St Follow -Up: St Follow -Up Range: -2, 0Mv 2, 0M; Precision: 02Mv; St Follow -Up Analysis: In All Derivations; Resp: Thoracic Impedance Measurement; Measurement Range: 0 150Rpm; Resolution: 1 Rpm; Spo2: Technical Specification: Double Wavelength Optical Method; Measurement Range: 0 100; Precision: 2 For The 70 To 100 Spo2 Range; Pr Measurement Range: 0 300 Bpm; Pr Precision: 2Bpm Or 2 What Is Bigger; Low Perfusion Performance: = 0, 3; Technology: Moveoxy (Optional Nellcor, Masimo); Non -Invasive Pressure (Pni): (Remaining Exhibition Is In The Term Of Reference And Notice), Table Portable Hospital Sealer Characteristics: Ptc Resistance Shielded With Automatic Temperature Control. Automatic Bivolt (110-240V). Integrated Cutting System In Both Directions. Drive Through Lever With Lock. Microcontrolled System For Greater Accuracy In Sealing Time. Warning System With Indicative Leds And Sound Beeps On The Membrane Keyboard. Automatic Shutdown In Case Of Inactivity For 60 Minutes. Power: 80 W. Sealing Area (Length): 30 Cm. Sealing Thickness: 12 Mm. Compact
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 94518263
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.