Tenders Are Invited For Laboratory, Optical And Precision Equipments (Excl. Glasses) - Supply Of Equipment F ...
Tender Notice
TenderID
79561221
Tender Brief
Tenders Are Invited For Laboratory, Optical And Precision Equipments (Excl. Glasses) - Supply Of Equipment For National Temperature Standard And Standards For Spectral Transmittance And Angular And Linear Velocity
Laboratory, Optical And Precision Equipments (Excl. Glasses) - Supply Of Equipment For National Temperature Standard And Standards For Spectral Transmittance And Angular And Linear Velocity. 1. - 1 Pc. Ac Bridge For National Temperature Reference. Specialized Training. Accuracy - 0.1Ppm Or Better Over The Entire Range Measuring Range - 0 Ω To 200 Ω Or Wider Display Range For The Ratio Of Two Resistances - 1.0000000 Or Wider Measuring Current - 1.0Ma; 2.0Ma; 5.0Ma; X√2; X0.1; X10 10-Channel Switch With The Possibility Of Remote Control Via Software 2. Specialized Software For Control And Mathematical Processing Of The Results When Calibrating With The Primary Standard 1 Pc. Development Of Specialized Software That Must Be Able To Receive And Process Information From The Ac Bridge, As Well As The Possibility Of Remote Control Of All Its Functions. Ability To Calculate Measurement Uncertainty. 3. Cuvette Holder For Two-Beam Spectrophotometer - 1 Pc. For Standard 10 Mm Cuvettes; Temperature Range: From 10 °C To 70 °C Or More Extended; Accuracy: ± 0.3 °C Full Range Or Better; Resolution: ± 0.1 °C Or Better. 4. Temperature Controller - 1 Pc. Temperature Range: From 10 °C To 70 °C Or More Extended; Accuracy: ± 0.1 °C Or Better Control Software. 5. Signal Generator - Functional With Pre-Programmable Form - Sinusoidal, Rectangular And Triangular Signals. -1 Piece. Two-Channel Function Generator With Two Independent Output Channels: - Range: From 1 Μhz To 20 Mhz Or More Extended; - Resolution: 1 Μhz Across The Range Or Better; - Signal Forms: Sine Wave, Rectangular And Triangular Pulses With The Possibility Of Signal Modulation; - Output Amplitude: From 10 Mvpp To Max. 10 Vpp Or Better. - Adjustment Of The Filling Factor - From 1% To 99% For Rectangular Pulses; - Accuracy: ±2 % Of Setting ±1Mvpp (At 1 Khz) Or Better; - Display - Color Tft Lcd 3.0 Or Larger; - Interface For Managing And Modeling The Signal Shape; - Pc Connection And Signal Management Software. 6. Nanovoltmeter - 1 Pc. Constant Voltage - Compatible To Work With The System For Ac-Dc Transfer Measurements And The Control Software Developed In The Ei Department; - Compatible To Work With The Available Keithley 2182A Nanovoltmeter; - Range 10 Mv: - Resolution - 1 Nv; -Accuracy - 60 Ppm Per Year; -Dc Noise Level - 30 Nv Peak To Peak (1 S Response Time), 70 Nv Peak To Peak (60 Ms Response Time). -Range 100 Mv: -Resolution-10 Nv; -Accuracy - 40 Ppm Per Year; -Dc Noise Level - 175 Nv Peak To Peak (1 S Response Time), 300 Nv Peak To Peak (60 Ms Response Time). -Range 1 V: -Resolution - 100 Nv; -Accuracy - 30 Ppm Per Year; -Dc Noise Level - 600 Nv Peak To Peak (1 S Response Time), 700 Nv Peak To Peak (60 Ms Response Time).
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 79561221
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.