The Subject Of The Order Is The Hardening Of The Area And The Designation Of The Kiss And Ride Bay On The Premises Of The School And Kindergarten Complex No. 2 In Piekary Śląskie. The Subject Of The Order Is, Among Others: 1) Measurement Works For Linear Earthworks - Road Route In Plain Terrain - Set. 1;2) Industry Arrangements And Supervision – Set. 13) Inspection Ditch To A Depth Of Up To 2.0 M - Set. 44) Troughs Made Mechanically And Manually Over The Entire Width With A Depth Of 51 Cm (Including Manual Or Mechanical Dismantling Of The Surface Made Of Mineral And Bituminous Mixtures, Crushed Stone, Concrete Cubes Of All Types, Curbs, Edges, And Other Encountered Elements) With Transport, Segregation And Disposal - 721 M2 5) Troughs Made Mechanically And Manually Over The Entire Width, 41 Cm Deep (Including Manual Or Mechanical Removal Of Surfaces Made Of Mineral And Bituminous Mixtures, Crushed Stone, Concrete Cubes Of All Types, Curbs, Edges, And Other Elements Encountered) With Collection, Segregation And Disposal - 199.8 M2 6) Securing Underground Infrastructure - Set. 37) Base Layer Made Of Crushed Natural Aggregate With A Thickness After Compaction Of 40 Cm - 721 M2 8) Base Layer Made Of Crushed Natural Aggregate With A Thickness After Compaction Of 30 Cm - 199.8 M29) Surface Made Of Concrete Paving Stones, 8 Cm Thick, Graphite Color - On Ballast Cement-Sand 3 Cm With Filling The Joints With Sand - 372.5 M210)Surface Made Of Concrete Paving Stones, 8 Cm Thick, Red - On A Cement-Sand Ballast 3 Cm With Filling The Joints With Sand - 302.5 M211)Surface Made Of Concrete Paving Stones (Used ) 8 Cm Thick, Gray Color - On A Cement-Sand Ballast Of 3 Cm, With Joints Filled With Sand - 85 M212) Surface Made Of Concrete Paving Stones, 8 Cm Thick, Gray - On A 3 Cm Cement-Sand Ballast, With Joints Filled With Sand - 78.8 M213) Concrete Curb Footing With Resistance - 11.52 M314) Protruding Concrete Curbs, Dimensions: 15X30 Cm Placed On Fresh Concrete - 94 M15) Embedded Concrete Curbs, Dimensions. 15X22 Cm Placed On Fresh Concrete At The Entrances - 18 M16) Bench For B-10 Concrete Edging With Resistance - 10.58 M317) Concrete Edging Dimensions. 30X8 Cm Placed On Fresh Concrete - 176.4 M18) Purchase And Installation - Led Solar Lamps - 3 Pcs.19) Replacement Of Sodium Luminaires With Led Luminaires - Premises Of The Facility - 3 Pcs.20) Channels Made Of Pvc Pipes Pressed Together Ø160 To Ø200 Mm, Excavation Depth Up To 3.0 M, Including Backfill And Backfill, As Well As Excavation And Backfilling Of The Excavation - 46 M21) Sewage From Concrete Elements (Linear Drainage) With Dimensions Length/Width/Height. 1000/150÷300/150÷350, On Cement-Sand Bedding, Class D400 With Cast Iron Grate/Cover - 23 M22) Construction Of An Inspection Well, Diameters From Ø800 To 1200 Mm, Regulation, Excavation And Backfilling Of The Excavation - Pcs. 123) Construction Of A Sewage Well Street Along With The Installation Of A Relief Ring, Adjustment, Excavation And Backfilling Of The Excavation - Pcs. 124) Concrete Waste Bins - Purchase And Installation On The Premises - Pcs. 425) Dismantling Of The Existing Mesh Fence And Expanded Metal Mesh On Metal Posts Encased In Concrete, Including Dismantling Concrete Elements (Foundation) With Transport, Segregation And Disposal - 49 M26) Construction Of A Panel System Fence: Manual Digging Of Pits With A Bottom Area Of Up To 0.2 M2, Depth Of Up To 1.0 M, Soil Category Iv - For The Post, Concreting Of The Fence Posts ., Installation Of A Prefabricated Foundation, Installation Of Spans 2.50 M Long, 1.50 M High + Posts, Installation Of A Steel Panel Gate-Wicket 1.50 X 3.00 - Pc. 1.27) Thick-Layer Horizontal Marking In Orange - Painting Backgrounds On Kiss&Ride Bays + Painting The K+R Inscription In White - 40 M228)Kiss&Ride Vertical Marking - Pcs. 229)Purchase And Installation Of A Commemorative Plaque, Dimensions Min. 1M X 1M - 1 Pc.30) Temporary Traffic Organization Design For The Duration Of The Works (With Approval) Along With Implementation - Set. 131) Preparation Of Post-Construction Surveying Along With Marking The Resources - Set. 1Technical Parameters Of A Single Built-In Led Solar Lamp:•Power – Min. 50 W, • Luminous Flux – Min. 157 Lm/Watt, • Battery Capacity – Min. 2 X 120 Ah, • Photovoltaic Panel - Min. 290 W, • Pole Height - From 5 To 6 Meters, Galvanized Steel Pole, • Dusk, Motion Sensor - Yes, • Light Source Power Min. 3700 Lm, • Luminaire Optics Directing The Light Stream Forward, • Foundation Min. F-100,•An Autonomous Lantern Should Be Equipped With A Set Of Devices (Controllers) Controlling The Operation Of The Lantern (Automatic Switching On/Off At Dusk),•Application - Streets, Sidewalks, Squares.Technical Parameters Of A Single Led Luminaire (Replacement Of A Sodium Luminaire With An Led One):• Led Power: Min. 72W•Total Power: Min. 79W•Led Luminous Flux 1: 11650 Lm•Luminous Flux 1: 9950 Lm•Color Temperature: 4000K•Supply Voltage: 220-240V•Rated Current: 1000 Ma•Light Angle: 120°•Material: Aluminum Alloy, Anodized•Length: Min. 700 Mm•Width: Min. 160 Mm•Height: Min. 80 Mm•Optics - Wide-Angle Light Distribution•Application: Illumination Of Streets, Roads, Parking Lots, Squares, Recreational Areas And Other Outdoor Facilities.The Remuneration For The Execution Of The Subject Of The Agreement Is A Lump Sum.Increase Or Decrease In The Number Of Bills Of Quantities, As Well As The Implementation Of Works Not Indicated In The Bill Of Quantities. Works Described Or Arising From The Agreement And The Implementation Of Other Works Necessary For The Proper Performance And Completion Of The Subject Of The Agreement Will Not Constitute The Basis For Changing The Contractors Lump Sum Remuneration. A Detailed Description Of The Subject Of The Order Can Be Found In The Annexes To The Swz.
|