Engineering Services – Asbestos Investigation (Sampling, Clearance Measurements And Analysis). The Advertised Services Are Carried Out In Various Buildings Throughout The Ukm (Including Central Clinic, Care Center, Dental Clinic, Etc.). The Period And Scope Of The Services Required Depends On The Needs And Size Of The Respective Projects. The Services Are Therefore Predominantly Carried Out At Very Short Notice, Irregularly And To A Very Varying Extent. Clearance Measurements (Asbestos Indoor Air Measurements) Must Be Carried Out In Renovation Areas Of Different Sizes (Up To 10 Devices/Clearance Measurement) At Short Notice And Evaluated Within 12 Hours After Dismantling. Sampling (Material, Dust) Must Be Carried Out Shortly After Being Requested And The Results (Protocols, Analysis Results, Plans) Of The Analysis Must Be Evaluated Within 5 Days Of Taking Over The Samples. Analysis Of Asbestos, Kmf, Pah, Kw, Pcb And Hsm. Analysis Of Asbestos According To Vdi 3866 Sheet 5 Appendix B:2017-06, Examination Using A Scanning Electron Microscope And Energy-Dispersive X-Ray Microanalysis, Sample Preparation By Ashing And Acid Treatment, Evaluation According To Vdi 3866 Sheet 5 Appendix B:2017-06 (Qualitative), Detection Limit 0.001 % Mass Fraction Asbestos. Accreditation According To Din En Iso/Iec 17025. Certification According To Ohsas 18001 (Occupational Safety, For Sampling). Main Dimensions: Measurements: 150 Pieces. Indoor Air Measurements Asbestos (Clearance Measurements, 1St Measuring Point) 50 Pieces. Indoor Air Measurements Asbestos (Clearance Measurements, Additional Measuring Point) 10 Pieces. Indoor Air Measurements Asbestos (Workplace Measurements According To Trgs 402) 5 Pieces. Indoor Air Measurements Pcb (1St Measuring Point) 5 Pieces. Indoor Air Measurements Pcb (Additional Measuring Point) Analytics: 50 Pieces. Asbestos In Fiber Product Samples (Nwg 1%) 75 Pieces. Asbestos In Fiber Product Samples (Nwg 0.1 - 1%) 75 Pieces. Asbestos In Fiber Product Samples (Nwg 0.001%) 25 Pieces. Asbestos In Tar And Bitumen Masses 50 Pieces. Asbestos In Contact Samples 5 Pieces. Ai Index, 10 Pieces. Pah According To Epa, 10 Pieces. Pcb, 6Th Cong., 2 Pcs. Hsm, 5 Pcs. Kw, 5 Pcs. Hbcd Hours: 100 H Appraiser 50 H Technician 20 H Technical Draftsman 50 Pcs. Travel Allowance
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 77679738
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.