Laboratory, Optical And Precision Equipments (Excl. Glasses) – Purchase Of A Bet Device In The Digitall Project. 1 New Bet Device (Gas Adsorption Analyzer) Minimum Technical Parameters Of The Device: - The Device Must Be Suitable As A Stand-Alone Device Or In Combination With A Static Physisorption Measurement Option Using The Dynamic Flow Method Titration Pulsed Chemisorption, Temperature Programmed Desorption (Tpd), Temperature Programmed Reduction (Tpr) ), Temperature Programmed Oxidation (Tpo), Temperature Programmed Reaction (Tpsr) To Perform Measurements. - The Device Must Include A Programmable High-Temperature Oven That Can Be Heated To At Least 900°C. The Device Must Be Able To Cool Down The Oven From 400°C To At Least 50°C Under Software Control, And This Should Take No More Than 60 Minutes. - The Device Must Be Able To Perform Measurements Using At Least Helium, Argon, Nitrogen, Oxygen, Hydrogen, Carbon Monoxide, Carbon Dioxide, And Ammonia Gases. Bottles Of The Listed Gases Must Be Able To Be Connected To The Instrument Via Separate Ports. The Parts Of The Instrument In Contact With These Gases Must Be Inert. - The Instrument Should Include A Steam Injection Unit For The Introduction Of Water Vapor And Methanol. - The Device Must Have A Sample Preparation Function. - The Instrument Is Capable Of Static Vacuum Volumetric Physisorption And Chemisorption Measurements, For Which At Least One 1000 Torr Transducer Is Installed. - The Device Should Be Designed In Such A Way That It Can Receive Both The Thermal Conductivity Detector (Tcd) And The Mass Spectrometry Detector. - The Device Must Be Equipped With A Thermal Conductivity Detector (Tcd) And A Mass Spectrometry Detector. The Mass Spectrometry Detector Should Enable Particle Detection Up To At Least 200 Atomic Mass Units, And The Control And Evaluation Software Should Contain The Molecular Library Necessary For The Evaluation. - The Device Must Be Delivered With A Complete Control Computer With Sufficient Capacity To Perform Control And Measurement Tasks With At Least The Following Configuration: O Processor: Intel Core I5-12600K Or An Equivalent Processor Or Higher Performance. The Contracting Authority Checks The Equivalence On The Website Www.Cpubenchmark.Net And Accepts The Cpu With A Score Of At Least 27,795 As Equivalent, With The Fact That In The Case Of An Intel Processor, The I3 Product Family Is Not Considered Equivalent To The I5 Product Family, Even With A Suitable Score. O Memory: At Least 1X16 Gb Ddr4 O Ssd: At Least 1 Tb Pcie Nvme M.2 O Video Card: Uhd Graphics 750 Or Equivalent Or Higher Performance. The Bidder Checks The Equivalence On The Website Https://Www.Videocardbenchmark.Net/ And Accepts The Video Card With At Least 1744 Points As Equivalent. O Display: At Least 23” Hd Resolution Led O Wireless Hungarian Keyboard, Mouse O Operating System: At Least Windows 10 Home Or Equivalent • The Operating System And The Sorptometer Control Software Must Be Pre-Installed On The Computer. • Features Of The Control Software: O Fully Functional, In English Or Hungarian,
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 77027506
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.