Tenders Are Invited For Supplying O.R Anesthesiation Equipment. -The [ Ministry Of Health / The State Company For Marketing Drugs & Medical Appliances (Kimadia) ] Now Invites Sealed Bids From Eligible Bidders For Supply Of: [(Anesthesia Work Station Qty (207))( Video Laryngoscope ,Adult Reusable))Qty(96)), (Video Laryngoscope, Pediatric Reusable) (Qty(82) ,( Electronic Nerve Stimulator (Anesthesia)) Qty ( 239 ) ,( Nerve Detecting Sonograph ) Qty (92 ) ) Anesthesia Work Station Video Laryngoscope ,Adult Reusable Video Laryngoscope, Pediatric Reusable Electronic Nerve Stimulator For Anesthesia Nerve Detecting Sonograph. Bidding Documents For Medical & Service Equipment Purchasing Fees: ($ 500/ Five Hundred Usd ). Bid Bond Value Is ($214,405.16)/ Two Hundred And Fourteen Thousand Four Hundred And Five Dollars And Sixteen Cent Only.) Date: Issued On [10\5\2023] Deadline: 30-05-2023. 1-Device Name: Anesthesia Workstation Application: Dispense A Mixture Of Gases And Vapors And Vary The Proportions To Control A Patients Level Of Consciousness And/Or Analgesia During Surgical Procedures. Patient Type: Adult, Pediatric, Neonatal. The Workstation Should Consist Of: Part I:Anesthesia Unit (Trolly Version) Gas Supply & Control: Pipeline Gas Inlets: At Least 3 (N2o, O2, Air). Gas Cylinder Yokes: (O2, N2o, Air) (Should Include Indexing System). Fresh Gas Mixer: Electronic Mixer Or Mechanical With Digital Read Out. Vaporizers: Agents: Desflurane, Isoflurane, Sevoflurane. Type Of Vaporizers: According To Manufacture, Heated Blender (If Desflurane Selected). No. Of Vaporizers: 3 Vaporizer Station: 2 Vaporizers Mounted In Same Time With Interlock Hypoxic Mixture Fail-Safe: Yes. O2 Fail Safe: Yes. Automatic Gas Control Or Specialized Low Flow Software Ventilator: Type: Automatic. Ventilation Modes Control: Manual Spontaneous, Vcv, Pcv, Simv , ,V C Synchronized , Synchronized Pc , Cpap , Peep. Pressure Support & Pressure Control Volume Guaranteed. Tidal Volume (Cc): (5~1400). Minute Volume (LMin): (0~99). Frequency Bpm: (0~100). Inspiratory Flow (LMin): (200). Pressure Limit (Cm H2o): (120 Adjustable). Peep (Cm H2o): (0~50). Lung Recruitment System Checks: Self-Test (Automated). Scavenging System: Active Or Passive. Breathing Circuit: Type: Circle System. A Fresh Gas Flow Port. A Reservoir Bag. An Expiratory Port With Apl Valve To The Scavenging System Is Driven Through A Co2 Absorption Canister (Soda Lime Or Barium Hydroxide Lime). Corrugated Tubes. Pressure Gauge. Monitors: Airway Pressure, Expiratory Volume/Flow, O2 Concentration, Peak Inspiratory Pressure, Mean Airway Pressure, Peep Pressure, Tidal Volume, Minute Volume, Spontaneous Minute Volume, Fio2 (Analyzed %), Respiratory Rate, Inspiratory Time, Expiratory Time & Ie Ratio. Display: Touch Screen No: 1 Plus Operating Room Monitor. Type: Color Lcd Or Better. Size: 15. Spirometry Loops : (P/V) , Flow/V Integrated: Yes. Interface Date With Patient Monitor: Yes Tender Link : Http://Kimadia.Iq/En/Article/View/38
|