Tenders Are Invited For Three (3) Years Term Contract For Fire Protection Services And Related Works Of Politeknik Brunei, Lumut Campus. Fee: $5.00 Quantity In The B.Q Are Provisional Only And Subjected To Final Measurement On Site On Completion Of Works Supply All Labour, Equipment, Materials And Tools Including Transportation To Do The Following Supply/ Installation/ Maintenance / Repairworks To Its Good Operational Conditions And To Current Good Practice And Make Good To All Works Distributed To Match The Existing Or To S.O S Satisfaction. Work Covered Comprises Operation And Maintenance, Troubleshooting And Repair, Replacement Or Supply, Delivery, Installation, Testing And Commissioning C/W Necessary Accessories And Works Require For A Proper Installation And Equipment To Function In Order And Accordingly, Acceptable By S.O In Charge As Follows :- Section 1 : Fire Protection Services. Section 2 : Mechanical - Related Mechanical Works Section 3 : Plumbing - Related Plumbing Works All The Works Carried Out, Materials, Equipment Supplies Etc, For The Above Installation Shall Be Strictly In Accordance With The Local Authority Standards And Original Equipment Specification. Standards To Comply :- 1. Fire Safety Order, 2016, Brunei Fire Rescue Department. 2. Fir Guideline Or Current Nfpa. 4. Bs 5306 Standards. 5. Pbd12: 2017. 6. Eir Des Electrical Standards Or Latest Iee Wiring Regulations. Important Note : * Contractor Should First Provide Pre-Inspection Checking /Survey & To Produce Report Before Starting The Works. * The Contractor Undertakes To Carry Out The Services With Reasonable Care And Skill Using Appropriately Qualified And Supervised Person. * Contractor To Liaise With Brunei Fire Rescue Department [Bfrd] To Obtain Advice And Approval Of Works To Be Carried Out. Necessary Submissions Such As Permits, Drawings And Layouts To Be Available By Contractor For Approval. To Comply With Necessary Drawing Revisions As Per Ordered By Bfrd. Dpem And Bfrd Approval Is Required Before Work Commences. * All Materials/Fittings Offered As Per Des/ Dme/ Abci/ Bomba Approved Type Only. 2 *All Work Done And Completed Shall Be Duly Verified And Certified By Brunei Fire And Rescue Department [Bfrd] & Department Of Planning And Estate Management [Dpem] On Site Complete With Service Reports, Drawings Where Necessary And All Relevant Supporting Documents. *Maintain Binded Service Records Of Work Done And Updated Technical Data And Details. *Ensure That The Maintenance Personnel Are Available On A 24-Hour Basis To Provide Emergency Assistance. Contractor Shall Within 30 Mins Of Receipt Notice From S.O To Provide Assistance And Dispatch Of Qualified Engineer Or Technician On Site. * Rate Shall Include Prices For Transportation, Troubleshooting, Inspection, Labour, All Required Materials, Accessories And Tools (Test Equipment, Cleaning Materials And Lubricants Used) For Servicing And Replacement Of Equipment As Per Appropriate Standard To The Specification Of The Equipment And To Bfrd Standard, Rules And Regulations. *During The Continuance Of This Contract, The Contractor Shall Maintain Stocks Availability Of Equipment And Spare Parts To The Same Specifications Or At Very Least Be Functionally Equivalent To Existing Removed Parts. All Removed Parts/ Equipments Must Be Returned To The Respective Government Building With Relevant Service Report Verified And Endorsed. *Dismantle And Removal From Site Unused/Damaged Existing Equipment And Accessories As Per Instructed By S.O. Contractor To Clean And Clear Debris Off Site As Per Instructed By S.O And To Patch Up And Make Good Any Work Disturbed After Work Completed. *If The Units Under Repair Are Consider Beyond Economical Repair, The Superintendent Engineer Must Be Notify Immediately So That Inspection Can Be Carried Out To Verify The Report. If In The Opinion Of The Superintendent Engineer That The Units Still Can Be Repair, The Contractor Have To Repair It Accordingly To Working Order. Those Units Which Had Been Consider Beyond Economical Repair Will Be Omitted Temporarily From The Maintenance Lists Until New Replacement Is Available. Section 1 : Fire Protection Services A Routine Maintenance Inspections Of Fire Protection Services To Perform Checking Inspections Include General Cleaning And Service, Calibrating, Troubleshooting, Adjusting, Realigning, Testing And Reporting As Ordered By S.O Of :- [Contractor To Submit Proposed Work Program And Schedule Of Work. Report Must Be Verified By S.O] 1 Fire Alarm Systems And Other Related Accessories. Routine Service Shall Be Carried Out In Accordance To Schedule A.1. Inspection Per Campus / Premise. Lot 450.00 2 Smoke Ventilation System And Smoke Curtain System And Other Related Accessories. Routine Service Shall Be Carried Out In Accordance To Schedule A.2. Inspection Per Campus / Premise. Lot 250.00 3 3 Extingusher And Other Related Accessories. Routine Service Shall Be Carried Out In Accordance To Schedule A.3 Inspection Per Campus / Premise. Lot 250.00 4 Fire Hose Reels System And Other Related Accessories. Routine Service Shall Be Carried Out In Accordance To Schedule A.4 Inspection Per Campus / Premise. Lot 150.00 B Replacement, Installation And Repair Of Fire Protection Services [ Approved Type Only ] I . Fire Alarm Panel And Accessories Ii. Detectors And Accessories Iii. Wet Riser And Hose Reel System Iv. Fire Pumps And Control V. Fire Extingusher Vi. Sundries Item Vii. Smoke Curtains Viii. Firemen Intercom Ix. Smoke Ventilation X. Electrical Items Xi. Other Item Not Included Replace Or Supply, Installation, Testing And Commisioning C/W Necessary Accessories And Works Required. Equipment Supplied And Installations Shall Be Approved By Bfrd Only. Supplier Of Equipment Shall Be From Approved Bfrd Suppliers / Contractors Only. All Wirings Works Shall Be Done By An Approved Electrical Contractors. Finishes Shall Be Red In Colour Unless Otherwise Stated. Maintenance And New Installation Work Shall Have Inspection Sticker For Extingusher And Fire Alarm Panel. I Fire Alarm Panel And Accessories Conventional Fire Alarm Control Panel C/W Battery And Charger 1 2 Zone No 800.00 2 4 Zone No 1,000.00 3 8 Zone No 1,500.00 4 16 Zone No 2,000.00 5 32 Zone No 3,900.00 Addressable Fire Alarm Control Panel C/W Battery And Charger 6 2 Zone No 900.00 7 4 Zone No 2,800.00 8 8 Zone No 3,000.00 9 16 Zone No 3,200.00 10 20 Zone No 3,500.00 Conventional Gas Alarm Control Panel C/W Battery And Charger 11 2 Zone No 250.00 12 4 Zone No 450.00 13 8 Zone No 550.00 14 16 Zone No 650.00 15 20 Zone No 750.00 16 32 Zone Repeater Panel No 3,800.00 17 Mother Pcb Board Conventional Type No 250.00 18 Mother Pcb Board Addressable Type No 480.00 19 Zone Module Card Conventional Type No 180.00 20 Zone Module Card Addressable Type No 250.00 21 Battery Charger Unit No 105.00 22 3A-5A 24V Automatic Battery Charger Unit No 400.00 23 5A-10A 24V Automatic Battery Charger Unit No 650.00 24 12V Sealed Lead Acid Battery (Up To 20Ah) No 156.00 25 12V Sealed Lead Acid Battery (Above 20Ah To 50Ah) No 169.00 26 24Vdc Indicating Lamp No 5.00 27 Indicating Lamp Holder No 3.00 28 2 Loop Addressable Fire Alarm Panel No 6,200.00 29 4 Loop Addressable Fire Alarm Panel No 7,110.00 30 Loop Card No 650.00 31 Ram Card No 180.00 32 I/O Card No 105.00 33 Printer No 455.00 34 Printer Paper Roll 45.00 35 Digital Communication/ Auto Dailer No 585.00 36 Line Isolator No 250.00 37 Panel Key No 8.00 38 End Line Resistor No 8.00 39 Fault Buzzer No 40.00 Ii Detectors And Accessories 1 Alarm Bell No 80.00 2 Weatherproof Back Box For Alarm Bell No 50.00 3 Strobe Light No 2,800.00 4 Manual Call Point (Handle) No 45.00 5 Manual Call Point, Weatherproof (Handle) No 300.00 6 Sounder Beacon No 80.00 7 Unbreakable Manual Breakglass Unit No 60.00 8 Conventional Smoke Detector No 60.00 9 Conventional Heat Detector No 52.00 10 Conventional Gas Detector No 100.00 11 Addressable Beam Smoke Detector No 150.00 12 Addressable Smoke Detector No 150.00 13 Addressable Heat Detector No 150.00 14 Digital Commmunicator No 600.00 15 Spare Glass For Breakglass Unit No 5.00 16 Detector Base No 45.50 17 Remote Indicator No 50.00 18 Metal Hammer C/W Chain For Breakglass No 50.00 19 Fire Resistance Cable 1.5Mm Dia No 45.00 20 Fire Resistance Cable 2.5Mm Dia No 55.00 Mimic Diagram 21 A3 Size Including Frame No 100.00 22 A4 Size Including Frame No 50.00 23 Lpg Solenoid Valve No 300.00 24 Interlocking Control Panel No 300.00 25 Interface Card Gas Detector No 100.00 26 Gas Sensor No 80.00 27 Relay No 50.00 28 Contactor No 100.00 Iii Wet Riser & Hose Reel System 1 2 Way Fire Brigade Breeching Inlet No 250.00 2 4 Way Fire Brigade Breeching Inlet No 450.00 3 Air Release Valve No 80.00 4 2 Way Piller Hydrant No 300.00 5 3 Way Pillar Hydrant No 450.00 6 Hydrant Sluice Valve No 250.00 7 65Mm Dia 30M Long Layflat Fire Hose C/W Male/Female Instantanous Coupling No 450.00 8 Fire Hydrant Key And Bar No 100.00 9 Hand Wheel For Hydrant No 28.00 10 65 Dia Diffuser Nozzle With Male Instantanous No 210.00 11 19Mm Dia Fix/Swing Type Hose Reel Drum Complete With 30M Rubber Hose, Nozzle And Clip No 200.00 12 25Mm Dia Fix/Swing Type Hose Reel Drum Complete With 30M Rubber Hose, Nozzle And Clip No 200.00 13 19Mm Dia Fix/Swing Type Hose Reel Drum (Excluding Rubber Hose, Nozzle And Clip) No 150.00 14 25Mm Dia Swing Type Hose Reel Drum (Excluding Rubber Hose, Nozzle And Clip) No 150.00 15 19Mm Dia 30M Long Rubber Hose For Hose Reel Drum No 90.00 16 20Mm Dia 30M Long Rubber Hose For Hose Reel Drum No 90.00 17 19Mm Dia Hose Reel Nozzle No 20.00 18 25Mm Dia Hose Reel Nozzle No 20.00 19 Stop Nozzle With Nozzle Locking Device No 25.00 20 25Mm Dia Bronze Gate Valve No 20.00 21 50Mm Dia Bronze Gate Valve No 25.00 22 75Mm Dia Bronze Gate Valve No 40 Tender Link : Https://Pb.Edu.Bn/Politeknik-Brunei/Tender-And-Quotation/
|