Quotation Are Invited For Servicing Of 8 Uninteruptible Power Supplies At Various Ugu District Municipal Sites. The Ugu District Municipality Has A Number Of Uninterruptable Power Supply Devices At Several Of Its Sites Which Require Regular Routine Services. Equipment Are Listed On Page No.3 Under Specification The Ugu District Municipality Has A Number Of Uninterruptable Power Supply Devices At Several Of Its Sites Which Require Regular Routine Services. Equipment Are Listed Below Under Specification. This Contract Serves To Secure A 12 Month Service Level Agreement For The Maintenance And Services Of The Equipment Listed Below Under Specification I.E. 2 Services A Year, 6 Months Interval; Full Service Of The 8 Supplied Ups Devices, Not Limited But Including The Following; Checking The Mechanical Soundness Of Equipment Parts Checking Of The Semi-Conductor Power Devices, Transformers, Filter Elements And The Like On The Equipment Checking And If Necessary, Calibration Of The Equipment Dc Circuitry Checking And If Necessary, Calibration Of The Equipment Ac Circuitry Checking And Adjusting All Electronic Checking And Adjusting All Electronic Regulating Circuits Checking Of Batteries Forming Part Of The Equipment On The Following Specifics; O Checking And Recording On A Log Sheet Of The Voltage Of Each Block O Cleaning Of The Battery O Conducting A Battery Discharge Test Using The MunicipalityS Existing Load Connected To The Equipment To Determine The Capacity Of The Battery Detailed Service Report Fitment Of New Batteries, Remove Old Batteries, Fit New Batteries. (Batteries Will Be Supplied By Ugu Dm) Sum For Labour/Travel For Any Repairs Required During The Annual Ups Services Contingency Sum For Any Parts Required On An Ad Hoc Basis During Repairs 2 5 5 1 Annual Services Units Hours 10,000.0 0 4 All Bidders Wanting To Quote Need To Ensure The Specifications Above Are Adhered To. All Quotations Should Include A Comprehensive Proposal And A Subsequent Sla Will Be Signed. All Certifications To Support And Supply This License Must Be Attached To The Proposal By Prospective Bidders. For More Information Contact Leon Esterhuizen Site And Item Description: 28 Connor Street Port Shepstone Central Server Room 30Kva Ups 1 X Eaton 93E, 30 Kva / 27 Kw Transformer Less, Double Conversion, True On-Line Ups (93E30kmbsb) 400Vac/ 3-Ph, 50 Hz Input & Output Ups Parallel Ready Ups 2 X 32 X Csb Hrl1234w (12V/9Ah) 3-5-Year Design Internal Batteries Which Will Provide 8-10 Minutes Autonomy At Full Load Umtamvuna Water Purification Plant 6 Kva Ups 1 X Eaton 9Px, 6 Kva / 5,4 Kw Transformer Less, Double Conversion, True On-Line Ups (9Px6ki) 230Vac/ 1-Ph, 50 Hz Input & Output Ups Parallel Ready Ups 96 Marine Drive, Oslo Beach Phase 2 Server Room 15Kva Ups 1 X Eaton 93E, 15 Kva / 13,5 Kw Transformer Less, Double Conversion, True On-Line Ups (93E15kmbsb) 400Vac/ 3-Ph, 50 Hz Input & Output Ups Parallel Ready Ups 2 X 32 X Csb Hrl1234w (12V/9Ah) 3-5-Year Design Internal Batteries Which Will Provide 10 Minutes Autonomy At Full Load 6 Lind Road, Marburg Server Room (Building 3) 6Kva Ups 1 X Eaton 9Px, 6 Kva / 5,4 Kw Transformer Less, Double Conversion, True On-Line Ups (9Px6ki) 230Vac/ 1-Ph, 50 Hz Input & Output Ups 5 Site And Item Description: Parallel Ready Ups 1 X 9Pxebm180 Extended Battery Module, Which In Conjunction With UpsS Internal Csb Hrl1234w (12V/9Ah) 3-5-Year Design Batteries Will Provide 20 Minutes Autonomy At Full Load 31 Musgrave Rd, Harding, In Enquiries Office 6Kva Ups 1 X Eaton 9Px, 6 Kva / 5,4 Kw Transformer Less, Double Conversion, True On-Line Ups (9Px6ki) 230Vac/ 1-Ph, 50 Hz Input & Output Ups Parallel Ready Ups 1 X 9Pxebm180 Extended Battery Module, Which In Conjunction With UpsS Internal Csb Hrl1234w (12V/9Ah) 3-5-Year Design Batteries Will Provide 20 Minutes Autonomy At Full Load Cnr Main And Preston Roads, Park Rynie, Server Room 6Kva Ups 1 X Eaton 9Px, 6 Kva / 5,4 Kw Transformer Less, Double Conversion, True On-Line Ups (9Px6ki) 230Vac/ 1-Ph, 50 Hz Input & Output Ups Parallel Ready Ups 1 X 9Pxebm180 Extended Battery Module, Which In Conjunction With UpsS Internal Csb Hrl1234w (12V/9Ah) 3-5-Year Design Batteries Will Provide 20 Minutes Autonomy At Full Load Marburg R61, Off Oribi Toll Road, Ugu Disaster Centre 15Kva Ups 1 X Eaton 93E, 15 Kva / 13,5 Kw Transformer Less, Double Conversion, True On-Line Ups (93E15kmbsb) 400Vac/ 3-Ph, 50 Hz Input & Output Ups Parallel Ready Ups 2 X 32 X Csb Hrl1234w (12V/9Ah) 3-5-Year Design Internal Batteries Which Will Provide 10 Minutes Autonomy At Full Load Bobhoyi Water Purification Plant 1X Pss Epower Series On-Line Ups Ep10k Power 10Kva/9K Output 380/400/415Vac3ph+N+Pe 50/60Hz Bypass 380/400/415Vac3ph+N+Pe 50/60Hz Mains 380/400/415Vac3ph+Pe 50/60Hz Battery 384 Dc Tender Link :
|