Revamped Reforms-Based And Results-Linked, Distribution Sector Scheme Infrastructure Work Under Loss Reduction In Kesco, Kanpur- 1 Supply Of1.1_Kv Xlpe Insulated Pvc Sheathed Armoured Aluminum Cable In High Loss Area 2 2Cx6 Sqmm 3 2Cx10 Sqmm 4 4Cx16 Sqmm 5 4Cx25 Sqmm 6 Supply Of 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 7 Supply Of 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 8 Supply Of New Galvanised Stay Set With Anchor Plate ( 200X200x6mm ) , 50X8mm Stay Clamp, Stay Guy Insulator, Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 16 Mm Diameter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Etc As Required As Per Technical Specification, Approved Drawings And Scope Of Work. 9 Supply Of Spike Earthing 2540Mm Longmade Of 20Mm Gi Solid Rod. 10 Supply Of Hot Dip Galvanized G.I. Wire Earthing Coil 11 Supply Of 6 Swg Gi Wire 12 Supply Of 8 Swg Gi Wire 13 Supply Of Aerial Bunched Xlpecable 3X95+1X70+1X16 Sqmm 14 Supply Of Aerial Bunched Xlpecable 3X120+1X70+1X16 Sqmm 15 Supply Of Aerial Bunched Xlpecable 3X150+1X120+1X16 Sqmm 16 Supply Of Lt Pole Clamps With Nut & Bolts For Laying Abc 17 Supply Of Dead End Clamps With Eye-Hook ( Insulated ) 18 Supply Of Suspension Clamps With Eye-Hook ( Insulated ) 19 Supply Of Lt Insulation Piercing Connectors Of 25-150 Sqmm Size For Energizing Distribution Kiosk / Box 20 Supply Of Lt Insulation Piercing Connectors Of 25-120Sqmm Size For Energizing Distribution Kiosk / Box 21 Supply Of Lt Insulation Piercing Connectors Of 25-95Sqmm Size For Energizing Distribution Kiosk / Box 22 Supply Of L.T. Neutral Bare Connector. 23 Supply Of 1X25 Mm^2 Xlpe / Pvcinsulated Al. Cable For Energising The Distribution Boxes / Kiosk 24 Supply Of Single Phase Distribution Box With Clamps With Lug. 25 Supply Of Three Phase Distribution Box With Clamps With Lug. 26 Supply Of Pre-Fabricated Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Transformer Mounting Structure Etc Made Of Ms Channels ( 100X50x6mm ) , Ms Angle ( 65X65x6mm ) , Ms Flats ( 65X8mm ) Of Given Size Duly Galvanisedfor Over Head Structures As Per Technical Specification, Approved Drawings And Scope Of Work. 27 Supply Ofms Nuts, Bolts With Washers Duly Galvanised As Per Technical Specification, Approved Drawings And Scope Of Work ( Off Size ) . 28 Supply Of 11 Kv Polymer / Porcelain Disc Insulator 70 Kn Along With Suitable Hardware Fittings 29 Supply Of 11 Kv Polymer / Porcelain Pin Insulators 10 Kn With Gi Pin 30 Supply Of 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog 31 Supply Of Ci Packing ( Galvanised ) As Per Site Requirement. 32 Supply Ofdanger Plate 33 Supply Ofg.I. Barbed Wire 34 Supply Of 12 Kv, 1600 A, 350Mva, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breaker Along With 12 Kv, 1-Phase, 400-200 / 5-5 3 Nos Indoor Type Current Transformer, Indoor Mounting Type Control Panel For Feeder Protection, Control Cabling Between Vcb And Indoor Control Panel ( Scada Compatible & 61850 Protocol Compliant Protection Relays ) And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, 3-Phase Electronic Energy Meter, Relay & Accessories Complete For Feeder Breaker Protection Along With Adapter Panel / Complete Mechanism To Connect With Existing Busbaras Per Technical Specifications, Approved Drawings And Scope Of Works ( Outgoing Panel ) 35 Supply Of G.I. Pipe 6" Dia. With Clamps Etc. 36 Supply Of11kv Xlpe 3 Phase Power Cable Armored, Aluminium Conductor, Standard As Per Technical Specification, Approved Drawing And Scope Of Works 3Cx185 Sqmm 37 Supply Of Heat Shrinkable Jointing Kit Outdoor / Indoor For 11 Kv 3X185 Sq. Mm Xlpe Cable 38 Supply Of Heat Shrinkable Jointing Kit Outdoor For 11 Kv 3X185 Sq. Mm Xlpe Cable 39 Supply Of Heat Shrinkable Jointing Kit Indoor For 11 Kv 3X185 Sq. Mm Xlpe Cable 40 Supply Of 11Kv Straight Through Joint 3X185 Sqmm Xlpe Cable 41 Supply Of L.T Aluminum Armored Xlpe Single Core Cable Size 42 1X630 Sq Mm. 43 1X400 Sq Mm. 44 Supply Of Al Crimping Lugs ( 630 / 400 / ) Sq Mm. For All Cables Ofdistribution Transformers ( Any Rating ) 45 Supply Of 1100 Grade. Pvc Sheathed Steel Strip Armored, Aluminum Conductorlt Xlpe Insulated Cable Size 46 3.5 Cx240 Sq Mm. Xlpe 47 3.5 Cx120 Sq Mm. Xlpe 48 3.5 Cx70 Sq Mm. Xlpe 49 Supply Of Cable End Termination Using Total Double Compersation Brassglands And Crimping Type Aluminum Thimbles Size For L.T. Cables. 50 3.5 Cx240 Sq Mm. Xlpe 51 3.5 Cx120 Sq Mm. Xlpe 52 3.5 Cx70 Sq Mm. Xlpe 53 Supply Ofhdpe Pipe 110 Mm Dia To Be Laid By Horizontal Drilling For Under Ground Piping ( Trenchless ) At Road Cross Of Above Cable. 54 Supply Of Gi Pipe For External Area Of Small Cable To Houses 55 50Mm Dia 56 40 Mm Dia 57 Supply Of Pvc Pipe Heavy Gauge 40 Mm Dia ( Under Ground Area ) Pipe For Small Cable To Houses 58 Supply Of G.I. Strip Of Size 25X3 Sqmm For Making Connection Between Type-B / C Panel And Earth Rod 59 Supply Oftype Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 1000 & 630 Kva ( Type A-1 ) Incomer - 1 No. 1250 Amp. Tp Mdo Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ( Outgoing - 4 Sets Of 400 Amp. Tp Mccb With Spreader & Extended Handle ) ( 2 Sets Of 250Amp. Tp Mccb With Spreader & Extended Handle ) ( 2 Sets Of 100 0Amp. Tp Mccb With Spreader & Extended Handle ) 60 Supply Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubicle Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 400 Kva ( Type A-2 ) ( Incomer - 1 Set Of 800 Amp.Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ( Outgoing - 6 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle ( 5No.+1No. Capacitor Panel ) ) ( 2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle ) 61 Supply Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mmhinged Door Including Suitable Foundation, Main Lt Panel At Substation- 250 Kva ( Type A-3 ) ( Incomer - 1 Set Of 630 Amp. Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ) ( Outgoing - 5 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle ( 4No.+1No. Capacitor Panel ) ) ( 2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle ) 62 Supply Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 160 Kva ( Type A-4 ) ( Incomer - 1 Set Of 400 Amp. Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ( Outgoing - 4 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle ( 3No.+1No. Capacitor Panel ) ) ( 2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle ) 63 Supply Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 400 Amp. Aluminum Bus Bar ( Type B-1 ) With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) Having : 1 No Incomer 250Amp. Tp Mccb And 6 No.Out-Going 100 Amp. Tp Mccb With Spreader & Extended Handle. 64 Supply Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 300 Amp. Aluminum Bus Bar ( Type B-2 ) With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) Having :1 No Incomer 250Amp. Tp Mccb And 5 No.Out-Going 100 Amp. Tp Mccb Spreader & Extended Handle. 65 Supply Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 300 Amp. Aluminum Bus Bar ( Type B-3 ) With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) Having :1 No Incomer 250 Amp. Tp Mccb And 4 No.Out-Going 100Amp. Tp Mccb Spreader & Extended Handle. 66 Supply Of Lockable Distribution Box Along Withbar Lock Of Size 450X450mm Including Suitable Foundation With Bus Baramp. 140Tpn To Feed Up To 10 Houses ( Type C ) . Panel To Be Made Of 2Mm. Crca Sheet 67 Supplyof Gi Pipe Of 40 Mm Dia Under Ground ( For Street Light ) 68 Supply Junction Box On Stp / Pcc Pole With 900 Mm Long Gi Pipe 25 Mm Dia With Clamp ( For Street Light Connection ) 69 Supply Ofgi Pipe 40Mm Dia B-Class 40 Feet Longfor Earthing Of Type A And B Panels 70 Supply Of G.I . Pipe Chemical Earthing ( Electrode 3 Mtr Long 80 Mm Inner Dia Along With Chemical Powder ) 71 Supply Of G.I.Strip Of Size 50X6mmfor Connecting The Panels A& B Type Panels. 72 Supply Of M.S Flat Of Size 25X3mmfor Connecting The Panels C- Type Panels. 73 Supply Of Steel Structure Of Size 65X65x6 Mm ( M.S. Angle ) 74 Supply Of Single Phase Polycarbonate Meter Box 75 Supply Of Three Phase Polycarbonate Meter Box 76 Supply Of 11 Kvcapacitor Bank Including Mounting Steel Galvanised Structure And Accessories As Required As Per Detailed Technical Specifications, Drawing And Scope Of Works In Following Arrangements: 77 Capacitor Bank 1200 Kvar - Auto Type Substation Mounted With All Associated Equipment Like 11 Kv Vcb Along With Adapter Panel / Complete Mechanism For Connection With Existing Busbar, C&R Panel, Cts, 11 Kv 200A Isolators With Earth Switch, Rvt, 11 Kv Station Class La, Red Oxide / Aluminium Painting, 2.5 Sq.Mm. Pvc Armoured Stranded Copper Control Cables, Protection Circuit And Equipment, Earthing, 16 Mm Dia Ms Nuts & Bolts Etc As Required As Per Approved Technical Specifications, Drawing And Scope Of Works 78 Capacitor Bank 1500 Kvar - Auto Type Substation Mounted With All Associated Equipment Like 11 Kv Vcb Along With Adapter Panel / Complete Mechanism For Connection With Existing Busbar, , C&R Panel, Cts, 11 Kv 200A Isolators With Earth Switch, Rvt, 11 Kv Station Class La, Red Oxide / Aluminium Painting, 2.5 Sq.Mm. Pvc Armoured Stranded Copper Control Cables, Protection Circuit And Equipment, Earthing, 16 Mm Dia Ms Nuts & Bolts Etc As Required As Per Approved Technical Specifications, Drawing And Scope Of Works 79 Supply Of 11 Kv Acs Dog Covered Conductor With All Accessories. 80 Erection Part 81 Armoured Consumer Cabling In High Loss Areas 82 Erection / Laying Of 1.1_Kv Xlpe Insulated Pvc Sheathed Armoured Aluminum Cablefrom Exisitng Lt Line / Pole To Consumer Meter Including Proper Lugging. 83 2Cx6 Sqmm 84 2Cx10 Sqmm 85 4Cx16 Sqmm 86 4Cx25 Sqmm 87 Replacement Of Bare Conductors / Damaged A.B. Cable With Ab Cables 88 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 89 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 90 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock / Mettalic Road / Rcc / Khranjaas Per Scope Of Work, Approved Drawings And Specifications: 91 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 92 Erection Of Following Types Of Poles For Lt Overhead Line By Providing And Installingred Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Or / And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc As Per Scope Of Work, Approved Drawings And Specifications: 93 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) Cement Concreting 0.5 Cmt 94 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 95 Normal Soil 96 Soft Rock Soil / Soft Rock / Mettalic Road / Rcc / Kharanja 97 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 2 Nos. ) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips ( 1:3:6 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 98 Dismantling / Removal Of Existing Lt Bare Conductor Line Or Damaged A.B. Cable & Fixtures Including Damaged Poles, Depositing To Stores Of Employer And Erection, Testing & Commissioning Of New Aerial Bunched Xlpe Cable, Tension Clamps For Dead End, Suspension Clamps, Clamps For Neutral, Piercing Connectors Type-I & Type-Ii, 16 Mm Dia Ms Nuts & Bolts, Pole Clamps, Etc. As Required As Per Technical Specification, Approved Drawings And Scope Of Work: 99 Erection Of Aerial Bunched Xlpecable 3X95+1X70+1X16 Sqmm With All Assecessiories. 100 Erection Of Aerial Bunched Xlpecable 3X120+1X70+1X16 Sqmm With All Assecessiories. 101 Erection Of Aerial Bunched Xlpecable 3X150+1X120+1X16 Sqmm With All Assecessiories. 102 Erection Of Single Phase Distribution Box With Clamps, Lug And All Accessories. 103 Erection Of Three Phase Distribution Box With Clamps Lug And All Accessories. 104 Erection, Testing & Commissioning Of Earthing By Inserting Gi Earthing Spike 2540 Mm Long Made Of 20Mm Solid Rod As Per Approved Drawings, Scope Of Work And Technical Specifications 105 Erection, Testing & Commissioning Of Earthing Coil 106 Erection Of 6 Swg Gi Wire For Earthing By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc As Per Approved Drawings, Scope Of Work And Technical Specifications 107 Shifting Of Existing Consumer Connection From Existing Bare Conductor Line / Damaged A.B. Cable Line To Newly Erected Ab Cable Line 108 Single Phase Connection 109 Three Phase Connection 110 Strengthening Of Existing Damaged Pole By Providing And Welding 1.2Mtr Long 3 No Ms Angle 65*65*6Mm And Carrying Out Required Grouting And Pole Plinth Activities As Per Approved Drawing And Technical Specification. 111 11 Kv Feeder Bifurcation By Constructing 11 Kv Over Head Line 112 Survey, Route Alignment & Pole Spotting, Preparation Of Survey Report And Uploading In The Web Portal After Approval Of Project Manager 113 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 114 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 115 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 116 Excavation Of Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock / Metallic Road / Rcc / Kharanjaas Per Scope Of Work, Approved Drawings And Specifications: 117 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 118 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 119 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Earthing Material ( Coil And 8Swg Gi Wire ) , Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Or / And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc As Per Scope Of Work, Approved Drawings And Specifications: 120 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) Cement Concreting 0.65 Cmt 121 9.5 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 37 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) Cement Concreting 0.5 Cmt 122 Erection, Testing & Commissioning Of Pre-Fabricated Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washers All ( Galvanized ) Including Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. 123 Earthing Arrangement As Per Technical Specificatons, Approved Drawings And Scope Of Work. 124 Excavation, Erection, Testing & Commissioning Of Spike Earthing Of 2540 Mm Long With 20Mm Solid Rod 125 Excavation, Erection, Testing & Commissioning Of Earthing Coil 126 Erection Of 8 Swg Gi Wire For Earthing And Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc 127 Erection Of 6 Swg Gi Wire For Earthing And Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc 128 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 129 Normal Soil 130 Soft Soil / Soft Rock / Metallic Road / Rcc / Khranja 131 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 2 Nos. ) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips ( 1:3:6 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 132 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 133 11 Kv Pin Insulator With Gi Pin 134 11 Kv Disc Insulator 70Kn With Strain Hardware 135 Laying Out, Tensioning, Binding Of Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 136 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog 137 Erection Of 12 Kv, 1600 A, 350Mva, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breaker Along With 12 Kv, 1-Phase, 400-200 / 5-5 3 Nos Indoor Type Current Transformer, Indoor Mounting Type Control Panel For Feeder Protection, Control Cabling Between Vcb And Indoor Control Panel ( Scada Compatible & 61850 Protocol Compliant Protection Relays ) And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, 3-Phase Electronic Energy Meter, Relay & Accessories Complete For Feeder Breaker Protection Along With Adapter Panel / Complete Mechanism To Connect With Existing Busbaras Per Technical Specifications, Approved Drawings And Scope Of Works . 138 11 Kv Feeder Bifurcation By Laying Under Ground Cable 139 Survey, Route Alignment & Pole Spotting And Detection Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departments With The Help Of Utilitiy Dectector Andpreparation Of Survey Report And Uploading In The Web Portal After Approval Of Project Manager. 140 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 141 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 142 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock / Soft Rock / Mettalic Road / Rcc / Khranjaas Per Scope Of Work, Approved Drawings And Specifications: 143 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 144 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Earthing Material ( Coil And 8Swg Gi Wire ) , Red Oxide & Aluminium Paint, Pole Numbering Including Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Or / And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc As Per Scope Of Work, Approved Drawings And Specifications: 145 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) Cement Concreting 0.65 Cmt 146 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 147 Normal Soil 148 Soft Rock Soil / Soft Rock / Mettalic Road / Rcc / Khranja 149 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 2 Nos. ) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips ( 1:3:6 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 150 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 151 11 Kv Pin Insulator With Gi Pin 152 11 Kv Disc Insulator 70Kn With Strain Hardware 153 Erection, Testing & Commissioning Of Pre-Fabricated Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washers Including Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. 154 Earthing Arrangement As Per Technical Specificatons, Approved Drawings And Scope Of Work. 155 Excavation, Erection, Testing & Commissioning Of Spike Earthing Of2540 Mm Long With 20Mm Solid Rod 156 Excavation, Erection, Testing & Commissioning Of Earthing Coil 157 Erection Of 8 Swg Gi Wire For Earthing And Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc 158 Laying Of 11Kv Cable Through Hdd Method ( Including Cable Length Mounted Upto Pole Top Minus Cable Length Laid Inside G.I. Pipe ) Including Digging Of Pit 159 Digging Of Trench .6 Mtr Wide .9 Mtr To 1.5 Mtr Deep For Laying Of Pipe And Cable 160 Normal Soil 161 Soft Rock / Kharanja 162 Hard Rock / Metallic Road / Rcc 163 Laying Of Gi Pipe 6" Dia In Above Digged Trench And Also For Raising Cable On Double Pole / Structure Laying Of 11 Kv Cable 3X185 Sqmm 164 Laying Of 11 Kv Cable Through Above Pipe 165 Laying Of Cable In Above Digged Trench And Also Mounting Upto Line By Using Bricks / Sand &Stone Pad As Per Rec Norms 166 Making Andmounting Of Heat Shrinkable Jointing Kit Outdoor / Indoor For 11 Kv 3X185 Sqmm Xlpe Cable 167 Digging Suitable Pit And Making Straight Through And Joint 11 Kv 3X185 Sqmm 168 Making Of Straight Through Joint And Construction Of Rb Pit 3X1x1 Mtr. With 9 Inch Thick Side Wall And 6 Inch Thick Rcc Bed Along With Rcc Trench Cover In Three Parts Duly Plastered And Finsihed For Housing St. Through Joint. Box And Filled With Sand. 169 Road Restoration Charges Against Thepermission From Concerning Department Like Nagar Nigam, Pwd, Nhai Etc 170 Normal Soil 171 Soft Rock / Khranja 172 Hard Rock / Metallic Road / Rcc 173 Erection Of 12 Kv, 1600 A, 350Mva, 25Ka For 3 Seconds, 3-Ph, Indoor Typevacuum Circuit Breaker Along With 12 Kv, 1-Phase, 400-200 / 5-5 3 Nos Indoor Type Current Transformer, Indoor Mounting Type Control Panel For Feeder Protection, Control Cabling Between Vcb And Indoor Control Panel ( Scada Compatible & 61850 Protocol Compliant Protection Relays ) And Required Accessories, Bi-Metallic Clamps, A-Meter, Volt-Meter, 3-Phase Electronic Energy Meter, Relay & Accessories Complete For Feeder Breaker Protection Along With Adapter Panel / Complete Mechanism To Connect With Existing Busbaras Per Technical Specifications, Approved Drawings And Scope Of Works . 174 Conversion Of Exisiting Lt Bare Conductor Line Into Lt Under Ground Network. 175 Erection Ofl.T Aluminum Armored Xlpe Single Core Cable 176 Installation Of L.T Aluminum Armored Xlpe Single Core Cable Size 1X630 Sq Mm. 177 Installation Of L.T Aluminum Armored Xlpe Single Core Cable Size 1X400 Sq Mm. 178 Al Crimping Lugs ( 630 / 400 / 240 / 120 / 70 ) Sq Mm. 179 Erectionof Cable End Termination Using Total Double Compersation Brassglands And Crimping Type Aluminum Thimbles Size 180 3.5 Cx240 Sq Mm. Xlpe 181 3.5 Cx120 Sq Mm. Xlpe 182 3.5 Cx70 Sq Mm. Xlpe 183 Laying, Testing And Commissioning Of 1100 Volts Grade, Pvc Sheathed Steel Strip Armored Aluminum Conductor Lt Xlpe Insulated Cable Of Sizes 3.5 Cx70 / 3.5 Cx120 / 3.5 Cx240 Sq Mm.To Be Laid Under Ground In Hdpe Pipes 184 Digging Of Trenchbymaking Pits After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying Of Cables Of Size 3.5 Cx70 / 3.5 Cx120 / 3.5 Cx240 Sq Mm. Xlpe By Manual Drill ( By Making Moles ) 185 Digging Of Trenchbymaking Pits After Due Survey With The Help Of Utility Detector Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departmentand Laying Of Cables Of Size 3.5 Cx70 / 3.5 Cx120 / 3.5 Cx240 Sq Mm. Xlpe Through Hdd Method With The Help Of Hdd Machine 186 Digging Of Trench By Open Trench Method After Due Survey With The Help Of Utility Dectector Of Existing / Telephonic Cable And Other Utilites Of Public Utilites Departmentand Laying Of Cables Of Size 3.5 Cx70 / 3.5 Cx120 / 3.5 Cx240 Sq Mm. Xlpe 187 Back Filling And Restoring The Road To Make As Original Including Supply Of All Material And Row Permission Required From The Land Owner Authority ( Nagar Nigam, Pwd, Nhai Etc ) For All L.T. Cables, Pipe And Service Cables Concerned With A Single D.T. 188 Laying Of Hdpe Pipe Of Various Sizes By Horizontal Drilling For Under Ground Piping ( Trenchless ) For Above Cable At Road Crossing Min. Depth Of Pipe Shall Be 1.5 Mtr. Below Surface 110 Mm. Dia. 189 Laying Of Gi Pipe Of 50Mm Dia ( External Area ) 190 Laying Of Gi Pipe Of 40Mm Dia ( External Area ) 191 Laying Of Pvc Pipe Heavy Gauge 40 Mm Dia ( Under Ground Area ) 192 Erection Of G.I. Strip / M.S. Strip Of Size 25X3 / 50X6 Sqmm Connecting Type A / B / C Pannel With Spike Rod / Chemical Earthing / Deep Bore Earthing Arrangement Including Required Bolting / Welding 193 Dismantling Of Existing Lt Overhead Line Including Stp Poles, Bare Conductor / A.B. Cable, Pole Accessories And Transportation Of Dismantled Materials To Kesco Store. 194 Laying Of Aluminum Armored Xlpes Cables Size 2X6 Sq Mm. Upto Consumer Meter 195 Laying Of Aluminum Armored Xlpes Cables Size 2X10 Sq Mm. Upto Consumer Meter 196 Laying Of Aluminum Armored Xlpes Cables Size 4X16 Sq Mm. Upto Consumer Meter 197 Laying Of Aluminum Armored Xlpes Cables Size 4X25sq Mm. Upto Consumer Meter 198 Installation, Testing & Commissioning Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mmhinged Door Including Suitable Foundation, Main Lt Panel At Substation- 1000 & 630 Kva ( Type A-1 ) Incomer - 1 No. 1250 Amp. Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ( Outgoing - 4 Sets Of 400 Amp. Tp Mccb With Spreader & Extended Handle ) ( 2 Sets Of 250Amp. Tp Mccb With Spreader & Extended Handle ) ( 2 Sets Of 100 0Amp. Tp Mccb With Spreader & Extended Handle ) 199 Installation, Testing & Commissioning Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubicle Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2Mmcrca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 400 Kva ( Type A-2 ) ( Incomer - 1 Set Of 800 Amp.Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ( Outgoing - 6 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle ( 5No.+1No. Capacitor Panel ) ) ( 2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle ) 200 Installation, Testing & Commissioning Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2Mm Sheet Steel & Provided With2mmhinged Door Including Suitable Foundation, Main Lt Panel At Substation- 250 Kva ( Type A-3 ) ( Incomer - 1 Set Of 630 Amp. Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ) ( Outgoing - 5 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle ( 4No.+1No. Capacitor Panel ) ) ( 2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle ) 201 Installation, Testing & Commissioning Of Outdoor Type Lt Distribution Box With A Rupturing Capacity Of 50 Ka At 415 Volt Called For Individual Items ( Cpri Approved Manufacturer ) Openable In Front & Back Suitable For 3 Phase, Four Wire, 50 Hz Ac Supply & An Ambient Temperature Of 45 Deg. C. The Cubical Should Be Weather Proof, Dust Proof, Bremen Proof And In Closer Protection Shall Be Ip-65 As Per Is 2147- 1962 And Is-8623 The Panels & Switches Boards Shall Be Fabricated Out Of 2 Mm Crca Sheet Steel & Provided With 2 Mm Hinged Door Including Suitable Foundation, Main Lt Panel At Substation- 160 Kva ( Type A-4 ) ( Incomer - 1 Set Of 400 Amp. Acb With Inbuilt Mpr Released With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) With Control Mcbs ) ( Outgoing - 4 Sets Of 250 Amp. Tp Mccb With Spreader & Extended Handle ( 3No.+1No. Capacitor Panel ) ) ( 2 Sets Of 100 Amp. Tp Mccb With Spreader & Extended Handle ) 202 Installation, Testing & Commissioning Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 400 Amp. Aluminum Bus Bar ( Type B-1 ) With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) Having : 1 No Incomer 250Amp. Tp Mccb And 6 No.Out-Going 100 Amp. Tp Mccb With Spreader & Extended Handle. 203 Installation, Testing & Commissioning Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 300 Amp. Aluminum Bus Bar ( Type B-2 ) With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) Having :1 No Incomer 250Amp. Tp Mccb And 5 No.Out-Going 100 Amp. Tp Mccb Spreader & Extended Handle. 204 Installation, Testing & Commissioning Of Outdoor Type Feeder Pillar Panel To Be Made Of 2Mm. Crca Sheet & Covers Will Be 2 Mm Crca Sheet Duly Powder Coated Paint Including Suitable Foundation With 300 Amp. Aluminum Bus Bar ( Type B-3 ) With ( On / Off Indicating Light ) ( Metering On Incomer- 1 Set Of Digital Ammeter With Ass ) ( 1 Set Of Digital Voltmeter With Vss ) ( 1 Set Of Led Type Phase Indication Light ( 22.5 Mm ) Having :1 No Incomer 250 Amp. Tp Mccb And 4 No.Out-Going 100Amp. Tp Mccb Spreader & Extended Handle. 205 Installation, Testing & Commissioning Of Lockable Distribution Box Along With Bar Lock Of Size 450X450 Mm Including Suitable Foundation With Bus Bar 140 Amp. Tpn To Feed Up To 10 Houses ( Type C ) .Panel To Be Made Of 2Mm. Crca Sheet 206 Installation Of2x10 Sq Mm. Xlpe Cable ( For Street Light ) 207 Installation And Laying Of Gi Pipe Of 40 Mm Dia Under Ground ( For Street Light ) 208 Installation Of Junction Box On Stp / Pcc Pole With 900 Mm Long Gi Pipe 25 Mm Dia With Clamp ( For Street Light Connection ) 209 Boring Upto 39 Feet And Erection Of Gi Pipe 40Mm Dia B-Class 40 Feet Long For Connection With Type-A And B Panel Along With Supply Of G.I. Strip Of Size 50X6 Sqmm 210 Erection / Pegging Of M.S.Earth Spike Rod 2540X20 Mm 211 Erection Of G.I. Pipe Chemical Earthing Electrode 3 Mtr Long 80 Mm Inner Dia Along With Chemical Powder 212 Preparation And Submission Of 2 Sets Of Detailed Printed Drawing / Auto Cad Drawing / Pdf ( Along With Digital Copy ) Of L.T. Network Of Each D.T. Depicting Location Of L.T. Cables And All Panels ( Type-A, B And C ) And Separate List For All Connections On Type C Panels In Excel Format 213 Erection Of Single Phase Poly Carbonate Meter Box After Removal Of Existing Meter Box And Connections Of Meters With Armoured Cable Laid Along With Resealing Of Meter With Seals Provided By Kesco 214 Erection Of Three Phase Poly Carbonate Meter Box After Removal Of Existing Meter Box And Connections Of Meters With Armoured Cable Laid Along With Resealing Of Meter With Seals Provided By Kesco 215 Reconductoring Of 11 Kv Oh Line. 216 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 217 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 218 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock / Soft Rock / Mettalic Road / Rcc / Khranjaas Per Scope Of Work, Approved Drawings And Specifications: 219 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 220 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Earthing Material ( Coil And 8Swg Gi Wire ) , Red Oxide & Aluminium Paint, Pole Numbering Excluding Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Or / And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc As Per Scope Of Work, Approved Drawings And Specifications: 221 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) Cement Concreting 0.65 Cmt 222 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 223 Normal Soil 224 Soft Rock Soil / Soft Rock / Mettalic Road / Rcc / Khranja 225 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 2 Nos. ) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips ( 1:3:6 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 226 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 227 11 Kv Pin Insulator With Gi Pin 228 11 Kv 70Kn Disc Insulator With Strain Hardware 229 Dismantling Of Existing Overhead Line Conductor & Fittings And Depositing To Kesco Store, Laying Out, Tensioning, Binding Of New Conductor And Tightening Of Stays And Stringing, Testing And Commissioning Of Acsrconductor Of Following Sizes Including Jointing Sleeves, Helical Formed Fittings, Jumpering And By Providing & Erecting Pg Clamps Etc As Required As Per Approved Drawings, Scope Of Work And Technical Specifications 230 6 / 4.72 Mm+7 / 1.57 Mm ( 100 Mm² Al. Area ) - Dog By Replacing Existing Racoon / Rabbit Condcutor 231 Erection, Testing & Commissioning Of Pre-Fabricated Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washers All Galvanized Including Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. 232 Earthing Arrangement As Per Technical Specificatons, Approved Drawings And Scope Of Work. 233 Excavation, Erection, Testing & Commissioning Of Spike Earthing Of 2540 Mm Long With 20Mm Solid Rod 234 Excavation, Erection, Testing & Commissioning Of Earthing Coil 235 Erection Of 8 Swg Gi Wire For Earthing And Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc 236 Strengthening Of Existing Damaged Pole By Providing And Welding 1.2Mtr Long 3 No Ms Angle 65*65*6Mm And Carrying Out Required Grouting And Pole Plinth Activities As Per Approved Drawing And Technical Specification. 237 Reconductoring Of 11 Kv Ug Line. 238 Survey, Route Alignment & Pole Spotting And Detection Of Existing Electrical / Telephonic Cable / And Other Utilites Of Public Utilites Departments With The Help Of Utilitiy Dectector Andpreparation Of Survey Report And Uploading In The Web Portal After Approval Of Project Manager. 239 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Normal Soil As Per Scope Of Work, Approved Drawings And Specifications: 240 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 241 Excavation Of Additional Pole Pit ( Of Depth 1 / 6Th Of Pole Length ) In Soft Rock / Soft Rock / Mettalic Road / Rcc / Khranjaas Per Scope Of Work, Approved Drawings And Specifications: 242 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) 243 Erection Of Following Types Of Poles For 11 Kv Overhead Line By Providing And Installing Danger Plate, Anti-Climbing Devices ( Barbed Wire ) , Earthing Material ( Coil And 8Swg Gi Wire ) , Red Oxide & Aluminium Paint, Pole Numbering Excluding Cement Concrete Foundation Or Refilling By Bolders Using Cement Concreting Foundation 1 Part Cement, 2 Part Sand, 4 Part 40 Mm Size Stone Aggregate Chips ( 1:2:4 ) Or / And 200 Mm Average Size Bolders Mixed With Excavated Earth Etc As Per Scope Of Work, Approved Drawings And Specifications: 244 11 M Long Steel Tubular Poles With Welded Steel Base Plate Of Designation 410 Sp 55 ( Is 2713, Pt I, Ii, Iii 1980 ) And Bottom Galvanized As Peris 2629 ( 1985 ) Cement Concreting 0.65 Cmt 245 Excavation Of Stay Pit In Following Type Of Soils, As Per Scope Of Work, Approved Drawings And Specifications: 246 Normal Soil 247 Soft Rock Soil / Soft Rock / Metallic Road / Rcc / Kharanja 248 Erection Of Complete Stay Set With Gi Stay Wire ( 7X3.15 Mm Dia ) , Binding Of Stay Wire, By Providing Guy Stay Insulator ( 2 Nos. ) And 0.2 Cmt Concreting 1 Part Cement, 3 Part Sand, 6 Part 40 Mm Size Stone Aggregate Chips ( 1:3:6 ) As Per Technical Specifications, Approved Drawings And Scope Of Works. 249 Erection, Testing And Commissioning Of 11 Kv Insulator Including Their Hardware Fittings As Per Technical Specification, Approved Drawings And Scope Of Work. 250 11 Kv Pin Insulator With Gi Pin 251 11 Kv Disc Insulator 70 Kn With Strain Hardware 252 Erection, Testing & Commissioning Of Pre-Fabricated Steel Items Like V Cross Arm, Top Clamp, Dc Cross Arm, Bracket, Clamps, Cross Bracings, Bracings, Strain Plate, Guarding Channels, Back Clamp, Etc Made Of Ms Channels, Ms Angle, Ms Flats Of Given Sizes For Over Head Structures And Ms Nuts, Bolts & Washers Duly Galvanizedincluding Painting By Red Oxide & Aluminium Paint As Per Technical Specification, Approved Drawings And Scope Of Work. 253 Earthing Arrangement As Per Technical Specificatons, Approved Drawings And Scope Of Work. 254 Excavation, Erection, Testing & Commissioning Of Spike Earthing 2540 Mm Long With 20Mm Solid Gi Rod 255 Excavation, Erection, Testing & Commissioning Of Earthing Coil 256 Erection Of 8 Swg Gi Wire For Earthing And Guarding By Providing Gi Nut, Bolts & Washers, Turn Buckle Etc 257 Laying Of 11Kv Cable Through Hdd Method Including Digging Of Pit 258 Digging Of Trench .6 Mtr Wide .9 Mtr To 1.5 Mtr Deep For Laying Of Pipe And Cable 259 Normal Soil 260 Soft Rock / Kharanja 261 Hard Rock / Metallic Road / Rcc 262 Laying Of Gi Pipe 6" Dia In Above Digged Trench And Also For Raising Cable On Double Pole / Structure Laying Of 11 Kv Cable 3X185 Sqmm 263 Laying Of 11 Kv Cable Through Above Pipe 264 Laying Of Cable In Above Digged Trench And Also Mounting Upto Line By Using Bricks / Sand &Stone Pad As Per Rec Norms 265 Making Andmounting Of Heat Shrinkable Jointing Kit For 11 Kv 3X185 Sqmm Xlpe Cable 266 Digging Suitable Pit And Making Straight Through Joint 11 Kv 3X185 Sqmm 267 Making Of Straight Through Joint Andconstruction Of Rb Pit 3X1x1 Mtr. With 9 Inch Thick Side Wall And 6 Inch Thick Rcc Bed Along With Rcc Trench Cover In Three Parts Duly Plastered And Finsihed For Housing St. Through Joint. Box And Filled With Sand. 268 Road Restoration Charges 269 Normal Soil 270 Soft Rock / Kharanja 271 Hard Rock / Metallic Road / Rcc 272 Installationof 11 Kvcapacitor Bank Including Mounting Steel Galvanised Structure And Accessories As Required As Per Detailed Technical Specifications, Drawing And Scope Of Works In Following Arrangements: 273 Capacitor Bank 1200 Kvar - Auto Type Substation Mounted With All Associated Equipment Like 11 Kv Vcb Along With Adapter Panel / Complete Mechanism For Connection With Existing Busbar, C&R Panel, Cts, 11 Kv 200A Isolators With Earth Switch, Rvt, 11 Kv Station Class La, Red Oxide / Aluminium Painting, 2.5 Sq.Mm. Pvc Armoured Stranded Copper Control Cables, Protection Circuit And Equipment, Earthing, 16 Mm Dia Ms Nuts & Bolts Etc As Required As Per Approved Technical Specifications, Drawing And Scope Of Works 274 Capacitor Bank 1500 Kvar - Auto Type Substation Mounted With All Associated Equipment Like 11 Kv Vcb Along With Adapter Panel / Complete Mechanism For Connection With Existing Busbar, , C&R Panel, Cts, 11 Kv 200A Isolators With Earth Switch, Rvt, 11 Kv Station Class La, Red Oxide / Aluminium Painting, 2.5 Sq.Mm. Pvc Armoured Stranded Copper Control Cables, Protection Circuit And Equipment, Earthing, 16 Mm Dia Ms Nuts & Bolts Etc As Required As Per Approved Technical Specifications, Drawing And Scope Of Works 275 Erection Of 11 Kv Xlpe Insulated 3X185 Sqmm Armoured 276 Erection Of Heat Shrinkable Jointing Kit For 11 Kv 3X185 Sqmm Xlpe Cable 277 Heat Shrinkable Jointing Kit For 11 Kv 3X185 Xlpe Cable-Indoor / Outdoor Termination Kit 278 Layingof11 Kv Acs Dog Covered Conductor With All Accessories.
|