Quotation Are Invited For Palm Jumeira Ro Plant Fire Fighting Pump Control System 1 Introduction General Requirement 1 1 Palm Jumeira Ro Plant Fire Fighting Pump Control System Is Not In Service Since Handover Of The Plant To Dewa There Are Faults Persisting At The Main Fire Pump Control Panel Although Its Standby Pump Control Panel Is H Ealthy This Enquiry Is Intended To Rectify The Existing Faults And Get Recommended Spares List With Prices From The Oem Agent 1 2 The Prospective Oem Agent May Visit The Site To Understand The Scope For Fault Rectification Works For The Palm Jumeira Ro Plant Mai N Fire Pump Control Panel Plant Site Visit And Correspondence Shall Be Communicated By Email To Mr Firoz Ahmed Deputy Manager Em G Firoz Ahmed Dewa Gov Ae With Copy To Mr Ramasubramanian T S Manager Em G Ramasubramanian Dewa Gov Ae The Contractor May Con Tact With Mr Firoz Ahmed Mob 050 4238725 0505562685 2 Scope Of Work 2 1 Checking And Rectification Of The Following Faults A Phase Failure And Overvoltage Alarm Leds Solid Red Vab 996 Vac Vbc 1001 Vac Ac 430Vac Whereas Actual Voltage Is 415Vac B Ove R Frequency Alarm On Display Found Over Frequency 99 Hz System Frequency Is 50 Hz C Display Screen Scrolling Continuously During Navigation By Up Down Buttons At Him Membrane D Leds On Display Not Functioning During Lamp Test E Common Alarm And Phase Failu Re Alarm Not Activating At Input Output Io Board F Any Other Faults Other Than The Above Ones 2 2 Supply And Fixing Of Spares As Required If Additional Spares And Services Are Required With Reference To Clause 3 They Shall Be Included In Contractors Scope Without Additional Cost To Dewa 2 3 Submission Of List Of Directly Replaceable Spares With Prices For Next 5 Years 2 4 Service C Harges Shall Be Included In The Offer 3 Price Schedule Spare Parts Sn Pin Number Description Qty Price 1 99 5816 01 Membrane 1 2 99 5835 12 Display Board 1 3 4A55149h02 I O Board 1 4 99 5836 01 Relay Board 1 Service Charges Serial No Descrip Tion 1 Checking Replacement Testing Recommissioning Of The Main Fire Pump Control Panel Components Along With The Firefighting Pumps System To Resume The Operation Of The Panel Shall Be Included 4 General Terms Conditions 1 Existing Control And Pow Er Wiring And Functionality Of The Panels Shall Be Resumed And Shall Not Be Adversely Affected 2 It Is The Contractor S Responsib Ility To Carry Out The Rectification Work Without Additional Charges To Dewa For Extra Material Or Services If Required 3 The Co Ntractor Shall Follow All Dewa Safety Security Environmental Policies Practices During The Entire Execution Period Of The Supp Ly Work 4 The Required Mechanical Testing Programming Tools Instruments Services Etc Are The Scope Of The Contractor 5 Invo Ice Shall Be Submitted To Dewa Finance Department 5 Technical Details Of The Existing Fire Fighting Pump Control Panel Lmr Plus Eaton Cutler Hammer Ref Lmr Electric Fire Pump Controller Ft70 Cat No Ft70 30C L1 2U C1 C3 Site Visit Is Required To Get Mpre D Etails 6 Terms Of Delivery A The Services Shall Be Carried Out At Site Within 30 Days From The Date Of The Order The Works Shal L Be Completed Within 7 Days From The Start Of The Project Site Activities 7 Guarantee Terms A Two Year Guarantee Shall Be Giv En For The Services Provided By Contractor B The Guarantee Will Take Effect From The Date Of Takeover Of The Refurbished Panel C When A Defect Is Noticed On The Refurbished Panel Wirings During The Period Of Warranty The Contractor Must Rectify The Fault With In A Reasonable Amount Of Time Fixed By Dewa With No Claims Or Compensation 5 Terms Of Payment A 100 Of The Order Value Will Be Made Within 30 Days After Successful Completion Of Works Against The Invoice Certified By Dewa Authorized Engineer Representative B Invoice Shall Be Addressed To Dewa Finance Department Qty 1Standard Terms Conditions1 Prices Should Be Ddp Delivery Duty Paid At Dewa Stores 2 Quotation To Be Submitted Only In Local Currency U A E Dirhams3 Dewa Standard Payment Terms Is 30 Days Credit From The Date Of Acceptance Of Material4 No Dewa Staff Or His Or Her Relatives Up To Third Degree Should Have Ownership Or Partnership In Your Company And Your Participation In Dewa Tenders Rfqs Should Not Constitute A Conflict Or Perceived Conflict Of Interest
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 49238745
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.