View Changes Higher Level Contract Quality Requirement Navicp Review Feb 1991 Feb 1999 1 Iso9001 Inspection Of Supplies Fixed Price Aug 1996 2 Inspection And Acceptance Of Supplies 26 Wide Area Workflow Payment Instructions Dec 2018 16 X X X X X X X X Navy Use Of Abilityone Support Contractor Release Of Offeror Information 3 18 1 Warranty Of Data Basic Mar 2014 2 Buy American Free Trade Agreements Balance Of Payments Program Basic Deviation 2020 O0019 Jul 2020 3 Alternate A Annual Representations And Certifications Apr 2020 13 X X X X Annual Representations And Certifications Mar 2020 13 335313 1250 Notice Of Priority Rating For National Defense Emergency Perpardeness And Enrgy Progam Use April 2008 2 X Solicitation Response Date Is Hereby Extended To 12 March 2021 Effective November 30 2020 The Offeror By Submission Of Its Quotation Represents The Following If Dfars Clause 252 204 7012 Safeguarding Covered Defense Information And Cyber Incident Reporting Applies 1 In Accordance With Dfars Provision 252 204 7019 It Has Implemented The Nist Sp 800 171 Security Requirements For Its Information Systems And 2 Its Summary Level Scores Are Posted In The Supplier Performance Risk System Sprs Https Www Sprs Csd Disa Mil In Accordance With Paragraph D Of Dfars Clause 252 204 7020 Nist Sp 800 171 Dod Assessment Requirements Failure To Comply May Result In Cancellation Of Automated Purchase Orders This Solicitation Is Being Issued To Resolicit For Rfq Sprmm1 20 Q Rd89 To Dissolve The Small Business Set Aside Per Dag 19 507 Navsea S9320 Am Pro 020 Mldg R2 Qualification Is Required Solicitation Is Being Issued Under The Special Emergency Procurement Authority Sepa All Contractual Documents I E Contracts Purchase Orders Task Orders Delivery Orders And Modifications Related To This Procurement Are Considered To Be Issued By The Government When Copies Are Either Deposited In The Mail Transmitted By Facsimile Or Sent By Other Electronic Commerce Methods Such As Email The Government s Acceptance Of The Contractor s Proposal Constitutes Bilateral Agreement To Issue Contractual Documents As Detailed Herein In Accordance With Dfar 217 7301 Contractors Shall Identify Their Sources Ofsupply In Contracts For Supplies If The Item Currently Being Procured Is Anon Value Added Item Please Provide Actual Manufacturer Cage Code Address Delivery Lead Time Offer Valid For Days Please Provide Email Address For Follow Up Communications Packaging Location If Different Than Offeror Name Cage Address Notice To Contractor s Providing Surplus Material A Surplus Material Certificate And Label Must Accompany Your Quotation Forsurplus New Surplus New Manufactured Surplus Material All Surplus Materialmust Have Traceability Back To A Government Contract In Order To Be Consideredfor Award Without This Information We Are Unable To Determine When Thegovernment Purchased And Inspected The Item And Therefore We Cannot Be Assured Of Technical Acceptability If Submitting Your Quotation Via Edi A Faxed Or Email Copy Of The Surpluscertificate Along With A Photo Of The Box And Label Must Be Sent To The Buyerasap It Is Recommended That Vendors Provide Contact Information To Navsup Wssmechanicsburg In Order To Receive Automated Notifications From Navy Electroniccommerce Online Neco When Contracts Modifications Are Issued By Dla Maritimemechanicsburg And Posted On Eda To Receive These Notifications Contact Navsup Wss Code 025 Procurement Systems Design And Contract Support Divisionvia Email At Navsupwssitimphelpdesk Navy Mil Please Include The Followinginformation With Your Request Cage Code Company Name And Address And Poc W With Phone Number And Email Address Contractors Can View Their Orders Contracts And Modifications At Theelectronic Document Access Eda Web Tool This Web Tool Is Located At The Wide Area Workflow Wawf Website It Is Recommended That Contractors Register For Eda At Https Wawf Eb Mil Click On New User And Registration This Order Requires A Higher Level Inspection Please Review The Attached Dd1423 For Special Testing Instructions 1 Scope 1 1 This Procurement Specification Contains The Requirements For Manufacture And The Contract Quality Requirements For An Brr 6 Proximity Sensor Seated Switch For Use On Navy Submarines 2 Applicable Documents 2 1 Applicable Documents The Document S Listed Below Form A Part Of This Contract Purchase Order Including Modifications Or Exclusions 2 1 1 Documents Drawings And Publications Supplied Are Listed Under Drawing Number These Items Should Be Retained Until An Award Is Made 2 1 2 Document References Listed Below Must Be Obtained By The Contractor Ordering Information Is Included As An Attachment To This Contract Purchase Order 2 1 3 The Document Changes Section Provides Supersessions Changes To Referenced Documents 2 2 Order Of Precedence In The Event Of A Conflict Between The Text Of This Contract Purchase Order And The References And Or Drawings Cited Herein The Text Of This Contract Purchase Order Shall Take Precedence Nothing In This Contract Purchase Order However Shall Supersede Applicable Laws And Regulations Unless A Specific Exemption Has Been Obtained Drawing Data 8590854 53711 D 0001 49998 0080043 Drawing Data 8590860 53711 A D 0001 A 49998 0155852 Document Ref Data Mil Std 130 N 121116 A 01 Document Ref Data Mil Dtl 915 G 020822 A Document Ref Data Mil Dtl 915 0008 H 020822 A Document Ref Data Mil Std 973 000930 A 04 Document Ref Data Iso 9001 150915 A Document Ref Data Iso 10012 030415 A Document Ref Data Mil M 24041 C 810817 A Document Ref Data Mil Dtl 24231 E 130426 A Document Ref Data Mil I 45208 A 951103 A 2 Document Ref Data Ncsl Z540 3 060803 A Document Ref Data A A 56032 D 030321 A Document Ref Data Electrical Test Procedure A Document Ref Data Sae Ams2817g 11 2016 A Document Ref Data Sae As23053 5A 11 2018 A Document Ref Data S9320 Am Pro 020 Dated 08 1999 02 A Document Ref Data S9320 Am Pro 030 Dated 02 2005 03 A Document Change Data Ams Dtl 23053 5B Sae As23053 5A Document Change Data Ams 2817 Sae Ams2817g Document Change Data Mil C 24231D Mil Dtl 24231E 3 Requirements 3 1 Design And Manufacturing The An Brr 6 Proximity Sensor Seated Switch Furnished Under This Contract Purchase Order Shall Meet The Material Electrical Mechanical Physical And Test Requirements As Specified On Drawings 8590860 Consisting Of Item Numbers 1 Thru 8 And 8590854 Attachment A Electrical Test Procedure Navsea Manuals S9320 Am Pro 030 Mldg And S9320 Am Pro 020 Mldg And Including Associated Specifications Mentioned In This Procurement 3 1 1 As Required By Note 4 Of Drawing 8590860 Item Number 4 Must Be Treated As A Connector When Referencing Drawing 8590854 3 1 2 The Switch Item No 4 Of Drawing 8590860 Surface Preparation Application And Inspection Of Non Conductive Coating Plasma Coating Shall Be In Accordance With Navsea Manual S9320 Am Pro 030 Mldg As Specified On Drawing 8590854 3 1 3 The Polyurethane Molding Compound Type Ii Color Amber Shall Be In Accordance With Mil M 24041 Requirements As Specified On Drawing 8590860 3 1 4 All Outboard Molded Cable Assemblies Shall Be Manufactured And Tested In Accordance With Navsea Manual S9320 Am Pro 020 Mldg Requirements As Specified On Drawings 8590860 Note 3 And 8590854 Note 4 Including Attachment A Electrical Test Procedure 3 2 Vendor Qualification As Required By Drawing 8590854 3 2 1 Only Vendors Which Are Qualified Per The Audit Requirements Of Navsea Manual S9320 Am Pro 020 Mldg Appendix Ii A And Listed On The Approved Vendors Lists In Appendix Ii A Of Navsea Manual S9320 Am Pro 020 Mldg Shall Be Authorized To Fabricate Submarine Outboard Cable Assemblies 3 2 2 Metal Plug Bodies Surface Preparation Is Only By Vendors Which Are Qualified Per Audit Requirements Of Navsea Manual S9320 Am Pro 030 Mldg Appendix Iii H And Listed On The Approved Vendors Lists In Appendix Iii I Of Navsea Manual S9320 Am Pro 030 Mldg Shall Be Authorized To Fabricate Non Conductive Plasma Sprayed Ceramic Coated Submarine Outboard Connector Metal Plug Bodies 3 3 Marking Requirements The Supplier Shall Permanently Mark And Identify Each First Article And Production Lot Unit Proximity Sensor Seated Switch In Accordance With Note 8 Of Drawing 8590860 Per Mil Std 130 Per Note 7 Of Drawing 8590860 The Supplier Shall Contact Jason Krol Jason Krol Navy Mil Of Nswc Philadelphia Division For Component Serial Number Information 3 3 1 The Supplier Shall Mark Tag Or Bag All Piece Parts With Contract Drawing Item Heat Lot Or Batch And Serial Number Per Mil Std 130 Until Installed In The Designated Assembly 3 4 First Article Testing Inspection Supplier Testing Inspection The First Article Testing Inspection Procedure And Approval Are Required For Proximity Sensor Seated Switch Government Approval Is Required Prior To Commencement Of First Article Unit 3 5 Notification The Supplier Shall Notify Naval Surface Warfare Center Philadelphia Division Nswcpd 5001 S Broad Street Philadelphia Pa 19112 1403 By Email Matthew Ogilvie Navy Mil Code 242Mo After Award Of Contract 3 5 1 The Nswcpd Is The Acceptance Activity For The Contract Data Requirements List Dd1423 Data Items Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 3 6 Configuration Control Mil Std 973 Entitled Configuration Management Paragraph 5 4 8 Configuration Control Short Form Procedure Is Hereby Incorporated The Contractor Shall Submit All Engineering Change Proposals In Accordance With Mil Std 973 Paragraph 5 4 8 2 And Appendix D Requests For Deviations Shall Be Processed In Accordance With Mil Std 973 Paragraph 5 4 8 3 And Appendix E Requests For Waivers Shall Be Processed In Accordance With Mil Std 973 Paragraph 5 4 8 4 And Appendix E Original And Two Copies Shall Be Submitted To Contracting Officer Navicp Mech P O Box 2020 Mechanicsburg Pa 17055 0788 3 6 1 Configuration Control When The Contractor Has Received Authorization On A Prior Contract For The Same Nsn For The Use Of A Drawing Of A Later Revision Status That Authorization Is Hereby Extended To All Succeeding Contracts Purchase Orders Until Another Drawing Revision Is Approved The Contractor Will Notify The Pco Of This Occurrence In Each Instance In The Response To The Solicitation Such Notification Shall Be In Writing Setting Forth The Contract Under Which The Prior Authorization Was Granted The Date Of The Granting Of The Authorization And The Name Of The Granting Authority Contractors Shall Also Refer Technical Inquiries Other Than Those Covered By Mil Std 973 On Company Letterhead Signed By A Responsible Company Official With Copies Distributed As Stated Below The Original And Two Copies Of All Contractor Generated Correspondence Regarding Configuration Shall Be Submitted To Contracting Officer Navicp Mech P O Box 2020 Mechanicsburg Pa 17055 0788 Contractors Are Cautioned That Implementing Engineering Changes Waivers Deviations Or Technical Inquiries Into The Contract Purchase Order Without Approval Of The Contracting Officer Will Be At The Sole Risk Of The Contractor 3 7 Mercury Free The Material Supplied Under This Contract Purchase Order Is Intended For Use On Submarines Surface Ships And Therefore Shall Contain No Metallic Mercury And Shall Be Free From Mercury Contamination Mercury Contamination Of The Material Will Be Cause For Rejection If The Inclusion Of Metallic Mercury Is Required As A Functional Part Of The Material Furnished Under This Contract The Contractor Shall Obtain Written Approval From The Procurement Contracting Officer Before Proceeding With Manufacture The Contractor s Request Shall Explain In Detail The Requirements For Mercury Identify Specifically The Parts To Contain Mercury And Explain The Method Of Protection Against Mercury Escape Such A Request Will Be Forwarded Directly To The Procurement Contracting Officer With A Copy To The Applicable Government Inspector Upon Approval By The Contracting Officer The Vendor Will Provide A Warning Plate Stating That Metallic Mercury Is A Functional Part Of The Item And Will Include Name And Location Of That Part The Use Of Mercury Mercury Compounds Or Mercury Bearing Instruments And Or Equipment In A Manner Which Might Cause Contamination In The Manufacture Assembly Or Test Of Material On This Contract Is Prohibited The Most Probable Causes Of Contamination Are Direct Connected Manometers Mercury Vacuum Pumps Mercury Seals Or The Handling Of Mercury In The Immediate Vicinity Mercury Switches Mercury In Glass Thermometers Standard Cells And Other Items Containing Mercury May Be Used If They Are Located So As Not To Constitute A Contamination Hazard If External Contamination By Metallic Mercury Occurs Or Is Suspected The Following Test May Be Used To Determine Whether Contamination By Metallic Mercury Exists Or Whether Corrective Cleaning Measures Have Been Effective Enclose The Equipment In A Polyethylene Bag Or Close Fitting Airtight Container For Eight Hours At Room Temperature 70 Degrees F Minimum Sample The Trapped Air And If Mercury Vapor Concentration Is 0 01 Mg Cu Meter Or More The Material Is Mercury Contaminated Insofar As The Requirements Of This Contract Are Concerned These Requirements Shall Be Included In Any Subcontract Or Purchase Order Hereunder And The Contractor Shall Insure Subcontractor Compliance With These Requirements Technical Questions Pertaining To These Requirements Shall Be Referred To The Procurement Contracting Officer Via The Cognizant Administrative Contracting Officer For Background The Following Information Is Provided Mercury Is Corrosive To Gold Silver Nickel Stainless Steels Aluminum And Copper Alloys Stainless Steels Nickel And Copper Alloys Are Widely Used In Reactor Plants And Other Submarine Surface Ship Systems Accidental Trapping Of Mercury In A Component Could Cause Serious Damage To Vital Parts Mercury Is Also Toxic If Inhaled Ingested Or Absorbed Through The Skin It Is Evident That Grave Consequences Could Result From Small Amounts Of Mercury Vapor Present In An Unreplenished Submarine Surface Ship Atmosphere 4 Quality Assurance 4 1 Responsibility For Inspection Unless Otherwise Specified In The Contract Purchase Order The Contractor Is Responsible For The Performance Of All Inspection Requirements As Specified Herein Except As Otherwise Specified In The Contract Purchase Order The Contractor May Use His Own Or Any Other Facilities Suitable For The Performance Of The Inspection Requirements Specified Herein Unless Disapproved By The Government The Government Reserves The Right To Perform Any Of The Inspections Set Forth In The Specification Where Such Inspections Are Deemed Necessary To Assure Supplies And Services Conform To Prescribed Requirements 4 1 1 Suppliers Currently Using And Maintaining Inspection System Requirements To Mil I 45208 Are Granted Permission To Utilize This If Desired 4 2 Responsibility For Compliance All Items Must Meet All Requirements Of This Contract Purchase Order The Inspection Set Forth In This Specification Shall Become A Part Of The Contractor s Overall Inspection System Or Quality Program The Absence Of Any Inspection Requirements Shall Not Relieve The Contractor Of The Responsibility Of Assuring That All Products Or Supplies Submitted To The Government For Acceptance Comply With All Requirements Of The Contract Purchase Order Sampling In Quality Conformance Does Not Authorize Submission Of Known Defective Material Either Indicated Or Actual Not Does It Commit The Government To Acceptance Of Defective Material 4 3 Records Records Of All Inspection Work By The Contractor Shall Be Kept Complete And Available To The Government During The Performance Of Contract Purchase Order And For A Period Of 365 Calendar Days After Final Delivery Of Supplies 4 4 Quality System Requirements The Supplier Shall Provide And Maintain A Quality System Acceptable To The Government The Quality System Requirements Shall Be In Accordance With Iso 9001 4 5 Inspection System The Supplier s Quality Inspection System Shall Be In Accordance With Mil I 45208 Or Iso 9001 And Ncsl Z540 3 Or Iso 10012 The Supplier Shall Develop And Submit Their Written Quality Inspection And Test Plan As Indicated On The Contract Data Requirements List Dd Form 1423 Government Approval Of The Supplier s Written Quality Inspection And Test Plan Is Required By The Contract Cdrl Quality Inspection Amp Test Plan Per Mil I 45208 Ncsl Z540 3 And Di Qcic 81110 4 6 Finished Edges Finished Shall Be In Accordance With The Applicable Drawing Requirements 4 7 Material Control The Supplier Shall Have An Effective Material Control System That Provides For The Control Of Materials By Heat Lot Or Batch As Ordered For First Article And Production Lot Units 4 8 First Article Testing Inspection Supplier Testing Inspection The Suppliershall Perform First Article Testing Inspection On Proximity Sensor Seated Switch In Accordance With The Applicable Drawings Specifications Attachment A Electrical Test Procedure Navsea Manuals S9320 Am Pro 030 Mldg And S9320 Am Pro 020 Mldg And Their Approved First Article Procedure 4 8 1 The First Article Inspection Shall Be Made By The Cognizant Dcma Qar At The Supplier s And Or Subcontractor Facility The Supplier Shall Notify Nswcpd Code 242Mo Two Weeks In Advance Prior To The Scheduled First Article Testing Inspection So An Nswcpd Representative Has The Option Of Being Present During The First Article Testing Inspection 4 9 First Article Approval For Testing Inspection Procedure And Acceptance Supplier Testing Inspection The Supplier Shall Prepare And Submit Their First Article Testing Inspection Procedure For Proximity Sensor Seated Switch In Accordance With The Requirements Of Di Ndti 80603 The Applicable Drawings Specifications Attachment A Electrical Test Procedure Navsea S9320 Am Pro 030 Mldg And S9320 Am Pro 020 Mldg And As Indicated On The Contract Data Requirements List Dd Form 1423 Government Approval Of The Procedure Is Required Prior To Commencement Of First Article Unit Cdrl First Article Testing Inspection Proc Per Di Ndti 80603A 4 10 First Article Testing Inspection Proximity Sensor Seated Switch The Supplier Shall Perform 100 Examination Inspection And Testing On The Completed First Article Unit Bulk Cable Component Parts Unit In Accordance With The Applicable Drawings Attachment A Electrical Test Procedure Navsea S9320 Am Pro 020 Mldg And S9320 Am Pro 030 Mldg And Their Approved First Article Procedure The Supplier Shall Record The Actual Measurements And Readings Of Each Examination Inspection And Test In Attachment A Electrical Test Procedure Navsea S9320 Am Pro 020 Mldg And S9320 Am Pro 030 Mldg And Each Dimension Identified On The Applicable Drawing 4 10 1 The Supplier Shall Visually Inspect And Perform Electrical Continuity And Dc Insulation Resistance Testing 100 On The Bulk Cable In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 10 2 The Supplier Shall Visually And Physically Inspect 100 The Switch And Connector Item Nos 4 And 5 Of Drawing 8590860 In Accordance With Navsea S9320 Am Pro 020 Mldg Requirements 4 10 3 The Supplier Shall Verify And Inspect 100 The Switch Item No 4 Of Drawing 8590860 Surface Has Been Prepared And Plasma Coated In Accordance With Navsea S9320 Am Pro 030 Mldg Requirements 4 10 4 The Supplier Shall Visually And Physically Inspect 100 The Completed Unit Of Each Dimension And Keyway Location Position Identified On Drawing 8590860 Including The Identification And Markings Required By Note 8 Of The Drawing 4 10 5 The Supplier Shall Visually Inspect 100 The Molded Switch And Plug Connector On The Completed Unit In Accordance With Navsea S9320 Am Pro 020 Mldg Requirements 4 10 6 The Supplier Shall Perform 100 Electrical Continuity Test On The Completed Unit In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 10 7 The Supplier Shall Perform 100 Insulation Resistance Test On The Completed Unit In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 10 8 The Supplier Shall Perform 100 Nondestructive Bonding Test On Molded Switch And Plug Connector On The Completed Unit In Accordance With Navsea S9320 Am Pro 020 Mldg Requirements 4 10 9 The Supplier Shall Perform 100 Hydrostatic Pressure Test On The Completed Unit In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 11 First Article Testing Inspection Reports And Acceptance Supplier Testing Inspection The Supplier Shall Submit For Completed First Article Unit Proximity Sensor Seated Switch Testing Inspection Reports In Compliance With The Requirements Of Di Ndti 80603 The Applicable Drawings Specifications Attachment A Electrical Test Procedure Navsea Manuals S9320 Am Pro 020 Mldg And S9320 Am Pro 030 Mldg The Report Shall Also Include A Copy Of Bulk Cable Inspection Test Report Type Dss 2 Per Mil Dtl 915 8 Certificate Of Conformance For Plasma Coating Polyurethane Molding Compound Back Fill And Primer Certificate Of Compliance For Switch Connector Nut O Ring And Polychloroprene Material Per Mil Dtl 915 Bulk Cable Inspection Test Report Per Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Identified In The Objective Quality Evidence Records Section Of This Document And As Indicated On The Contract Data Requirements List Dd Form 1423 Government Approval Of The First Article Testing Inspection Report Is Required Prior To Commencement Of Production Units Cdrl First Article Testing Inspection Report Per Di Ndti 80809B 4 12 Production Lot 4 13 Bulk Cable The Supplier Shall Perform 100 Examination Inspection And Testing On The Production Lot Bulk Cable Type Dss 2 In Accordance With The Applicable Requirements Listed In Specification Mil Dtl 915 8 Quality Conformance Inspection Basic Electrical Groups A B And C The Supplier Shall Record The Actual Measurements And Readings Results Of Each Examination Inspection And Test Specified In The Applicable Specification 4 14 Proximity Sensor Seated Switch The Supplier Shall Perform 100 Examination Inspection And Testing On Each Completed Production Lot Unit Bulk Cable Component Parts Unit In Accordance With The Applicable Drawings Attachment A Electrical Test Procedure Navsea S9320 Am Pro 020 Mldg And S9320 Am Pro 030 Mldg The Supplier Shall Record The Actual Measurements And Readings Of Each Examination Inspection And Test In Attachment A Electrical Test Procedure Navsea S9320 Am Pro 020 Mldg And S9320 Am Pro 030 Mldg And Each Dimension Identified On The Applicable Drawings 4 14 1 The Supplier Shall Visually Inspect And Perform Electrical Continuity And Dc Insulation Resistance Testing 100 On The Bulk Cable In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 14 2 The Supplier Shall Visually And Physically Inspect 100 Each Switch And Connector Item Nos 4 And 5 Of Drawing 8590860 In Accordance With Navsea S9320 Am Pro 020 Mldg Requirements 4 14 3 The Supplier Shall Verify And Inspect 100 Each Switch Item No 4 Of Drawing 8590860 Surface Has Been Prepared And Plasma Coated In Accordance With Navsea S9320 Am Pro 030 Mldg Requirements 4 14 4 The Supplier Shall Visually And Physically Inspect 100 Each Completed Unit Of Each Dimension And Keyway Location Position Identified On Drawing 8590860 Including The Identification And Markings Required By Note 8 Of The Drawing 4 14 5 The Supplier Shall Visually Inspect 100 The Molded Switch And Plug Connector On Each Completed Unit In Accordance With Navsea S9320 Am Pro 020 Mldg Requirements 4 14 6 The Supplier Shall Perform 100 Electrical Continuity Test On Each Completed Unit In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 14 7 The Supplier Shall Perform 100 Insulation Resistance Test On Each Completed Unit In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 14 8 The Supplier Shall Perform 100 Nondestructive Bonding Test On Molded Switch And Plug Connector On Each Completed Unit In Accordance With Navsea S9320 Am Pro 020 Mldg Requirements 4 14 9 The Supplier Shall Perform 100 Hydrostatic Pressure Test On Each Completed Unit In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Requirements 4 14 10 The Supplier Shall Conduct Pre Shipment Inspection And Verification Of Connector O Ring s Item No 8 Is Individually Packed And Shipped With Unit In Accordance With Note 2 Of Drawing 8590860 And Navsea S9320 Am Pro 020 Mldg 4 15 Production Lot Inspection Acceptance Supplier Testing Inspection The Supplier Shall Submit For The Production Lot Units The Inspection And Test Reports Identified In The Objective Quality Evidence Records Section Of This Document And As Indicated On The Contract Data Requirements List Dd Form 1423 Government Approval Is Required Prior To Shipment Of Production Units 4 16 Final Inspection And Acceptance Final Inspection And Acceptance Of Production Lots Shall Be Made By The Cognizant Dcma Qar Nswcpd Shall Either Issue Specific Government Inspection Instructions Or Inspection Hold Points Based On Whether Dcma Or Nswcpd Will Be Performing The Required Inspections Tests In Addition To The Normal Dcma Surveillance The Production Unit S Shall Be Under The Surveillance Of Nswcpd Quality Assurance Specialist As Required 4 17 Objective Quality Evidence Records The Supplier Shall Maintain Objective Quality Evidence Data Oqeds Of Materials Used In The Fabrication Of An Brr 6 Proximity Sensor Seated Switch Records Shall Be Traceable By Drawing Item Bulk Cable Master Reel Heat Lot Or Batch Serial And Contract Number All Oqeds Shall Be Clearly Legible Including Name And Title The Supplier May Provide Exact Quality Photocopies Of Objective Quality Evidence Records Being Delivered Under This Purchase Order Instead Of Originals 4 17 1 The Supplier Shall Furnish A Copy Of The Following Oqeds Listed Below And As Indicated On The Contract Data Requirements List Dd Form 1423 For Acceptance The Reports Shall Be Correlated To The Drawing Item Heat Lot Or Batch Contract And Assembly Serial Number Supplier Format Is Acceptable For The Below Listed Cdrls A The Supplier Shall Submit Production Lot Bulk Cable Type Dss 2 Examination Inspection And Test Reports In Accordance With The Applicable Requirements Listed In Specification Mil Dtl 915 8 Quality Conformance Inspection Basic Electrical Groups A B And C The Reports Shall Show All The Characteristics The Actual Measurement And Readings Of Each Examination Inspection And Testing Units Tested Including Contract Number Name Of Supplier Specification Number Date Bulk Cable Master Reel Manufacturer Part Test Start And Stop Times Gauge Serial Number Gauge Calibrated Date Due Date Of Finished Bulk Cable Item Nomenclature And Inspector s Acceptance Signature And Date Cdrl Producton Lot Bulk Cable Report Per Di Ndti 80809B B Certificate Of Conformance For 1 Plasma Coat Certifying Drawing 8590860 Item No 4 Has Been Plasma Coated Per Drawing And Navsea S9320 Am Pro 030 Mldg Requirements 2 Polyurethane Molding Compound Material Type Ii Color Amber Certifying Material Type And Color Has Not Exceeded The Shelf Life Recommended By The Manufacturer As Required By Mil M 24041 3 Back Fill Material And Primer Per Navsea S9320 Am Pro 020 Mldg Certifying Material And Type Has Not Exceeded The Shelf Life Recommended By The Manufacturer Cdrl Certificate Of Conformance Per Di Misc 80678 C Certificate Of Compliance For 1 Switch Certifying Item No 4 To Drawing 8590860 And The Applicable Manufacture Part Number Requirements 2 Connector Certifying Item No 5 To Drawing 8590860 And The Manufacture Part Number Xsj 2 Ccr Requirements 3 Nut Certifying Item No 7 To Drawing 8590860 And The Applicable Manufacture Part Number Requirements 4 O Ring Certifying Item No 8 To Drawing 8590860 And The Manufacture Part Number 5 058 N674 70 Requirements 5 Polychloroprene Material Certifying Material To Drawing 8590854 And Mil Dtl 915 Requirements Cdrl Certificate Of Compliance Per Di Misc 80678 D The Supplier Shall Submit Production Lot Bulk Cable For Drawing 8590860 Item No 3 Type Dss 2 Examination Inspection And Test Reports Consisting Of Visual Inspection Electrical Continuity Test And Dc Insulation Resistance Test In Accordance With Attachment A Electrical Test Procedure And Navsea Manual S9320 Am Pro 020 Mldg Appendix Ii D Data Sheets Ds1 Ds2 And Ds3 The Reports Shall Also Include The Contract Number Name Of Supplier Drawing Item Number Drawing Revision Letter Specification Number Date Bulk Cable Master Reel Item Nomenclature And Inspector s Acceptance Signature And Date Cdrl Producton Lot Bulk Cable Report Per Di Ndti 80809B E The Supplier Shall Submit Production Lot Proximity Sensor Seated Switch Examnation Inspection And Testing Reports Consisting Of Visual Inspection Of Molded Connectors Electrical Continuity Test Insulation Resistance Test Nondestructive And Destructive Bonding Test On Molded Connectors Hydrostatic Pressure Test And Pre Shipment Inspection Verification Item No 8 Of Drawing 8590860 In Accordance With Attachment A Electrical Test Procedure And Navsea Manual S9320 Am Pro 020 Mldg Appendix Ii D Data Sheets Ds4 Thru Ds8 Ds9 The Reports Shall Also Include Cable Assembly Dimensional Inspection Drawing 8590860 Contract Number Name Of Supplier Drawing Item Number Drawing Revision Letter Cable Assembly Serial Item Nomenclature And Inspector s Acceptance Signature And Date Cdrl Producton Lot Cable Assembly Report Per Di Ndti 80809B F Mercury Exclusion Certification Representing The Contract Units Shipment Cdrl Mercury Exclusion Certification Per Di Misc 80678 5 Packaging 5 1 Preservation Packaging Packing And Marking Preservation Packaging Packing And Marking Shall Be In Accordance With The Contract Purchase Order Schedule And As Specified Below Mil Std 2073 Packaging Applies As Found Elsewhere In The Schedule 6 Notes 6 1 Ordering Information For Document References The Department Of Defense Single Stock Point Dodssp Website Http Www Dsp Dla Mil Provides Product Information For The Department Of Defense Index Of Specifications And Standards Dodiss I E Military Federal Specifications And Standards Data Item S Dids And Other Dodssp Products A Availability Of Cancelled Documents The Dodssp Offers Cancelled Documents That Are Required By Private Industry In Fulfillment Of Contractual Obligations In Paper Format Documents Can Be Requested By Phoning The Subscription Services Desk B Commercial Specifications Standards And S These Specifications Standards And Descriptions Are Not Available From Government Sources They May Be Obtained From The Publishers Of The Applicable Societies C Ordnance Standards Os Weapons Specifications Ws And Navord Ostd 600 Pages These Type Publications May Be Obtained By Submitting A Request To Commander Indian Head Division Naval Surface Warfare Center Code 8410P 101 Strauss Avenue Indian Head Md 20640 5035 D On Post Award Actions Requests For Official Use Only And Noforn Not Releasable To Foreign Nationals Documents Must Identify The Government Contract Number And Must Be Submitted Via The Cognizant Defense Contract Management Command Dcmc For Certification Of Need For The Document On Pre Award Actions Such Requests Must Be Submitted To The Pco For Certification Of Need For The Document E Noforn Military Specifications And Standards Including Amendments Change Notices And Supplements But Not Interim Changes To Be Ordered From Contracting Officer Navicp Mech Code 87321 5450 Carlisle Pike P O Box 2020 Mechanicsburg Pa 17055 0788 F Nuclear Reactor Publications Assigned Navsea Documents And Identification Numbers I E Navsea Welding Standard Navsea 250 1500 1 Are To Be Ordered From Commanding Officer Navicp Mech Code 009 5450 Carlisle Pike P O Box 2020 Mechanicsburg Pa 17055 0788 G Technical Manuals Assigned Navsea Identification Numbers I E Navsea Welding And Brazing Procedure Navsea S9074 Aq Gib 010 248 Are To Be Ordered From Naval Inventory Control Point Code 1 Support Branch 700 Robbins Avenue Phildelphia Pa 19111 5094 H Interim Changes And Classified Specifications Shall Be Obtained By Submitting A Request On Dd Form 1425 To Navicp Mech Date Of First Submission Asreq Approval Of The Quality Inspection Plan By Nswc Philadelphia Division Is Required Prior To First Article Nswcpd Is The Acceptance Activity For Cdrl Data Item A001 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Approval Of The Procedure By Nswc Philadelphia Division Is Required Prior To Commencement Of First Article Unit Nswcpd Is The Acceptance Activity For Cdrl Data Item A002 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Approval Of The Report By Nswc Philadelphia Division Is Required Prior To Commencement Of Production Lot Units Nswcpd Is The Acceptance Activity For Cdrl Data Item A003 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Supplier Format Is Acceptable Report Shall Be In Accordance With Drawing 8590860 Item No 3 And Mil Dtl 915 8 Approval Of The Report By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units Nswcpd Is The Acceptance Activity For Cdrl Data Item A004 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Supplier Format Is Acceptable Certificate Of Conformance Various Items See Contract Section E For 1 Plasma Coating 2 Polyurethane Molding Compound 3 Back Fill Amp Primer Approval Of The Certification By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units Nswcpd Is The Acceptance Activity For Cdrl Data Item A005 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Supplier Format Is Acceptable Certificate Of Compliance For Drawing 8590860 Item Nos 4 5 7 And 8 Drawing 8590854 Polychloroprene Material Approval Of The Certification By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units Nswcpd Is The Acceptance Activity For Cdrl Data Item A006 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Report Shall Be In Accordance With Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Approval Of The Report By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units Nswcpd Is The Acceptance Activity For Cdrl Data Item A007 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Report Shall Be In Accordance With Drawing 8590860 Attachment A Electrical Test Procedure And Navsea S9320 Am Pro 020 Mldg Approval Of The Report By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units Nswcpd Is The Acceptance Activity For Cdrl Data Item A008 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498 Date Of First Submission Asreq Supplier Format Is Acceptable Approval Of The Certification By Nswc Philadelphia Division Is Required Prior To Shipment Of Production Lot Units Nswcpd Is The Acceptance Activity For Cdrl Data Item A009 Nswcpd Wawf Irapt Acceptor Dodacc Is N64498
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 37499094
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.