Tenders Are Invited For Upgradation Work Replacement Of Existing 385Kvar Supply Installation Testing And Com ...
Tender Notice
TenderID
36018807
Tender Brief
Tenders Are Invited For Upgradation Work Replacement Of Existing 385Kvar Supply Installation Testing And Commissioning Of 400Kvar C Apacitor Bank Emirates Pumping Station
Quotation Are Invited For Upgradation Work Replacement Of Existing 385Kvar Supply Installation Testing And Commissioning Of 400Kvar C Apacitor Bank Emirates Pumping Station Boq Scope Of Work Upgradation Work Replacement Of Existing 385Kvar Supply Installation Testing And Commissioning Of 400Kvar C Apacitor Bank Emirates Pumping Station Qty 2 Lots Shall Comply And Include The Following 1 10 Steps Programming Steps Minimum Utilizing 5Kvar As Smallest Capacity To Correct Power Factor Of Small And Auxiliary Loads When Pumping Station Is In Standby Mode Wi Th No Pump Running 2 Design Calculations And Sizing Shall Be As Per Dewa Regulations And Iec Standards All Shall Be Submitted An D Approved By Dewa 3 Use Of Full Fixed Contact Holders Unclipped Busbar Force Fitting Of Contacts Not Allowed 4 Capbank Compart Ment Fire Smoke Detectors With Warning Light Annunciator And I O Feedback 5 Unstable Compensation Detection Pf Set Not Reached Monitor Capacitor Failure Detector Including Each Capacitor Reactor Temperature Detection And Feedback 6 Separate Compartment Of Controls Vs Capacitors 7 Forced Ventilation Fan Cooling Shall Be Redundant 8 Multifunction Controller From Reputable Brand With Mo Dbus Communication Protocol As Minimum 9 Panel Materials Capacitors Detuned Reactors Shall Be From Reputable Manufacturer Equiva Lent To Schneider Heavy Duty Capacitors High Performance Long Life With Oem Detuned Reactors Etc 10 Capacitor Safety Includes Se Lf Healing Pressure Sensitive Disconnector Discharge Device 11 Minimum Clearances For Better Air Circulation A Minimum Cleara Nce Of 30Mm Between Capacitor Units And Panel Enclosure Need To Be Kept Also Maintain 30Mm Gap Above The Top Of The Capacitor 12 Detuned Reactors Shall Include Temperature Detectors 13 It Is Mandatory To Use Mccb Or Mcb For The Individual Step Against Over Cur Rent And Short Circuit Protection In Series With Fuses For All Steps 14 Safety Visible Labels Shall Include Hazard Of Electrical S Hock Wait 5 Minutes After Isolating Supply Before Handling Failure To Follow These Instructions Can Result In Injury Or Equipment Da Mage In Designated Location Of Panel 15 Safety Shroud Protection When Doors Are Opened 16 All Components And Materials Shall Be Ab Le To Operate In 55Deg C Ambient Temperature 17 400Kvar Is Minimum However Pfc Kvar Design Shall Be Per Actual Load In The Station 18 Comply To Pfc Bank Design Consideration Discharge Time Clause 22 Iec 60831 75V In 3 Minutes Temperature Clause 4 1 Iec 60831 Class D 55 C Ambient Temperature De Rating Ventilation Requirement Overvoltage Condition Clause 5 3 5 Iec 61921 Resonance Condition Over Load Clause 5 3 7 Iec 61921 Continuous Current 1 3 Times Ip Clause 5 3 8 Iec 61921 Ip 20 For Ind Oor Application Physical Location Of Components And Accessibility Clause 5 3 9 Iec 61921 Protection Alarms Clause 5 5 3 5 5 4 Iec 61921 Fire Hazard Applicable Standards Iec 61921 Power Capacitorslow Voltage Power Factor Correction Banks Is T He International Standard Applicable For Low Voltage Power Factor Correction Banks And Automatic Power Factor Correction Apfc Equi Pment Intended To Be Used For Power Factor Correction Purposes Equipped With Built In Switch Gears And Control Gears The Guideline S For Design Installation Operation And Safety Of Apfc Panels Are Followed Based On This International Standard Iec 60831 Part 1 2 Shunt Power Capacitors Of The Self Healing Type For A C Systems Having Rated Voltage Up To And Including 1Kv Iec 61439 1 Low Voltage Switchgear And Control Gear Assemblies Particular Requirements For Low Voltage Switchgear And Control Gear Assemblies I Ntended To Be Installed In Places Where Unskilled Persons Have Access For Their Use Distribution Boards Iec 60947 Low Voltage Sw Itchgear Part 2 Molded Case Circuit Breakers Air Circuit Breakers Part 4 Power Contactors Part 4 3 Thyristor Switch Iec 60076 6 Reactors Iec 60529 Degree Of Protection Provided By Enclosure Ip Code Iec 60664 1 Iec 61326 Power Factor Controller Iec 62208 Empty Enclosures For Low Voltage Switchgear And Controlgear Assemblies General Requirements For Technical Queries Please Contact Leonito De Los Santos 0527038780 Email Leonito Santos Dewa Gov Ae Qty 2Standard Terms Conditions1 Prices Should Be Ddp Delivery Duty Paid At Dewa Stores 2 Quotation To Be Submitted Only In Local Currency U A E Dirhams3 Dewa Standard Payment Terms Is 30 Days Credit From The Date Of Acceptance Of Material4 No Dewa Staff Or His Or Her Relatives Up To Third Degree Should Have Ownership Or Partnership In Your Company And Your Participation In Dewa Tenders Rfqs Should Not Constitute A Conflict Or Perceived Conflict Of Interest
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 36018807
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.