Contract Notice Thermal Insulation WorkGgs Zastrowstr Technical InsulationDescription Insulation On Drainage Pipesall Drainage Pipes Are Installed As Sml Pipes Sewer Pipes With Ventilation Connections In The Roof Area And Partly In Walls In Hazardous Areas Are Insulated With Aluminum Coated Mineral Fiber Mats Internal Rainwater Drainage Pipes Also Receive Insulation From Aluminum Coated Mineral Fiber Mats In The Floors Below The Drainage Level Insulation On Drinking Water Pipes All Cold And Hot Water Pipes Are Insulated With Self Adhesive Insulating Shells With Tear Resistant Aluminum Foil Building Material Class A2 Cold Water Pipes Are Insulated With The Insulation Thickness Provided For In Din 1988 The Special Care Of The Diffusion Tightness When Laying The Insulation Is Expressly Pointed Out Hot And Circulating Pipes Are Insulated With The Insulation Thickness Provided For In The Energy Saving Ordinance All Fittings Are Supplied With Insulating Caps Made Of Sheet Steel With Clamping Lever Closures And Steel Straps Insulation On Heating Pipes All Heating Pipes Are Laid In Steel Pipe And Carbon Steel Pipe The Thermal Insulation Of The Pipes Should Be Made With Self Adhesive Aluminum Laminated Mineral Wool Shells Non Flammable Greater Than 1000Oc Done In Suspended Ceilings And Shafts The Thickness Of The Thermal Insulation Is To Be Carried Out According To Enev In The Technical Centers Up To A Mounting Height Of 3 5 M And In Areas Prone To Impact Receives The Previously Describedinsulation Additionally A Hot Dip Galvanized Sheet Steel Jacket All Fittings Receive The Same Insulation From Insulating Caps With Lever Locks And Hinges Visible Pipes In The Air Handling Units And In The Central Heating System Are Provided With Mineral Wool Insulating Shells And Additional Hot Dip Galvanized Sheet Steel Casing All Fittings With Insulation Caps Insulation Thickness 100 According To Enev Made Of Galvanized Sheet Steel With Lever Locks On Hinges To Open The Cap Insulation On Air Ducts Air Ducts In The Building In Suspended Ceilings Shafts And In The Technical Centers At Altitudes Above 2 0 M Are Insulated With Aluminum Clad Mineral Fiber Boards Of Building Material Class A1 The Insulation Thickness Is Always 30 Mm Time Limit For Receipt Of Tenders Or Requests To Participate Date 25 06 2019 Local Time 10 00 Disclaimer The Above Text Is Machine Translated For Accurate Information Kindly Refer The Original Document
Contact Information
Other Detail
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 20350748
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.