Bids Are invited for Design, Supply, Installation, Testing And Commissioning Of Air Conditioning Plant - Top Discharge Vrf Outdoor Condensing Units (Air-Cooled) Of Actual Capacity Min. 36Hp (Min. 28.5 Tr) Designed To Ambient Conditions (Tuticorin) Along With Its Group Controller, Ahu Expansion Kit And Refnet Joint As Required And Recommended By Vrf Oem. , Armoured Shielded Copper Cable For Control And Communication In Between Outdoor, Indoor And Group Controller Units Etc.. , Refrigerant Copper Piping With Nitrile Rubber Insulation And The Same To Be Laid Through Perforated Gi Tray 500Mm (W) X 100Mm (H) With Cover.Note: Each Rmt Includes Length Of Suction Line, Liquid Line, Insulation And Gi Tray , Electrical Works Including Tapping Of Incoming Power From The Electrical Panel Kept In The Ahu Room With Necessary Cable Trays And All Other Accessories As Required To Commission The Vrf System. , Air Handling Unit (Once Through/100% Fresh Air Type) At Sslv Assembly Facility , Air Handling Unit (Once Through/100% Fresh Air Type) At Launch Pad , 50 Mm Cpvc Pipes For Condensate Water , Heating Kit 9 Kw (Thermostat 3Kw, Humidistat 3Kw & Manual Banks 3Kw) With Its Necessary Cabling. , Site / Pre – Fabricated 0.8Mm Thick Gss Ducting Along With30 Mm Thick Phenolic Foam Insulation And Necessary Supporting Arrangement For Checkout Room. , Aluminum Grills With Vcd. , Fresh Air Intake Louvers. , Fusible Link Type Fire Dampers In Supply Air Duct /Path. , Fresh Air Intake Louvers With Vcd At Mls Room Air Exhaust. , Pre - Fabricated 3 Mm Thick, Dia. Of 450 Mm Circular Aluminum Duct, With Min. 50Mm Thick Phenolic Foam Insulation, Vapour Barrier, Gi Wire Mesh, 24-Gauge Al Cladding Etc. With Necessary Supporting Arrangement , 3 Mm Thick Aluminium Sheet For Making Box And Mls Outside Ducting With 50 Mm Thick Phenolic Foam Insulation On All Side With Necessary Supporting Arrangement. , Ss 304L/316/304 Braided Flexible Bellow Of 450Mm Diameter With 0.5M Length. , Duct Temperature Sensor Cum Transmitter (4-20Ma) Type , Armoured Shielded 1.5 Sqm. Copper Communication/Power Cable For Above Duct Temperature Sensor Up To Ddc Panel. , Room Temperature And Rh Sensor Cum Transmitter Of 4-20Ma Type , Armoured Shielded 1.5Sqm. Copper Communication/Power Cable For Above Room Temperature And Rh Sensor Up To Ddc Panel With Plug In And Plug Out Arrangement.. , Ambient Temperature And Rh Sensor Cum Transmitter Of 4-20Ma Type , Armoured Shielded 1.5Sqm. Copper Communication/Power Cable For Above Ambient Temperature And Rh Sensor Up To Ddc Panel. , Electrical Works Including Supply Of Electrical Panel, All The Power And Control Cables Along With Necessary Cable Trays And All Other Accessories As Required To Commission The Complete System Including Tfa And Vrf System. This Panel Shall Be Placed In The Ahu Room.Note: Distance Between Electrical Main Panel To Ahu Panel Is Approximately 30 M At Saf And 30M At Lp (Tentative Xlpe Al Cable Size: 120Sqmm X 4C X 1R) , 300Mm (W) X 100Mm (H) Perforated Cable Tray With Cover.
|