|
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Onboard 1241 Re And B Class Of Ships At Naval Dockyard Mumbai; 2 Yrs Rc Repair/Refurbishment Stw Of Da/Ta Ctrl Sys And Flame Ind On Re And B Class; Service Provider - First Year Service – Da Control Panel For Re/Pe Class – Removal Of Connections From Panels & Associated Systems And Securing Of All Removed Connections , First Year Service – Da Control Panel For Re/Pe Class – Removal Of Connections At All Sensors, Solenoids And Switches End And Securing Of End Connections , First Year Service – Da Control Panel For Re/Pe Class – Degutting & Removal Of Panel & Associated System , First Year Service – Da Control Panel For Re/Pe Class – Transport Of The Panel To Oem Premises In Pune And Back To Mumbai , First Year Service – Da Control Panel For Re/Pe Class – Visual Inspection Of Panels And Repair, Renew / Refurbish As Required , First Year Service – Da Control Panel For Re/Pe Class – Survey Of Internal Connectors On Panel And Replace As Required , First Year Service – Da Control Panel For Re/Pe Class – Cleaning Of All Components Including Pcbs. , First Year Service – Da Control Panel For Re/Pe Class – Renewal /Repair/ Replacement Of Defective Pcbs & Components As Required & Tuning With System , First Year Service – Da Control Panel For Re/Pe Class – Renewal Of Internal Panel Wiring As Required , First Year Service – Da Control Panel For Re/Pe Class – Calibration Of Panels , First Year Service – Da Control Panel For Re/Pe Class – Porting Of Latest Version Of Application Software Wherever Required. , First Year Service – Da Control Panel For Re/Pe Class – Assemble The System After Maintenance And Carry Out Complete Functional Checks In Simulation. , First Year Service – Da Control Panel For Re/Pe Class – Undertake Conductivity Checks, Insulation Checks Of Cables (External). The Cable Wise Report Will Be Submitted To Meci. , First Year Service – Da Control Panel For Re/Pe Class – Remove Defective Control System Cables After Degutting And Mark Layouts (However, Where It Is Not Possible To Remove The Cable, The Cable Will Be Either Isolated And Secured At The Same Place Or Tried To Be Chopped Off From Feasible Locations So As To Avoid Addition Of Extra Load). The Removal Or Replacement Of Cable Will Be Carried Out Post Clearance From Authorised Meci Rep. , First Year Service – Da Control Panel For Re/Pe Class – Examine Cable Trays And Cable Hangers Related To Control Cables And Replace Damaged Trays And Cable Hangers As Indicated By Authorised Meci Reps. , First Year Service – Da Control Panel For Re/Pe Class – Relaying New Control Cables And Terminate/Connectorized As Required In Consultation With Authorised Meci Reps. , First Year Service – Da Control Panel For Re/Pe Class – Renewal / Replacement Of Sensors And Switches With New Ones As Required. The Required Spares Will Be Provided By Ss Or Eci Dept. , First Year Service – Da Control Panel For Re/Pe Class – Undertake Conductivity Checks, Insulation Checks Post Relaying Of Cables. The Cable Wise Report Will Be Submitted To Meci. , First Year Service – Da Control Panel For Re/Pe Class – Fitment Of Panels & Associated Systems. , First Year Service – Da Control Panel For Re/Pe Class – Complete Connectorisation To Integrate System , First Year Service – Da Control Panel For Re/Pe Class – Cold Checks On The Panel , First Year Service – Da Control Panel For Re/Pe Class – Cold Checks On The Panel Including All Sensors And Its Measuring Point Checks , First Year Service – Da Control Panel For Re/Pe Class – Hot Checks On The Panel , First Year Service – Da Control Panel For Re/Pe Class – Hot Checks On The Panel Including All Sensors And Its Measuring Point Checks , First Year Service – Da Control Panel For Re/Pe Class – Offer Inhouse Sdc Of System , First Year Service – Da Control Panel For Re/Pe Class – Witnessing Of In-House Trials. , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Indicating Facia With Back Lit Windows , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Dc / Dc Convertor Module , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Rpm Sensing Pcb , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Temperature Indicator Pcb (Cr / Al) , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Temperature Controller & Indicator Pcb (Pt100) , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Pressure Controller & Indicator Pcb , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Flasher / Timer Pcb , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Rtd Probe , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Thermocouple Probe , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Pressure Transmitters In M.S. Enclosure , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Magnetic Pick Up , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment Of Contactor , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of 63 Mm Bourdon Pressure Gauge Glycerin Filled , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Ana. Press. Gauge With Meter Dial , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Hour Counter , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Voltmeter , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Ammeter , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Transformer , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment & Calibration Of Voltage Controlled Rectifier. , First Year Service – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment Of Maintenance Free Batteries , Second Year Service – Da Control Panel For B Class– Removal Of Connections From Panels & Associated Systems And Securing Of All Removed Connections , Second Year Service – Da Control Panel For B Class– Removal Of Connections At All Sensors, Solenoids And Switches End And Securing Of End Connections , Second Year Service – Da Control Panel For B Class– Degutting & Removal Of Panel & Associated System , Second Year Service – Da Control Panel For B Class– Transport Of The Panel To Oem Premises In Pune And Back To Mumbai , Second Year Service – Da Control Panel For B Class– Visual Inspection Of Panels And Repair, Renew / Refurbish As Required , Second Year Service – Da Control Panel For B Class– Survey Of Internal Connectors On Panel And Replace As Required , Second Year Service – Da Control Panel For B Class– Cleaning Of All Components Including Pcbs. , Second Year Service – Da Control Panel For B Class– Renewal /Repair/ Replacement Of Defective Pcbs & Components As Required & Tuning With System , Second Year Service – Da Control Panel For B Class– Renewal Of Internal Panel Wiring As Required , Second Year Service – Da Control Panel For B Class– Calibration Checks On Panel Including Pcbs By Simulation If Input Signals , Second Year Service – Da Control Panel For B Class– Calibration Checks Of All Inputs And Output Meters With Renewal Of All Defective Meters , Second Year Service – Da Control Panel For B Class– Porting Of Latest Version Of Application Software Wherever Required. , Second Year Service – Da Control Panel For B Class– Assemble The System After Maintenance And Carry Out Complete Functional Checks In Simulation. , Second Year Service – Da Control Panel For B Class– Undertake Conductivity Checks, Insulation Checks Of Cables (External). The Cable Wise Report Will Be Submitted To Meci. , Second Year Service – Da Control Panel For B Class– Remove Defective Control System Cables After Degutting And Mark Layouts (However, Where It Is Not Possible To Remove The Cable, The Cable Will Be Either Isolated And Secured At The Same Place Or Tried To Be Chopped Off From Feasible Locations So As To Avoid Addition Of Extra Load). The Removal Or Replacement Of Cable Will Be Carried Out Post Clearance From Authorised Meci Rep. , Second Year Service – Da Control Panel For B Class– Examine Cable Trays And Cable Hangers Related To Control Cables And Replace Damaged Trays And Cable Hangers As Indicated By Authorised Meci Reps. , Second Year Service – Da Control Panel For B Class– Relaying New Control Cables And Terminate/Connectorized As Required In Consultation With Authorised Meci Reps. , Second Year Service – Da Control Panel For B Class– Renewal / Replacement Of Sensors And Switches With New Ones As Required. The Required Spares Will Be Provided By Ss Or Eci Dept. , Second Year Service – Da Control Panel For B Class– Undertake Conductivity Checks, Insulation Checks Post Relaying Of Cables. The Cable Wise Report Will Be Submitted To Meci. , Second Year Service – Da Control Panel For B Class– Fitment Of Panels & Associated Systems. , Second Year Service – Da Control Panel For B Class– Complete Connectorisation To Integrate System , Second Year Service – Da Control Panel For B Class– Cold Checks On The Panel Including All Sensors And Its Measuring Point Checks , Second Year Service – Da Control Panel For B Class– Hot Checks On The Panel Including All Sensors And Its Measuring Point Checks , Second Year Service – Da Control Panel For B Class– Offer Inhouse Sdc Of System , Second Year Service – Da Control Panel For B Class– Witnessing Of In-House Trials , Second Year Service – Da Control Panel For B Class– Removal Of Connections From Panels & Associated Systems And Securing Of All Removed Connections , Second Year Service – Ta Control Panel For B Class– Removal Of Connections At All Sensors, Solenoids And Switches End And Securing Of End Connections , Second Year Service – Ta Control Panel For B Class– Degutting & Removal Of Panel & Associated System , Second Year Service – Ta Control Panel For B Class– Transport Of The Panel To Oem Premises In Pune And Back To Mumbai , Second Year Service – Ta Control Panel For B Class– Visual Inspection Of Panels And Repair, Renew / Refurbish As Required , Second Year Service – Ta Control Panel For B Class– Survey Of Internal Connectors On Panel And Replace As Required , Second Year Service – Ta Control Panel For B Class– Cleaning Of All Components Including Pcbs. , Second Year Service – Ta Control Panel For B Class– Renewal /Repair/ Replacement Of Defective Pcbs & Components As Required & Tuning With System , Second Year Service – Ta Control Panel For B Class– Renewal Of Internal Panel Wiring As Required , Second Year Service – Ta Control Panel For B Class– Calibration Checks On Panel Including Pcbs By Simulation If Input Signals , Second Year Service – Ta Control Panel For B Class– Calibration Checks Of All Inputs And Output Meters With Renewal Of All Defective Meters , Second Year Service – Ta Control Panel For B Class– Porting Of Latest Version Of Application Software Wherever Required. , Second Year Service – Ta Control Panel For B Class– Assemble The System After Maintenance And Carry Out Complete Functional Checks In Simulation. , Second Year Service – Ta Control Panel For B Class– Undertake Conductivity Checks, Insulation Checks Of Cables (External). The Cable Wise Report Will Be Submitted To Meci. , Second Year Service – Ta Control Panel For B Class– Remove Defective Control System Cables After Degutting And Mark Layouts (However, Where It Is Not Possible To Remove The Cable, The Cable Will Be Either Isolated And Secured At The Same Place Or Tried To Be Chopped Off From Feasible Locations So As To Avoid Addition Of Extra Load). The Removal Or Replacement Of Cable Will Be Carried Out Post Clearance From Authorised Meci Rep. , Second Year Service – Ta Control Panel For B Class– Examine Cable Trays And Cable Hangers Related To Control Cables And Replace Damaged Trays And Cable Hangers As Indicated By Authorised Meci Reps. , Second Year Service – Ta Control Panel For B Class– Relaying New Control Cables And Terminate/Connectorise As Required In Consultation With Authorised Meci Reps. , Second Year Service – Ta Control Panel For B Class– Renewal / Replacement Of Sensors And Switches With New Ones As Required. The Required Spares Will Be Provided By Ss Or Eci Dept. , Second Year Service – Ta Control Panel For B Class– Undertake Conductivity Checks, Insulation Checks Post Relaying Of Cables. The Cable Wise Report Will Be Submitted To Meci. , Second Year Service – Ta Control Panel For B Class– Fitment Of Panels & Associated Systems. , Second Year Service – Ta Control Panel For B Class– Complete Connectorisation To Integrate System , Second Year Service – Ta Control Panel For B Class– Cold Checks On The Panel Including All Sensors And Its Measuring Point Checks , Second Year Service – Ta Control Panel For B Class– Hot Checks On The Panel Including All Sensors And Its Measuring Point Checks , Second Year Service – Ta Control Panel For B Class– Offer Inhouse Sdc Of System , Second Year Service – Ta Control Panel For B Class– Witnessing Of In-House Trials , Second Year Service – Flame In-Out Relay For B Class– Carrying Out Maintenance Routine And Setting To Work For The Flame In-Out System , Second Year Service – Da Control Panel For Re/Pe Class – Removal Of Connections From Panels & Associated Systems And Securing Of All Removed Connections , Second Year Service – Da Control Panel For Re/Pe Class – Removal Of Connections At All Sensors, Solenoids And Switches End And Securing Of End Connections , Second Year Service – Da Control Panel For Re/Pe Class – Degutting & Removal Of Panel & Associated System , Second Year Service – Da Control Panel For Re/Pe Class – Transport Of The Panel To Oem Premises In Pune And Back To Mumbai , Second Year Service – Da Control Panel For Re/Pe Class – Visual Inspection Of Panels And Repair, Renew / Refurbish As Required , Second Year Service – Da Control Panel For Re/Pe Class – Survey Of Internal Connectors On Panel And Replace As Required , Second Year Service – Da Control Panel For Re/Pe Class – Cleaning Of All Components Including Pcbs. , Second Year Service – Da Control Panel For Re/Pe Class – Renewal /Repair/ Replacement Of Defective Pcbs & Components As Required & Tuning With System , Second Year Service – Da Control Panel For Re/Pe Class – Renewal Of Internal Panel Wiring As Required , Second Year Service – Da Control Panel For Re/Pe Class – Calibration Of Panels , Second Year Service – Da Control Panel For Re/Pe Class – Porting Of Latest Version Of Application Software Wherever Required. , Second Year Service – Da Control Panel For Re/Pe Class – Assemble The System After Maintenance And Carry Out Complete Functional Checks In Simulation. , Second Year Service – Da Control Panel For Re/Pe Class – Undertake Conductivity Checks, Insulation Checks Of Cables (External). The Cable Wise Report Will Be Submitted To Meci. , Second Year Service – Da Control Panel For Re/Pe Class – Remove Defective Control System Cables After Degutting And Mark Layouts (However, Where It Is Not Possible To Remove The Cable, The Cable Will Be Either Isolated And Secured At The Same Place Or Tried To Be Chopped Off From Feasible Locations So As To Avoid Addition Of Extra Load). The Removal Or Replacement Of Cable Will Be Carried Out Post Clearance From Authorised Meci Rep. , Second Year Service – Da Control Panel For Re/Pe Class – Examine Cable Trays And Cable Hangers Related To Control Cables And Replace Damaged Trays And Cable Hangers As Indicated By Authorised Meci Reps. , Second Year Service – Da Control Panel For Re/Pe Class – Relaying New Control Cables And Terminate/Connectorise As Required In Consultation With Authorised Meci Reps , Second Year Service – Da Control Panel For Re/Pe Class – Renewal / Replacement Of Sensors And Switches With New Ones As Required. The Required Spares Will Be Provided By Ss Or Eci Dept , Second Year Service – Da Control Panel For Re/Pe Class – Undertake Conductivity Checks, Insulation Checks Post Relaying Of Cables Of All 03 Das . The Cable Wise Report Will Be Submitted To Meci , Second Year Service – Da Control Panel For Re/Pe Class – Fitment Of Panels & Associated Systems , Second Year Service – Da Control Panel For Re/Pe Class – Complete Connectorisation To Integrate System , Second Year Service – Da Control Panel For Re/Pe Class – Cold Checks On The Panel , Second Year Service – Da Control Panel For Re/Pe Class – Cold Checks On The Panel Including All Sensors And Its Measuring Point Checks , Second Year Service – Da Control Panel For Re/Pe Class – Hot Checks On The Panel , Second Year Service – Da Control Panel For Re/Pe Class – Hot Checks On The Panel Including All Sensors And Its Measuring Point Checks , Second Year Service – Da Control Panel For Re/Pe Class – Offer Inhouse Sdc Of System , Second Year Service – Da Control Panel For Re/Pe Class – Witnessing Of In-House Trials , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of Analogue Gauge With Dial , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Hmi Screen, 10 Inch , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Hour Counter , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment Of, Hooter, 24V Dc , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment Of Rotary Switch, 3-Pole On/Off , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Logic Control Module , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Inst. Power Supply , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment Of Switch Mode Power Supply , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment, Mcb, 2-Pole/6A , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment Of Battery , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Signal Conditioning Module For Rtd , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Signal Conditioning Module For Thermocouple , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Signal Conditioning Module For Rpm , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Signal Conditioning Module For Fuel Rack , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Signal Conditioning Module For Pressure , Second Year Services – Da Control Panel For B Class – Repair/ Refurbishment & Calibration Of, Terminal Pcb , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment Of Tft Screen , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment Of Two Position Switch , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment, Calibration Of Main Processor , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment, Calibration Of Inst. Power Supply , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment, Calibration Of Smps , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment Of Maintenance Free Batteries , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment, Calibration Of Rtd Probes , Second Year Services – Ta Control Panel For B Class – Repair/ Refurbishment, Calibration Of Press. Transmitter , Second Year Services – Ta Control Panel For B Class –Repair/ Refurbishment, Calibration Of Signal Cond. Module , Second Year Service – Flame In-Out Relay For B Class– Repair/ Refurbishment, Calibration Of Sensitivity Control Unit , Second Year Service – Flame In-Out Relay For B Class– Repair/ Refurbishment, Calibration Of Transformer , Second Year Service – Flame In-Out Relay For B Class– Repair/ Refurbishment, Calibration Of Flame Sensor Pcb , Second Year Service – Flame In-Out Relay For B Class– Repair/ Refurbishment, Calibration Of Flame Sensor , Second Year Services – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment, Calibration Of Indicating Facia With Back Lit Windows , Second Year Services – Da Control Panel For 1241 Re/Pe Class– Repair/ Refurbishment, Calibration Of Dc / Dc Convertor Module , Second Year Services – Da Control Panel For 1241 Re/Pe Class– Repair/ Refurbishment, Calibration Of Rpm Sensing Pcb , Second Year Services – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment, Calibration Of Temperature Indicator Pcb (Cr / Al) , Second Year Services – Da Control Panel For 1241 Re/Pe Class –Repair/ Refurbishment, Calibration Of Temperature Controller & Indicator Pcb (Pt100) , Second Year Services– Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment, Calibration Of Pressure Controller & Indicator Pcb , Second Year Services – Da Control Panel For 1241 Re/Pe Class –Repair/ Refurbishment, Calibration Of Flasher / Timer Pcb , Second Year Services – Da Control Panel For 1241 Re/Pe Class– Repair/ Refurbishment, Calibration Of Rtd Probe , Second Year Services – Da Control Panel For 1241 Re/Pe Class –Repair/ Refurbishment, Calibration Of Thermocouple Probe , Second Year Services – Da Control Panel For 1241 Re/Pe Class –Repair/ Refurbishment, Calibration Of Pressure Transmitters In M.S. Enclosure , Second Year Services – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment, Calibration Of Magnetic Pick Up , Second Year Services – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment Of Contactor , Second Year Services – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment, Calibration Of 63 Mm Bourdon Pressure Gauge Glycerin Filled , Second Year Services – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment, Calibration Of Ana. Press. Gauge With Meter Dial , Second Year Services – Da Control Panel For 1241 Re/Pe Class – Repair/ Refurbishment, Calibration Of Hour Counter , Second Year Services – Modular Ups For Re/Pe Class – Repair/ Refurbishment, Calibration Of Voltmeter , Second Year Services – Modular Ups For Re/Pe Class – Repair/ Refurbishment, Calibration Of Ammeter , Second Year Services – Modular Ups For Re/Pe Class – Repair/ Refurbishment, Calibration Of Transformer , Second Year Services – Modular Ups For Re/Pe Class – Repair/ Refurbishment, Calibration Of Voltage Controlled Rectifier , Second Year Services – Modular Ups For Re/Pe Class – Repair/ Refurbishment Of Maintenance Free Batteries
|