Refrigerator For Storing Preservatives And Material Stabilizers, Pharmaceutical Refrigerator For Reagents And Preservatives: Useful Volume Of At Least 120 L, Stable Range +2...+8 °C, Electronic Controller, Min/Max Indication, Sound Alarm For Temperature Output, Lock, Forced Air Circulation, Log/Port For Temperature Control., Laboratory Benchtop Centrifuge: Rotor For At Least 12 Tubes Of 10–15 Ml, Speed At Least 4,000 Rpm, Timer, Lid Lock, Protection Against Imbalance And Overheating, Set Of Adapters., Emergency Kit (First Aid Kit/Paramedic Suitcase). Complete Portable Emergency Kit: Durable Medical Suitcase/Bag, Adult Ambu Bag With Masks, Air Ducts, Blood Pressure Monitor, Stethoscope, Pulse Oximeter, Dressings, Splints And Personal Protective Equipment. Medicines - Only According To A Separate Approved List And Subject To Licensing Conditions. The List And Expiration Dates Must Be Agreed Upon Before Delivery., Digital Thermometer For A Refrigerator With An External Sensor: Range No Narrower Than −20...+50 °C, Memory Of Minimum And Maximum Values, Accuracy No Worse Than ±1 °C, Possibility Of Placing The Display Outside The Chamber., Medical Bicycle Ergometer: Programmable Load No Less Than 25–400 W In Steps Of Up To 5 W, Load Maintenance Regardless Of Pedaling Frequency, Adjustable Seat/Steering Wheel, Permissible Patient Weight No Less Than 150 Kg, Interface For Connecting To An Ecg/Pc, Emergency Stop. Installation And Training Included., Electronic Medical Scales With A Stadiometer: Weighing Limit Not Less Than 200 Kg, Discreteness Not More Than 100 G; Growth Range Is Approximately 60–210 Cm In Increments Of No More Than 1 Mm; Bmi Calculation, Stable Base, Verification/Calibration Upon Delivery., Professional Multi-Frequency Segmental Bioimpedance Body Composition Analyzer Without Reference To A Trademark: Separate Analysis Of The Torso And Limbs, Indicators Of Fat And Muscle Mass, Total/Intracellular/Extracellular Water, Visceral Fat, Phase Angle; Printing And Exporting Results, Software And Printer. Installation, Training And Warranty For At Least 12 Months., Electronic Thermo-Hygrometer: Temperature Measurement No Less Than 0...+50 °C And Relative Humidity 20–95%, Display Of Current And Minimum/Maximum Values, Humidity Accuracy No Worse Than ±5%, Tabletop/Wall Mounting., Mechanical Tonometer: Pressure Gauge With A Clear Scale, Adult Cuff Approximately 22–42 Cm, Pump With Valve, Stethoscope And Bag Included; Pressure Error No More Than ±3 Mm Hg. Art., Finger Pulse Oximeter: Spo₂ Measurement In The Range Of No Less Than 70–100% With An Accuracy Of ±2% In The Range Of 80–100%; Pulse Rate Is No Longer 30–250 Beats/Min; Color Display, Charge Indicator, Automatic Shutdown, Batteries And Case Included., Portable Glucometer: Capillary Blood Measurement, Analysis Time No More Than 10 S, Memory Of At Least 200 Results, Automatic Coding Or Without Coding. Set: Device, Lancing Device, At Least 50 Test Strips And 50 Lancets., Medical Electronic Contact Thermometer: Range Not Narrower Than 32–43 °C, Discreteness 0.1 °C, Sound Signal, Auto Shut-Off, Waterproof Tip, Case., Medical Metal Cabinet: Lockable Compartments, At Least Three Shelves, Upper Doors With Glass Or All-Metal As Agreed, Powder Coating Resistant To Disinfection; Approximate Height Of At Least 1650 Mm., Automatic External Defibrillator: Automatic Rhythm Analysis, Voice And Visual Prompts, Adult Mode And Can Be Used For Children, Protection Against Erroneous Discharge, Self-Test, Battery And Adult Electrodes With A Remaining Shelf Life Of At Least 18 Months, Bag. Staff Training Included., Medical Measuring Tape: Length At Least 150 Cm, Scale 1 Mm, Flexible Washable Material, Stable And Contrasting Divisions., Electronic Hand Dynamometer: Range No Less Than 5–90 Kg, Resolution No More Than 0.1 Kg, Adjustable Handle, Results Memory, Screen; Calibration/Functional Check Upon Delivery., Digital Stopwatch: Resolution 1/100 S, Intermediate Time, Memory Of At Least 10 Results, Clock/Timer, Cord And Battery Included., Mobile Medical Examination Lamp: Led Source, Illumination At A Working Distance Of At Least 20,000 Lux, Position Adjustment, Stable Base On Wheels, Low Heating Of The Working Area, 220 V Power Supply., Computer Spirometer: Fvc, Fev1, Fev1/Fvc, Pef And Flow-Volume Measurements; Automatic Assessment Of Maneuver Quality And Reference Values; The Flow Range Is Not Less Than 0–14 L/S, The Volume Is Not Less Than 0–8 L. Software, Calibration Tool Or Factory Calibration, At Least 50 Disposable Mouthpieces., Arch Plantograph: Durable Clear Or Imprint Platform For Adults, Can Image/Imprint Both Feet And Perform Basic Plantographic Measurements, Primary Examination Consumables Included.
|