Medical Equipments – 2 (Two) Linear Accelerator Complete Systems For Radiation Therapy. Two Universally Applicable C-Arm Linear Accelerator Systems Including The Record&Verify System (R&V) For Radiation Therapy Are Available. Both Linear Accelerators Offered Must Be Suitable For A Wide Range Of Radiation Treatments And Radiation Techniques With Very High Precision. Both Systems Must Be Suitable For, Among Other Things, 2D And 3D Igrt, Imrt, Vmat, Sbrt, Srs And Adaptive Radiation Therapy (Art). Both Linear Accelerators Require An Sgrt System And Also Cbct Imaging With The Best Possible Image Quality And Greatest Possible Accuracy (Hu) With The Fastest Possible Image Acquisition. The Two Linear Accelerators Offered Must Be Able To Be Operated In Tandem And Be Matched To One Another. As A Result, Two Identical Mlcs Are Required, Which Must Be Suitable For High-Resolution Beamforming In Srs. Both Linear Accelerators Should Also Contain A Treatment Table (6-D) Which Enables Positioning Correction In Six Degrees Of Freedom (Three Translations (X,Y,Z) And Three Rotations Around The Respective Axes). A Complete System Is Offered Consisting Of Two Linear Accelerator Systems Including All Necessary Additional Systems And Including The Necessary Accessories As Well As A Record And Verify System (R&V). In Addition, All Associated Services Must Be Offered, The Dismantling And Disposal Of The Old Systems, An Associated Full Service Contract And The Provision Of The Required Device-Specific Construction And Installation Services. This Procurement Is A Replacement Procurement. The New Linear Accelerators Must Be Put Into Operation One After The Other So That Radiation Therapy Can Always Ensure Patient Care. The Record&Verify System (R&V) Must Be Operational And Fully Functional When The First New Linear Accelerator Is Commissioned. Both Linear Accelerators Must Be Matched So That They Can Be Used With A Single Set Of Basic Data In Our Existing Treatment Planning System (Raystation). This Is Intended To Avoid Rescheduling/Conversion Between The Two Linear Accelerators Offered, So That Patients Can Easily Switch Between The Devices.
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 118860448
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.