Tender for Annual Rate Contract (Arc) For Repair And Maintenance Works At Block- Badgaon District- Udaipur-1 7.1P & F ISI marked (IS:3854) 6 amp. flush type nonmodular switch with CM/L no. printed and madeout from industrial grade Polycarbonate materialincluding cutting hole in tile and makingconnection testing etc. as required.Each 21.0 12 7.2P & F ISI marked (IS :3854) 16 amp. flush typenon modular switch CM/L no. printed and madeout from industrial grade Polycarbonate materialincluding cutting hole in tile and makingconnection testing etc. as required.Each 48.0 13 7.3Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made outfrom industrial grade Polycarbonate materialincluding cutting hole in tile and makingconnection testing etc. as required.Each 117.0 14 7.4Providing & Fixing of 16 amp. Combined flushtype non modular socket and switch set withindicator and fuse set, made out from industrialgrade Polycarbonate material including cuttinghole in tile and making connection testing etc. asrequired.Each 173.0 15 7.5Providing & Fixing of ISI marked (IS :3854) nonmodular 6A bell push surface type CM/L no.printed and made out from industrial gradePolycarbonate material including makingconnection testing etc. as required.Each 30.0 1Applicable for bid more than 15% below estimated bid value; 50% of unbalanced bid amountPWD Integrated Building BSR 2026,PWD Rajasthan Electrical BSR 2025,All G-Schedule rates are exclusive of GST; GST payable separately as applicablePercentage above/below/at par on applicable ex-GST G-Schedule ratesG-ScheduleAs per Rule 75 of RTPP Rules, 2013State Project Director, Samagra Shiksha, Rajasthan School Education CouncilAnnual Rate Contract / one financial yearUp to ?10 lakh: 2 months; above ?10 lakh and up to ?50 lakh: 4 months?84,74,576Part work order above ?10 lakh: 5 years; up to ?10 lakh: 3 years90 days from opening of technical bid2% of NIT/package amount?1,000?1,500Annual Rate Contract for repair and maintenance worksNIT No. 13 (Civil)/2026-27Salumber67.6Providing & Fixing of ISI marked(IS:3854) twincontrol non modular6A switch surface type,CM/L no. printed and made out from industrialgrade Polycarbonate material, brass terminal &captive screws including making connectiontesting etc. as required.Each 44.0177.7Providing & Fixing of ISI marked(IS:3854) nonmodular6A bell push flush type CM/L no. printedand made out from industrial gradePolycarbonate materialincluding cutting hole intile and making connection testing etc. asrequired.Each 30.0187.10Providing & Fixing of IS:1293 marked of 3 pin 6amp. flush type non modular socket CM/L no.printed and made out from industrial gradePolycarbonate material, brass terminal withPorcelain based back cover & captive screwsincluding cutting hole in tile and makingconnection testing etc. as required.Each 28.0197.11Providing & Fixing of IS:1293 3/6 pin 16 ampflush type non modular socket CM/L no. printedand made out from Industrial gradePolycarbonate material, brass terminal withPorcelain based back cover & captive screwsincluding cutting hole in tile and makingconnection testing etc. as required.Each 73.01107.12Providing & Fixing of ISI marked(IS:371) 6 ampsurface type 3 pin ceiling rose with CM/L no.printed and made out from industrial gradePolycarbonate material, brass terminal & captivescrews including making connection testing etc.as required.Each 28.01117.14Providing & Fixing of ISI marked(IS:1293) 6amp unbreakable 3 pin plug top having lampindicator with CM/L no. printed and made outfrom industrial grade Polycarbonate material,brass terminal including making connectiontesting etc. as required.Each 41.01127.15Providing & Fixing of ISI marked(IS:1293) 16amp unbreakable 3 pin plug top having lampindicator with CM/L no. printed and made outfrom industrial grade Polycarbonate material,brass terminal including making connectiontesting etc. as required.Each 66.01137.16Providing & Fixing of flush type non modular 2pin telephone socket with plug top made outfrom industrial grade Polycarbonate material,brass terminals including making connectiontesting etc. as required.Each 55.01147.20Providing & Fixing of IS 11037 marked nonmodular socket size flush type 100 watt rotaryminimum 5 step fan regulator with CM/L no.printed and made out from industrial gradePolycarbonate material including makingconnection testing etc. as required.Each 186.01157.21P & F ISI marked 32 A D.P. switch with fuse andindicating lamp including making connectiontesting etc. as required.Each 160.01167.22Providing & Fixing of ISI marked(IS:302) gongbell with CM/L no. printed including makingconnection testing etc. as required.Each 166.01177.24Providing & Fixing of single / multi tone electroniccall bell / remote bell including makingconnection testing etc. as required.Each 480.01187.25Providing & Fixing of ISI marked(IS:302) dingdong/musical chime bell including makingconnection testing etc. as required.Each 318.01197.26Providing & Fixing of modular type switch/ bellpush duly ISI marked(IS:3854) with CM/L no.printed and made out of unbreakable and fireretardant virgin UV Stabilized Polycarbonatewith brass terminals and captive screws & silveralloy contact tip with IP-20 rating,minimum widthof switch toggle( PUSH PART) should not lessthen 20mm, including making connections,testing etc as required.1207.26.1 6 A one way switch Each 35.01217.26.6 16 A one way switch1M Each 84.01227.26.9 16 Amp. 2 Module switch With Led Indicator Each 112.01237.26.10 32 Amp. 2 Module switch With Led Indicator Each 162.01247.27Providing & Fixing of IS:1293 marked modulartype lockable feature socket with CM/L no.printed duly made out of unbreakable and fireretardant virgin poly carbonate with brassterminals and captive screws & silver alloycontact tip with IP-20 rating, including makingconnections, testing etc as required.1257.27.1 6 A 3 pin shuttered socket Each 84.01267.27.26/16 A shuttered socket Each 144.01277.28Providing & Fixing of modular type 100W StepFan regulator duly ISI marked(IS 11037) withCM/L no. printed made out of unbreakable andfire retardant virgin poly carbonate with brassterminals and captive screws & silver alloycontact tip with IP-20 rating , including makingconnections, testing etc as required.128 5 step fan regulator 2 Module Each 328.01297.29Providing & Fixing of 3 M Key card switch withLoad capacity 20 amp, Off time delay 30 Sec.made out of unbreakable and fire retardant virginpoly carbonate, including making connections,testing etc as required.Each 312.01307.31Providing & Fixing of following size mountinggrid plates with cover plates made from fireretardent UV established high performanceengineering plastic suitable for all universal metalboxes for front installation & removal direct fittype complete in all respect.1317.31.11/2 Module Each 62.01327.31.2 3 Module Each 82.01337.31.3 4 Module Each 91.01347.31.4 5 Module Each 112.01357.31.5 6 Module Each 131.01367.31.6 8 Module Each 171.01377.31.7 10 Module Each 194.01387.31.8 12 Module Each 205.01397.31.9 16/18 Module Each 231.01407.32Providing & Fixing of following size cover platesmade from fire retardent UV established highperformance engineering plastic suitable for alluniversal metal boxes for front installation &removal direct fit type complete in all respect.1417.32.11/2 Module Each 41.01427.32.2 3 Module Each 57.01437.32.3 4 Module Each 64.01447.32.4 5 Module Each 69.01457.32.5 6 Module Each 92.01467.32.6 8 Module Each 120.01477.32.7 10 Module Each 144.01487.32.8 12 Module Each 146.01497.32.9 16/18 Module Each 161.01507.33Providing & Fixing of Hot dipped Galvanizedmetal box of1.2 mm thick with earthing terminaland adjustable floating clamp in recess/ surfacesuitable for modular accessories as required.1517.33.11-2 Module Each 75.01527.33.2 3 Module Each 110.01537.33.34-5 Module Each 131.01547.33.46-8 Module Each 210.01557.33.5 10-12 Module Each 256.01567.33.6 16/18 Module Each 325.01577.34Providing & Fixing of Wiring Accessories OEMfabricated following size virgin material UPVCmodular boxes on surface suitable for modularaccessories as required.1587.34.11-2 Module Each 81.01597.34.2 3 Module Each 99.01607.34.34/5 Module Each 115.01617.34.4 6 / 8 module Each 168.01627.34.5 10 / 12 module Each 228.01637.34.6 16/18 module Each 330.01647.35Providing & Fixing of Multiple socket with surgeand spikes protection cartridge not less then 5KV with minimum four nos. universal 6 A sockets,one 6 A switch and 3 pin company fitted plug topand 3 core multistrand copper lead minimum1.5mtr. including making connection etc as required.Each 562.01657.36Providing & Fixing of DLP PVC adaptabletrunking system for cable management includingfinishing accessories like corners, tees,adjustable angles, junction etc. as required . Thetrunking system shall have adaptable system formodular type RJ 45 data socket/ wiringaccessories/ power sockets and shall be coveredwith peal off plastic cover. OEM have to submitNABL accrediated/CPET lab test reports/EN50085-2-1 complaince certificate.1667.36.1 80mm x 50mm Mtr. 976.01677.36.2 100/105mm x 50mm Mtr. 1216.01687.36.3 150/160mm x 50mm Mtr. 2125.01697.36.4 195/200mm x 50mm Mtr. 2816.01707.37Providing and fixing of power plug point withnon modular accessories with Galvanized boxof1.2 mm thick with earth terminal with suitablesize3.0 mm thick phenolic laminated sheet(IS:2036 - 1995) cover including cost of 16 amp.Switch(IS :3854) and3/6 pin 16 amp. socketoutlet making connection , testing , etc. asrequired.Each 248.01717.38Supplying and fixing of power plug point withModular accessories on hot dipped galvanizedmodular box of1.2 mm thick with earthingterminal/connector on surface or in recessed withsuitable size of modular face place with grid plateand cover plate including cost of ISI markedmodular 16 amp. Switch(IS:3854) and6/16amp. socket outlet(IS:1293) making connection,testing , etc. as required.Each 460.01727.39P & F Krone module with base frame in therecess / surface made out of1.2 mm thick sheetsteel box, front openable, having lockingarrangements duly powder coated,includingdressing, ferruling and punching of telephonecable with krone tool etc. as required.1737.39.1 10 Pairs Each 791.01747.39.2 20 Pairs Each 1006.01757.39.3 50 Pairs Each 2155.81767.39.4 100 Pairs Each 4312.01777.39.5 200 Pairs Each 7186.01787.40P & F Portable Residual Current Device(PRCD)3 pin plug top 16A, 30 mA sensitivity. Plugshould have feature of power indicator, testbutton and reset function etc. as required.Each 1136.01799.3SITC of 3/4 pole current limiting Moulded casecircuit breaker(MCCB) made of flame retardent& heat resistant material having followingcurrent rating, short circuit breaking capacity at440/415V, 50 Hz;O/L &S/C settings,conforming to IS/IEC 60947 P-2:2003 with frontface and centralised adjustable, trip freemechanisum, true contact position indicator,designed for both horizontal & vertical mountingwithout any adverse effect on electricalperformance, suitable for operation from 50 to55 degree and without derating upto 40 degree,pollution degree3, having positive isolationcapability, push(test) to trip, trip time less then10 ms under s/c condition, Breaking capacity Ics= 100% Icu. U imp=8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth faulttrip, door interlock, pad lock & rotary handle( tobe paid extra) , including making connectionsetc. as required. OEM shall have submit NABL/CPRI / ERDA/ Intertek accrediated lab type testcertificate.1809.3.1 3 pole MCCB With Thermal Magnetic release1819.3.1.1up to 100 Amp , 10 kA, fixed O/L & fixed S/CsettingEach 1506.01829.3.1.2up to 100 Amp , 25 kA, adjustable O/L & FixedS/C setting,Each 4506.01839.3.1.3125 Amp , 25 kA, adjustable O/L & fixed S/Csetting,Each 5483.01849.3.1.4160 Amp , 25 kA, adjustable O/L & fixed S/Csetting,Each 8821.01859.3.1.5200 Amp , 25 kA, adjustable O/L & fixed S/Csetting,Each 11461.01869.3.1.6250 Amp , 25 kA, adjustable O/L & adjustable S/Csetting,Each 13403.01879.3.1.7250 Amp , 35 kA, adjustable O/L & adjustable S/Csetting,Each 13961.01889.3.1.8400 Amp , 35 kA, adjustable O/L & adjustable S/Csetting,Each 17134.01899.3.1.9630 Amp , 50 kA, adjustable O/L & adjustable S/Csetting,Each 24115.01909.3.1.10 800 Amp , 50 kA, adjustable O/L & adjustable S/Csetting,Each 29446.0191 15.1Making of hole in wall(brick/stone) of requiredand placing NP-2 RCC pipe ring of required sizefor housing exhaust fan and making good thesame, with cement plaster required of followingsize.192 15.1.1 Up to 457 mm size Each 319.0193 15.1.2 more than 457 mm & up to 610 mm Each 456.0194 15.2Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up tosize of 300 mm on existing window frameincluding cost of board, cutting of hole , Nut boltsetc. as required.Sqm 1323.0195 15.3Installation , testing and Commissioning of ceilingfan(any size) including wiring the down rod up to30 cm with 3 x1.5 sq.mm pvc insulated flexiblecopper conductor, Cotter pin, rubber grommetmaking connection testing etc. as required.196 15.3.1 With regulator Each 124.0197 15.3.2 Without regulator Each 107.0198 15.4Providing & Fixing BLDC technology stepregulator compatible ceiling fan, with aluminiumbody & aluminium blade, power factor not lessthen0.9 , following service value(CMM/W),with following air delivery , speed 350 RPM(tolerance as per IS:374 2019) THD less then 10%,copper winding with class of Insulation Fcomplete with with secondary support safetycable( steel rope), down rod up to 30 cm, cotterpin, shackle kit with 3 x1.5 sq.mm pvc insulatedflexible copper conductor making connectiontesting etc. as required.199 15.4.11200 mm sweep with Air delivery>/= 230 CMMand Service Value8.20Each 3049.01100 15.4.21400 mm sweep with Air delivery>/= 270 CMMand Service Value7.70Each 3268.01101 15.4.31200 mm sweep with Air delivery>/= 215 CMMand Service Value7.00Each 2725.01102 15.4.41400 mm sweep with Air delivery>/= 260 CMMand Service Value6.4Each 2921.01103 15.5Providing& Fixing of of BLDC Technologyventilating fans, single phase with PVC impeller,ABS body, Double Ball bearing, automatic backlower shutter including making connection,testing etc. as required.1104 15.5.1150 mm sweep with Min. Air delivery 350 Cubicmeter/Hr, 2000 RPMEach 2153.01105 15.5.2200 mm sweep with Min. Air delivery 800 Cubicmeter/Hr, 1600 RPMEach 2326.01106 15.5.3250 mm sweep with Min. Air delivery 1150 Cubicmeter/Hr, 1300 RPMEach 2534.01107 17.1SITC of IP20 SMD Mid Power LED batten typeintegrated light fixture made from Powder coatedExtruded aluminium housing with in built driver,System lumen efficacy = 110 lm/Watt output only atCW(5700K to 6500K) , internal surge protection of4.0KV with Short & Open circuit protection,THD < 10%,P.F.=0.95, CRI>80 , life time of minimum 50000Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.1108 17.1.11170mm(+/-10%) LED batten with min. lumen output2200 lmEach 396.01109 17.1.2570mm(+/-10%) batten with min. lumen output 1000lmEach 322.01110 17.1.31170mm(+/-10%) LED batten with min. lumen output4400 lmEach 690.01111 17.2SITC of IP20 SMD Mid Power LED batten withintegrated box(min.1200mmx40mmx60mmincluding reflector) with replacable driver fixturemade from Powder coated Extruded aluminiumhousing,Min. lumen output 4800 lm, System lumenefficacy = 120 lm/Watt output nly at CW(5700K to6500K), internal surge protection of4.0 KV with Short& Open circuit protection,THD < 10% ,P.F.=0.95, CRI>80 , life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends , CCT3000°K / 4000°K / 5700°K/6000°K/6500°K(As perANSI Bin) as required.Each 1472.01112 17.3SITC of IP-20 LED Recessed / Surface Mounted, Round/ Square backlit & SMD Mid Power LED Downlightwith power coated die-cast aluminum housing withUV Stabilized non yellowish Diffuser with BIScompliance4.0 KV surge protected Isolated driver,with Short & Open circuit protection input 320VAC-48hr protection, input 350VAC-2 hr protection), havingefficiency > 85% . System Lumen efficacy of = 110 lm/watt,at CW(5700K to 6500K) , THD < 10 % , Pf.=0.95,CRI>80, life time of minimum 50000 Burning Hourswith , 70% of intial Lumen maintaned till life ends,CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(As perANSI Bin) as required.1113 17.3.1 Recessed Mounting1114 17.3.1.1Minimum lumen output 600 lm(lumen efficacy = 100lm / watt)Each 566.01115 17.3.1.2 Minimum lumen output 1300 lm Each 815.01116 17.3.1.3 Minimum lumen output 1600 lm Each 932.01117 17.3.1.4 Minimum lumen output 1950 lm Each 1098.01118 17.3.1.5 Minimum lumen output 2400 lm Each 1328.01119 17.3.2Surface Mounting (with extruded alumn. Housing )1120 17.3.2.1Minimum lumen output 600 lm(lumen efficacy = 100lm / watt)Each 663.01121 17.3.2.2 Minimum lumen output 1300 lm Each 909.01122 17.3.2.3 Minimum lumen output 1600 lm Each 1002.01123 17.3.2.4 Minimum lumen output 1950 lm Each 1211.01124 17.3.2.5 Minimum lumen output 2400 lm Each 1464.01125 17.4SITC of IP20,2x2 LED Surface/ Recessed mountingbacklit & SMD Mid power type LED Light fixture notless than 35 mm housing depth made from CRCAsheet steel housing, high purity / transmissivity UVstabilized Non-yellowish diffuser for uniform lightdistribution. operating voltage range 140-285V, HVcutoff - LV cutoff should be 300-100V . High efficiencywith 4 KV internal surge protection BIS certifiedisolated driver having efficiency > 85% , with Short&Open circuit protection( input 320VAC-48hoursprotection,input 350VAC-2 hours protection)(Integral with light fixture). System lumen efficacy of=120 lm/Watt,THD < 10 % ,p.f.=0.95,CRI>80 , lifetime of minimum 50000 Burning Hours with , 70% ofintial Lumen maintaned till life ends , CCT 3000°K/4000°K / 5700°K/6000°K/6500°K(As per ANSI Bin) asrequired.1126 17.4.1 Recessed Mounting1127 17.4.1.1 Minimum lumen output 4320 lm Each 2019.01128 17.4.1.2 Minimum lumen output 4800 lm Each 2265.01129 17.4.2Surface Mounting (Driver should be Inside theLuminaire)1130 17.4.2.1 Minimum lumen output 4320 lm Each 2334.01131 17.4.2.2 Minimum lumen output 4800 lm Each 2599.01132 17.5SITC of IP20,1X1 LED Surface/ Recessed mountingbacklit & SMD Mid power type LED Light fixture notless than 35 mm housing depth made from CRCAsheet steel housing, high purity / transmisivity UVstabilized Non-yellowish diffuser for uniform lightdistribution.operating voltage range 140-285V, HVcutoff - LV cutoff should be 300-100V High efficiencywith 4 KV internal surge protection BIS certifiedisolated driver having efficiency > 85% , with Short&Open circuit protection(Integral with light fixture).System lumen efficacy of = 120 lm/Watt,THD < 10 %,p.f.=0.95,CRI>80 , life time of minimum 50000Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.1133 17.5.1 Recessed Mounting1134 17.5.1.1 Minimum lumen output 2880 lm Each 1302.01135 17.5.1.2 Minimum lumen output 3600 lm Each 1415.01136 17.5.2Surface Mounting (Driver should be Inside theLuminaire)1137 17.5.2.1 Minimum lumen output 2880 lm Each 1359.01138 17.5.2.2 Minimum lumen output 3600 lm Each 1472.01139 17.6SITC of IP20,1x4 LED Surface/ Recessed mountingMid power SMD type LED Light fixture not less than35 mm housing depth made from CRCA sheet steelhousing, high purity / transmisivity UV stabilized Non-yellowish diffuser for uniform light distribution.operating voltage range 140-285V, HV cutoff - LVcutoff should be 300-100V. High efficiency with 4 KVinternal surge protection BIS certified isolated driverhaving efficiency > 85% , with Short & Open circuitprotection(Integral with light fixture). System lumenefficacy of = 120 lm/Watt,THD < 10 % ,p.f.=0.95,CRI>80 , life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends , CCT3000°K / 4000°K / 5700°K/6000°K/6500°K(As perANSI Bin) as required.1140 17.6.1 Recessed Mounting1141 17.6.1.1 Minimum lumen output 4320 lm Each 1982.01142 17.6.1.2 Minimum lumen output 4800 lm Each 2152.01143 17.6.2Surface Mounting (Driver should be Inside theLuminaire)1144 17.6.2.1 Minimum lumen output 4320 lm Each 2039.01145 17.6.2.2 Minimum lumen output 4800 lm Each 22009.01146 17.7SITC of IP20, 1100-1200 mm x 50-60 mm x 70-85 mmsize Suspended mounting backlit & SMD mid powertype LED linear Light fixture made from ExtrudedAluminium housing, PMMA Acrylic/ExtrudedPolycarbonate push fit type diffuser for uniform lightdistribution. High efficiency with 4 KV internal surgeprotection BIS certified isolated driver havingefficiency > 85% , with Short & Open circuitprotection(Integral with light fixture). Lumen Efficacywill be>=100lm/W only at CW(5700K to 6500K),THD< 10 % ,p.f.=0.95,CRI>80 , life time of minimum50000 Burning Hours with , 70% of intial Lumenmaintaned till life ends , CCT 3000°K / 4000°K/5700°K/6000°K/6500°K(As per ANSI Bin) , maximumpower consumption should not more than thespecified rating . Luminiare can connect each otherthrough jointer kit(cost of jointer kit is included) asrequired.1147 17.7.1 Minimum lumen output 2000 lm Each 3681.01148 17.7.2 Minimum lumen output 3000 lm Each 4361.01149 17.8SITC of IP65 IK08 rated Integrated High power LED(each LED between 3 to 5 watt power with secondarylencs on each LED) Highbay light fixture made fromPressure Die Cast Aluminium housing, UV stabilizedPC Cover/ Toughened glass diffuser, potted driver,Eye bolt for mounting, system lumen efficacy=150lm/Watt output , THD < 10%,p.f.=0.95,CRI>70 , lifetime of minimum 50000 Burning Hours with , 70% ofintial Lumen maintaned till life ends , CCT 3000°K/4000°K / 5700°K/6000°K/6500°K(As per ANSI Bin),maximum power consumption should not more thanthe specified rating and . surge protection 4 KV inbuilt& 10 KV external inside fixture as required.1150 17.8.1 Minimum lumen output 12000 lm Each 5454.01151 17.8.2 Minimum lumen output 15000 lm Each 5946.01152 17.8.3 Minimum lumen output 18000 lm Each 7230.01153 17.8.4 Minimum lumen output 22500 lm Each 8043.01154 17.9SITC of Suspended mounting IP66 IK08 ratedIntegrated High power LED Wellglass light fixturemade from Pressure Die Cast Aluminium housing,potted driver, Eye bolt for mounting, PC clear / OpalDiffuser, system lumen efficacy=130 lm/Watt outputonly at CW(5700K to 6500K) , THD < 10%,p.f.=0.95,CRI>70 , life time of minimum 50000Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum powerconsumption should not more than the specifiedrating surge protection 4 KV inbuilt & 10 KV externalinside fixture as required.1155 17.9.1 Minimum lumen output 4550 lm Each 2093.01156 17.9.2 Minimum lumen output 9100 lm Each 2787.01157 17.11SITC of IP 20 box made out from1.0 mm thick CRCAsheet steel with depth of minimun 30 mm andfinished with powder coating and suitable formounting LED tube including side covers, holders,internal wiring to illuminate the single sidedconnection LED tube.( Without tube).1158 17.11.1Suitable for2 LED Tube shape fixture for single rod Each 158.01159 17.11.2Suitable for4 LED Tube shape fixture for single rod Each 249.01160 17.11.3Suitable for4 LED Tube shape fixture for double rod Each 317.01161 17.12SITC of energy efficient direct fit(Retrofit)Polycarbonate/ Glass housing SMD Mid Power LEDtube rod(with integral driver & alumn. heat sink), onexisting fixture. system lumen efficacy = 100 lm/Wattoutputonly at CW(5700K to 6500K) , internal surgeprotection of2.5 KV,THD < 15%,p.f.=0.95,CRI>80,life time of minimum 35000 Burning Hours with , 70%of intial Lumen maintaned till life ends , CCT 3000°K/4000°K / 5700°K/6000°K/6500°K(As per ANSI Bin) asrequired.1162 17.12.1600mm , Min. Lumens output 1800 lm LED Tube rodwith Polycarbonate HousingEach 215.01163 17.12.21200mm , Min. Lumens output 2000 lm LED Tube rodwith Polycarbonate HousingEach 260.01164 17.12.31200mm, Min. Lumens output 2000 lm LED Tube rodwith Glass HousingEach 238.01165 17.13SITC of IP65 IK08 rated Integrated SMD Mid powerLED bulk head type light fixture made from PressureDie Cast AL housing suitable with integral driver,system lumen efficacy=120 lm/Watt output only atCW(5700K to 6500K) , THD < 15%,p.f.=0.95,CRI>80,life time of minimum 50000 Burning Hours with , 70%of intial Lumen maintaned till life ends , CCT 3000°K/4000°K / 5700°K/6000°K/6500°K(As per ANSI Bin) asrequired.1166 17.13.1 Minimum lumen output 1200 lm Each 1386.01167 17.14SITC of IP-20 LED Recessed / Surface Mounted, Round/ Sqaure backlit & SMD Mid Power LED Downlightwith power coated die-cast aluminum housing withUV Stabilized non yellowish Diffuser with BIScomplience4.0 KV surge protected Isolated driver,with Short & Open circuit protection input 320VAC-48hr protection, input 350VAC-2 hr protection), havingefficiency > 85% . System Lumen efficacy of = 110 lm/watt,at CW(5700K to 6500K) , THD < 10 % , Pf.=0.95,CRI>80, UGR(unified glare rating)<19, fliker free(current ripple should be below5%), SDCm(standarddeviation colour matching)<5.life time of minimum50000 Burning Hours with , 70% of intial Lumenmaintaned till life ends , CCT 3000°K / 4000°K/5700°K/6000°K/6500°K(As per ANSI Bin) as required.1168 17.14.1 Recessed Mounting1169 17.14.1.1 Minimum lumen output 1300 lm Each 1119.01170 17.14.1.2 Minimum lumen output 1600 lm Each 1279.01171 17.14.1.3 Minimum lumen output 1950 lm Each 1515.01172 17.14.1.4 Minimum lumen output 2400 lm Each 1835.01173 17.14.2Surface Mounting (with extruded alumn. Housing )1174 17.14.2.1 Minimum lumen output 1300 lm Each 1234.01175 17.14.2.2. Minimum lumen output 1600 lm Each 1364.01176 17.14.2.3 Minimum lumen output 1950 lm Each 1772.01177 17.14.2.4 Minimum lumen output 2400 lm Each 2067.01178 17.15SITC of IP20,2x2 LED Surface/ Recessed mountingbacklit & SMD Mid power type LED Light fixture notless than 35 mm housing depth made from CRCAsheet steel housing, high purity / transmisivity UVstabilized Non-yellowish diffuser for uniform lightdistribution. operating voltage range 140-285V, HVcutoff - LV cutoff should be 300-100V . High efficiencywith 4 KV internal surge protection BIS certifiedisolated driver having efficiency > 85% , with Short&Open circuit protection( input 320VAC-48hoursprotection,input 350VAC-2 hours protection)(Integral with light fixture). System lumen efficacy of=120 lm/Watt,THD < 10 % ,p.f.=0.95,CRI>80 , UGR(unified glare rating)<19, fliker free(current rippleshould be below5%), SDCm(standard deviationcolour matching)<5 life time of minimum 50000Burning Hours with , 70% of intial Lumen maintanedtill life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.1179 17.15.1 Recessed Mounting1180 17.15.1.1 Minimum lumen output 4320 lm Each 2719.01181 17.15.1.2 Minimum lumen output 4800 lm Each 3229.01182 17.15.2Surface Mounting (Driver should be Inside theLuminaire)1183 17.15.2.1 Minimum lumen output 4320 lm Each 2939.01184 17.15.2.2 Minimum lumen output 4800 lm Each 3449.01185 17.16SITC of IP20,1x4 LED Surface/ Recessed mountingMid power SMD type LED Light fixture not less than35 mm housing depth made from CRCA sheet steelhousing, high purity / transmisivity UV stabilized Non-yellowish diffuser for uniform light distribution.operating voltage range 140-285V, HV cutoff - LVcutoff should be 300-100V. High efficiency with 4 KVinternal surge protection BIS certified isolated driverhaving efficiency > 85% , with Short & Open circuitprotection(Integral with light fixture). System lumenefficacy of = 120 lm/Watt,THD < 10 % ,p.f.=0.95,CRI>80 , UGR(unified glare rating)<19, fliker free(current ripple should be below5%), SDCM(standarddeviation colour matching)<5life time of minimum50000 Burning Hours with , 70% of intial Lumenmaintaned till life ends , CCT 3000°K / 4000°K/5700°K/6000°K/6500°K(As per ANSI Bin) as required.1186 17.16.1 Recessed Mounting1187 17.16.1.1 Minimum lumen output 4320 lm Each 2889.01188 17.16.1.2 Minimum lumen output 4800 lm Each 3115.01189 17.16.2Surface Mounting (Driver should be Inside theLuminaire)1190 17.16.2.1 Minimum lumen output 4320 lm Each 3059.01191 17.16.2.2 Minimum lumen output 4800 lm Each 3285.01192 17.17SITC of IP20,1X1 LED Surface/ Recessed mountingbacklit & SMD Mid power type LED Light fixture notless than 35 mm housing depth made from CRCAsheet steel housing, high purity / transmisivity UVstabilized Non-yellowish diffuser for uniform lightdistribution.operating voltage range 140-285V, HVcutoff - LV cutoff should be 300-100V High efficiencywith 4 KV internal surge protection BIS certifiedisolated driver having efficiency > 85% , with Short&Open circuit protection(Integral with light fixture).System lumen efficacy of = 120 lm/Watt,THD < 10 %,p.f.=0.95,CRI>80 , UGR(unified glare rating)<19,fliker free(current ripple should be below5%), SDCM(standard deviation colour matching)<5 life time ofminimum 50000 Burning Hours with , 70% of intialLumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(As per ANSI Bin) asrequired.1193 17.17.1 Recessed Mounting1194 17.17.1.1 Minimum lumen output 2880 lm Each 1642.01195 17.17.1.2 Minimum lumen output 3600 lm Each 1840.01196 17.17.2Surface Mounting (Driver should be Inside theLuminaire)1197 17.17.2.1 Minimum lumen output 2880 lm Each 1812.01198 17.17.2.2 Minimum lumen output 3600 lm Each 1959.01199 17.18SITC of IP-20 LED Recessed Mounted, Round backlit&COB type LED Downlighter of Powder Coateddiecast/Extruded Aluminium body including trim withaluminium deflector and construction as per IS:10322with2.5 KV surge protected Isolated driver with Short& Open circuit protection(Input 320VAC-48 hoursprotection, Input 350VAC-2 hours protection) havingefficiency > 85%, operating voltage 140-270 V AC.System Lumen efficacy of = 100 lm/watt, at CW(5700K to 6500K) , THD < 10 % , Pf.=0.95, CRI>80,UGR(Unified Glare Rating)< 19, Fliker free(currentripple should be below5%), SDCM(StandardDeviation Color Matching) <5, life time of minimum50000 Burning Hours with 70% of intial Lumenmaintaned till life ends , CCT 3000°K / 4000°K/5700°K/6000°K/6500°K(As per ANSI Bin) as required.1200 17.18.1 lumen output 550 lm to 770 lm Each 792.01201 17.18.2 lumen output 880 lm to 1100 lm Each 1132.01202 17.18.3 lumen output 1320 lm to 1650 lm Each 1415.012031.1Wiring of light point/ fan point/ exhaust fanpoint/ call bell point with1.5 sq. mm nominalsize FR PVC insulated unsheathed flexible class2copper conductor1.1 kV grade and1.5 sq. mmnominal size FR PVC insulated unsheathedflexible class 2 copper earth conductor1.1 kVgrade(IS:694) in recessed ISI marked MMS(IS:9537 P - III) PVC conduit & its ISI marked(IS:3419-1988) accessories, Aluminum roundtiles,1.2 mm thick Hot Dipped GalvanizedModular Box with earth terminal, 6 A Modularswitch, Modular face plate with grid plate, 3 pinceiling rose / Holder/3 way connector, screws,making connections, testing etc. as required.12041.1.1 Short point(up to 3 mtr.) P. point 291.012051.1.2 Medium point(up to 6 mtr.) P. point 509.012061.1.3 Long point(up to 10 mtr.) P. point 699.012071.2Wiring of twin control light point with1.5 sq. mmnominal size FR PVC insulated unsheathedflexible class 2 copper conductor1.1 kV gradeand1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper earthconductor1.1 kV grade(IS:694) in recessed ISImarked MMS( IS:9537 P - III) PVC conduit & itsISI marked(IS:3419-1988) accessories,Aluminium round tiles, 2 Nos Hot DippedGalvanized M.S Modular box of1.2 mm thickwith earth terminal,2 Nos 6 A two way Modularswitch, 3 pin ceiling rose / holder / 3 wayconnector,Modular face plate with grid plate,screws, making connections, testing etc. asrequired.12081.2.1 Short point(up to 3 mtr.) P. point 578.012091.2.2 Medium point(up to 6 mtr.) P. point 1014.012101.2.3 Long point(up to 10 mtr.) P. point 1395.01211 1.3Wiring of3/5 pin 6 amp. Light plug point with1.5sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper conductor1.1kV grade and1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible class 2 copperearth conductor1.1 kV grade(IS:694) inrecessed ISI marked MMS( IS:9537 P - III) PVCconduit & its ISI marked(IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of1.2 mm thick with earthterminal, 6 A modular switch,3/5 pin 6Amodular socket, Modular face plate with gridplate, screws, making connections, testing etc.as required.12121.3.1 On board P. point 324.012131.3.2 Short point(up to 3 mtr.) P. point 467.012141.3.3 Medium point(up to 6 mtr.) P. point 685.012151.3.4 Long point(up to 10 mtr..) P. point 875.012161.4S&F following sizes(dia.) of ISI marked MMS(IS:9537 P - III) PVC conduit along with ISImarked(IS:3419-1988) accessories as requiredin recess including making jhiri in thewall,clamps at suitable spacing, covering conduitand making good the same as required.12171.4.1 20 mm Mtr. 33.012181.4.2 25 mm Mtr. 47.012191.4.3 32 mm Mtr. 70.012201.4.4 40 mm Mtr. 101.012211.4.5 50 mm Mtr. 152.01222Recessed PVC Conduit Wiring with NonModular accessories12231.5Wiring of light point/ fan point/ exhaust fanpoint/ call bell point with1.5 sq. mm nominalsize FR PVC insulated unsheathed flexible class2copper conductor1.1 kV grade and1.5 sq. mmnominal size FR PVC insulated unsheathedflexible class 2 copper earth conductor1.1 kVgrade(IS:694) in recessed ISI marked MMS(IS:9537 P - III) PVC conduit & its ISI marked(IS:3419-1988) accessories, Aluminium roundtiles,1.2 mm thick Hot dipped Galavanized MSbox with earth terminal, 6 A switch, 3 pin ceilingrose/holder / 3 way connector ,3.0 mm thick ISImarked(IS:2036-1995) phenolic laminated sheet,Al.alloy / Cadmium plated iron/ brass screws,cup washers, making connections, testing etc. asrequired.12241.5.1 Short point(up to 3 mtr.) P. point 213.012251.5.2 Medium point(up to 6 mtr.) P. point 431.012261.5.3 Long point(up to 10 mtr.) P. point 621.012271.6Wiring of twin control light point with1.5 sq.mm nominal size FR PVC insulated unsheathedflexible class 2 copper conductor1.1 kV gradeand1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper earthconductor1.1 kV grade(IS:694) in recessed ISImarked MMS( IS:9537 P - III) PVC conduit&its ISI marked(IS:3419-1988) accessories,Aluminium round tiles, 2 Nos1.2 mm thick Hotdipped Galavanized MS box with earth terminal,2 Nos 6 A two way switch,3 pin ceiling rose/holder/ 3 way connector,3.0 mm thick ISImarked(IS:2036-1995) phenolic laminated sheet,Al.alloy / Cadmium plated iron/ brass screws,cup washers, making connections, testing etc. asrequired.12281.6.1 Short point(up to 3 mtr.) P. point 402.012291.6.2 Medium point(up to 6 mtr.) P. point 839.012301.6.3 Long point(up to 10 mtr..) P. point 1219.012311.7Wiring of3/5 pin 6 amp. Light plug point with1.5sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper conductor1.1kV grade and1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible class 2 copperearth conductor1.1 kV grade(IS:694) inrecessed ISI marked MMS( IS:9537 P - III) PVCconduit & its ISI marked(IS:3419-1988)accessories,1.2 mm thick Hot dippedGalavanized MS box with earth terminal ofrequired size, 6 A switch,3/5 pin 6 A socket,3.0mm thick ISI marked(IS:2036-1995) phenoliclaminated sheet, Al.alloy / Cadmium plated iron/brass screws, cup washers, making connections,testing etc. as required.12321.7.1 On board P. point 114.012331.7.2 Short point(up to 3 mtr.) P. point 248.012341.7.3 Medium point(up to 6 mtr.) P. point 466.012351.7.4 Long point(up to 10 mtr..) P. point 656.012361.8S&F of following sizes of polypropelenecorrugated flexible conduit including gland onboth side of flexible conduit as required.12371.8.1 16 mm OD Mtr. 10.012381.8.2 20 mm OD Mtr. 13.012391.8.3 25 mm OD Mtr. 18.012401.8.4 32 mm OD Mtr. 30.012411.8.5 40 mm OD Mtr. 37.01242Surface PVC Conduit Wiring withModular accessories12431.9Wiring of light point/ fan point/ exhaust fanpoint/ call bell point with1.5 sq. mm nominalsize FR PVC insulated unsheathed flexible class2copper conductor1.1 kV grade and1.5 sq. mmnominal size FR PVC insulated unsheathedflexible class 2 copper earth conductor1.1 kVgrade(IS:694) on surface ISI marked MMS(IS:9537 P - III) PVC conduit & its ISI marked(IS:3419-1988) accessories, round tiles,1.2 mmthick Hot Dipped Galvanized Modular Box withearth terminal/Surface mounted UPVC moldedmodular box, 6 A Modular switch,Modular faceplate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections,testing etc. as required.12441.9.1 Short point(up to 3 mtr.) P. point 279.012451.9.2 Medium point(up to 6 mtr.) P. point 488.012461.9.3 Long point(up to 10 mtr.) P. point 671.012471.10.Wiring of twin control light point with1.5 sq. mmnominal size FR PVC insulated unsheathedflexible class 2 copper conductor1.1 kV gradeand1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper earthconductor1.1 kV grade(IS:694) on surface ISImarked MMS( IS:9537 P - III) PVC conduit & itsISI marked(IS:3419-1988) accessories, roundtiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of1.2 mm thick with earth terminal/Surfacemounted UPVC molded modular box, 2 Nos 6Atwo way Modular switch, 3 pin ceiling rose/holder / 3 way connector,Modular face platewith grid plate, screws, making connections,testing etc. as required.12481.10.1 Short point(up to 3 mtr.) P. point 554.012491.10.2 Medium point(up to 6 mtr.) P. point 973.012501.10.3 Long point(up to 10 mtr.) P. point 1104.01251 1.11Wiring of3/5 pin 6 amp. Light plug point with1.5sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper conductor1.1kV grade and1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible class 2 copperearth conductor1.1 kV grade(IS:694) on surfaceISI marked MMS( IS:9537 P - III) PVC conduit&its ISI marked(IS:3419-1988)accessories, HotDipped Galvanized Modular box of1.2 mm thickwith earth terminal/Surface mounted UPVCmolded modular box, 6 A modular switch,3/5pin 6 A modular socket, Modular face plate withgrid plate, screws, making connections, testingetc. as required.12521.11.1 On board P. point 310.012531.11.2 Short point(up to 3 mtr.) P. point 448.012541.11.3 Medium point(up to 6 mtr.) P. point 657.012551.11.4 Long point(up to 10 mtr..) P. point 840.012561.12S&F following sizes(dia.) of ISI marked MMS(IS:9537 P - III) PVC conduit along with ISImarked(IS:3419-1988) accessories as requiredon surface including heavy duty saddles withbase at spacing of0.60 mtr. etc as required.12571.12.1 20 mm Mtr. 32.012581.12.2 25 mm Mtr. 45.012591.12.3 32 mm Mtr. 67.012601.12.4 40 mm Mtr. 97.012611.12.5 50 mm Mtr. 146.01262Surface PVC Conduit Wiring with NonModular accessories12631.13Wiring of light point/ fan point/ exhaust fanpoint/ call bell point with1.5 sq. mm nominalsize FR PVC insulated unsheathed flexible class2copper conductor1.1 kV grade and1.5 sq. mmnominal size FR PVC insulated unsheathedflexible class 2 copper earth conductor1.1 kVgrade(IS:694) on surface ISI marked MMS(IS:9537 P - III) PVC conduit & its ISI marked(IS:3419-1988) accessories, round tiles,1.2 mmthick Hot dipped Galvanized MS box with earthterminal of required size , 6 A switch, 3 pinceiling rose/holder / 3 way connector ,3.0 mmthick ISI marked(IS:2036-1995) phenoliclaminated sheet, Al.alloy / Cadmium plated iron/brass screws, cup washers, making connections,testing etc. as required.12641.13.1 Short point(up to 3 mtr.) P. point 204.012651.13.2 Medium point(up to 6 mtr.) P. point 414.012661.13.3 Long point(up to 10 mtr.) P. point 596.012671.14Wiring of twin control light point with1.5 sq. mmnominal size FR PVC insulated unsheathedflexible class 2 copper conductor1.1 kV gradeand1.5 sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper earthconductor1.1 kV grade(IS:694) on surface ISImarked MMS( IS:9537 P - III) PVC conduit&its ISI marked(IS:3419-1988) accessories, roundtiles, 2 Nos1.2 mm thick Hot dipped GalvanizedMS box with earth terminal of required size,2Nos 6 A two way switch,3 pin ceiling rose/holder/ 3 way connector,3.0 mm thick ISImarked(IS:2036-1995) phenolic laminated sheet,Al.alloy / Cadmium plated iron/ brass screws,cup washers, making connections, testing etc. asrequired.12681.14.1 Short point(up to 3 mtr.) P. point 386.012691.14.2 Medium point(up to 6 mtr.) P. point 804.012701.14.3 Long point(up to 10 mtr..) P. point 1169.012711.15Wiring of3/5 pin 6 amp. Light plug point with1.5sq. mm nominal size FR PVC insulatedunsheathed flexible class 2 copper conductor1.1kV grade and1.5 sq. mm nominal size FR PVCinsulated unsheathed flexible class 2 copperearth conductor1.1 kV grade(IS:694) on surfaceISI marked MMS( IS:9537 P - III) PVC conduit&its ISI marked(IS:3419-1988) accessories,1.2mm thick Hot dipped Galvanized MS box withearth terminal of required size, 6 A switch,3/5pin 6 A socket,3.0 mm thick ISI marked(IS:2036-1995) phenolic laminated sheet, Al.alloy/Cadmium plated iron/ brass screws, cupwashers, making connections, testing etc. asrequired.12721.15.1 On board P. point 109.012731.15.2 Short point(up to 3 mtr.) P. point 238.012741.15.3 Medium point(up to 6 mtr.) P. point 447.012751.15.4 Long point(up to 10 mtr..) P. point 630.01276 1.2Earth work in rough excavation, bankingexcavated earth in layers not exceeding 20cm indepth, breaking clods watering, rolling each layerwith1/2 tonne roller, or stone or steel rammersand rolling every3rd and top- most layer withpower roller of minimum8-10 tonne capacity anddressing up in embankment for roads, floodbanks marginal banks and guide banks or fillingup ground depressions, lead up to 50 Mtr. and liftup to1.5 Mtr.: All kinds of soilCum 272.001277 1.3Banking excavated earth in layers not exceeding20cm. in depth breaking clods watering, rollingeach layer with1/2 tonne roller, or stone or steelrammers, and rolling every3rd and top- mostlayer with power roller of8-10 tonne capacity anddressing up in embankments for roads, floodbanks marginal banks, and guide banks etc. leadup to 50 Mtr. and lift up to1.5 Mtr. All kinds ofsoilsCum 171.001278 1.4Deduct for not rolling with power roller of 8 to 10tonne capacity for banking excavated earth inlayers not exceeding 20 cm in depthCum 3.001279 1.5 Deduct for not watering the excavated earth forbanking. Cum 12.001280 1.6Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as wellas 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m and lift upto1.5m , disposed earth to be levelled and neatlydressed:All kinds of soilCum 175.001281 1.7Earth work in excavation/ by mechanical means (Hydraulic Excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5m in width as wellas 10 sqm on plan) including disposal ofexcavated earth, lead upto 50 m and lift upto1.5m , disposed earth to be levelled and neatlydressed: 1282 1.7.1 Ordinary rock Cum 251.001283 1.8Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means infoundation trenches or drains(not exceeding1.5m in width or 10 sqm on plan) including dressingof sides and ramming of bottoms, lift upto1.5m,including taking out the excavated soil anddepositing and refilling of jhiri with watering &ramming and disposal of surplus excavated soilas directed with in a lead of 50 meter. All kinds ofsoilsCum 178.001284 1.9Excavation work by mechanical means (Hydraulic excavator) / manual means infoundation trenches or drains not exceeding1.5m in width or 10 sqm on plan including dressingof sides and ramming of bottoms lift upto1.5m,including getting out the excavated soil anddisposal of surplus excavated soil as directedwith a lead in a 50 meter including stacking ofuseful material if available:1285 1.9.1 Ordinary rock Cum 268.001286 1.20.1 Depth not exceeding1.5 Mtr. Sqm 47.001287 1.20.2 Depth exceeding1.5 Mtr. but not exceeding 3 Mtr Sqm 50.001288 1.20.3 Depth exceeding 3 Mtr. but not exceeding4.5 Mtr Sqm 54.001289 1.21P & F of Open timbering in case of shafts, wells,soak pits, manholes and the like includingstrutting, shoring complete (Measurement to betaken of the face area timbered):1290 1.21.1 Depth not exceeding1.5 Mtr. Sqm 41.001291 1.21.2 Depth exceeding1.5 Mtr. but not exceeding 3 Mtr Sqm 46.001292 1.21.3 Depth exceeding 3 Mtr. but not exceeding4.5 Mtr Sqm 53.001293 1.22P & F Open timbering over area includingstrutting, shoring etc complete (Measurement tobe taken of the face area timbered):1294 1.22.1 Depth not exceeding1.5 Mtr. Sqm 30.001295 1.22.2 Depth exceeding1.5 Mtr. but not exceeding 3 Mtr Sqm 32.001296 1.22.3 Depth exceeding 3 Mtr. but not exceeding4.5 Mtr Sqm 39.001297 1.23Add extra for planking and strutting in opentimbering if required to be left permanently inposition (face area of timber permanently left tobe measured)Sqm 629.001298 1.24 Add extra rate for quantities of works, executed :1299 1.24.1In or under water and/or liquid mud, includingpumping out water as P.Mtr. 20% required depth1300 1.24.2In or under foul position , including pumping outwater as required P.Mtr. 25% depth Note for itemno.1.24:- The extra percentage rate is applicablein respect of each item but limited to quantities ofwork executed in these difficult conditions. Theunit, namely, metre depth, to be considered forpayment, shall be the depth measured from thesub soil water level up to the centre of gravity ofthe qty executed in difficult condition. The depthshall be reckoned correct to0.10m,0.05m ormore shall be taken as0.10m and less than0.05m ignorel. 1301 1.25Filling available excavated earth(excluding rock)in trenches, plinth side of foundation etc. in layersnot exceeding 20 cm. in depth, consolidatingeach deposited layer by ramming and wateringincluding lead up to 50 meter and with all lift.Cum 64.001302 1.26 Add extra for foundation/trenches/drains forevery additional lift of1.5 Mtr. or part thereof in1303 1.26.1 All kinds of soil Cum 34.001304 1.26.2Ordinary or hard rock.1.27(a) Supplying andFilling in plinth with river sand under floorsincluding Cum 1024.00 watering rammingconsolidating and dressing complete includingcost of sand1.27(b) Supplying and Filling inplinth with blown sand under floors includingCum 450.00 watering ramming consolidating anddressing complete including cost of sand.Cum 61.001305 1.28Surface dressing of the ground includingremoving vegetation and inequalities notexceeding 15cm deep and disposal of rubbishlead up to 50 Mtr. and lift up to1.5 Mtr.:All kindsof soilSqm 9.001306 1.29Ploughing the existing ground to a depth of 15cm to 25 cm and watering the same: All kinds ofsoilSqm 9.001307 1.30Excavating holes upto0.5 cum including gettingout the excavated soil, then returning the soil asrequired in layers not exceeding 20 cm in depth,including consolidating each deposited layer byramming, watering etc disposing of surplusexcavted soil; as directed within a lead of 50 mand lift to1.5m1308 1.30.1 All kinds of soil Cum 94.001309 1.30.2 Ordinary rock Cum 135.001310 1.30.3 Hard rock(requiring blasting) useful material 30% Cum 243.001311 1.30.4 Hard rock(blasting prohibited) useful material 30% Cum 296.001312 3.1Providing and laying in position cement concreteincluding curing, compaction etc. complete inspecified grade excluding the cost of centeringand shuttering - All work up to plinth level.1313 3.1.1M20 grade Nominal Mix1:1.5: 3(1 cement :1.5coarse sand : 3 graded stone aggregate 20mmnominal size).Cum 5,898.001314 3.1.2M15 grade Nominal Mix1:2: 4(1 cement : 2coarse sand : 4 graded stone aggregate 20mmnominal size).Cum 5,549.001315 3.1.3M15 grade Nominal Mix1:2: 4(1 cement : 2coarse sand : 4 graded stone aggregate 40mmnominal size).Cum 5,453.001316 3.1.4M10 grade Nominal Mix1:3: 6(1 cement : 3coarse sand : 6 graded stone aggregate 20mmnominal size).Cum 4,616.001317 3.1.5M10 grade Nominal Mix1:3: 6(1 cement : 3coarse sand : 6 graded stone aggregate 40mmnominal size).Cum 4,477.001318 3.1.61:4:8(1 cement : 4 coarse sand : 8 graded stoneaggregate 40 mm nominal size).Cum 3,962.001319 3.1.71:5:10(1 cement : 5 coarse sand : 10 gradedstone aggregate 40mm nominal size).Cum 3,547.001320 4.1Providing and laying in position specified gradeof cement concrete for all RCC structuralelements upto plinth level including curing,compaction, finishing with rendering in cementsand mortar1:3(1 cement: 3 coarse sand) andmaking good the joints and cost of plastizers( ifrequired) excluding the cost of centering,shuttering and reinforcement.M20 gradeNominal Mix / Design MixCum 5,921.001321 4.2Providing and laying in position specified gradeof cement concrete for RCC structural elementsupto floor five level including curing, compaction,finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making goodthe joints and cost of plastizers(if required)excluding the cost of centering, shuttering andreinforcement for Walls(any thickness) includingattached pilasters, buttresses, plinth and stringcourses, fillets, columns, pillars, piers,abutments, posts and struts etc.M20 gradeNominal Mix / Design MixCum 6,731.001322 4.3Providing and laying in position specified gradeof cement concrete for RCC structural elementsupto floor five level including curing, compaction,finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making goodthe joints and cost of plastizers( if required)excluding the cost of centering, shuttering andreinforcement for Beams, suspended floors,roofs, griders having slopes up to 15º, landings,balconies, shelves, chajjas, lintels, bands, plainwindows sills, staircases and spiral staircasesetc.M20 grade Nominal Mix / Design MixCum 6,222.001323 4.4Providing and laying in position specified gradeof cement concrete for RCC structural elementsupto floor five level including curing, compaction,finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making goodthe joints and cost of plastizers( if required)excluding the cost of centering, shuttering andreinforcement for Arches, arch ribs, domes,vaults, shells, folded plate, chimneys, shafts ,roofs having slope more than 15º,vertical andhorizontal fins individually or forming box louvers,facias and eaves boards M20 grade Nominal Mix/ Design MixCum 6,673.001324 4.5Providing and laying in position Ready mixconcrete manufactured in fully automaticBatching Plant and transported to site in transitmixer for having continous agitated mixer,manufactured as per approved mix design ofspecified grade of RCC work including pumpingof R.M.C. from transit mixer to site of laying ,exculding the cost of centering, shuttering andreinforcement with all lead and lift including costof admixtures in recommended portion as per IS9103 to accelerate/ retard setting of concrete,improve workability without impairing strengthand durability as per direction of Engineer incharge . All works upto floor V floorM20 gradeDesign Mix by using cement as per codalprovision.Cum 7,307.001325 4.6 Add extra for providing richer mixes respectivelyat all floor levels1326 4.6.1Providing M-25 grade concrete by using cementas per codal provision instead of M-20 gradedesign mix.Cum 76.001327 4.6.2Providing M-30 grade concrete by using cementas per codal provision instead of M-20 gradedesign mix.Cum 139.001328 4.7Add extra for RCC work in superstructure abovefloor five level for each four floor or part thereof . Cum 123.001329 4.8Deduct for using less cement quantity than thequantity as provided in the item of design mixconcrete/RMC as arrived as per mix design.(oncement quantity)Kg 8.001330 4.9Centering and Shuttering with plywood or steelsheets including strutting, propping bracing bothways and removal of formwork for foundation ,footings, strap beam, raft , bases of columns etc.Sqm. 173.001331 4.10Centering & shuttering with plywood or steelsheets including strutting, propping bracing bothways with steel props and removal of formworkfor upto floor five level for :1332 4.10.1 Walls (any thickness) including attachedpilasters, buttresses plinth and string course. Sqm 318.001333 4.10.2Suspended floors, roofs, landings, staircases,balconies, girders, cantilevers, bands, copingbed plates, anchor blocks, sills, chhajjas, lintel,beam, plinth beam etc.Sqm 374.001334 4.10.3 Columns, pillars, posts and struts etc. Sqm. 413.001335 4.10.8Add extra for shuttering in circular work(inrespective centering Sqm 20% and shutteringitems)1336 4.11Add extra for additional height in centring,shuttering where ever required with adequatebracing, propping etc. including cost of deshuttering and decentring at all levels, over aheight of3.5m, for every additional height of 1metre or part thereof(Plan are is to be measured)Sqm 188.001337 4.12Add extra for centering and shuttering work insuperstructure above floor five level for each fourfloor or part thereof .Sqm. 37.001338 4.13Providing and fabricating reinforcement forR.C.C. work including straightening, cutting,bending, placing in position and binding(including cost of binding wire) all complete up tofloor five level.1339 4.13.1 Cold twisted deformed bars(IS : 1786). Kg. 82.001340 4.13.2 Hot rolled deformed bars(IS : 1139). Kg. 82.001341 4.14Labour charges for cutting, bending forfabrication and binding reinforcement (plain ortor/ribbed/TMT steel) as per drawing and designfor R.C.C. and R.B. work including cost ofbinding wire with all lead and lift up to floor fivelevel complete.Kg. 13.001342 4.15Add extra for reinforcement in superstructureabove floor five level for each four floor or partthereof .Kg 3.001343 4.24Providing,arranging and erecting 50mm dia M.S.pipe cup lock shuttering arrangement above theground level upto the height given below. Thegirding arrangement of cup lock system shouldhave2.50 meter3.00 meter long coupling pipesand0.90mt long lacer pipe(Horizontal bracingpipes) reconnected in both ways so as to make asquare grid of size0.90x0.90 meter in plan. TheHorizontal bracing and lacer pipes should have amaximum spacing of1.50 meter c/c both ways.The bottom of the coupling pipe must rest over afirm support at ground. the shuttering plates of900mmx600mm size duly braced by anglesupports and should rest over 50mmx50mm sizewooden logs supported by 75x40x6mm sizechannels and U-Jacks made of M.S.25mm diasteel bars with adjustable thread and lockarrangement placed at a spacing of0.60 meterc/c. The whole arrangement should be dulyshored from ground by U-Jacks and lacer pipesto prevent any lateral movement during casting ofslabs. Additional support as per direction ofengineer in charge are also to by providedwherever felt necessary. The work would includetransportation of material erecting the whole gridstructure, bracing both way, shoring, leveling ofshuttering and removal of form work complete asper direction of Engineer in charge for all thefloors upto the height of:-(a) Upto6.63 meterSqm. 958.001344 4.25Rebarring work in old R.C.C structures includingmaking bore hole to adjust required bar diameterand filling a good quality filler to provide a tensilstrength as per requirement and fix the Bar to thesaction including cost of bars.(i) 8 mm bar(ii) 10mm bar Each 515.00(iii) 12 mm bar Each 581.00(iv) 16 mm bar Each 914.00(v) 20 mm bar Each1186.00(vi) 25 mm bar Each 1715.00Each 472.001345 5.2Brick work with F.P.S. bricks of class designation75 in superstructure above plinth level upto floorV level in all shapes and sizes in:1346 5.2.1 Cement mortar 1 : 4(1 cement : 4 coarse sand)Cum. 6,235.001347 5.2.2 Cement mortar 1 : 6(1 cement : 6 coarse sand)Cum. 5,988.001348 5.3 Add extra for Square or Rectangular Pillars inSuperstructre brick work up to five storey1349 5.3.1 Upto 45 cm length and all sides are free Cum 360.001350 5.3.2 Upto 45 cm length and two corners are free Cum 179.001351 5.3.3 Upto 90 cm length and all sides are free Cum 306.001352 5.7 Half brick masonry in foundation & plinth usingbricks of designation 751353 5.7.1 Cement mortar 1 : 3(1 cement : 3 coarse sand)Sqm. 630.001354 5.7.2 Cement mortar 1 : 4(1 cement : 4 coarse sand)Sqm. 596.401355 5.7.3 Cement mortar 1 : 6(1 cement : 6 coarse sand)Sqm. 564.001356 5.8Half brick masonry in Superstructure , aboveplinth level upto floor V level using bricks ofdesignation 751357 5.8.1 Cement mortar 1 : 3(1 cement : 3 coarse sand)Sqm. 700.001358 5.8.2 Cement mortar 1 : 4(1 cement : 4 coarse sand)Sqm. 664.001359 5.8.3 Cement mortar 1 : 6(1 cement : 6 coarse sand)Sqm. 631.001360 5.9Add extra providing and placing in position 2Nos.,6mm Ø M.S. bar at every third course ofhalf brick masonry .Sqm 64.001361 5.10Brick work in partition in super structure upto fivestorey7cm. thick(brick on edges) using bricks ofclass designation 75 in:1362 5.10.1 Cement mortar 1 : 3(1 cement : 3 coarse sand)Sqm. 475.001363 5.10.2 Cement mortar 1 : 4(1 cement : 4 coarse sand)Sqm. 452.001364 5.14Brick work in super structure upto five storey withselected bricks of class designation 75 inexposed brick work including making horizontaland vertical grooves 10mm. wide 12mm. deepcomplete in cement mortar1:6.Cum 6,066.001365 5.15Brick work with clay flyash F.P.S. brick(IS 13757- 1993) of class designation 75 in superstructureabove plinth level upto floor five level in:1366 5.15.1 Cement mortar 1 : 4(1 cement : 4 coarse sand)Cum 6,045.001367 5.15.2 Cement mortar 1 : 6(1 cement : 6 coarse sand)Cum 5,798.001368 5.16Brick work with mechanised autoclaved flyashlime bricks conforming to IS: 12894:2002 ofclass designation 100 in superstructure aboveplinth level upto floor V level in.1369 5.16.1 Cement mortar 1 : 4(1 cement : 4 coarse sand)Cum 5,894.001370 5.16.2 Cement mortar 1 : 6(1 cement : 6 coarse sand)Cum 5,574.001371 5.17Add extra for brick work in superstructure abovefloor five level, for each four floors or part thereof.1372 5.17.1 Quantity in Cum. Cum. 286.001373 5.17.2 Quantity in Sqm. Sqm. 25.001374 5.18Add extra over item of brick work with classdesignation 100 in substitution of classdesignation 75 : 1375 5.18.1 Quantity in Cum. Cum. 179.001376 5.18.2 Quantity in Sqm. Sqm. 21.001377 5.19Half Brick work with mechanised autoclavedflyash lime bricks conforming to IS: 12894:2002of class designation 100 in superstructure aboveplinth level upto floor V level in.1378 5.19.1 Cement mortar 1 : 4(1 cement : 4 coarse sand)Sqm 703.001379 5.19.2 Cement mortar 1 : 6(1 cement : 6 coarse sand)Sqm 668.001380 5.20Half Brick work with mechanised autoclavedflyash lime bricks conforming to IS: 12894:2002of class designation 75 in superstructure aboveplinth level upto floor V level in.1381 5.20.1 Cement mortar 1 : 4(1 cement : 4 coarse sand)Sqm 677.001382 5.20.2 Cement mortar 1 : 6(1 cement : 6 coarse sand)Sqm 643.001383 6.1Random Rubble stone masonry for with hardstone in foundation and plinth in Cement Sandmortar above 30 CM thick wall in:1384 6.1.6 Cement Mortar1:6(1-Cement :6-Sand). Cum. 3,406.001385 7.12Providing and fixing1st quality standard white,grey, ivory, fume red brown, light green, light blueand other light shades glazed tiles confirming toIS : 13753 & IS :15622 of size 200mm x 300mmin walls, floors, steps, pillars etc. laid on a bed ofneat cement slurry finished with flush pointing inthe white cement mixed with pigment to matchthe shade of the tile complete(excluding the costof cement plaster on walls and pillar).Sqm. 741.001386 7.13Providing and fixing1st quality MAT finishedceremic tile size 300x300mm confirming to IS :13755 and IS : 15622 colour such as white, grey,ivory, fume red brown, light green, light blue andother light shades in floors, steps, pillars etc. laidon a bed of neat cement slurry finished with flushpointing in the white cement mixed with pigmentto match the shade of the tile complete(includingthe cost of cement mortar bed1:4).Sqm. 823.001387 7.12Providing and fixing1st quality standard white,grey, ivory, fume red brown, light green, light blueand other light shades glazed tiles confirming toIS : 13753 & IS :15622 of size 200mm x 300mmin walls, floors, steps, pillars etc. laid on a bed ofneat cement slurry finished with flush pointing inthe white cement mixed with pigment to matchthe shade of the tile complete(excluding the costof cement plaster on walls and pillar).Sqm. 741.001388 7.13Providing and fixing1st quality MAT finishedceremic tile size 300x300mm confirming to IS :13755 and IS : 15622 colour such as white, grey,ivory, fume red brown, light green, light blue andother light shades in floors, steps, pillars etc. laidon a bed of neat cement slurry finished with flushpointing in the white cement mixed with pigmentto match the shade of the tile complete(includingthe cost of cement mortar bed1:4).Sqm. 823.001389 9.1Structural steel work in single section fixed withor without connecting plate including cutting,hoisting( height upto 10m), fixing in position andapplying a priming coat of approved steel primerall complete.Kg. 83.001390 9.1.1 Add Extra if I/rail section is used Kg. 10%1391 9.2Structural steel work riveted, bolted or welded inbuilt up sections, trusses and framed work,including cutting, hoisting(height upto 10m) ,fixing in position and applying a priming coat ofapproved steel primer all complete:Kg. 93.001392 9.3Steel work in built up tubular trusses includingcutting, hoisting(height upto 10m) fixing inposition and applying a priming coat of approvedsteel primer, welded and bolted including specialshaped washers etc. complete.1393 9.3.1 Hot finished welded type tubes. Kg. 110.001394 9.3.2 Hot finished seamless type tubes. Kg 120.001395 9.3.3 Electric resistance or induction butt welded tubes. Kg. 144.001396 9.4 Extra for hoisting and fixing for every additionalone metre or part thereof beyond 10 mtr height.Kg. 7.001397 9.5Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mmlugs 10cm long embedded in cement concreteblocks 15x10x10 cm of1:3:6(1 cement : 3coarse sand : 6 graded stone aggregate 20 mmnominal size) or with wooden plugs and screwsor rawl plugs and screws or with fixing clips orwith bolts and nuts as require including fixing ofnecessary butt hinges and screws and applying apriming coat of approved steel primer.Kg. 95.001398 9.6Providing and fixing pressed steel door framesconfirming to IS 4351 manufactured fromcommercial mild steel sheet of1.25 mmthickness including hinges jamb, lock jamb, beadand if required angle threshold of mild steel angleof section 50x25mm, or base ties of1.25mmpressed mild steel welded or rigidly fixed togetherby mechanical means, adjustable lugs with splitend tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plateand shock absorbers as specified and applying acoat of approved steel primer after pre-treatmentof the surface including filling with CC1:2:4(M15grade) complete as directed by Engineer- in-charge : 1399 9.6.1 Profile B Mtr. 472.001400 9.6.2 Profile C Mtr. 516.001401 9.6.3 Profile E Mtr. 557.001402 9.7Supply and fixing in cement mortar welded handrailing made out of MS round or square bars,flats etc. for staircase or verandah as per designcomplete in all respect (wooden or PVC handrailing to be paid extra) with priming coat of redoxide.Kg. 89.001403 9.7.1 Extra for providing D type pipe head as top ofhand railing Kg. 10%1404 9.8Providing and fixing steel gate, grating , and grillsmade of angles, tees, square bars, flats,or blackpipe with holdfast and fittings complete as perdesign and drawing including cutting welding andfabrication with priming coat of red oxideKg. 106.001405 9.8.1Extra if square,rectangular hollow tubelarsections are used or grill Kg. 10% made by flatsonly1406 9.9Providing and fixing cow catcher made of R.S.joist angles channels MS rounds including cuttingwelding and fabrication with priming coat of redoxide (as per design).Kg. 81.001407 9.10Providing and fixing in position collapsible steelshutters with Sqm. vertical M.S. Channels 20 x10 x2mm and bracket with flat iron diagonals 20x5mm. size with top and bottom rail of T-iron 40x 40 x6mm. with 40mm dia steel pulleys/ballbearing complete with bolts, nuts lockingarrangements inside and outside stoppers,handles etc. as per specification includingapplying a priming coat of approved steel primer. (To be measured and paid as per outerdimension).5,691.001408 9.11Providing and fixing1mm thick M.S. sheet sliding-shutters with frame & diagonals braces of 40 x 40x6mm. angle iron3mm M.S. gusset plates at thejunction and corners, 25mm dia pulley40x40x6mm angle and T-iron guide at the topand bottom respectively including applying apriming coat of approved steel primer.Sqm 3,937.001409 9.12Providing and fixing1mm thick M.S. sheetgarrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at thejunction and corners including all fittings andapplying a coat of approved steel primer : (Excluding cost of frames) 9.12.1 Using M.S.angles 40 x 40 x6mm for diagonal braces.9.12.2Using flats 30 x6mm for diagonal braces andcentral cross piece. Sqm. 3292.00Sqm. 3,455.001410 9.13Supplying and fixing rolling shutters of approvedmake, made of 80 Sqm. x1.25mm.M.S. lathsinterlocked together through their entire lengthand jointed together at the end by end locksmounted on specially designed pipe shaft withbrackets, side guides and arrangements forinside and outside locking with push and pulloperation complete including cost of springhooks, providing and fixing necessary 25.3cm.long wire springs grade No. 2 and M.S. top cover1.25mm thick for rolling shutters as per design &IS 6248- 1979.(Clear openable area to bemeasured for payment).2,281.001411 9.14 Providing & fixing ball bearing for rolling shutters Each 568.001412 9.15Extra for providing mechanical device chain andcrank operation for operating rolling shutters. 9.15.1 Exceeding 10.00 Sqm and upto 16.80Sqm in the area.9.15.2 Exceeding 16.80 Sqm inthe area. Sqm. 976.00 9.16 Extra for providinggrilled rolling shutters manufactured out of 8Sqm. 360.00 mm dia.M.S. bar instead of laths asper design approved by Engineer-in-charge.(area of grill to be measured).Sqm. 905.001413 9.17Providing and fixing M.S. sheet1mm thick singleleaf door shutter Sqm. in angle iron frame35x35x5mm suitabilly diagonally braced with25x3mm flat iron above and below lock rail ofsize 50x5mm beading extra including all fittings,as per direction of Engg. incharge but excludingcost of chowkhats: including two coats of anit-corrosive red oxide primer paint9.17.1 Extra fordouble leaf shutters. Sqm. 20%3,156.001414 9.18Fixing standard steel glazed doors, windows andventilators in walls Sqm. with 15x3mm lugs 10cmlong embedded in cement concrete blocks15x10x10 cm of1:3:6(1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size)or with wooden plugs and screws or rawl plugsand screws or with fixing clips or with bolts andnuts as required, including fixing of glass paneswith glazing clips and special metal-sash putty ofapproved make, or metal beading with screws (only steel windows with lugs, glass pane cut tosize and glazing clips or metal beading withscrews, shall be supplied by department free ofcost.)306.001415 9.19Providing and fixing steel glazed doors windowsand ventilator shutters of standard rolled steelsection(IS 1038-1983) joints mitred and weldedwith steel lugs 13x3mm, 10cm. long embedded incement concrete block 15x10x10cm. of1:3:6(1cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size) or with woodenplugs and screws or rawl plugs and screws withfixing clips or with bolts and nuts as requiredincluding providing and fixing of plain glasspanes4mm thick with cooper glazing clips andspecial metal sash putty of approved make ormetal beading with screws complete includingpriming coat of approval steel primer, excludingthe cost of metal beading and other fitting exceptnecessary hinges of pivots steel handles pegstay etc. as required:1416 9.19.1 Doors Sqm. 3,409.001417 9.19.2 Windows fixed Sqm. 3,399.001418 9.19.3 Windows side hung /Ventilators top or centrehung (openable) Sqm. 3,449.001419 9.19.4 Partly fixed and partly openable[ fixed area notto exceed 33%]Sqm. 3,399.001420 9.20 Providing brass handles/peg stays and fittings inplace of oxidized Sqm.5% fitting1421 9.21 Aluminium handles/peg stays fitting instead ofoxidized fitting. Sqm.3%1422 9.225mm thick plain glass instead of4mm thick plainglass Sqm. 105.001423 9.23 Deduct for Not providing glass panels Sqm. 342.001424 9.24Deduct for Pin headed4mm thick glass panels isused instead of Sqm.5%4mm thick plain glass1425 9.25 Deduct for Not provided oxidised fittings. Sqm. 5%1426 9.26Supplying and fixing fixed wire gauge of 14 meshx 24 gauge to the Sqm. metal frame of rolledsection by metal beading 20x3mm with suitablescrew at not exceeding 150mm distance.679.001427 9.27 Providing and fixing Square bars or other flatwelded to window, ventilatiors etc. Kg. 72.001428 9.28Providing and fixing steel glazed window framemade out of 80x40 mm hollow sheet section of16 gauge thickness, joint mitred welded andgrinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C C block 15x 10 x 10 Cm of1:3:6 nominal concrete andincluding fixing of pivoted hinges of superiorquality, window shutters made out of 50 x 25.0mm hollow steel section 15 mm paitam of 18gauge thickness, joint mitred and grindedincluding 10mm x 10mm square bars welded toframe for paitam fixing float glass4mm thickpanes with glazing clips and metal sash puttyand fixing of shutters frames peg stay, U shapehandle 100 mm long, tower bolts 100 mm long ofsteel powder coated superior quality includingfixing and jointing with frame hinges priming coatwith steel primer complete in all respect as perdirection of Engineer-in–charge9.28.1 Windowopenable.9.28.2 Window fixed. Sqm 3851.009.28.3 Extra for additional shutter in pipe sectionwindows with wire gauge Sqm 1819.00 14 meshx 24 gaugeSqm 4,183.001429 9.29180cm high fencing with angle iron post55x55x6mm. placed at every3Mtr. apart 45cm. inground embedded in cement concrete1:3:6(30x30x60cm) corner and every tenth post to bestrutted with 55x55x6mm. angle iron providedwith 6 horizontal lines and two diagonals of blackbarbed wire between two posts fitted and fixedwith G.I. staples including earth work inexcavation etc. complete.Mtr. 645.001430 9.30150 cm high fencing of precast R.C. posts of15cmx15cm tapered to 10x10cm at top placed atevery3m apart 30cm in ground embedded incement concrete1:3:6(30x30x45cm) corner andevery tenth posts to be strutted with same R.C.posts provided with 6 horizontal lines and twodiagonals of black barbed wire between the twoposts fitted and fixed with G.I. staples includingearth work in excavation etc. completeMtr. 553.001431 9.31150cm high fencing with angle iron 50x50x6mm.placed at every3Mtr. apart 30cm. in groundembedded in cement concrete1:3:6(30x30x45cm) corner and every tenth post to bestrutted with 50x50x6mm. angle iron providedwith 5 horizontal lines and two diagonals of blackbarbed wire between two posts fitted and fixedwith G.I. staples including earth work inexcavation etc. complete.Mtr. 563.001432 9.32120cm. high fencing with angle iron posts50x50x6mm. placed at every 3 Mtr. apart 30cm.in ground embedded in cement concrete1:3:6(30x30x45cm) corner & every tenth posts to bestrutted with 50x50x6mm angle iron provided withfour horizontal lines and two diagonals of blackbarbed wire between two posts fitted and fixedwith G.I. staple including earth work in excavationetc. complete.Mtr. 517.001433 9.33 Add or deduct for each wire line over basic item Mtr. 13.001434 9.34 Add or deduct for additional or less higher per 10Cm. over basic Mtr5% item1435 9.35Extra for using galvanized barbed wire instead ofblack barbed wire. Mtr.5% Each wire9.35.1 AddExtra if barbed wire fencing is done on wall uptoheight of Mtr.5%3.00 Mtr.1436 9.36Supplying and fixing of chain link fencing withangle iron posts 50x50x6mm placed at every 3Mtr. apart 30cm in ground embedded in cementconcrete1:3:6(30x30x45cm) corner and everytenth post to be strutted with(50 x 50 x6cm)angle iron provided and fixed and fitted withposts including earth work in excavation etc.complete with chain link size.1437 9.36.1 50mm x 50mm x3.15mm Sqm. 692.001438 9.36.2 75mm x 15mm x3.15mm Sqm. 622.001439 9.36.3 100mm x 100mm x3.15mm Sqm. 573.001440 9.36.4 150mm x 150mm x3.15mm Sqm. 528.001441 9.37Providing and fixing concertina coil fencing withrequired dia 610 mm(having 15 nos. round per 6metre length) up to3m height of wall with existingangle ironY shaped placed2.4 m or3.00 mapart and with 9 horizontal R.B.T. stud tied withGI staples and GI clips to retain horizontalincluding necessary bolts or GI barbed wire tiedto angle iron all complete as per direction ofEngineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of hightensile strength of 165 kg/sq.mm with tape(0.52mm thick) and weight 43.478 gm/metre(Cost ofMS angle, CC block shall be paid extra)Mtr. 293.001442 9.39Providing and fixing of double leaf steel shutterfor cupboard, the frame is made of pressed steelISI section 80x25 mmx1.25 mm thick with1.00mm MS sheet to spot welded including holdfastsof 15x3mm, MS oxidized fittings such as butthinges, sliding doors bolts, handles, tower bolts,lock and twin peg etc complete including applyingpriming coat of approved steel primer of redoxide zinc chromate and spray painting inapproved shade with deco paint of approvedquality complete as per direction of Engineer InChargeSqm 4,285.001443 10.17Grading roof for water proofing treatment withwater proffing compound 10.17.1 Cementconcrete1:2:4(1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size)10.17.2 Cement mortar1:3(1 cement : 3 coarsesand) Cum 6425.00 10.17.3 Cement mortar1:4(1cement : 4 coarse sand) Cum 5348.00Cum 4,931.001444 10.18Providing and laying brick kharanja on roofs withcement mortar1:4(1 cement : 4 coarse sand)mixed with2% integral water proofing compoundin square pattern 10.18.1 75mm to 100mm thickaverage 10.18.2 55mm to 60mm thick averageSqm 276.00Sqm 305.001445 10.19Providing and laying brick tiles of classdesignation 100 over roofs grouted with cementmortar1:3(1 cement : 3 fine sand) mixed with2% of integral water proofing compound byweight of cement, over a 12 mm layer of cementmortar1:3( 1 cement : 3 fine sand) and finishedneat .Sqm 394.001446 10.20Providing and fixing 20 mm thick precast terrazotiles of approved make, with marble chips of sizeupto6mm laid over roof with neat cement slurrymixed with pigment to match the shade of thetiles, including cutting,grinding rubbing withmachine complete on 20 mm thick bed of cementsand mortar 1 :4.Sqm 385.001447 10.21Providing and laying integral cement based waterproofing treatment including preparation ofsurface as required for treatment of roofs,balconies, terraces etc consisting of followingoperations.(a) Applying and grouting a slurrycoat of neat cement using2.75 kg/sqm. ofcement admixed with proprietary water proofingcompound conforming to IS. 2645 over the RCCslab including cleaning the surface beforetreatment.(b) Laying cement concrete usingbroken bricks/brick bats 25 mm to 100mm sizewith 50% of cement mortar1:4(1 cement : 4coarse sand) admixed with proprietary waterproofing compound conforming to IS : 2645 over20 mm thick layer of cement mortar of mix1:4(1cement :4 coarse sand) admixed with proprietarywater proofing compound conforming to IS : 2645to required slope and treating similarly theadjoining walls upto 300 mm height includingrounding of junctions of walls and slabs.(c) Aftertwo days of proper curing applying a second coatof cement slurry admixed with proprietary waterproofing compound conforming to IS : 2645.(d)Finishing the surface with 20 mm thick jointlesscement mortar of mix1:4(1 cement:4 coarsesand) admixed with proprietary water proofingcompound conforming to IS : 2645 and finallyfinishing the surface with trowel with neat cementslurry and making of 300x300xmm square(e)Sqm 520.001448 10.22Providing gola 75x75 mm in cement concrete1:2:4(1 cement : 2 coarse sand : 4 stoneaggregate 10mm and down gauge) includingfinishing with cement mortar1:3(1 cement : 3fine sand) as per standard design:Mtr. 122.001449 10.23Making khurras 450 x 450mm with averageminimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micronfinished with 12mm cement plaster 1 : 3 and onecoat of neat cement, rounding edges and makingand finishing the out let complete.Each 169.001450 10.24Providing & laying broken glazed titles on roof (broken glazed tiles not less than 9 Kg/Sqm) ontop of hot bitumen @1.7 Kg/Sqm.(1.40 Kg ofVG-40(30/40)grade and0.30 Kg/Sqm. of VG-10(80/100) grade) and joints filled with cementmortar 1 :2(1 cement:2 marble dust mixed withwater proofing compund all complete as perdirection of Engineer-in-charge.Sqm 349.001451 11.12Crazy marble stone flooring 20mm thick marblestone with black or of specified colour toppingincluding filling the gaps with cement marblechips mix in proportion of 4 : 7(4cement : 7 whiteblack or white or black marble chips) size from1mm to4mm by volume and under layer of25mm thick cement concrete[1:2:4, gradedstone aggregate 12.5mm nominal size] rubbingand polishing and cement slurry etc. complete :In ordinary cement.Sqm 637.001452 11.13Precast terrazo tiles of approved make, 20mmthick with marble chips of size upto6mm laid infloors, and landing, jointed with neat cementslurry mixed with pigment to match the shade ofthe tiles, including rubbing and polishingcomplete on 20mm thick bed of cement sandmortar 1 :4. 1453 11.13.1 Light shade using white cement. Sqm 596.001454 11.13.2 Medium shade using approximately 50% whitecement and 50% ordinary cement.Sqm 604.001455 11.13.3 Dark shade using ordinary cement. Sqm 520.001456 11.13.4 Ordinary cement without any pigment. Sqm 587.001457 11.14 Extra if terrazo tiles are laid in treads of steps notexceeding 30 cm in width.Sqm 35.001458 11.15Precast terrazzo tiles of approved make 20mmthick with marble chips of size upto6mm inskirting & risers, treads of steps and dados12mm thick cement plaster1:3(1 cement : 3coarse sand) jointed with neat cement slurrymixed with pigment to match the shade of thetiles, including rubbing and polishing completewith tiles of : 1459 11.15.1 Light shade using white cement. Sqm 759.001460 11.15.2 Medium shade using approximately 50% whitecement and 50% ordinary cement.Sqm 749.001461 11.15.3 Dark shade using ordinary cement. Sqm 739.001462 11.15.4 Ordinary cement without any pigment. Sqm 750.001463 11.16Providing & laying Chequered terrazzo tiles ofapproved make 22mm thick with marble chips ofsize upto6mm, in floors, jointed with neat cementslurry mixed wit pigment to match the shade oftiles including rubbing and polishing complete inall respect as per specification, on 28mm thickbed of C.M.1:4 : 1464 11.16.1 Light shade using shade cement. Sqm 752.001465 11.16.2 Medium shade using approximately 50% whitecement and 50% ordinary cement.Sqm 751.001466 11.16.3 Dark shade using ordinary cement. Sqm 680.001467 11.16.4 Ordinary cement without any pigment. Sqm 626.001468 11.17Chequerred precast cement concrete tiles 22 mmthick in footpath & courtyard jointed with neatcement slurry mixed with pigment to match theshade of tiles including rubbing and cleaning etc.complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand)1469 11.17.1 Light shade using shade cement. Sqm 628.001470 11.17.3 Dark shade using ordinary cement. Sqm 575.001471 11.17.4 Ordinary cement without any pigment. Sqm 520.001472 11.17.5Add Extra for polished chequered precastcement concrete tiles 10% over item No. 11.17.1,11.17.2, 11.17.3, 11.17.41473 11.18Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed withgrey cement slurry mixed with pigment to matchthe shade of the slab including rubbing andpolishing complete with base of cement mortar 1: 4(1 cement : 4 coarse sand)1474 11.18.1 For area of each slab from 901 to 2000 Sq.Cm: Sqm 1,140.001475 11.18.2 For area of each slab from 2001 to 5000 Sq.Cm Sqm 1,228.001476 11.19Kota stone slabs 25 mm thick in risers of steps,skirting, dado and pillars laid on 12 mm(average)thick cement mortar1:3(1 cement 3 coarsesand) and jointed with grey cement slurry mixedwith pigment to match the shade of the slabs,including rubbing and polishing complete1477 11.19.1 For area of each slab upto 2001 Sqcm Sqm 1,094.001478 11.19.2 For area of each slab from 2001 to 5000 Sqcm Sqm 1,202.001479 11.20Rough Chisel dressed Kota stone 35 mm thickflooring of approved shade set in pattern over20mm thick base of cement mortar1:6(1 cement: 6 coarse sand) and pointing with cement sandmortar1:3 with pigment to match the shade ofstone with joint thickness up to 15 mm completein all respects :Sqm 752.001480 11.22Fine dressed & machine cut edges 30-35 mmthicksand stone flooring over 20 mm(average)thick base of cement mortar1:4(1 cement : 4coarse sand) jointed grey cement slurry mixedwith pigment to match the shade of stonecomplete as per design drawing and instructionof EI. 1481 11.22.1 Red sand stone (Karauli stone) Sqm 928.001482 11.22.2 Pink sand stone (Bansi Paharpur stone) Sqm 1,060.001483 11.22.3 Mandana stone Sqm 1,060.001484 11.23Fine grinded Gangsaw cut 30-35 mm thick stoneflooring over 20 mm(average) thick base ofcement mortar1:4(1 cement:4 coarse sand)jointed grey cement slurry mixed with pigment tomatch the shade of stone complete as per designdrawing and instruction of EI.1485 11.23.1 Red sand stone (Karauli stone) Sqm 990.001486 11.23.2 Pink sand stone (Bansi Paharpur stone) Sqm 1,124.001487 11.23.3 Mandana stone Sqm 1,124.001488 11.24 Extra for pre finished nosing in treads of steps ofKota stone/ sand stone slab. Sqm 86.001489 11.25Extra for Mirror polishing on terrazzo/Kota stonework where ever required to give high glossfinish complete.Sqm 145.001490 11.26 Random rubble dry stone Kharanja under floor. Cum 1,118.001491 11.44Providing & Laying Tactile tile(for vision impairedpersons is standard of size 300x300x20mm andconfirming to IS 1231 of 1980(Re affirmed in2006) in all colours & sheds further productshould confirm ASTM 303 for shad resistanceand DIN51099 for colour fastness etc. laid on20mm thick base of cement mortar1:4(1 cement: 4 course sand) in all shapes & patternsincluding grouting the joint which white cementmixer) will matching pigments etc complete is perdirection of Engineer-in-charges. Grade M 30Sqm 1,412.001492 12.1Plaster on new surface on wall in cement sandmortar1:3 including racking of joints etc.complete fine finish:1493 12.1.2 20mm thick Sqm 253.001494 12.1.3 12mm thick Sqm 197.001495 12.2Plaster on new surface on walls in cement sandmortar1:4 including racking of joints etc.complete fine finish:1496 12.2.2 20mm thick . Sqm 242.001497 12.2.3 12mm thick . Sqm 196.001498 12.3Plaster on new surface on walls in cement sandmortar1:6 including racking of joint etc. completefine finish : 1499 12.3.2 20mm thick. Sqm 228.001500 12.3.3 12mm thick. Sqm 192.001501 12.4Plaster on new surface on walls in cement sandmortar1:8 including racking of joint etc. completefine finish : 1502 12.4.2 20mm thick. Sqm 197.001503 12.4.3 12mm thick. Sqm 168.001504 12.5 6 mm thick cement plaster to ceiling of mix1:3(1cement :3-fine sand)Sqm. 167.001505 12.9Rough cast plaster upto 10m height aboveground level with a mixture of sand and gravel orcrushed stone from6mm to 10mm nominal sizedashed over and including the fresh plaster intwo layers, under layer 12mm cement plaster1:4(1 cement : 4 coarse sand) and top layer 10mmcement plaster1:3(1 cement : 3 fine sand) mixedwith 10% finely grounded hydrated lime byvolume of cement. Ordinary cement finish usingordinary cementSqm 374.001506 12.10Pebble dash plaster upto 10m height aboveground level with a mixture of washed pebble orcrushed stone6mm to 12.5mm nominal sizedashed over and including fresh plaster in twolayers under layer 12mm cement plaster1:4(1cement : 4 coarse sand) and top layer 10mmcement plaster with cement mortar1:3(1 cement: 3 fine sand) with 10% finely grounded hydratedlime by volume of cementSqm 355.001507 12.11Washed stone grit plaster on exterior walls ofheight upto 10M. above level in two layers,under layer 12mm cement plaster1:4(1 cement :4 coarse sand) furrowing the under layer withscratching tool, applying cement slurry on theunder layer @2kg of cement per sqm, top layer15 mm cement plaster1:1/2:2( 1 cement :1/2coarse sand : 2 stone chipping size 10 mmnominal size) in panel with groove all around asper approved pattern including scrubbing andwashing, the top layer with brushes and water toexpose the stone chipping, complete as perspecification and direction of Engineer in charge. (Payment for providing grooves shall be madeseparately)Sqm 561.001508 13.1Repairs to plaster of thickness 12mm to 20mm inpatches of area2.5 sq. metres and underincluding cutting the patch in proper shape,raking out joints and preparing and plastering thesurface of the walls complete including disposalof rubbish to the dumping ground within 50 mlead : With cement mortar 1:4( 1 cement : 4coarse sand)Sqm 259.001509 13.2Fixing chowkhats in existing opening includingembedding chowkhats in floors or walls cuttingmasonry for holdfasts embedding hold fasts incement concrete blocks with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20 mm nominaal size)painting twocoats of coal tar to sides of chaukhats andmaking good the damages to walls and floors asrequired complete including disposal of rubbishto the dumping ground within 50 metres lead1510 13.2.1 Door chowkhats Each 677.001511 13.2.2 Window chowkhats Each 421.001512 13.3Making the opening in masonry includingdismantling in floor or walls by cutting masonryand making good the damages to walls, flooringand jambs complete to match existing surface i/cdisposal of mulba/rubbish to the nearestmunicipal dumping ground.Fordoor/windows/clerestory windowsSqm 492.001513 13.4 Renewing glass panes, with putty and nailswherever necessary:1514 13.4.1 Float glass panes of thickness 4 mm Sqm 679.001515 13.4.2 Float glass panes of thickness 5 mm Sqm 839.001516 13.5.14mm thick plain glass panes. Sqm 842.001517 13.5.25mm thick plain glass panes. Sqm 1,003.001518 13.6 Renewing glass panes and refixing existingwooden fillets :1519 13.6.14mm thick plain glass panes. Sqm 700.001520 13.6.25mm thick plain glass panes. Sqm 858.001521 13.8 Renewal of old putty of glass panes (length) Rm 20.001522 13.9 Refixing old glass panes with putty and nails Sqm 234.001523 13.10 Fixing old glass panes with wooden fillets(Excluding cost of fillets) Sqm 194.001524 13.11Providing and fixing 16 mm M.S. Fan clamps ofstandard shape and size in existing R.C.C. slabincluding cutting chase and making good andpainting exposed portion of the clamps complete.Each 237.001525 13.12 Repair to stone masonary in cement sand mortar 1:6 with old and new stone.Sqm 350.001526 13.13 Repair to brick masonary in cement sand mortar 1:6 with new brick.Sqm 389.001527 13.14Cement plaster1:3 under old stone slabs withadmixture(gur,nails,binding wire to mesh andscraping scales & dressing joints of slabscomplete. 1528 13.14.1 Proofing upto 25 mm thickness. Sqm 317.001529 13.14.2 Proofing above 25 mm thickness& upto 60 mmthickness Sqm 505.001530 13.15Patch repair to cement concrete floor includingdigging out old floor in regular shape andremoval of rubbish curing etc. complete in allrespects.Sqm 349.001531 13.18Replacing broken roofing slab in patchesincluding lime terrace, ceiling plaster etc.including removal of broken slabs.Sqm 2,028.001532 13.19 Making holes in stone masonry wall upto 450 mmx 450 mm size and making good in CM1:6.Each 200.001533 13.20 Grinding of existing floor with1534 13.22Providing and fixing double scaffolding system onthe exterior side, upto five story made with4wooden member1.5 m c/c horizontal and verticaldirection joining with rassi, clamps, challies. Thescaffolding system shall be stiffened withbracing, runner, connection of building ifnecessary with all essential safty features for theworkmen etc complete as per direction of EI.Thelavation area of the scaffolding shall bemeasured for payment. The payment will bemade once irrespective of duration ofscaffolding.Note : This item to be used formaintence work judicallySqm. 178.001535 13.23Repair of existing steel glazed doors, windowsand ventilator, MS sheet door, garge doors,compound wall gates etc. by welding drillingcomplete include. Cost of welding rods and hirecharge of welding meachine and TP etc completeSqm. 365.001536 13.24Labour charges for repair to door / windowwithout using any material such as applyingrandha (finishing) tightening of bolts & screw etc. Sqm. 242.001537 13.29Repair to damaged RCC slabs, beams andcolumns etc for strengtheing with cement mortar1 : 2 in following stepsi) Choping losse andcracked concrete to required depth, cleaning theexposed surface of steel and concrete with wirebrush and sand papering , cleaning of concretesurface with water as necessary and gettingdried.ii) Applying Epoxy primer on the exposedsteel bars.iii) Applying Epoxy hardener and resinmix(as per manufectureds specification) onconcrete and steel bars with brush.iv)Speadingdry cement mortar 1 : 2 mix over epoxy treatedwet surface and allow it to dry for one day.v)Plastering the surface with cement sand mortar 1: 3 upto depth of 30mm complete.vi) Cure theplastered surface for 15 days All work includingscaffolding etc. complete in all respect.Sqm 1,725.001538 13.30Replacement of stone Chajja with sriwan indamaged portion as per existing thickness andwidth in CM 1 : 3 with removal of old damagedpieces of chajja including top plaster of chajjaand bottom pointing in CM 1 : 3 with scoffoldingupto Ground floor level as per direction ofEngineer in chargeSqm 3,102.001539 13.30.1 Add Extra for each additional floor Sqm 290.001540 13.31Repair to damaged cement plaster of stonechajja with CM 1 : 3 of required thickness on top& bottom as per existing pattern and makingpatta etc complete up to three floor level as perdirection of Engineer in charge including allnecessary scoffolding etcSqm 696.001541 13.32Mechanised cleaning of storage tanks comprisesof following 6 stage as mentioned below:1.Mechanical dewatering2. Desalting removal ofleftover dirty water and sludge with sludge pump 3. Cleaning of wall, ceiling and floor by highpressure water jet with help of equipments whichcreates a pressure of 100-150 bar4. Removal ofremaing sludge from floor with the help ofindustrial vacuum cleaner.5. Spraying of nontoxic, bio degradable ecofriendly and bacterialagent certified by a govt approved laborary todisinfect the tank from all harmfull pathogens.The dose should be safe as per the UECDguidelines & 23 adopted on 17 th december2001.6. Treatment of inside tank by exposing UVradiation to kill further suspended or floatingbacteria if any1542 13.32.1 Upto 500 ltr. Ltr. 0.401543 13.32.2 Above 500 ltr. to 1000 Ltr. Ltr. 0.351544 13.32.3 Above 1000 ltr. Ltr. 0.301545 13.33Repair of door, window shutters including cost ofmaterial and labour for change of damaged :(a)Style / rail of teak wood 30mm thick/ AluminiumSection(i)4wide(ii)6 wide Rmt. 294.00(b)Panel by0.00(i) Shuttering Ply -9mm thick(Commercial) Sqm. 658.00(ii) Wire Gauge 14mesh x 24 gauge Sqm. 587.00(iii) Plain GlassPanes4mm thick Sqm. 474.00(c) Aldrop of mildSteel0.00(i) 12 long x12mm dia Each 162.00(ii)8 long x 10mm dia Each 117.00(d) Stopperof Aluminium with0.00(i) Single Rubber GutkaEach 36.00(ii) Double Rubber Gutka Each 52.00(e) Door Springs of mild Steel Each 176.00(f)Steel Hinges0.00(i) For Wooden Chowkhat3size. Each 26.00(ii) For Wooden Chowkhat4size Each 37.00(iii) For Stone Chowkhat,4sizeEach 32.00(g) Mild Steel Tower Bolt6 longEach 43.00(h) Steel Locking Bolt Each 58.00(i)Steel Handle6 size Each 26.00Rmt. 293.001546 13.34Making of hole in R.C.C. slab/wall/beams andmasonary wall(width up to 450 mm) by corecutting machine complete as per direction of EI1547 13.34.1 From diameter 100mm to 150mm Nos 1,218.001548 13.34.2 Diameter above 150mm Nos 1,829.001549 14.1Demolishing lime concrete manually/ bymechanical means and disposal of materialwithin 50 metres lead as per direction ofEngineer-in-charge.Cum 279.001550 14.2Demolishing cement concrete manually/ bymechanical means including disposal of materialwithin 50 metres lead as per direction ofEngineer-in-charge. 1551 14.2.11:3: 6 or richer mix. Cum 701.001552 14.2.21:4: 8 or leaner mix. Cum 432.001553 14.3Demolishing R.C.C. work manually/ bymechanical means including stacking of steelbars and disposal of unserviceable materialwithin 50 metres lead as per direction ofEngineer-in-charge.Cum 1,023.001554 14.4Demolishing R.B. work manually/ by mechanicalmeans including stacking of steel bars anddisposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge.Cum 915.001555 14.5Extra for cutting reinforcement bars manually/ bymechanical means in R.C.C. or R.B. work(Payment shall be made on the cross sectionalarea of R.C.C. or R.B. work) as per direction ofEngineer-in-chargeSqm 349.001556 14.6 Extra for scrapping, cleaning and straighteningreinforcement from R.C.C. or R.B. work Kg 2.001557 14.7Demolishing brick work manually/ by mechanicalmeans including stacking of serviceable materialand disposal of unserviceable material within 50metres lead as per direction of Engineer-in-charge. 1558 14.7.3 In cement mortar. Cum 592.001559 14.8Removing mortar from bricks and cleaning bricksincluding stacking within a lead of 50 meters (stacks of cleaned bricks shall be measured):1560 14.8.3 From brick work in cement mortar. Nos. 1000 2,039.001561 14.9Demolishing stone rubble masonry manually/ bymechanical means including stacking ofserviceable material and disposal ofunserviceable material within 50 metres lead asper direction of Engineer-in-charge:1562 14.9.2 In cement mortar. Cum 705.001563 14.10Dismantling dressed stone work ashlar facestone work, marble work or precast concretework manually/ by mechanical means includingstacking of serviceable and disposal ofunserviceable material within 50 metres lead asper direction of Engineer in charge:1564 14.10.2 In cement mortar. Cum 826.001565 14.11Removing mortar from stones and cleaningstones and concrete articles including stacking(net quantity of stacks of cleaned materials willbe measured):1566 14.11.2 Cement mortar. Cum 204.001567 14.12Dismantling doors, windows and clearstorywindows steel or wood shutter includingchowkhats and holdfasts etc. complete andstacking within 50 meters lead:1568 14.12.1 Of area 3 square meter and below. Each 116.001569 14.12.2 Of area exceeding 3 square meter. Each 158.001570 14.13Taking out doors, windows and clearstorywindows shutters(steel or wood) includingstacking within 50 meters lead: 14.13.1 Of area 3square meter and below. 14.13.2 Of areaexceeding 3 square meter. Each 61.00Each 46.001571 14.17Dismantling steel work in single sectionsincluding dismembering and stacking within 50meters lead in: 14.17.1R.S. joists. 14.17.2Channels, angles, tees & flats. Kg1.00Kg 1.001572 14.18Dismantling steel work in built up sections inangles, tees, flats and channels including allgusset plates, bolts, nuts, cutting rivets, weldingetc. including dismembering and stacking within50metres lead.Kg 2.001573 14.19Dismantling steel work manually/ by mechanicalmeans in built up sections without dismemberingand stacking within 50 metres lead as perdirection of Engineer-in-charge.Kg 1.001574 14.23Dismantling tile work in floors and roofs laid incement mortar including stacking of serviceablematerial and disposal of unserviceable materialwithin 50 meter lead: 14.23.1 For thickness oftiles 10mm to 25mm. 14.23.2 For thickness oftiles 25mm to 40mm. Sqm 37.00Sqm 22.001575 14.24Dismantling dry brick pitching in floors drains etc.including stacking of serviceable material anddisposal of unserviceable material within 50meters lead.Cum 377.001576 14.25Dismantling stone slab/ terrazo chip flooring laidin cement mortar including stacking ofserviceable material and disposal ofunserviceable material within 50 meters lead.Sqm 88.001577 14.26Dismantling brick tiles covering in terracingincluding stacking of serviceable material anddisposal of unserviceable material within 50meters lead.Sqm 37.001578 14.40Dismantling precast concrete or stone slabs inwall partitions etc. including stacking within 50meter lead: 14.40.1 Thickness up to 40mm.14.40.2 Thickness 40mm up to 75mm Sqm129.00Sqm 85.001579 14.41Dismantling CI or asbestos rain water pipe withfitting and clamps including stacking within 50meter lead: 14.41.1 Up to 80mm dia pipe.14.41.2 100mm dia pipe. Mtr. 21.00 14.41.3150mm dia pipe. Mtr. 22.00Mtr. 21.001580 14.42Dismantling tar felt over roofing completeincluding stacking of serviceable material anddisposal of unserviceable material within 50-meter lead.Sqm 25.001581 14.43Dismantling GI pipes(external work) includingexcavation and refilling trenches after taking outthe pipes and including stacking of pipes within50 meter lead: 14.43.1 15mm to 40mm nominalbore. 14.43.2 Above 40mm nominal bore. Mtr.52.00Mtr. 45.001582 14.44Dismantling CI pipes including excavation andrefilling trenches after taking out the pipes,breaking lead caulked joints, melting of lead andmaking into block, including stacking of pipeslead at site within 50 meter, of dia: 14.44.1 Up to150mm dia. 14.44.2 Above 150mm dia. up to300mm dia. Mtr. 162.00 14.44.3 Above 300mmdia. Mtr. 217.00Mtr. 120.001583 14.45Dismantling steel cylinder,R.C. pipes etc.including excavation and refilling trenches aftertaking out the pipes, breaking lead caulked joints,melting of lead and making into blocks includingstacking of pipes, within a lead of 50 meter, ofdia: 14.45.1 Up to 600mm dia. 14.45.2 Above600 mm dia. Mtr. 547.00Mtr. 217.001584 14.46Dismantling asbestos cement pressure pipesincluding excavation and refilling trenches aftertaking out the pipes, and stacking the samewithin a lead of 50 meter, of dia: 14.46.1 Up to150mm. 14.46.2 Above 150mm. Mtr. 116.00Mtr. 95.001585 14.47Taking out CI cover with frame from stone slab /RCC slab of inspection chambers of varioussizes including dismantling of stone slab / RCCslab roofing and stacking of useful materials nearthe site and disposal of unserviceable materialswithin 50- meter lead.Each 206.001586 14.48Taking out C.I. cover with frame from stone slab /RCC slab of manholes of various sizes includingdismantling of stone slab / RCC slab roofing andstacking of useful materials near the site anddisposal of unserviceable materials within 50-meter lead.Each 121.001587 14.49Dismantling of RCC spun vent shaft includingexcavating the cement concrete pit completely,taking out the shaft, refilling the excavated gapstacking the useful material near the site anddisposal of unserviceable materials within 50meter lead.Each 1,398.001588 14.50Dismantling of gully chamber of various sizesincluding CI grating with frame including stackingof useful materials near the site and disposal ofunserviceable material within 50 meter leadincluding refilling the gap.Each 281.001589 14.52Dismantling of CI sluice valve including stackingof useful materials within a lead of 50 meter:14.52.1 Up to 150mm dia. 14.52.2 Above 150mmdia. Each 388.00Each 109.001590 14.53 Dismantling of spindle fire hydrant includingstacking of useful material within 50 meter lead.Each 234.001591 14.54Dismantling of cement concrete platform alongwith curtain walls and base concrete etc.including stacking of useful materials near thesite and disposal of unserviceable materialswithin 50 metres lead : 14.54.1 Upto1.44 Sqm14.54.2 Above1.44 Sqm to2.52 Sqm Sqm508.00 14.54.3 Above2.52 Sqm to3.84 SqmSqm 762.00Sqm 342.001592 14.55Dismantling old plaster or skirting, raking outjoints and cleaning the surface for plasterincluding disposal of rubbish to the dumpingground within 50 meter lead.Sqm 17.001593 14.56Dismantling CC jali including cost of makinggrooves in plaster and making good andincluding disposal of unserviceable surplusmaterial and stacking of serviceable material within 50 meters lead as directed by Engineer-in-charge. .Sqm 88.001594 14.57Removing aluminium/Gypsum partitions, doors,windows, fixed glazing and false ceiling includingdisposal of unserviceable material and stackingof serviceable material with in 50 meters lead asdirected by Engineer-in-charge.Sqm 19.001595 14.58Making of hole(width up to 150 mm) in R.C.C.slab/wall/beams by power driven drilling machinecomplete as per direction of EI 14.58.1 upto150mm thick 14.58.2 above 150 mm thick Each297.00Each 194.001596 15.1Providing and laying water proofing treatment tovertical and horizontal surfaces of depressedportions of W.C., kitchen and the like consistingof :(i) Ist course of applying cement slurry @4.4Kg/sum mixed with water proofing compoundconforming to IS 2645 in recommendedproportions including rounding off junction ofvertical and horizontal surface.(ii) IInd course of20mm cement plaster1:3(1 cement: 3 coarsesand) mixed with water. proofing compound inrecommended proportion including rounding offjunction of vertical and horizontal surface..(iii)IIIrd course of applying blown or residual bitumenapplied hot at1.7 Kg per sqm. of area. iv) IVthcourse of 400 micron thick PVC sheet.(Overlapsat joints of PVC sheet should be 100 mm wideand pasted to each other with bitumen @1.7Kg/sqm.)Sqm. 564.001597 15.2Providing and Placing in position suitable PVCwater stops conforming to IS:12200 forconstruction/ expansion joints between two RCCmembers and fixed to the reinforcement withbinding wire before pouring concrete etc.complete : 1598 15.2.1 Serrated with central bulb(225 mm wide,8-11mm wide)Rm 876.001599 15.2.2 Dumb bell with central bulb(180 mm wide, 8 mmwide)Rm 506.001600 15.2.3 Kickers(320 mm wide, 5 mm thick) Rm 519.001601 15.3Providing and laying water proofing treatment insunken portion of WCs, bathroom etc., byapplying cement slurry mixed with water proofingcement compound consisting of applying :a) firstlayer of slurry of cement @0.488 kg/sqm mixedwith water proffing cement compound@0.253kg//sqm .This layer will be allowed to air cure for4 hours.b) Second layer of slurry of cement @0.242 kg/sqm mixed with water proffing cementcompound @0.126 kg/sqm This layer will beallowed to air cure for 4 hours followed by watercuring for 48 hours. The rates includespreparation of surface treatment & sealing of alljoints,corners, junction with polymer mixed slurry.Sqm. 303.001602 15.4Providing and laying water proofing treatment onroofs of slabs by applying cement slurry mixedwith water proofing cement compound consistingof applying :a) after surface preparation, firstlayer of slurry of cement @0.488 kg/sqm mixedwith water proffing cement compound @0.253kg/sqm.b) laying second layer of Fiber glass clothwhen the first layer is still green . Overlaps ofjoints of fiber cloth should not be less than 10 cm .c) Third layer of 1.5 mm thickness consisting ofslurry of cement @1.289 kg/sqm mixed withwater proffing cement compound @0.670kg/sqm and coarse sand @1.289 kg/sqm. Thiswill be allowed to air cure for 4 hours followed bywater curing for 48 hours. The entire treatmentwill be taken upto 30cm on parapet wall andtucked into groove in parapet all aroundd) fourthand final layer of brick tiling‘with cement mortaror any other approved protective coarse.(whichwill be paid for separately) For the purpose ofmeasurement the entire treated surface will bemeasuredSqm. 299.001603 15.5Providing and laying four courses water proofingtreatment with bitumen felt over roofs consistingof first and third courses of blown bitumen 85/25or 90/15 conforming to IS : 702 applied hot1.45Kg. per square meter of area for eachcourse, second course of roofing felt type 3grade–I(Hessian based self finished bitumenfelt)and fourth and final course of stone grit6mmand down size of pea sized gravel spread at 6cubes diameter per square meter includingpreparation of surface, but excluding grading,complete with Bitumen felt(Hessian base) type 3grade - I conforming to : 1322.Sqm. 389.001604 15.6Providing and laying six courses water proofingtreatment with bitumen felt over roofs consistingof first, third and fifth course of blown bitumen85/25 or 90/15 conforming to IS : 702 applied hot@ @1.45,1.20 and1.45 Kg per sqm. of arearespectively second and fourth courses of roofingfelt type 3 grade-I conforming to IS 1322(Hessian based self finished bitumen felt)conforming to IS 1322 and sixth and final courseof stone grit6mm and down size of pea sizedgravel spread at 6 cubic dm. per square metreincluding preparation of surface but excludinggrading complete .Sqm. 603.001605 15.7Providing and laying six courses water proofingtreatment with bitumen felt over roofs consistingof first, third and fifth courses of blown or/andresidual bitumen applied hot at1.45,1.20 and1.70 Kg. per Sqm. of area respectively secondand fourth courses of roofing felt type 2 grade-I(fiber base self finished bitumen felt) and sixthand final course of stone grit6mm and down sizeor pea sized gravel spread at8cu.dm per sqmincluding preparation of surface excludinggrading complete confirming to IS : 1322 and1346.Sqm. 655.001606 15.8Providing and laying six courses water proofingtreatment with bitumen felt over roofs consistingof first, third and fifth courses of blown or/andresidual bitumen applied hot at1.45,1.20 and1.70Kg. per Sqm of area respectively secondand fourth courses of roofing felt type 2 grade 2 (fiber base self finished bitumen felt) and sixthand final course of stone grit6mm and down sizeof pea sized gravel spread at8cu.dm per sqmincluding preparation of surface excludinggrading complete confirming to IS : 1322 and1346.Sqm. 655.001607 15.9Supplying and applying bituminous solutionprimer on roofs or on wall surface at0.24 liter persqm.Sqm. 25.001608 15.10Deduct for omitting in water proofing treatmentfinal course of spreading stone grit6mm. anddown size of pea sized gravel:1609 15.10.1 At6dm3 per Sqm. Sqm. 11.001610 15.10.2 At8dm3 per Sqm. Sqm. 13.001611 15.11Providing and laying APP(Atactic PolypropylenePolymer) modified prefabricated five layer3mmthick water proofing membrane, black finishedreinforced with glass fibre matt consisting of acoat of bitumen primer for bitumen membrane @ 0.40 Itr/sq.mt. by the same membranemanufacture of density at 25°C,0.87-0.89 kg/ltrand viscosity 70-160 cps. Over the primer coatthe layer of membrane shall be laid using ButaneTorch and sealing all joints etc., and preparingthe surface complete. The vital physical andchemical parameters of the membrane shall beas under Joint strength in longitudinal andtransverse direction at 23°C as 650/450N/5cm.Tear strength in longitudinal and transversedirection as 300/250N. Softening point ofmembrane not less than 150°C. Cold flexibilityshall be upto-2°C when tested in accordancewith ASTM,D-5147. The laying of membraneshall be got done through the authorizedapplicator of the manufacturer of membrane. 3mm thickSqm. 413.001612 15.12Providing and laying APP(Atactic PolypropylenePolymer) modified prefabricated five layer3mmthick water proofing membrane, black finishedreinforced with non-woven polyester mattconsisting of a coat of bitumen primer for bitumenmembran @0.40 Itr/sq.mt. by the samemembrane manufacture of density at 25°C,0.87-0.89 kg/ltr and viscosity 70-160 cps. Over theprimer coat the layer of membrane shall be laidusing Butane Torch and sealing all joints etc.,and preparing the surface complete. The vitalphysical and chemical parameters of themembrane shall be as under Joint strength inlongitudinal and transverse direction at 23°C as650/450N/5cm. Tear strength in longitudinal andtransverse direction as 300/250N. Softeningpoint of membrane not less than 150°C. Coldflexibility shall be upto-2°C when tested inaccordance with ASTM,D-5147. The laying ofmembrane shall be got done through theauthorized applicator of the manufacturer ofmembrane.3 mm thickSqm. 474.001613 15.13Extra for covering top of membrane withGeotextile, 120gsm non woven, 100% polyesterof thickness 1 to1.25mm bonded to themembrane with intermittent touch by heating themembrane by Butane Torch as per manufacturesrecommendation.Sqm. 62.001614 15.14Extra over items of Cement Plaster / CementConcrete flooring / 125 gm Plain or RCC workProviding and mixing admixture of synthetic Fiber 6mm / 12mm. @ rate of 125gm. pack per 50 Kg.of Cement or in the ratio of as specified bymanufacture specification and direction ofEngineer In-charges with all leads and lifts.P Pack 63.001615 15.15Supplying and providing of two components polysulphide sealant containing solid contents,confirming to standard specification andapproved compatible primer, for priming verticalfaces prior to application of poly sulphide sealantincluding all labour charges for sealing ofexpansion joints after drill mixing of twocomponents sealing compound. Cleaning andpreparation of expansion joint using wire brushsand papering with emery paper and filing withsuitable mechanical means. The work includesracking and cleaning of joints, sticking,debonding tape on bottom of joint, applyingprimer on edges, using masking tape on edges,providing of sealant and removal of masking tapeimmediately after providing sealant in joint.1616 15.15.1To vertical joint between RCC columns, bricks &stone masonry in size 40 mm width and 12 mmdepth, including providing back up material (Thermocoal foam) if required.Mtr. 911.001617 15.15.2To joints in flooring, as per drawing with first layerof poly sulphide sealant in size 20 mm width and10 mm depth over PE Foam and then providingpolyethylene foam back up rod 25 mm dia sizeand finally providing another layer of polysulphide sealant in size 20 mm width and 10 mmdepth over P.E. back up rod as per applicationprocedure and direction of Engineer-in-charge.Mtr. 952.001618 15.16Providing and fixing in position bitumenimpregnated fiberboard confirming to IS: 1838 inexpansion joints including the cost of primersealing compound. 1619 15.16.1 12 mm. thick Sqm. 666.001620 15.16.2 18 mm. thick Sqm. 871.001621 15.16.3 25 mm. thick Sqm. 1,137.001622 15.17Providing and fixing expansion joint board forbuilding RCC column beams, walls, slab ofPolyethylene foam of density 30 to 35 Kg/m3 ofArmour Board. 1623 15.17.1 20mm Thick Sqm. 458.001624 15.17.2 25 mm Thick Sqm. 542.001625 15.17.3 30 mm Thick Sqm. 619.001626 15.17.4 40 mm Thick Sqm. 789.001627 15.17.5 50 mm Thick Sqm. 837.001628 15.18Providing and fixing 150 mm wide sheet coveringover expansion joints with iron screws as perdesign to match the colour / shade of walltreatment. 1629 15.18.1 Non-asbestos fibre cement board 6 mm thick asper IS:14862.1Rm. 128.001630 15.18.2 Aluminum fluted strips 2 mm thick Rm. 450.001631 15.18.3 Acrylic sheet 5 mm thick Rm. 121.001632 15.19Providing and filling in position bitumen sealingcompound P. Cm. grade A(IS 1834) inexpansion joints. Width for 100mtr. lengthP.Cm. depth 713.001633 15.20Providing and filling in position bitumen mix fillerof proportion 80 width per Kg. of hot bitumen, 1Kg. of cement and0.25 cubic meter of coarse cmdepth per 100 mtr. sand for expansion joints.lengthPer cm 223.001634 15.21Providing and fixing in cement sand mortar 1 : 3single/double rebated R..C. Door Window andventilator frames(Chowkhats) including1%reinforcement as per design and concrete mix 1 :2 : 4 cutting etc. complete incl. horns. and holdfasts : 1635 15.21.1 Size 75 x 50mm Mtr. 142.001636 15.21.2 Size 75 x 75mm Mtr. 161.001637 15.21.3 Size 100 x 75mm Mtr. 169.001638 15.21.4 Size 125 x 75mm Mtr. 182.001639 15.22 Extra for RC frames(Chowkhats) Curved in planMtr. 10%1640 15.23 Extra for RCC frame finishing the exposed facewith terrazo Mtr. 20%(Mosaic) finish.1641 15.24Providing and fixing in cement sand mortar 1 : 4single paitam(rebated) stone doors windows andventilator frames of approved quarry:1642 15.24.4 Size 100x 75mm Mtr. 298.001643 15.24.5 Size 125 x 100mm Mtr. 317.001644 15.25Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilatorframes of approved quarry:1645 15.25.1 Size 100 x 75mm. Mtr. 286.001646 15.25.2 Size 125 x 100mm Mtr. 347.001647 15.26Providing & mixing admixture in CementConcrete flooring/Cement Plaster/Plain or RCCwork, Synthetic Polyster Triangular ConstructionFiber of length6mm/12mm/18mm with specificgravity1.34 to1.40 and diameter 10-40 micronsand melting point>220 degrres centigrade byusing 125 gm fiber for 50 kgs cement used asper direction of Engineer-in-charge.Kg 488.001648 15.27Providing & mixing admixture in Cement MassConcrete flooring CC Road, RCC work, CanalLining and Shotcrete Non Circular with ribbedsurface Structural Synthetic Macro Fiber 42-50mm length, specific gravity of >1.30 anddiameter0.8 -1.20mm and melting poing > 220degree centigrade @0.75% -100% by cementweight in mix as per direction of Engineer-in-charge.Kg 639.001649 15.28 Nano technology water proofing, thermalinsulation protection coating1650 15.29Providing and Applying ACRYLIC emulsionpolymer waterproofing chemical coating, on overroof on over roof slabs/terrace/balconies/parapetwall etc.with following method/specification:Paintthe surface with regular paint brush so as toobtain approximately0.3mm thickness coating.apply the2nd coat next day at right angles to the1st coat so that total thickness of the coatingshould be approximately0.6mm coverage byusing above formulation will be 40 ft2/ litre ofchemical. painted surface does not require anyexternal water curing since chemical will holdsufficient water for curing.After the primer coatApply 2 coats of modified acrylic emulsionpolymer water proofing compound having solarheat reduction properties coating @0.330KG/SQM on the surface of the interval of3-4hours. Undulation on the surface is repair beforethe waterproofing work.Sqm 579.001651 15.30Providing & applying one coat of UV resistantpolymer cement based waterproofing slurrycoating of approved make and quality onconcrete or plastered surface as perspecifications including preparation of surface bycleaning brushing and dust removing, filling ofcracks and making the surface leak proof bymixing one part of chemical with 2 parts ofcement and 2 parts of water(covering area1.86Sq.M/Kg of chemical) including cost of cement,labour, tools & plant, scaffolding if necessaryetc., complete as directed by Engineer in Charge.with Cement Motor before application and thesame will be paid under relavent items.Sqm 268.001652 15.31Providing & applying Three coat of Acrylic WaterProof membrane having sunlight and UVresistant properties over waterproofing slurrycoat , initial coat of 50-75 micron thickness withdiluting 1 part of chemical with 2 parts of cleanwater, over which applying 2 coats at 2 Hrs .intervals each with diluting 1 part of chemicalwith 20% of clean water for total thickness of 400to 450 microns(covering area0.9 Sq.M/Kg ofchemical including preparation of surface bycleaning, brushing and dust removing,scaffolding if necessary etc., with contractorslabour, tools, machinery etc, complete asdirected by Engineer in Charge.Sqm 535.001653 15.32Providing & applying Three coat of pure AcrylicWater based elastomeric brush applied insulatingcoating on exterior surface overwaterproofingslurry coat , initial coat of 50-75 micron thicknesswith diluting 1 part of chemical with 2 parts ofclean water, over which applying 2 coats at 2Hrs, intervals each with diluting 1 part ofchemical with 10% of clean water for totalthickness of 400 to 450 microns(covering area0.9 Sq.M/Kg of chemical) including preparation ofsurface by cleaning, brushing and dust removing,scaffolding if necessary etc., with contractorslabour, tools, machinery etc, complete asdirected by Engineer in Charge.Sqm 574.001654 15.33Providing and fixing 50mm thick extrudedpolystyrene rigid insulation board of required sizebetween cavity wall, complying with ISO4898:2008 & ASTM C 578-08b - type VI havingthermal conductivity of0.0289W/m K as perASTM C 578(measured as per IS 3346),compressive strength of>350 kPa listed as perASTM D 1621, density of 34-36 kg/m3 as perASTM D 1622, water absorptions=<1% byvolume as per ASTM D 2842, oxygen index of24.1 to 28.1 listed as per ASTM D 2863, cell size 0.4 mm of dia (max) as per ASTM D 3576. Fireretardent property as per DIN 4102, part 1 ofclass B2 and as per ASTm E84 class A, fixedwith suitable water based adhesive and fastener,complete in all respect as per the diretion ofEngineer-in-Charge.Sqm 725.001655 15.34Providing & fixing 50mm extruded polystyrene (XPS) insulation board density 36kg/m3, under orover RCC roof slab complete as permanufacturing specifications fixed with1%suitable water based adhesive and fastener,complete in all respect as per the direction ofEngineer-in-Charge.Sqm 728.001656 15.35Supply and Application of Solar IR HeatReflective Coating System conforming to BIS StdIS 17218:2019 for concrete surface having minorleakage by thorough surface preparation toremove dust, dirt, molds etc. using High PressureWaterJet / Wire Brush etc, opening of cracks andfilling with elastomeric crack filler, then applyingone absorption coat of UV resI tan1 elastomericcoating having min. 50% solids(i.e. ThermacoolWP 51/or Equivalent), followed by application ofelastomeric clear coating White Cementwaterproofing coat having min. 400% elongationand tensile strength of2.2 MPa and than topcoating with 2 Coats of Solar lR Heat ReflectiveCoating conforming to BIS Standard IS17218:2019(i.e. Therrnacool0.3C/or Equivalent)of cementitious surfaces, white colour, matt,surface coverage3.25 sqm/Ltr/2 wat, dft 100-120microns.The work shall be done as per thedirections of Engineer-in-charges. water basedpure acrylic, UV resistant, Solar lR HeatReflective coating with Pull off Adhesion2.8Mpa, passes 2000 hrs accelerated durability test,suitable for all types of cementitious surfaces,white colour, matt, surface coverage3.25sqm/Ltr/2 wat, dft 100- 120microns.The workshall be done as per the directions of Engineer-in-charges.Sqm 638.001657 1.1P. & F Squatting Pan(Indian type) white glazedvitreous china1st quality W.C. Pan(IS : 2556Mark) with 100 mm vitreous china P or S trapincluding cutting and making good the wall andfloor(excluding the pair of foot rest.)1658 1.1.1 Size 450mm. Each 1,269.001659 1.1.2 Size 510 mm Each 1,383.001660 1.1.3 Size 580mm Each 1,453.001661 1.2P & F Indian type white glazed vitreous china1stquality W.C. orissa pan(IS:2556 Mark) with 100mm vitreous china P or S trap including cuttingand making good the wall and floor:1662 1.2.1 Size 530x410mm. Each 3,168.001663 1.2.2 Size 580x440mm. Each 3,696.001664 1.3P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or Strap including cutting and making good the walland floorEach 2,893.001665 1.4P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark)with P or S trap including cutting and makinggood the wall and floorEach 5,717.801666 1.5P & F Universal(anglo-Indian type) white glazedvitreous china W.C. pan1st quality(IS 2556Marked) with P or Strap including cutting andmaking good the wall and floorEach 4,678.201667 1.6P & F European type white glazed vitreous china 1st quality W.C. (IS : 2556 Mark) including cuttingand making good the wall and floor1668 1.6.1 Wall Mounting Each 3,774.001669 1.6.2 Wall Mounting (extended) Each 6,299.001670 1.6.3Wall Mounting(syphonic)(A) Add extra over itemNo.1.1 to1.7,1.14,1.15,1.19,1.22 Each 50%,1.23,1.38 &1.42 for using approved lightcoloured vitreous china ware i.e.ivorychampagne , perl , soft green , soft blue,pink,,light grey etc. instead of white vitreouschinawares.(B) Add extra over item No.1.1 to1.7,1.14,1.15,1.19,1.22 Each 65%,1.23,1.38 &1.42 for using approved dark colored vitreouschina ware i.e.Cherry Red , Dark blue, Jet black,Magenta, Burgandy instead of white vitreouschinawares.Each 6,777.001671 1.7 P & F water closet Seat Covers with brass hingescomplete :1672 1.7.1 Solid PVC(IS 2548 marked) grade-I Black forEWC.Each 517.001673 1.7.2 -do- White. Each 631.001674 1.7.3 -do- Coloured. Each 644.001675 1.7.4 -do- White. Each 484.001676 1.7.5 -do- Coloured. Each 527.001677 1.8 P & F C.P. lugs for toilet seat cover. Pair 119.001678 1.9Labour charges for removing W.C. pan (anytype) of all sizes with care including all necessaryfittings P or S trap.Each 429.001679 1.10 P & F White glazed Conversion Bend for W.C.from P trap to S trap. . Each 214.001680 1.11 P & F vitreous china P trap of approved quality Each 258.001681 1.12 Add extra if C.I.P trap is used in place of Vitreouschina P trap for W.C. Each 653.001682 1.13P & F White Vitreous China Double SyphonicEuropean W.C.(I.S:2556Mark) with mountedW.V.C. flushing cistern of(IS : 2556 Mark) of 10litre capacity complete with all necessary internalfittings including cutting and making good thewall and floor.Each 13,325.001683 1.14P & F lst quality WVC Urinal(IS:2556 mark) with25mm dia G.I. waste pipe, dome wastecouplings, concealed iron brackets or screws etccomplete. 1684 1.14.1 Flat Back(small) size 456x355x265mm. Each 2,266.001685 1.14.2 Flat Back(large) or half stall size 610x400x80mm.Each 5,475.001686 1.14.3 Mini stall size 455x385x350mm. Each 3,102.001687 1.15P & F W.V.C. Urinal Partition Plate of approvedstandard make of size 630x315mm includingmaking good the wall.Each 1,379.001688 1.16P&F Marble Urinal Partition slab both sidespolished of approved design cut from marble size900x600mm. 1689 1.16.1 Makrana II quality marble having light spots Each 1,061.001690 1.16.2 Makrana `Albeta` Marble having light streaks. Each 991.001691 1.16.3 Makrana`Adanga` or Raj Nagar1St QualityWhite or Andhi Indo-Italian marble.Each 921.001692 1.17P & F W.V.C. Half-Round Channel of approvedmake in C.M.1:3, joints finished in white cementof: 1693 1.17.1 Size 100mm dia. Mtr. 673.001694 1.17.2 Size 150mm dia. Mtr. 871.001695 1.18P & F W.V.C.(IS: 2556 Mark) Squatting Urinal ofstandard make complete. Including cutting &making good the floor:1696 1.18.1 Size 450x350mm Each 1,430.001697 1.19Labour charges for removing and refixing ofurinals (all type & sizes) including all necessaryfittings.Each 390.001698 1.20P & F Low level Flushing Cistern of 10 litrescapacity(IS : 2556mark). Of approved make withcomplete fittings C.I. brackets duly painted, brassball cock with ball,(IS: 1703 mark) completeincluding cutting and making good the wall:1699 1.20.1 WVC with C.P. brass bend. Each 2,980.001700 1.20.2 PVC with PVC bend as per IS : 7231. Each 1,549.001701 1.20.3 PVC with PVC bend and superior internal fittings Each 1,974.001702 1.20.4 WVC for symphonic EWC. Each 3,119.001703 1.20.5 PVC with CP brass long band. Each 1,789.001704 1.21P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, siphonwith copper tube,C.I. brackets completeincluding cutting and making good the wall. WVC (as per IS : 2556) 10 litres.Each 1,310.001705 1.22 P & F Flush Pipe of approved make withcomplete fittings for high level flushing cistern:1706 1.22.1G.I.`B` class(Concealed) 25mm. Each 527.001707 1.22.2G.I.`B` class(Concealed) 32 mm. Each 616.001708 1.22.3 PVC exposed(heavy) 32mm. Each 202.001709 1.22.4 GI(Sheet) hot galvanized exposed(10 litres). Each 305.001710 1.23 P & F WVC(10 litres) low-level flushing cisternwith cover.Each 870.001711 1.24 P & F WVC(10 litres) low-level flushing cisterncover only Each 367.001712 1.25 P & F WVC syphon with plunger plate only. Each 293.001713 1.26 P & F WVC Auto cistern with cover only. Each 554.001714 1.27 P & F WVC Auto cistern cover only. Each 174.001715 1.28P & F C.P. brass Urinal Flush Pipe set completewith flanged brackets of approved make.1716 1.28.1 For 4 Urinals Each 1,597.001717 1.28.2 For 3 Urinals Each 1,282.001718 1.28.3 For 2 Urinals Each 883.001719 1.28.4 For 1 Urinal Each 605.001720 1.29.1 P & F C.P. brass Urinal Spreader for stall urinalof approved make. Each 436.001721 1.29.2 P & F Synthetic (PTMT) Urinal Spreader for stallurinal of approved make. Each 295.001722 1.30.1 P & F C.P. brass Doom Waste Coupling 32 mmdia.Each 199.001723 1.30.2 P & F C.P. brass Doom Waste Coupling 40 mmdia.Each 253.001724 1.31 P & F Plastic Syphon of approved make forautomatic flush tank. Each 190.001725 1.32 P & F Copper tube Syphon for auto flush tank. Each 450.001726 1.33 Removing and re-fixing of wash hand basinincluding all necessary fittings. Each 291.001727 1.34 P & F metal brackets duly painted includingcutting & making good the wall. Pair 197.001728 1.35 P & F C.P. Brass flush Valve with C.P. flush bendof approved make.1729 1.35.1 Lever type with Elbow 32 mm dia Each 4,005.001730 1.35.2 Push type with Elbow 32 mm dia Each 4,449.001731 1.35.3 Concealed type for 115 mm thick wall Each 5,047.001732 1.35.4 Concealed type for 230 mm thick wall Each 5,202.001733 1.35.5 Economy model 25 mm dia. Each 2,499.001734 1.35.6 Economy model 32 mm dia. Each 2,914.001735 1.36P & F WVC Wash basin(Ist quality IS:2556Mark) of approved make with C.I. brackets dulypainted 1 No. 15 mm C.P. Pillar cock(IS:8934Mark) & 32 mm C.P. brass waste coupling ofapproved make,P.V.C Waste pipe with PVC nut32 mm complete including cutting & making goodthe wall : 1736 1.36.1 Size 450 mm x 300 mm Each 2,734.001737 1.36.2 Size 510 mm x 400 mm Each 2,880.001738 1.36.3 Size 550 mm x 400 mm Each 3,064.001739 1.36.4 Size 580 mm x 450 mm Each 3,516.001740 1.36.5 Size 610 mm x 510 mm Each 4,278.001741 1.36.6 Size 400 mm x 400 mm or 450 mm x 390 mmCorner Each 2,738.001742 1.36.7 460 dia for counter top Each 3,921.001743 1.36.8 Size 550 mm x 400 mm dia for counter top Each 4,119.001744 1.36.9 Size 630 mm x 500 mm dia for counter top Each 4,633.001745 1.36.10 Add extra for using 25mm GI waste pipe insteadof PVC waste pipe Each 108.001746 1.37P & F Terrazzo (Mosaic) wash hand basin withsupporting brackets waste coupling and PVCwaste pipe complete, including painting ofbrackets making good the walls:1747 1.37.1 450 mm x 280 mm Each 1,332.001748 1.37.2 550 mm x 400 mm Each 1,427.001749 1.38P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. wastecoupling,C.P. Brass chain with rubber plug, 40mm G.I. waste pipe up-to floor level completeincluding cutting and making good the wall &floor : 1750 1.38.1 Fire clay glazed kitchen sink(I.S 771-1985Marked) size 600 x 450 x 250mm.Each 5,181.001751 1.38.2 Fire clay glazed kitchen sink(I.S 771-1985Marked) size 600 x 450 x 200 mm.Each 4,970.001752 1.38.3 WVC Lab sink(IS:2556 mark) size 530 x 430 x180 mmEach 3,259.001753 1.38.4 WVC Lab sink(IS:2556 mark) size 500 x 350 x150 mmEach 2,850.001754 1.38.5 WVC Lab sink(IS:2556 mark) size 450 x 300 x150 mmEach 2,655.001755 1.38.6 Mosaic fine polished kitchen sink size 600 x 450x 200mm.Each 1,803.001756 1.38.7 Mosaic fine polished kitchen sink size 450 x 450x 200mm.Each 1,637.001757 1.38.8 Mosaic fine polished kitchen sink size 600 x 450x 200 mm with 600 x 450mm drain board Each 2,056.001758 1.38.91.0 mm thick stainless steel AISI-304 & IS13983-1994 kitchen sink of approved make asper Engineer-in-charge with large wastecoupling. Overall size Bowl size(inches)(inches)1759 1.38.9.1 18 x 16 x 6 16x14x6 Each 5,029.001760 1.38.9.2 22 x 18 x 7 20x16x7 Each 5,632.001761 1.38.9.3 24 x 18 x 8 20x16x8 Each 6,588.001762 1.38.9.4 37 x 18 x 7 17x15x7(with drain board) Each 7,858.001763 1.38.9.5 45 x 20 x 8 20x16x8(with drain board) specifiedabove.Each 9,866.001764 1.39P & F Drain Board of approved make with C.I.brackets duly painted compolete including cutting& making good the wall:1765 1.39.1 WVC(I.S.: 2556 Mark) size 530 x 450mm Each 1,497.001766 1.39.2 Mosaic fine polished size 600 x 450 Each 557.001767 1.40 P & F1st quality WVC pedestal for wash basin. Each 1,708.001768 1.41 P & F Bottle Trap of approved make :1769 1.41.1C.P Brass 32 mm Each 882.001770 1.41.2C.P Brass 40 mm Each 957.001771 1.41.3 Synthetic Material(PTMT)32 mm Each 614.001772 1.41.4 Synthetic Material(PTMT)42 mm Each 686.001773 1.41.5 P.V.C Each 165.001774 1.42 P& F waste Coulping with fittings of approvedquality /make:1775 1.42.1C.P Brass 32 mm dia Each 206.001776 1.42.2C.P Brass 40 mm dia Each 280.001777 1.42.3C.P. Brass 50 mm dia Each 359.001778 1.42.4 SS 125 mm Each 366.001779 1.43 P& F waste Pipe with all fitting1780 1.43.1P.V.C with C.P nut 32 mm Each 174.001781 1.43.2P.V.C with PVC nut 32 mm Each 73.001782 1.43.3P.V.C. with C.P. nut 40 mm dia Each 188.001783 1.43.4G.I(B class) 32mm Each 269.001784 1.43.5G.I(B class) 40 mm Each 356.001785 1.44P & F Bevelled edge Mirror/mirror with teak woodlipping around of special glass of approved makeas per direction of Engineer-in-charge completewith6mm thick commercial ply base fixed towooden screws & washers.1786 1.44.1 Size 600 x 450mm x 4 mm thick Each 836.001787 1.44.2 Other sizes deduct 30% Sqm. 2,016.001788 1.45P & F Looking Mirrors with P.V.C. frame ofapproved make as per direction of Engineer-incharge1789 1.45.1 Size 500x400mm Each 421.001790 1.45.2 Oval shape 450x350 mm Each 617.001791 1.45.3 Round 500mm dia deduct 30% Each 659.001792 1.46 P & F Toilet Shelf of approved quality/make:1793 1.46.1W.V.C.(I.S.: 2556 Mark) Size 300mm Each 528.001794 1.46.2W.V.C.(I.S.: 2556 Mark) Size 550 mm Each 624.001795 1.46.3 Synthetic Material with tumbler of approvedquality/make size 470 x 114 x 36mmEach 517.001796 1.46.4 Hard Plastic of approved make as per directionof EI of size 590x140mmEach 624.001797 1.46.5Acrylic shelf on C.P. brass casted brackets &guard rail of approved make as per direction of EIof size 550x125mmEach 1,196.001798 1.46.6Glass Shelf with edges rounded off AnodisedAluminium angle frame &C.P. brass brackets &guard rail size Each 600x120mm438.001799 1.47 P & F Towel Rail or Ring of approvedquality/make: 0.001800 1.47.1C.P. brass Towel Rail elbow type with concealedscrews size 450mm(Heavy duty).Each 533.001801 1.47.2C.P. brass Towel Rail elbow type with concealedscrews size 600 mm(Heavy duty).Each 590.001802 1.47.3C.P. brass towel rail with brackets 450 x 20mm. Each 357.001803 1.47.4C.P. brass towel rail with brackets 600 x 20mm. Each 425.001804 1.47.5 Synthetic Material(PTMT) of approvedquality/make size 525x90 x 75mmEach 231.001805 1.47.6 Synthetic Material(PTMT) of approvedquality/make size 675x90 x 75mmEach 258.001806 1.47.7WVC(1stquality, IS2556 Marked) of approvedmake. Recessed towel Hanger size 108 x108mm.Each 173.001807 1.47.8 C.P. Brass Towel Ring revolving type Each 307.001808 1.47.9 Synthetic Material (PTMT) Towel Ring ofapproved quality/make. Each 211.001809 1.48 P & F Grating of approved quality/make:1810 1.48.1 Stainless Steel Sheet size 125mm dia. Each 100.001811 1.48.2 Stainless Steel Sheet size 125mm dia. HeavyQuality of approved make Each 127.001812 1.48.3 Synthetic Material(PTMT) of approvedquality/make size 125mm dia.Each 154.001813 1.48.4(-do-) 150mm dia. Each 167.001814 1.48.5(-do-) Square 150 x 150 x8mm.(Anti Cockroach)Each 450.001815 1.48.6C.P. brass with frame(Heavy) & superior qualitysize 125mm dia.Each 151.001816 1.48.7(-do-) Light & superior quality size 125mm dia Each 77.001817 1.48.8 Cast Iron. Each 97.001818 1.49 P & F Liquid Soap Container with bracketscomplete of approved make:1819 1.49.1 C.P. brass Each 321.001820 1.49.2 Synthetic Material of approved quality/make: Each 211.001821 1.50 P & F Tooth Paste & Brush Holder of approvedquality/make:1822 1.50.1 C.P. brass Each 180.001823 1.50.2 C.P. brass (Heavy and Superior quality) Each 544.001824 1.50.3 Stainless Steel Each 353.001825 1.51 P & F Toilet Paper Holder with rod of approvedquality/make:1826 1.51.1 C.P. brass Each 291.001827 1.51.2 C.P. brass heavy & Superior quality. Each 763.001828 1.51.3 WVC(1stquality, IS 2556 Marked) recessed size150x150mm.Each 311.001829 1.51.4 (-do-) exposed (-do-) Each 248.001830 1.52 P & F Soap Dish or Tray of approvedquality/make1831 1.52.1 C.P. brass Each 176.001832 1.52.2 C.P. brass heavy and superior quality. Each 284.001833 1.52.3 WVC(1st Quality, IS 2556 Marked) recessedsize 150 x 150 mm.Each 288.001834 1.52.4(-do-) 200x100mm. Each 370.001835 1.52.5(-do-) Soap tray 170mm. Each 288.001836 1.52.6(-do-) Soap Dish 380mm. Each 370.001837 1.53 P & F Twin- peg of approved quality / make1838 1.53.1 C.P. brass Each 134.001839 1.53.2 C.P. brass (heavy)Superior quality Each 245.001840 1.53.3 Acrylic Each 84.001841 1.54 P & F Shower arm 15mm dia of approvedquality/make. 1842 1.54.1C.P.brass heavy & superior quality 150mmProjection.Each 220.001843 1.54.2(-do-) size 220mm(-do-) Each 363.001844 1.54.3(-do-) size 300mm.(-do-) Each 405.001845 1.54.4(-do-) size 370mm.(-do-) Each 448.001846 1.55 P & F Bath Shower of approved quality/make.1847 1.55.1 C.P. brass fixed. Each 220.001848 1.55.2C.P. brass of Heavy & superior quality 150mm. Each 636.001849 1.55.3C.P. brass of Heavy & superior quality, revolvingwith adjustable key 150mm.Each 855.001850 1.56 P & F Extension Pipe for bib cocks of approvedquality/make.1851 1.56.1C.P. brass of Heavy & Superior quality 50x15mm Each 99.001852 1.56.2(-do-) 100 X 15mm. Each 145.001853 1.56.3(-do-) 150 X 15mm. Each 203.001854 1.57P & F Acrylic Toilet accessories set consisting ofTowel rail, shelf, towel ring, soap dish, paste &brush holder & twin peg of approvedquality/make.Each 1,444.001855 1.58 Labour Charges for removing WVC pan:1856 1.58.1 Indian/Orissa pan Each 227.001857 1.58.2 European W.C. Each 227.001858 1.58.3 Flushing cistern Each 96.001859 1.59 P & F Jet spray for water closet with C.P. CopperTube flange of approved make. Each 459.001860 1.60 Providing & fixing C.P.flange for 15mm dia taps. Each 23.001861 1.61Providing and fixing1st quality standard white,grey, ivory, fume red brown, light green, light blueand other light shades glazed tiles confirming toIS : 13753 & IS :15622 of size 200mm x 300mmin walls, floors, steps, pillars etc. laid on a bed ofneat cement slurry finished with flush pointing inthe white cement mixed with pigment to matchthe shade of the tile complete(excluding the costof cement plaster on walls and pillar).Sqm. 809.001862 1.62Providing and fixing1st quality MAT finishedceremic tile size 300x300mm confirming to IS :13755 and IS : 15622 colour such as white, grey,ivory, fume red brown, light green, light blue andother light shades in floors, steps, pillars etc. laidon a bed of neat cement slurry finished with flushpointing in the white cement mixed with pigmentto match the shade of the tile complete(includingthe cost of cement mortar bed1:4).Sqm. 898.001863 1.63Extra for using Marble printed / Granite shade ordark Sqm 10% shade tiles instead of white, grey,ivory, fume red brown, light green, light blue andother light shades in glazed tiles and MATfinished tiles. 1864 1.64Extra for using size above 200x300mm in glazedtiles and Sqm 10% for using 400mm x 400mmMAT finished tiles in place of 300mm x 300mmsize. 1865 1.65P & F C.P. Health Faucet with1Mtr. Long Tube &Hook of approved make and heavy as perdirection of Enginner-in- ChargeEach 702.001866 1.66P & F C.P. brass Urinal Spreader for Large Urinalof heavy duty of approved make as per directionof Enginner-in- ChargeEach 718.001867 1.67Removing & Re fixing of P.V.C. Cistern fittings(Syphon, Ball cock & Handle Set) complete asper direction of Enginner-in-ChargeEach 531.001868 1.68Providing & Fixing Premium Quality white glazedvitreous china Sanitary Wares(IS:2556 Mark) ofapproved make as per direction of Engineer-in-charge including cutting and making good thewall and floor. 1869 1.68.1W.C. orissa pan with 100 mm vitreous china P orS trap(Size 580x440 mm.)Each 3,249.001870 1.68.2 Universal (anglo-Indian type) with P or S trap Each 9,596.001871 1.68.3 Wall Mounting European type W.C. Each 10,338.001872 1.68.4Double Syphonic European W.C. with mountedW.V.C. flushing cistern of 10 litre capacitycomplete with all necessary internal fittings withHydraulic seat cover.Each 19,623.001873 1.69Providing & Fixing premium qulaity WVC Urinalwith PVC waste pipe, dome couplings, concealediron brackets or screws etc. complete.1874 1.69.1Flat Back(small) size 440x265x315 mm.1..69.2Flat Back(large) or half stall size 590x375x390mm. Each 7133.00Each 2,910.001875 1.70 Providing & Fixing premium qulaity W.V.C. UrinalPartition plate of size 630x315 mmEach 3,031.001876 1.71Providing & Fixing premium qulaity WVC Washbasin with C.I. brackets duly painted & 32 mm C.P. brass waste coupling of approved makewith PVC waste pipe complete1877 1.71.1 Size 550 mm x 400 mm Each 2,645.001878 1.71.2 Size 550 mm x 400 mm dia for counter top. Each 3,777.001879 1.72P & F Premiumquality water closet Seat Coverswith brass hinges complete Solid PVC (ISImarked) grade-I White forEach 824.001880 1.73P & F Premium quality Low level Flushing Cisternof 10 litres capacity(IS:2556 mark) of approvedmake as per Engineer-in-charge with completefittings C.I. brackets duly painted, brass ball cockwith ball,(IS:1703 mark) complete includingcutting and making good the wall:Each 2,097.001881 1.74P&F Looking Mirror5mm thick of approved makewith ornamental frame size 50x12 with6mm PlyBoard on Back Side Complete as per approvedsampleSqm 2,544.001882 1.75Supply of Hydraulic Seat Cover for EuropeonWC of superior quality approved make in whiteColourEach 4,666.001883 1.76 Providing & Fixing chair for wall hung W.C. Each 1,845.001884 1.77Providing & Fixing Concealed cistern with Floormounting frame and flush plate of superior qualityand approved sample by Engineer-in-charge. Each 9,415.001885 1.78Providing and fixing new spindle for Bibcock/pillar cock for repairing purpose to solveleakage and proper functioning of tap.Each 131.001886 1.79Providing & Fixing premium quality Toilet cornerGlass Shelf size 225x225mm with C.P. brassbrackets & guard rail edges rounded of SS frame Each 1,796.001887 1.80Providing & Fixing premium quality wastecoupling 32mm half thread as per approved byEngineer in Charge.Each 703.201888 1.81Providing & Fixing Premium quality Bottle trapinternal portion 32mm, size 250mm long wallconnection pipe & wall flange as per approved byEngineer in Charge.Each 1,919.001889 2.1P & F G.I. pipes(Internal Work) with G.I. Fittingsexcluding union(IS:1239 Mark) & MS clampsincluding cutting and making good the walls andfloors:(a) Exposed on wall1890 2.1.1 15 mm dia nominal boreA ClassB Class Mtr.271.00 Mtr. 238.001891 2.1.2 20mm dia nominal boreA ClassB Class Mtr.334.00 Mtr. 296.001892 2.1.3 25mm dia nominal boreA ClassB Class Mtr.423.00 Mtr. 370.001893 2.1.4 32mm dia nominal boreA ClassB Class Mtr.515.00 Mtr. 430.001894 2.1.5 40mm dia nominal boreA ClassB Class Mtr.637.00 Mtr. 548.001895 2.1.6 50mm dia nominal boreA ClassB Class Mtr.793.00 Mtr. 705.001896 2.1.7 65mm dia nominal boreA ClassB Class Mtr.951.00 Mtr. 817.001897 2.1.880mm dia nominal boreA ClassB Class Mtr.1139.00(b) Concealed pipe in wall includingpainting with anticorrosive bitumen paintMtr. 954.001898 2.1.9 15 mm dia nominal boreA ClassB Class Mtr.280.00 Mtr. 247.001899 2.1.1020mm dia nominal boreA ClassB Class Mtr329.00 2.1.11 25mm dia nominal bore2.1.11.1AClass Mtr 369.00 2.1.11.2B Class Mtr 480.00 Mtr 290.001900 2.5.325 mm dia(a) The rates are for ISI marked item.(b) If the items are Non- ISI marked, reduce therate by 25%.Each 2,854.001901 2.6 P & F Pilllar Cocks(IS:8934 Mark) of superiorquality and approved make:1902 2.6.1C.P. Pillar cock, 15 mm dia nominal bore Each 1,539.001903 2.6.2C.P. Pillar cock Elbow action, 15 mm nominalbore.Each 1,378.001904 2.6.3C.P. Pillar cock fancy type,15mm nominal bore.Each 1,857.001905 2.6.4C.P. Pillar cock, Swan-neck with casted spout,15mm nominal bore.Each 2,587.001906 2.6.5C.P. Pillar cock, high-neck, 15 mm nominal bore.Each 1,828.001907 2.6.6 Synthetic Material(PTMT) Pillar cock ofapproved quality / make 15mm nominal bore.Each 492.001908 2.7 P & F Bib Cock(IS : 8931 Mark), Superior qualityof approved make: 1909 2.7.1 Brass 400 gm,15mm nominal bore. Each 938.001910 2.7.2P.V.C.heavy duty, 15mm nominal bore. Each 198.001911 2.7.3C.P. Brass bib cock,15mm nominal bore. Each 1,216.001912 2.7.4(-do-) Long body, 15mm nominal bore weight notless than 690 gmEach 1,529.001913 2.7.5(-do-) Long nose, 15mm nominal bore weight notless than 810 gmEach 1,848.001914 2.7.6(-do-) Elbow-action, 15mm nominal bore. Each 1,843.001915 2.7.7Synthetic Material(PTMT) bib cock of approvedquality/ make, nominal bore, 15mm, 86 mm long. Each 277.001916 2.7.8(-do-) Fancy Type, 122 mm long. Each 356.001917 2.7.9(-do-) Long Body, 175 mm long Each 427.001918 2.8 P & F Stop Cock(IS:8931 Mark), superior quality& of approved make:1919 2.8.1 Brass 400 gm. 15mm nominal bore. Each 948.001920 2.8.2(-do-) 750 gm. 20 mm nominal bore. Each 1,467.001921 2.8.3(-do-) 1350gm. 25 mm nominal bore. Each 2,575.001922 2.8.4C.P. Brass 15mm nominal bore. Each 1,192.001923 2.8.5(-do-) Concealed Stop Cock 15mm. Each 1,252.001924 2.8.6 Synthetic material(PTMT) stop cock of approvedquality/make 15mm.Each 306.001925 2.8.7(-do-) Concealed stop cock 15mm Each 269.001926 2.9 P & F Sink Cocks of superior quality & approvedmade :1927 2.9.1C.P. Sink cock swinging spout 15mm. Each 2,102.001928 2.9.2(-do-) Casted Spout 15 mm. Each 2,102.001929 2.10 P & F Push Cock superior quality, of approvedmake2..10.1C.P. Brass 15 mm.Each 479.001930 2.10.2 Synthetic Material(PTMT) push cock ofapproved quality/make 15mm.Each 308.001931 2.11 P & F Ball Cock(IS:1703 Mark) with Rod &P.V.C. Ball complete:1932 2.11.1 Brass wt. Not less than 300 gm,15mm. Each 423.001933 2.11.2 Brass wt.Not less than 400 gm, 20mm. Each 617.001934 2.11.3(-do-) wt.Not less than 600 gm, 25mm. Each 717.001935 2.11.4(-do-) wt.Not less than 800 gm, 32mm. Each 825.001936 2.11.5(-do-) wt.Not less than 1000 gm 40mm.: Each 1,004.001937 2.11.6(-do-) wt.Not less than 1200 gm 50mm. Each 1,090.001938 2.11.7 Synthetic material(PTMT) of approved make15mm nominal size.Each 421.001939 2.11.8(-do-) 20 mm nominal size. Each 612.001940 2.11.9(-do-) 25 mm nominal size. Each 1,050.001941 2.11.10(-do-) 50 mm nominal size. Each 2,562.001942 2.12P & F Inlet Connection (Angle Valves) Superiorquality, of approved make, for Wash basin, Gyseretc.1943 2.12.1C.P. Inlet connection 15mm.Brass(IS : 8931marked)Each 596.001944 2.12.2 ---do--- with 37 cm long pipe and nut. Each 660.001945 2.12.3 ---do--- with 60 cm long thread and nut Each 706.001946 2.12.4 Synthetic Material(PTMT) Inlet connection ofapproved quality/make 15 mm nominal size.Each 265.001947 2.13 P & F 15 mm. Dia Connection Pipe of approvedquality/make : 1948 2.13.1 PVC pipe with C.P. Brass nuts upto length,300mmEach 99.001949 2.13.2(-do-) upto length 370mm Each 108.001950 2.13.3(-do-) 450mm. Each 124.001951 2.13.4(-do-) 600mm. Each 143.001952 2.14 P & F Flush Cock / Flush Valve(IS : 9758 Mark)for WC of approved quality make:1953 2.14.1 CP brass push type 15mm nominal bore. Each 448.001954 2.14.2(-do-) 20mm nominal bore. Each 676.001955 2.14.3(-do-)exposed 25mm nominal bore. Each 1,201.001956 2.14.4(-do-) 32mm nominal bore. Each 1,626.001957 2.14.5(-do-) concealed 25mm nominal bore. Each 1,219.001958 2.14.6(-do-) concealed 32mm nominal bore. Each 1,778.001959 2.14.7(-do-) Half-turn exposed 25mm nominal bore. Each 979.001960 2.14.8(-do-) Concealed 25mm nominal bore. Each 1,128.001961 2.14.9 Brass / Gun metal Half-turn wt. 1 Kg. of approvedquality / make, 25mm nominal bore.Each 689.001962 2.14.10 CP Brass flush valve 32mm nominal bore Each 2,491.001963 2.15 P & F Full-way Valve(IS:778 Mark) or wheelvalve of approved make:1964 2.15.1 Gun-metal 15mm nominal bore. Each 284.001965 2.15.2(-do-) 20mm nominal bore. Each 448.001966 2.15.3(-do-) 25mm nominal bore. Each 661.001967 2.15.4(-do-) 32mm nominal bore. Each 879.001968 2.15.5(-do-) 40mm nominal bore. Each 1,343.001969 2.15.6(-do-) 50mm nominal bore. Each 1,830.001970 2.15.7(-do-) 65mm nominal bore. Each 2,229.001971 2.15.8(-do-) 80mm nominal bore. Each 3,338.001972 2.15.9(-do-)100 mm dia nominal bore Each 5,500.001973 2.26P & F PVC Storage Tank ISI Marked(IS : 12701)indicating the BIS license No), of approved makewith cover, 25mm dia1M long G.I. over-flow pipe& 25 Cm. long wash out pipe with plug & socket,including making connection etc., complete ofapproved design: 1974 2.26.2 300(-do-) Each 2,676.001975 2.26.3 500(-do-) Each 4,460.001976 2.26.4 750(-do-) Each 6,691.001977 2.26.5 1000(-do-) Each 8,921.001978 2.27 Hoisting Charges for each floor :1979 2.27.1 For items2.26.1 to2.26.4 Each 155.001980 2.27.2 For items2.26.5 to2.26.8 Each 304.001981 2.31.5 3240(40mm OD) pipe Metre 454.001982 2.33Providing and fixing Superior quality CP Brassfittings of approved make as per direction ofEngineer-in-charge1983 2.33.1 Pillar Cock 15 mm nominal size Each 1,861.001984 2.33.2 Swan neck pillar cock 15 mm nominal size Each 2,460.001985 2.33.3 Bib Cock with long thread 15 mm nominal size Each 1,721.001986 2.33.4 Long body Bib Cock 15 mm nominal size Each 1,851.001987 2.33.5 Two way Bib Cock 15 mm nominal size Each 2,213.001988 2.33.6 Angular stop cock with long thread 15 mmnominal size Each 1,319.001989 2.33.7 Stop cock long thread Each 911.001990 2.33.8 Stop cock with reduced body Each 1,185.001991 2.33.9 Concealed stop cock 15 mm nominal size Each 1,789.001992 2.33.10 Sink cock with swinging casted spout(tablemounted) 15 mm nominal size Each 2,362.001993 2.33.11 Single lever wash basin mixer with 450 mm longcopper connection pipe Each 5,888.001994 2.33.12 Central hole basin mixer Each 4,908.001995 2.33.24 Jet Spray Each 633.001996 2.36.2 PN-16 Pipe, 20 mm OD Rm 202.001997 2.36.3 PN-16 Pipe, 25 mm OD Rm 281.001998 2.36.4 PN-16 Pipe, 32 mm OD Rm 398.001999 2.36.5 PN-16 Pipe, 40 mm OD Rm 556.0011000 2.36.6 PN-16 Pipe, 50 mm OD Rm 763.0011001 2.36.7 PN-16 Pipe, 63 mm OD Rm 1,186.0011002 2.37Providing and fixing Chlorinated PolyvinylChloride(CPVC) pipes, having thermal stabilityfor hot & cold water supply including all CPVCplain & brass threaded fittings i/c fixing the pipewith clamps at1.00 m spacing. This includesjointing of pipes & fittings with one step CPVCsolvent cement and testing of joints complete asper direction of Engineer in Charge.(Internalwork Exposed on wall)11003 2.37.1 15 mm nominal outer dia pipes Rm 227.0011004 2.37.2 20mm nominal outer dia pipes Rm 265.0011005 2.37.3 25 mm nominal outer dia pipes Rm 328.0011006 2.37.4 32mm nominal outer dia pipes Rm 427.0011007 2.37.5 40 mm nominal outer dia pipes Rm 615.0011008 2.37.6 50 mm nominal outer dia pipes Rm 865.0011009 2.38Providing and fixing Chlorinated PolyvinylChloride(CPVC) pipes, having thermal stabilityfor hot & cold water supply including all CPVCplain & brass threaded fittings i/c fixing the pipewith clamps at1.00 m spacing. This includesjointing of pipes & fittings with one step CPVCsolvent cement and the cost of cutting chasesand making good the same including testing ofjoints complete as per direction of Engineer inCharge.(Concealed work including cuttingchases and making good the walls etc.,)11010 2.38.1 15 mm nominal outer dia pipes Rm 287.0011011 2.38.2 20mm nominal outer dia pipes Rm 308.0011012 2.38.3 25 mm nominal outer dia pipes Rm 385.0011013 2.38.4 32mm nominal outer dia pipes Rm 485.0011014 2.39Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stabilityfor hot & cold water supply including all CPVCplain & brass threaded fittings, this includedjointing of pipes & fittings with one step CPVCsolvent cement , trenching refilling & testing ofjoints complete as per direction of Engineer inCharge.(External work).11015 2.39.1 15 mm nominal outer dia pipes Rm 196.0011016 2.39.2 20mm nominal outer dia pipes Rm 227.0011017 2.39.3 25 mm nominal outer dia pipes Rm 293.0011018 2.39.4 32mm nominal outer dia pipes Rm 378.0011019 2.39.5 40 mm nominal outer dia pipes Rm 532.0011020 2.39.6 50 mm nominal outer dia pipes Rm 783.0011021 2.42Providing and fixing premium quality Angular stopcock 15mm with wall flange complete as persample approved by Engineer in chargeEach 1,756.0011022 2.43Providing and fixing premium quality Two wayBib cock 15mm with wall flange complete as persample approved by Engineer in chargeEach 2,707.0011023 2.44Providing and fixing superior quality PVC TankCover complete as per approved by Engineer InCharge11024 2.44.1 300 Lt. capacity Each 267.0011025 2.44.2 500 Lt. capacity Each 285.0011026 2.44.3 Above 500 Lt. capacity Each 298.0011027 2.46Supply and installation of Premium quality sluicevalve 100mm dia including all fittings as perapproved by Engineer in charge.Each 6,059.0011028 2.51 P&F Sink Mixture of (Adjustable or NonAdjustable) Superior quality Swan Neel Each 6,325.00110291For laying of S.W. pipes beyond1.2m depth,earthwork & close timbering or open timbering (as per site conditions) is to be paid extra.11030 3.5P & F Square-mouth gully trap`A` grade(IS 651-1992 :marked) of approved make complete withC.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 baseconcrete, 40mm thick C.C.M-15 grade coping,12mm thick cement plaster in CM1:3 completeas per approved design & type.11031 3.5.1Trap size 150 X 100mm, ferrow cement coverwith frame, Internal Each Chamber size 300 X300mm.1,434.0011032 3.5.2Trap size 225 X 150 mm, ferrow cement coverwith frame Internal Each Chamber size 450 X450mm.1,849.0011033 3.6P & F S.W. Master Trap(Inter-cepting)`A` grade(I.S.: 651 marked) of approved quality/make11034 3.6.1 100mm dia Each 350.0011035 3.6.2 150mm dia Each 495.0011036 3.7Labour charges for Removing S.W. pipesincluding breaking of joints & bed concrete,stacking of useful material at site within 50 mtr.Lead and disposal of unserviceable materialwithin0.5 Km. lead: 11037 3.7.1 100 & 150mm dia pipe Mtr. 53.0011038 3.7.2 200, 230 & 250mm dia pipe Mtr. 58.0011039 3.7.3 300mm dia pipe Mtr. 61.0011040 3.7.4 350mm dia pipe Mtr. 66.0011041 3.7.5 400mm dia pipe Mtr. 72.0011042 3.16P&F rigid PVC Pipe(IS:4985 mark) class II/(4Kg. /Cm2.) approved quality/make includingjoining the pipe with solvent cement rubber ringand lubricant. 11043 3.16.1 63 mm dia Mtr 158.0011044 3.16.2 75 mm dia Mtr 191.0011045 3.16.3 110 mm dia Mtr 300.0011046 3.16.4 160 mm dia Mtr 490.0011047 3.16.5Providing & Laying C.C.1:3:6(Stone Agreegate20mm nominal size) all around PVC Pipeincluding7.5 cm thick bed concerte[Width &Height = Dia of Pipe in CM+15CM] excludingcost of Pipe & Excavation of trenches etc.11048 3.16.5.1 PVC pipe 110 mm dia Mtr. 325.0011049 3.16.5.2 PVC pipe 160 mm dia Mtr. 425.0011050 3.17P&F rigid PVC pipe fittings(IS: 4985 mark) ofapproved quality/make including joining the pipewith solvent cement rubber ring and lubricant:11051 3.17.1 Coupler(socket)(i) 75mm dia(ii) 110mm diaEach 118.00(iii) 160 mm dia Each 129.00 Each 96.0011052 3.17.2 Reducer 110 X 75 mm(i) 75mm dia(ii) 110mmdia Each 107.00(iii) 160 mm dia Each 124.00 Each 99.0011053 3.17.3 Plain Tee(i) 75mm dia(ii) 110mm dia Each199.00(iii) 160 mm dia Each 218.00 Each 124.0011054 3.17.4 Door Tee(i) 75mm dia(ii) 110mm dia Each226.00(iii) 160 mm dia Each 242.00 Each 189.0011055 3.17.5 DoorY(i) 75mm dia(ii) 110mm dia Each 244.00(iii) 160 mm dia Each 260.00 Each 199.0011056 3.17.6 DoubleY(i) 75mm dia(ii) 110mm dia Each316.00(iii) 160 mm dia Each 336.00 Each 199.0011057 3.17.7 Double DoorY(i) 75mm dia(ii) 110mm dia Each399.00(iii) 160 mm dia Each 415.00 Each 233.0011058 3.17.8 Bend 45(i) 75mm dia(ii) 110mm dia Each130.00(iii) 160 mm dia Each 146.00 Each 82.0011059 3.17.9 Bend 87.5(i) 75mm dia(ii) 110mm dia Each164.00(iii) 160 mm dia Each 180.00 Each 99.0011060 3.17.10 Door Bend(Top Side)(i) 75mm dia(ii) 110mmdia Each 157.00(iii) 160 mm dia Each 175.00 Each 134.0011061 3.17.11Door Bend(Left & Right)(i) 75mm dia(ii) 110mmdia Each 199.00(iii) 160 mm dia Each 215.00 Each 161.0011062 3.17.12 Vent Cowel(i) 75mm dia(ii) 110mm dia Each57.00(iii) 160 mm dia Each 78.00 Each 44.0011063 3.17.13 Socket plug(i) 75mm dia(ii) 110mm dia Each83.00(iii) 160 mm dia Each 103.00 Each 69.0011064 3.17.14 Door Cap(i) 75mm dia(ii) 110mm dia Each63.00(iii) 160 mm dia Each 81.00 Each 45.0011065 3.17.15 Pipe Clip(i) 75mm dia(ii) 110mm dia Each 37.00(iii) 160 mm dia Each 54.00 Each 24.0011066 3.17.16W.C. connector with lipring 110mm dia Each 217.0011067 3.17.17W.C. connector bent type 110mm dia Each 227.0011068 3.17.18 Plain floor trap 110mm dia Each 234.0011069 3.17.19 Multi floor trap 110mm dia Each 271.0011070 3.17.20 height Raiser 110mm dia Each 217.0011071 3.17.21 Top Tile& straine 110mm dia Each 82.0011072 3.17.22 Top Tile only 110mm dia Each 63.0011073 3.17.23P- Trap 110mm dia Each 389.0011074 3.17.24Q- Trap 110mm dia Each 436.0011075 3.17.25S- trap 110mm dia Each 545.0011076 3.17.26 Ring fitting 110mm dia3.17.274 Gully trap110mm dia Each 571.00 Each 110.0011077 3.18Raising manhole cover and frames slab torequired level including dismantling existing slaband making good the damage as required(raising depth of manhole masonry to be paidseparately).11078 3.18.1 Rectangular manhole 90x60 cm Each 1,070.0011079 3.18.2 Rectangular manhole 150x120 cm Each 1,636.0011080 3.19Construction of manhole in all type of soil innersize 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 infoundation, 20 mm thick inside plaster in CM1:6,finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mmthick stone slab covering with 40mm thick M-15grade C.C. flooring, Cement cover with frame of450mm dia, earthwork etc. complete as perdesign including disposal of surplus earth within50 mtr. lead. 11081 3.19.1 Depth up to0.5M Each 6,309.0011082 3.19.2 Add extra over item3.19.1 for every additional0.10m depth above0.5 m depth.Each 227.0011083 3.19.3Deduct in Item No3.19.1 for manhole with brickwork 230 mm thick in place of 300 mm thickstone masonryEach 1,146.0011084 3.20Construction of Man hole, in all types of soil,inner size1.5 x1.2M, with 450mm thick masonryin CM1:6, 10 Cm. thick cement concrete1:5:10in foundation, 20mm thick inside plaster in CM 1:6, finished with floating neat cement, 50 mmthick M-15 grade C.C. flooring making channels,80 mm thick stone slab covering with 40 mmthick M-15 grade C.C. flooring, Ferro Cementcover with frame of 450mm dia, earthwork etc.complete including disposal of surplus earthwithin 50 mtr. lead as per design:11085 3.20.1 Depth up to1.5M Each 23,361.0011086 3.20.2 Add extra over item3.20.1 for every additional0.10m depth above1.5 m depth.Each 773.0011087 3.21Construction of chamber in all type of soil with300 mm thick masonry in CM1:6m,10 cm thickC.C.1:5:10 in foundation, 20mm thick insiderplaster in Cm1:6, finished with floating neatcement, 50mm thick M-15 grade C.C. flooring ,earthwork etc. complete as per design includingdisposal of surplus earth within a lead of 50 mtr.11088 3.21.1 Inside size 300 X 300 mm depth upto0.5 MCement cover with frame.Each 1,348.0011089 3.21.1.1 Deduct for using brick work 230 mm thick inplace of 300 mm thick stone masonry 455.0011090 3.21.2-do- size 450 x 450mm depth upto0.5 M Cementcover with frame Each 2,602.0011091 3.21.2.1 Deduct for using brick work 230 mm thick inplace of 300 mm thick stone masonry 508.0011092 3.21.3-do- size 600 x 450mm depth upto0.5 M Cementcover with frame.Each 3,503.0011093 3.21.3.1 Deduct for using brick work 230 mm thick inplace of 300 mm thick stone masonry 529.0011094 3.22.4-do- depth upto0.5 M to1.0 M–do- Each 4,217.0011095 3.21.4.1 Deduct for using brick work 230 mm thick inplace of 300 mm thick stone masonry 811.0011096 3.22Construction of soakage well in all type of soilwith 300 mm thick dry masonry, top and bottom300 mm course in CM1:6, 80mm thick stoneslab, jointing of slab in CM 1 :3, Ralthal,Kharanja, 40 mm thick M-15 grade C.C flooring ,earthwork complete as per approved drawingincluding disposal of earth within a lead of 50 mtr.:11097 3.22.1 Size 300 Cm. dia outside & 300 Cm. depth. Each 31,601.0011098 3.22.2-do- & 240 Cm. Depth. Each 28,613.0011099 3.22.3 Size 240 Cm. dia outside & 240 Cm. depth. Each 22,207.0011100 3.23Construction of soakage Trench in all types ofsoil with 300 mm thick dry stone masonry, 80 mmthick stone slab covering, jointing of slab in CM 1:3 Ralthal, Kharanja, 40 mm thick M-15grade C.C. flooring earthwork etc. complete as perapproved drawing including disposal of earthwithin a lead of 50 Mtr.:11101 3.23.1 Top width 180Cm., bottom width 90Cm. & depth240Cm.Mtr. 6,764.0011102 3.23.2-do- 240 Cm.,-do- 150Cm. & depth 300 Cm Mtr. 11,437.0011103 3.24Construction of Soakage well in all types of soilof approved drawing, top 90 Cm.Portion in450mm thick masonry with CM1:6, 80 mm thickstone slab covering, jointing of slab in CM1:3,Ralthal, kharanja 40mm thick M-15 grade C.Cflooring, earth work etc . complete includingdisposal of surplus earth within a lead of 50 mtr.11104 3.24.1 Inner dia 90 Cm & 10 to 12 Mtr deep. Each 6,026.0011105 3.24.2 Inner dia 60 Cm & 10 to 12 Mtr deep. Each 5,676.0011106 3.25Labour charges for construction of Soakage wellof 90 Cm. dia(Earth – work & its disposal,with ina lead of0.5 Km .only).Mtr 149.0011107 3.26 Add extra if Soakage Well is filled with dry stones. Cum 479.0011108 3.27Construction of septic Tank in all types of soilwith 40 Cm .thick masonry in CM1:6, 15 Cmthick C.C bed of1:5:10,M-15 grade C.C floor &RCC slab covering with M15 grade c.c. floor, 50mm thick stone slab partition walls, 20 mm thickplaster in CM1:6 finished with neat floatingcement, 4 Nos stone foot rests of approveddesign,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as perapproved drawing including disposal of surplusearth within a lead of 50 mtr:-11109 3.27.1Size 200x100x130 cm.(for 10 users) with 115mm thick RCC(M-20) slab Each with Tor steelreinforcement8mm ?@15 cm c/c bothwaysincluding shuttering complete in all respect.29,306.0011110 3.27.2Size 230x110x150 cm.(for 20 users) with 115mm thick RCC(M-20) Each slab with Tor steelreinforcement 10mm ?@15 cm c/c bothwaysincluding shuttering complete in all respect.40,606.0011111 3.27.3Size 400x140x150 cm.(for 50 users) with 115mm thick RCC(M-20) Each slab with Tor steelreinforcement 10mm ?@15 cm c/c bothwaysincluding shuttering complete in all respect.Depth-18 % each63,400.0011112 3.28Emptying of Septic tank,Soakage well etc. bydisposing or sludge upto 5 Km. lead & taking outsewage including cleaning of site.Cum 343.0011113 3.29Add extra if R.C.C slab of designed thickness &reinforcement is provided on manhole in place ofstone slab( Actual area of R.C.C slab to bemeasured).Sqm 258.0011114 3.30P & F M.S. Foot Rests in with C.M.,1:3, standarddesign in 20mm square M.S. bar 50 mmembedded in wall & 10 cms. projected outcomplete.Each 253.0011115 3.31 Supplying and fixing C.I. Cover with frame, C.I.gratings for chambers & man holes. Kg. 76.0011116 3.32 Supplying and fixing Ferro- cement cover withC.I. frame for chambers & man holes of size.11117 3.32.1450mm dia,5Kg.C.I. frame to with stand 3 MTcenter point load & minimum unfractured load of1 MT.(Light duty).Each 1,361.0011118 3.32.2 500mm dia 12 Kg.-do-15 MT centre point load(medium duty).Each 2,622.0011119 3.32.3 500mm dia 22 Kg.-do-22 MT centre point load(Heavy duty).Each 4,209.0011120 3.32.4 500mm dia 25 Kg.-do-70 MT centre point loadseal type(Heavy duty.)Each 4,562.0011121 3.32.5Rectangular shape 600 x 450 mm, to withstand 3MT center point load & minimum unfractured loadof 1 MT.(Light duty).Each 1,417.0011122 3.33 Supplying & Fixing R.C.C. Manholes covers withframe of approved make (Light duty).11123 3.33.1 Size 500mm dia(Double seal) Each 355.0011124 3.33.2 Size 450mm dia Each 315.0011125 3.33.3 Size 400mm dia Each 237.0011126 3.33.4 Size 600 X 600mm(Double seal) Each 542.0011127 3.33.5 Size 600 X 450mm Each 455.0011128 3.33.6 Size 450 X 450mm Each 345.0011129 3.33.7 Size 300 X 300mm Each 107.0011130 3.33.8 Size 250 X 250mm Each 87.0011131 3.33.9 Size 180 X 180mm Each 79.0011132 3.41.6 150mm with door(i) Bend(ii) Door Cross Each2989.00(iii) Tee Each 2164.00 Each 1,509.0011133 3.42Providing and Fixing Spun–Cast Iron floor trap(Nahani) of(IS :3989 Mark) approved quality /make with socket down or hinged gratingincluding cutting and making good the floor :-11134 3.42.1 Size 100 x 100 mm Each 1,031.0011135 3.42.2 Size 100 x 75 mm Each 782.0011136 3.43Add 10% extra Over Item No.3.41 if the pipesare laid under suspended condition under theroof. 11137 3.44Providing and Fixing Unplasticized Poly VinylChloride(UPVC) SWR Pipes Type B for scilandwaste discharge system(IS:13592 : 1992Marked) of approved quality/make11138 3.44.1 75 mm dia Mtr. 172.0011139 3.44.2 110 mm dia Mtr. 346.0011140 3.45Providing and Fixing Unplasticized Poly VinylChloride(UPVC) SWR Pipes fittings type B forsciland waste discharge system(IS:13592 : 1992Marked) of approved quality/make11141 3.45.1 Coupler(i) 75mm dia(ii) 110mm dia Each 114.00 Each 76.0011142 3.45.2 Repair Coupler(i) 75mm dia(ii) 110mm dia Each132.00 Each 80.0011143 3.45.3 Single Push Fit Coupler(i) 75mm dia(ii) 110mmdia Each 135.00 Each 77.0011144 3.45.4 Bend 87.5 Dg.(i) 75mm dia(ii) 110mm dia Each164.00 Each 100.0011145 3.45.5 Bend 45 Dg.(i) 75mm dia(ii) 110mm dia Each140.00 Each 83.0011146 3.45.6 Door Bend 87.5 Dg.(i) 75mm dia(ii) 110mm diaEach 205.00 Each 132.0011147 3.45.7 SingleY(i) 75mm dia(ii) 110mm dia Each295.00 Each 153.0011148 3.45.8 SingleY with Door(i) 75mm dia(ii) 110mm diaEach 369.00 Each 198.0011149 3.45.9 DoubleY(i) 75mm dia(ii) 110mm dia Each374.00 Each 208.0011150 3.45.10 DoubleY with Door(i) 75mm dia(ii) 110mm diaEach 485.00 Each 316.0011151 3.45.11 Socket Plug(i) 75mm dia(ii) 110mm dia Each76.00 Each 66.0011152 3.45.12 Pipe Clip(i) 75mm dia(ii) 110mm dia Each 33.00 Each 19.0011153 3.45.13 Double tee with Door(i) 75mm dia(ii) 110mm diaEach 606.00 Each 354.0011154 3.45.14W.C. Connector 110mm dia Each 229.0011155 3.45.15W.C. Connector(Bend) with ring 110mm dia Each 240.0011156 3.45.16 Single Tee(i) 75mm dia(ii) 110mm dia Each223.00 Each 127.0011157 3.45.17 Single Tee with Door(i) 75mm dia(ii) 110mm diaEach 256.00 Each 144.0011158 3.45.18 Double Tee(4 Ways)(i) 75mm dia(ii) 110mm diaEach 389.00 Each 225.0011159 3.45.20 Offset 110mm dia Each 299.0011160 3.45.21 Extra Square Jali 110mm dia Each 39.0011161 3.45.22 Extra Round Jali 110mm dia Each 28.0011162 3.45.24 Gully Trap 110mm dia Each 726.0011163 3.45.25 Nahni Trap with Jali4” 110mm dia Each 181.0011164 3.45.26 Nahni Trap without Jali4” 110mm dia Each 161.0011165 3.45.27 Nahni Trap with Jali3” 75 mm dia Each 162.0011166 3.45.28 Nahni Trap without Jali3” 75 mm dia Each 143.0011167 3.45.30 Vent Cowel 110mm dia
|