Tender for Providing And Fixing Of Ro, Water Cooler, Desert Cooler, Jumboo Cooler, Ac And Refrigeretors And Various Fans For Cardiology Building And Super Speciality Building, Udaipur (Rate Contract Two Year Estimate Cost 08.00 Lakh) , Supply Installation Testing and Commissioning of Ro Water System With Filteration Stages = Particilate Filter- Membrane Life Enhancer Filter- Sediment Filter- Pre Carbon Filter- Ro Membrane Filter- Post Carbon Filter. Input Power Rating -230V Ac, 50Hz, Percentage Of Rejection Tds-90% Or Better, Having Following Features (A) Double Purification By Ro With Ess Or Latest Technology With Tds Indicator. (B) Spin Welded Ro Membrane Housing To Prevent Tempering. (C) Push Fit Component For Leak Proof Performance. (D) Fully Automatic Operation With Auto Start And Auto Off. (E) Ss/Abs Construction For Corrosion Free Lifespan. (F) Equally Suitable For Water From All Borewells, Overhead Storage Tanks, Water Tankers And Even Municipal Taps. (G) Ro Membrane Flushing - Auto Flush@ Every Start, Every Stop And Every One Hour Of Working For One Minute, Complete In All Respect With Following Capacity. , Purification Capacity - 50Lph, Duty Cycle 270-500 Liters/Day , Purification Capacity - 25Lph, Duty Cycle 170-250 Liters/Day , Production Capacity- 15 Lph, Water Storage Capacity 8 Ltr , Supply , Installation, Testing And Comissioning Of Is:1475 Marked Self Contained Drinking Water Cooler With Hermetically Sealed Compressor,Non Cfc Refrigerent Suitable For Operation On 230V/1Ph/50Hz Ac Supply,Full Stainless Steel (Ss304)Body (0.8 Mm Thick) And Tank (0.5 Mm Thick) , Stainless Steel Water Tray,Minimum Two Nos Brass Chrome Plated Faucets And Suitable Drainage System Complete In All Respect With Required Height Ms Fabricated And Painted Angle Iron Frame ( Cost Of Frame To Be Paid Extra )Complete In All Respect Of The Following Capacity. , Cooling Capacity 150 Ltr./Hr. And Storage Capacity 150 Ltrs , Cooling Capacity 60 Ltr./Hr. And Storage Capacity 120 Ltrs , Cooling Capacity 40 Ltr./Hr. And Storage Capacity 80 Ltrs , Supply And Fixing Of Desert Cooler Having Cooling Capacity Of 5000 Cum/Hr., Approx. Size Of Cooler Is 28X28X38 And Having Tank Of 9 Height With 20 1400 Rpm Heavy Duty Fan Motor And Required Size Of Submersible Pump And All Other Required Accessories. Cooler Should Be Made Of 18 Swg Gi Sheet For Tank And Remaining Cooler Body Should Be Of 20 Swg Gi Sheet, Grill Of Size 22X25 Including Required Size Angle Iron Stand Duly Painted With 2 Coats Of Red Oxide And One Coat Of Enamel Paint Complete In All Respect As Required. , Providing & Fixing Of 450 Mm Sweep Oscillating Type Wall Mounting / Pedestal Type Fans With Three Speed, On And Off Position, Sintered Iron Bush Oil Impregnated, With Metal Front And Back 120 Or More Ribs Guard; Three No. Aluminium Blades, Minimum Air Delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./Min/Watt, Noise Level Should Be = 75 Db, Power Consumption = 120 Watts, Motor Protection Through Thermal Overload Protection Device, Including Fixing With Anchor Bolts, Making Connection Testing Etc. As Required. , Pedestal Type With Adjustable Height , Providing & Fixing Of Wall Mounting / Pedestal Type Heavy Duty Air Circulator , Double Ball Bearing And With Metal Sturdy Mesh Guard; Aluminium Alloy One Piece Blade And Conforming To Is:2997, Including Fixing With Anchor Bolts, Making Connection Testing Etc. As Required. , 450 Mm Sweep Wall Mounting And Three Speed Regulator With Minimum Air Delivery 150 Cum. / Minute , 600 Mm Sweep Wall Mounting With Minimum Air Delivery 270 Cum. / Minute , Providing & Fixing Of Heavy Duty Capacitor Start, Copper Wound Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan Conforming To Is:2312 Marked In Existing Opening Including Making Connections Testing Etc. As Required. , 300 Mm Sweep(900 Rpm) , Providing & Fixing Of Of Double Ball Bearing, Copper Wounded Capacitor Start Single Phase Metallic Blade Fresh Air Fan, In Existing Opening Including Cost Of Hardware , Flexible 3 Core 1.5 Sq.Mm Copper Conductor ,Making Connections, Testing Etc. As Required. , 230 Mm Sweep, Minimum Air Delivery 750 Cum / Hour , 300 Mm Sweep Minimum Air Delivery 1600 Cum / Hour , Providing & Fixing Of Bee Star Rated Copper Wounded With Class Of Insulation F, Double Ball Bearing Capacitor Start, Aluminium Body & Aluminium Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 With Down Rod Up To 30 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin, Shackle Kit With 3 X 1.5 Sq.Mm Pvc Insulated Flexible Copper Conductor And Making Connection Testing Etc. As Required. , 1200 Mm Sweep Bee 1 Star Rated (Service Value =4.0 To 4.5 ) , Providing & Fixing Of Ventilating Fans Capacitor Start, Copper Wounded, Single Phase With Pvc Impeller, Abs Body, Automatic Openable Louver Shutter In Existing Opening Including Making Connection, Testing Etc. As Required. , 150 Mm Sweep Minimum Air Delivery 150 Cum / Hour , 200 Mm Sweep Minimum Air Delivery 450 Cum / Hour , 250 Mm Sweep Minimum Air Delivery 750 Cum / Hour , Supply , Installation, Testing And Commissioning Of Inverter Type Air Cooled Hi Wall Split Type Air Conditioners With Latest Star Rating System As Per Bee Amended Upto Date Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 230V +/- 10% With Low & High Voltage Cutoff And 50 Hz , Single Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotary Compressor. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Of Both Compressor And Printed Circuit Board (Pcb). , Cooling Capacity 3400-3500 Watt, Iseer Not Less Then 3.8 , Cooling Capacity 3400-3500 Watt, Iseer Not Less Then 4.6 , Cooling Capacity 5000-5300 Watt, Iseer Not Less Then 3.8 , Cooling Capacity 5000-5300 Watt, Iseer Not Less Then 4.6 , Cooling Capacity 6200-6350 Watt, Iseer Not Less Then 3.8 , Cooling Capacity 6100- 6300 Watt, Iseer Not Less Then 4.6 , Cooling Capacity 6800-7000 Watt, Iseer Not Less Then 3.8 , Supplying And Drawing Flexible / Stranded Bare Copper Conductor, Pvc / Xlpe Insulated, Overall Aluminium Mylar Tape Shielded Atc Drain Wire And Outer Pvc Sheathed Industrial Instrumentation (Shielded)Cables Voltage Grade 300/500 V As Per Bs /En 50288-7 In Existing Surface Or Recessed Pvc/ Ms Conduit/Casing Capping / Cable Tray / Open Duct Making Connections, Testing Etc. As Required. Oem Must Ensure That The Cable Is Tested For Complaince, Either Through Their In House Laboratory Accrediated By Nabl Or By Any Govt. Laboratory Accrediated By Nabl And The Laboratorys Scope Of Accrediation Should Cover The Requirements And Testing Procedure As Per Is:10810. Un Armoured , 4 Core X 2.5 Sq.Mm , Supply, Installation, Testing And Commissioning Of Interconnecting Copper Refrigerant Piping Of Dhe Grade C12200- Astm B68, B75, Chemical Composition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 . For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation % = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present. Duly Insulated With Tubular Elastomeric Nitrile Rubber Fm/Ul Approved With High Water Vapor Diffusion Resistance And Low Thermal Conductivity Should Be Certified Class O In Fire Propagation As Per Bs 476 Part 6 With 7 Mil Glass Cloth And 3 Coats Of Anti Uv Paint (On Area Which Is Exposed To Weather) Including Chase Cutting Andfilling With Mortar, Slotted Channel Supports Mounted On 10 Mm Threaded Rod At Suitable Spacing The Exposed Piping Shall Be Wrapped With Glass Woven Cloth And Lag Coating For Vapour Barrier And Weather Protection. Joints Shall Be Covered With Nitrile Rubber Tape Of 3 Mm Thick Complete As Required Of Following Sizes. , 12.7 Mm O.D., Wall Thinkness = 0.8Mm (Insulation - 13 Mm Thick) , 6.4 Mm O.D., Wall Thinkness = 0.8Mm (Insulation - 13 Mm Thick) , Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drain Water Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket, Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Or Recessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cell Elastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. As Required Of Following Nominal Sizes. , 20 Mm , Supply, Fixing And Testing Of Following Capacity Is:8448 Marked Wall Mounted Stabilizer Having Output Voltage Variation From 200 V To 250 V(+/-5%) With Input Voltage Variation From 170 V To 260 V, Time Delay Facility From 2 To 4 Minute And High Cutoff At 270 V With Providing Of 16 annual periodical maintenance /20 annual periodical maintenance Industrial Plug Top Making Connection Etc Complete In All Respect. , 3 Kva , 4 Kva , 5 Kva , Making Hole In Stone Masonary/ Reinforced Cement Concrete Wall/ Reinforced Cement Concrete Slab With Core Cutter For Accomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Of Following Dia , 50 Mm Dia Per Running Inch Length , Supply & Fixing Ms Powder Coated Stand Suitable For 1.0/1.5/ 2.0 Tr Outdoor Type Of Split Ac. All As Per Pre Approved By Engineer In Charge. , Supply & Fixing Ms Powder Coated Stand Suitable For 2.5/3.0/4.0 Tr Outdoor Type Of Split/Ductable/Tower Ac. All As Per Pre Approved By Engineer In Charge. , Providing & Fixing Of Jumbo Cooler 150Ltr To 200 Lts Water Tank Capacity, Moter Copper Wounded , Providing & Fixing Of Various Capacity Inverter Technology Based 3 Star Refrigerator. , 180 Lts ( Appro. Capacity) Single Door , 230 Ltrs( Appro. Capacity) Double Door , 250 Ltrs( Appro. Capacity) Double Door , 300 Ltrs( Appro. Capacity) Double Door , 330 Ltrs( Appro. Capacity) Double Door , 350 Ltrs( Appro. Capacity) Double Door , 400 Ltrs( Appro. Capacity) Double Door , 450 Ltrs( Appro. Capacity) Double Door
|