|
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - 132 Kv Substation Indira Nagar; Electrical System Or Installation; Service Provider - Part A (Supply) , 50 Ltr Mechanical Foam Type Wheel Mounted Extinguisher , Manual Dry Chemical Fire Extinguisher , Manual Carbon Di Oxide Fire Extinguisher 22.5 Kg , Sand Bucket , Sand Bucket Stand Suitable 10 No Sand Bucket , Phase Plate , Copper Bond , Safe Carriage Of The Following Equipments Including Loading And Unloading On Trucks Duly Arranged By The Contractor From Stores Of Different Sub-Station Of Lucknow To 132 Kv Sub-Station Indira Nagar, Lucknow. , Erection Of Main And Auxiliary Structures , Erection Of Following Equipments As Per Instruction Manual And Technical Specifications Including Shifting Of Materials From Central Stores To Erection Site Including All Associated Works. , Jumpering Of Various Equipments With Twin Acsr Panther Conductor In After Due Cutting And Bending Of Conductor And Fixing & Tightening Etc Of The Conductor/ Cl S/Connectors/Spacers Etc. , Laying Of Following Sizes Control Cables In The Cable Trenches From Control And Relay Panels In Control Room To Various Equipments, Junction Box Etc. In Swithcyard As Per Cable Schedule, Its Sddling With 25X3 Mm Size Including Carriage Of Cable Drums From Stores To Work Site & Shifting Back To Stores Including Allother Associated Works Required For The Satisfactorily Completion Of The Job As Per Technical Specification. , Interconnection & Termination Of Of The Above Laid Control Cables Between Control And Relay Panels & Erected Equipments I.E. Cb, Ct, Ct Junction Box, Pt, Pt Junction, Box. Including Making Necessary Holes In Gland Plates Or Boxes Whereever Required Along With Supply Of Cable Glands Of Appropriate Size And Providing Of Ferrules For Each Core Of The Cables & Its Termination With Crimping Type Copper Lugs Alongwith Preparation Of Interconnection Drawing And Commissioning Of The Panel/ Feeders In Co-Ordination With T&C Wing Includoing Providing 02 Sets Of Hard Copies Of As Executed Interconnection Drawing Including All Other Associated Works Required For The Satisfactorily Completion Of The Job As Per Technical Specification. , Cutting, Straightening And Laying 700 Mm Below Inside Ground & Above Ground Of 75X10 Mm,50X6 Mm, 25X6 Mm Size M.S. Flats (To Be Provided By The Department) As Per Requirement For Earthing Of Newly Erected Equipments And Structures As Above Including Welding With Main Earthmat And With The Object To Be Earthed Including Excavation, Backfilling, Painting Of The Earthmat Above Groung Level In Bus Green Colour Including All Other Associated Works To Complete The Job Satisfactorily As Per Technical Specifications. , Painting Of Earthing Strips Above Ground Level With One Coat Of Red Oxide And Two Coat Of Synthetic/ Enamel Paint And With Black Bitumen Paint Below Ground Level As Per Details Below: , Following Works Are To Be Carried Out For Integration Of 01 No. 33 Kv Bay With Existing Siemens Make Scada System And All Associated Works At 132 Kv Sub Station Indira Nagar, Lucknow With All Cost Of Men, Misc. Consumables, T&P Etc. To Complete The Job Satisfactorily As Perdirection Of The Supervising Engineer: , Supply & Fixing Of 160 Watt Led Street Light Luminaries (Outdoor Type) Of Philips / Crompton Greaves / Havells / Bajaj Make In Single Piece Aluminium Die Cast At Designated Height On Gantry Beam On G.I. Light, Bracket Including Guiding The Cable To Light Fixtures From Inside Pipe/Bracket, Cable Terminations And Its Testing And Commissioning And Earthing With 12 Swg Wire , Supply & Fixing Of Of Gi Light Bracket Duly Made Of 54 Mm Dia, Suitable For 1.2 Meter Long B Class Gl Pipe And Bent At One End By Quarter Circle In 1.0 Meter Length At An Angle Of 30 Degrees For Fixing 160 Watt Led Light Fitting On Gantry With The Help Of Gi/M.S. Cl S As Required (01 Job Per Light). , Supply & Fixing Of Lighting Junction Box Of Size 280X225x150 Mm Duly Made Of 16 Swg M.S. Bp Sheet And Paintedwith Smoke Grey Colour Synthetic Enamel Paint Duly Fitted With 01 No. 6 Sp Mcb On Anodized Ms. Channel , Supply & Fixing Of Outdoor Type 03 Phase Ac Cubical Boxes Of Size 1200X600x300 Mm Duly Painted With One Coat Of Red Oxide Primer And Two Coat Synthetic Enamle Smoke Gray Paint With 04 No Aluminium Isulated Bus Bar For Connecting Acdb And Fitted With 01 No 100 Mccb Along With Three No (03) 3-Phase Mccb Of Rating 32A, 09 No, 3 Phase Mccb Rating 16A, 03 Nos 1 Phase Mccb Of Rating 6A Havels Make . The Cubical Box Should Be Made Of 16 Swg Ms Sheet In The Double Shutter With Indoor Loacking Arrangment Complete With Proper Size Wire Tbs For Incoming Terminals And 18 Nos Tbs For Outging Terminals Of Standerd Size And Rating . Proper Fixing Installation & Testing And Commissining Of Above Cubical Box Including All Civil And Other Associated Works , Laying Of Power Cable Of Size 3.5X50/95 Mm Between Main Acdb To Ac Cubicle Box If Required After Exacavation Of Trench Laying The First Class Brick Lining .Filling Of River Sand Along And Over The Cable Then Back Filling And Leveling The Trench After The Cable . The Work Also Includes Termination Of Cable On Both Side With Crimping Of Lugs . , Supply & Fixing Of Name Plates Made Of 2 Mm Thick Aluminium Sheet Covered With 3M Hip Retro Reflective Sheet Of Following Size With Details/Name Written As Per Prescribed Colour Scheme To Be Fixed With The Help Of Nuts And Bolts At Already Installed Equipments Structures In The Switchyard With All Cost Of Plates, Nut & Bolts, Misc.Materials Like Chains In Case Of Breakdownshutdown Plates Etc., T&P And Labour As Per Technical Specificaions & Direction Of The Concerned Supervising Engineer:
|