Tender For Purchase Of Equipment , Single Station Glove Box , Stainless Steel Vacuum Glove Box For Battery Research And Fabrication With Purification System - 1 No. With Following Minimum Technical Specification: Equipment Type: Fully Automatic Two-Port Inert Atmosphere Glove Box With Gas Purification System, Application: Fabrication And Assembly Of Lithium-Ion/Na-Ion Battery Cells, Solid-State Batteries, Air-Sensitive Materials, Chamber Material: Ss 304 Stainless Steel, Chamber Construction: Fully Welded Leak-Tight Construction, Chamber Dimensions: Minimum 1200(L) × 750(W) × 900(H) Mm, Internal Finish: Mirror Polished/Electropolished, Front Window: Tempered Safety Glass Or Polycarbonate, Leak Rate: Better Than 0.05 Vol %/H, Glove Ports: Two Ports, 220 Mm Diameter, Glove Port Seal: Double O-Ring Sealing, Gloves: Butyl Rubber, 0.4 Mm Thickness, Internal Shelves: Ss304 Removable Shelves, Vacuum Gauge: Digital Display, Pressure Control: Automatic Pressure Regulation (±15 Mbar), Data Logging: Oxygen, Moisture, Pressure And Regeneration History Gas Purification System: Purification Principle: Closed-Loop Gas Recirculation, Moisture Level: 1 Ppm, Oxygen Level: 1 Ppm, Purification Capacity: Oxygen = 35 L, Moisture = 1300 G, Blower: Variable Speed Blower (Minimum 80 M3/H), Regeneration: Fully Automatic, Regeneration Gas: N2/H2 (95/5) Or Ar/H2, Regeneration Sequence: Plc Controlled Automatic Regeneration, Moisture Sensor: 0.01-1000 Ppm, Oxygen Sensor: 0.1-1000 Ppm, Sensor Display: Continuous Digital Display Gas Circulation:Working Gas: Nitrogen/Argon, Gas Circulation: Closed-Loop Automatic Circulation, Gas Purifier: Integrated, Gas Analyzer: Integrated O2 And H2O Analyzers, Automatic Purging: Required, Automatic Pressure Control: Required Main Antechamber:Type: Cylindrical, Size: Minimum 390 × 600 Mm, Material: Stainless Steel, Leak Rate: Better Than 10-4 Mbar L/S, Sliding Tray: Stainless Steel, Door Material: Anodized Aluminum, Vacuum/Refill: Automatic Plc Controlled, Pressure Gauge: Digital Mini Antechamber:Size: Minimum 150 × 400 Mm, Leak Rate: Better Than 10?4 Mbar·L/S, Material: Stainless Steel, Vacuum/Refill: Manual/Automatic,Pressure Gauge: Digital Vacuum System:Pump Type: Double-Stage Rotary Vane Vacuum Pump, Pumping Speed: Minimum 40-50 L/Min, Ultimate Vacuum: Better Than 0.02 Mbar, Oil Mist Filter: Included, Vacuum Hose: Included , Isolation Valve: Included Safety Features: Automatic Pressure Protection: Yes, Automatic Regeneration: Yes, Automatic Purging: Yes, Oxygen Alarm: Yes, Moisture Alarm: Yes, Emergency Stop: Yes, Power Failure Protection: Yes, Glove Leak Alarm: Preferred Accessories To Be Supplied: Vacuum Pump, Gas Purification Unit, Moisture Analyzer, Oxygen Analyzer, Plc Controller, Touch Screen Hmi, Power Feedthrough, Kf Feedthrough Ports, Two Pairs Of Butyl Gloves, Vacuum Hose Set,Gas Connection Kit, Operation Manual, Tool Kit, Calibration Certificate Terms And Condition: Warranty: 2 Year Warranty + 1 Year Annual Maintenance Contract Installation & Commissioning: The Instrument Should Be Installed, Tested And Commissioned By A Representative Of The Supplier. A Full Installation Kit And Operational Manual Should Be Required. Supply & Shipment: The Company Should Take Care Of Delivery Upto The Doorstep @ Department Of Nanoscience And Technology, Bharathiar University, Coimbatore 641046
|