Tender For Certain B/R & Electrical And Mechanical Sanctioned Works Under Ge (I) (Cg) Ratnagiri.- 1 Material And Labour For 18 Mm Thick Plywood, Grade Bwp Type Bb Having Minimum 7 Nos Of Ply, Fixed With Screws To Timber Frame Work To Clamps Wherever Necessary Etc, Complete All As Specified And Directed. 2 Material And Labour For 09 Mm Thick Plywood, Grade Bwp Type Bb Having Minimum 05 Nos Of Ply Fixed With Screws To Timber Frame Work To Clamps Wherever Necessary Etc. Complete All As Specified And Directed. 3 Material And Labour For 0.9 Mm Thick Decorative Laminated Sheet Type 1 Of Surface Finish Coloured And Pattern As Approved And Fixed Over Plywood With Approved Adhesive, Complete All As Specified And Directed. 4 Material And Labour For Plain Fillets Of 2Nd Class Hard Wood Area Not Exceeding 3 Sqcm For Cupboard, Wardrobe And Door, Including Clean, Sawn, Res-Ecured With Nails Or- Brads, Complete All As Specified And Directed. 5 Material And Labour For Plain Fillets Of 2Nd Class Hard Wood Area Exceeding 3 Sqcm But Not Exceeding 6 Sqcm Bull Nosed Splayed, Chamfered Or Rounded On One Edge Or Face, For Cupboard, Wardrobe And Door Including Clean, Sawn, Re-Secured With Nails Or- Brads, Complete All As Specified And Directed. 6 Material And Labour For Varnishing Of Plain Fillets, Not Exceeding 10 Cm In Width Or Girth When Unconnected With Other Work Or Painted In Different Tint With One Coat Of Wood Filler Liquid Transparent And With Two Coats Of Synthetic Varnish Including Preparation Of New Or Previously Treated Surfaces Etc, Complete All As Specified And Directed. 7 Supply And Fixing Of Extruded Brass Handles, Fabricated Type, Polished Bright 150 Mm Long All As Specified And Directed. 8 Supply And Fixing Of Extruded Brass Handles, Fabricated Type, Polished Bright 300 Mm Long All As Specified And Directed. 9 Supply And Fixing Of Butt Hinges Of 125 Mm, Extruded Brass, With Mild Steel Hinge Pin, Bright Polished And Fixed, Type B-11 Complete All As Specified And As Directed. 10 Supply And Fixing Of Sheet Glass 5.5 Mm Thick And Glazing With Provided With Aluminum Cleats For Securing In Squares Exceeding 0.5 Sqm In Each Pane, Complete All As Specified And Directed. 11 Supply And Fixing Of Gl Frame Work For Seamless Ceiling Comprising Of Gl Perimeter Channel 0.55Mm Thick With Two Unequal Flanges Of 20 And 30Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleeves And Screws At 450Mm Centre To Centre/Intermediate Channel 0.9Mm Thick Having Equal Flanges Of 15Mm Each And Web Of 45Mm Suspended From Soffit At Approximate 900Mm Center To Centre With Gl Cleat And Steel Expansion Fasteners With And Including Ceiling Section (Not Exceeding 1.2 Meters Length) Of 0.55Mm Thickness Having Knurled Web Of 50Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel At 457Mm Centre To Centre, Complete All As Specified And As Directed. 12 Supply And Fixing Of Hangers 4Mm Dia Gl (Up To 1200Mm Length) Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gl Flat 40 X 3Mm Size 60Mm Long And Expansion Hold Fasteners 12.5Mm Dia, 40Mm Long Complete All As Specified And As Directed. 13 Supply And Fixing Of Pvc Insulation Panels With Eps Stuck To 1Mm Printed Pvc Sheet Suitably Placed In False Ceiling Grid Made Of Aluminum/G.I./M.S. As Per Specification And Drawing But Without Relevant Pvc Insulation Panel Complete All As Specified And As Directed. 14 Supply And Fixing Of Solid Pvc Wall Lining Consisting Of 5Mm Thick Plain Colour Pvc Sheet Inclusive Of Solvent Cement And Fixing At Site On Pvc Frame As Per Specifications And Drawing Complete All As Specified And As Directed. 15 Material And Labour For Pre-Cast Cement Concrete Type C1 1:3:6 (20Mm Graded Aggregate) Block Masonry With Solid Blocks Exceeding 10Cm In Width And Setting In 1:6 Cement Mortar, Complete All As Specified And As Directed. 16 Material And Labour For Rendering 15Mm Thick In Cement Mortar 1:4 On Brick Work Or Concrete Surfaces Or Surface Other Than Fair Face Of Brick-Work Or On One Side Of Lathing Finished Even And Smooth (Without Using Extra Lime Or Cement) Complete All As Specified And As Directed. 17 Taking Down Copper/Aluminium Point Wiring (Light, Fan, Socket Or Power) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting Etc. Removing Materials To Store For Keeping In Safe Custody And Making Good Disturbed Surfaces Of Walls, Floors, Etc Complete All As Specified And As Directed. 18 Taking Down The Existing Serviceable Db/Energy Meter Any Type/Capacity Description As Per Existing At Site And Refixing After Completion Of Wall Paneling Including Making Good Disturbed Surfaces Of Wall To Match With Existing Surfaces Complete All As Specified And As Directed. 19 Disconnecting The Electrical Connection Wall Mounted Fan Sealing Cable End And Refixing At Existing Position Making Good To The Disturbed Surfaces Of Walls/Floor/Shed Etc To Match With Existing Surfaces Including White Washing/Colour Washing/Distempering To Match With Existing Wall/Floor/Ceiling Finishes, For Reuse At Site Complete All As Specified And As Directed. 20 Taking Down Carefully By Unscrewing From Boards/ Outlet Boxes, Fittings And Fixtures Such As Switches, Sockets, Ceiling Roses, Lamp Holders, Brackets, Ceiling Fittings, Bulk Head Fittings, Tube Light Fittings And Regulators, Etc. For Reuse At Site Or Carrying To The Store (To Be Measured Only When Found Serviceable In All Respects Complete For Reuse) Complete All As Specified And As Directed. 21 Material And Labour For Point Wiring With Pvc Insulated Unsheathed Frls Stranded Copper Conductor Cable Of Size 1.5 Sqmm, With Pvc Insulated Unsheathed Stranded Copper Conductor Cable Of Size 1.5 Sqmm Stranded For Earth Continuity Wire, To Be Drawn In And Including, Pvc Medium Grade Conduit/Casing Capping With Suitable Size Concealed In Walls/Roof/Floors With Ms Sheet Metal Sunken Modular Switch/Terminal Box 1.0 Mm Thick And Modular Plate And Brass Screws With Cup Washers For One Light Controlled By One, One Way Switch Complete All As Specified And As Directed.Note:-(1) Rate Is Inclusive Of Cutting/Chases Of Wall/Floor/Ceiling. 22 Ditto As Per Item No 21 But For One 3 Pin 5 Amps Socket Out Point On The Same Board With Other Switches Complete All As Specified And As Directed. 23 Ditto As Per Item No 21 But Forone 3 Pin 5 Amps Socket Out Let Point On Independent Board Complete All As Specified And As Directed. 24 Supply And Fixing In Replacement Of Modular Switch 1 Way 10 Amps,1 Module Complete All As Specified And As Directed. 25 Supply And Fixing In Replacement Of Socket, 5/6 Amps - 2/3 Pin Combined 2 Module Complete All As Specified And As Directed. 26 Supply And Fixing Round Shape Led Ceiling Light 15 Watt 220 Volts Ac Recessed Type With High Efficiency Pmma Diffuser Soft Glare Free Light Complete With Drivers, Holders, Led Lamp Suitable For Roof Ceiling Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size Complete All As Specified And As Directed. 27 Supply And Fixing Of Decorative Wall Light Made Up Of High Grade Engineering Plastic Material Suitable For 9 Watts Led Lamp B22 Base Complete All As Specified And As Directed. 28 Supply And Fixing Of Decorative Wall Light Made Up Champagne Gold Finish Fixture With Plastic Body Suitable For 9 Watts Led Lamp B22 Base Complete All As Specified And As Directed. 29 Supply And Fixing Of Flexible Led Strips 24 Watt Per 5 Meter With Uniform Light Distribution And Long Lasting Adhesive For Perfect Cove Lighting Solution Led Strip 6000/4000K Including Driver Complete All As Specified And As Directed. 30 Supply And Fixing In Replacement Of Mcb Db Made Of Sheet Steel , Powder Painted With Nutral Bus Bar Suitable Rating, Neutral Link, Earth Bar And Din Rail ,240Volts Spn With 12 Way Double Door , Ip-43-Ik09 Protection Grade Complete All As Specified And As Directed. 31 Supply And Fixing Of Mcb Spn 40 Amps 240 Volts, C Series, Breaking Capacity 10 Ka Complete All As Specified And As Directed. 32 Supply And Fixing Of Mcb Sp 6-32 Amps 240 Volts, C Series, Breaking Capacity 10 Ka Complete All As Specified And As Directed. 33 Material And Labour For Sub Main Wiring Power/Circuit Using Pvc Insulated Unsheathed Frls, Stranded Copper Conductor Cable 2 Single Core Of Size 6 Sqmm, Earth Continuity Conductor Of Size 6 Sqmm To Be Drawn Through In And Including Pvc Casing Capping In Walls/Roof/Floors All As Directed By Engineer In Charge. Note:- 3 Wires Of 6 Sqmm And Pvc Casing Capping Shall Be Measured As One Unit. 34 Material And Labour For Sub Main Wiring Power/Circuit Using Pvc Insulated Unsheathed Frls, Stranded Copper Conductor Cable 2 Single Core Of Size 2.5 Sqmm, Earth Continuity Conductor Of Size 2.5 Sqmm To Be Drawn Through In And Including Pvc Casing Capping In Walls/Roof/Floors All As Directed By Engineer In Charge. Note:- 3 Run Of 2.5 Sqmm And Pvc Casing Capping Shall Be Measured As One Unit. 35 Supply And Installation Of Fast Earth Electrode 3.0 Meter Length Size Model F84, Having Two M S Pipe One Inside The Other With Proper Not Deep Galvanized Outer Dia 88 Mm And Inner Dia 48 Mm And The Cavity Between The Rod Pipes Is Filled With Ground Resistance Improvement Powder, Sealed With Both En Outer Pipe Of Electrode Should Be Zinc Coated, The Electrode Should Buried Directly In The Ground By Making Boring Of Diameter 10\ With Boring Machine Highly Conductive Nonmagnetic And Non-Corrosives Is To Be Connected With Gi Wire 4 Mm To Facilitate Further Connection To Earth Dolly And Provision Of Earthing Chamber In Bricks Wall Size 45X45X15 Cm An Having Pcc Cover Of Required Size Complete All As Directed And All As Per Is 3034 (1981) Note:-Gi Wire To Be Measured And Paid Separately. 36 Material And Labour For Steel Tubing Gi Light Grade 40 Mm Dia For Cable Protection Passing Under Road /Floor Or For Fixing To Poles All As Specified And Directed. 37 Material And Labour For Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit/Pipe Or Fixed To Poles Or Any Other Indicated Situation For Loop Earthing Etc,As Required 4 Mm Dia Galvanized Iron Wire All As Specified And Directed. 38 Supply And Fixing Of Vtpn Mcb Db Made Of Sheet Steel Suitable For Flush Mounting And Surface Mounting, With 100 Amps Copper Busbar For Each Phase With 2 Neutral Bar, 2 Earthbar And Cable Ties For Cable Management Fully Insulated Busbar & Shrouded Neutral Bars Reversible Door For Ip 43,415 Volts Tpn 4 Way With Provision For Fp Mcb As Incomer And Sp/Tp McbS As Outgoing Complete All As Specified And As Directed.Note: Rate Includes Mcb Tpn 63 Amps. 39 Supply And Fixing 415 Volts 10Ka C Curve Miniature Circuit Breaker (Mcb) Of Three Poles And Carrying 63 Amps Capacity In The Db Complete With Connection Testing And Commissioning Complete All As Specified And Directed.Note: Rate Includes Connection Of Tp In Existing Vtpn Db. 40 Supply And Fixing Of Insulated Plug & Socket Tpn Enclosure With 3P+N+E, 3 Pole, Neutral And Earth Metal Plug And Socket For Incorporating ,63 Amps Tpn Mcb Complete All As Specified And Directed.Note: 63 Amps Tpn Mcb To Be Measured And Paid Separately. 41 Supply And Fixing Tpn Mcb Of Rating 40 To 100 Amps, 415 Volts, C Curve Miniature Circuit Breaker (Mcb) Of Breaking Capacity 10Ka In Plug & Socket Tpn Enclosure With Connection Testing And Commissioning Complete All As Specified And Directed. 42 Supply And Fixing Of Insulated Plug And Socket Spn Enclosure With 2P+E, 2 Pole, Neutral And Earth Metal Plug And Socket For Incorporating ,32 Amps Spn Mcb All As Specified And Directed.Note: 32 Amps Spn Mcb To Be Measured And Paid Separately. 43 Supply And Fixing Spn Mcb Of Rating 32 Amps, 415 Volts, C Curve Miniature Circuit Breaker (Mcb) Of Breaking Capacity 10Ka In Insulated Plug & Socket 2P+E Enclosure With Connection Testing And Commissioning All As Specified An Directed. 44 Supply And Fixing Of Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Pvc Box Type Complete With One Single Pole Mcb 25 Amps All As Specified And Directed.Note: Price Of Ac Box Include Three Pin Plug And 25 Amps Mcb An There Connection. 45 Material And Labour For Wiring For Circuit/Submain Wiring Along With Earth Wire With The 4X10 Sqmm + 1X10 Sqmm Earth Wire Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed As Required In Pvc Casing Capping Complete All As Specified And Directed. Note: 5 Runs Of 10 Sqmm Copper Wires And Pvc Casing Capping Consider As A One Unit. 46 Material And Labour For Wiring For Circuit/Submain Wiring Along With Earth Wire With The 4X6 Sqmm + 1X6 Sqmm Earth Wire Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed As Required In Pvc Casing Capping Complete All As Specified And Directed At Site By Engineer-In-Charge. Note: 5 Runs Of 6 Sqmm Copper Wire And Pvc Casing Capping Consider As A One Unit. 47 Material And Labour For Wiring For Circuit/Submain Wiring Along With Earth Wire With The 2X4.0 Sqmm +1X4.0 Sqmm Earth Wire Size Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed As Required In Pvc Casing Capping Complete All As Specified And Directed At Site By Engineer-In-Charge. Note: 3 Runs Of 4 Sqmm Copper Wire And Pvc Casing Capping Consider As A One Unit. 48 Supply And Fixing Surface Modular Box Of 6 Way Along With 6 Way Modular Plate And 2 Nos Of 16 Amps Switches And 6/16 Amps Multipurpose Sockets With Connected Internal Wiring Complete All As Specified And Directed. 49 Supply And Fixing Of Gi Tubing Medium Grade (Isi Marked) Size 15 Mm Dia With All Fitting/Accessories For Protection Of Cable On Pole / Wall An Under Road Crossing Including Clamps, Nuts Bolts Etc Complete All As Specified And Directed. 50 Supply And Fixing Of 6 Mm Thick Looking Mirror Designer Type, Beveled Edges, Including Fixing With Studs/ Brackets At Corner And Sides Etc, Complete All As Specified And As Directed.
|