|
Diagnostic Test Strips N-10 Uriners (100 Pcs Per Pack). Test Strips For Urine Analyzers Cl-50, Cl-50 Plus, Cl-500, Dirui H-50, H-100, H-300, H-500. The Strips Are Intended For Laboratory Screening And Individual Patient Monitoring. 10 Parameters:Biochemical Components (Glucose, Protein, Ketones, Nitrites, Bilirubin, Urobilinogen);Blood Cells (Occult Blood, Leukocytes);Physicochemical Parameters (Ph, Specific Gravity).Contents: 100 Pcs/Pack, Plastic Case With Desiccant. Gost Iso 15193-2015 (Department Of Biomedicine), Uric Acid Determination Kit. A Set Of Reagents For Determining The Concentration Of Uric Acid. Test Material: Serum Or Plasma, Urine. Shelf Life Of The Kit: 24 Months At +2...+8 ºс. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), A Set Of Reagents For The Determination Of Cholesterol. A Set Of Reagents For Determining The Concentration Of Total Cholesterol. Test Material: Serum Or Blood Plasma. Shelf Life Of The Kit: 18 Months At +(2-8)°C. Composition: Reagent 1 - 100 Ml, Calibrator - 2 Ml. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Set Of Reagents For The Determination Of Hemoglobin. The Kit Is Intended For Quantitative Determination Of Hemoglobin Content In The Blood. The Kit Is Designed To Carry Out 600 Determinations At A Consumption Of 5.0 Ml Of Working Solution Per Analysis. Set Contents1. Transforming Reagent – Dry Mixture (Sodium Carbonate, 1.0 G; Potassium Iron Sulfide, 200 Mg) – 3 Packs.2. Acetone Cyanohydrin – 3 Ampoules (0.5 Ml Each).3. Hemoglobin Calibration Solution With A Concentration Of 120 G/L – 1 Bottle (2 Ml). The Kit Must Be Stored In The Manufacturers Packaging At A Temperature Of +2–8° C Throughout The Entire Shelf Life. The Kits Can Be Stored At Temperatures Up To +25° C For No More Than 5 Days. The Shelf Life Of The Set Is 2 Years.The Transforming Solution Should Be Transparent, Yellow In Color And Can Be Stored In Dark Glass Containers At Room Temperature For No More Than 6 Months. If Sediment Appears Or Becomes Discolored, The Solution Is Unsuitable For Use. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Kit For Determination Of Creatinine. Set Of Reagents For Determining Creatinine Concentration. Test Material: Serum Or Plasma, Urine. Shelf Life Of The Kit: 12 Months At +(18-25)ºс. Composition: Reagent 1 - 50 Ml, Reagent 2 - 50 Ml, Calibrator - 2 Ml. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Ast Determination Kit. The Kit Is Intended For Determining The Activity Of Aspartate Aminotransferase (Ast) In Serum Or Blood Plasma Using The Unified Dinitrophenylhydrazine Reitman-Frenkel Method. Set Composition: No. 1 Substrate Mixture - 1 × 100 Ml; No. 2 Solution 2,4-Dnph - 1 × 100 Ml; No. 3 Sodium Hydroxide - 1 × 100 Ml; Calibrator - 1 × 5.0 Ml; Linearity: Deviation No More Than 10% In The Activity Range Of 0.067-1.25 Μmol (S×L); Sensitivity: No More Than 0.05 Μmol (S×L); Coefficient Of Variation: No More Than 6%. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Kit For Determination Of Urea. Set Of Reagents For Determination Of Urea Concentration. Test Material: Serum Or Plasma, Urine. Shelf Life Of The Kit: 12 Months At +(2-8)ºс. Composition: Reagent 1 - 60 Ml. Reagent 2 - 20 Ml, Reagent 3 - 20 Ml, Calibrator - 4 Ml. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Albumin Determination Kit. The Reagent Kit Is Intended For The Quantitative Determination Of Albumin In Urine. Set For 200 Tests. Packaging Contents: Box Contains 1 Wedge-Shaped Plastic Bottle With Balls; 1 Wedge-Shaped Plastic Bottle With Reagents, 2 Bottles With Calibrators. Transportation At: +2°С +8°С. Storage Conditions: +2+8°С. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Set Of Reagents For Determination Of Glucose. Diagnostic Kit Glucosa-Vital For The Quantitative Determination Of Glucose In Serum, Blood Plasma Or Urine. Set Contents:Reagent No. 1. Bufferphosphate Buffer, Ph 7.5 – 150 Mmol/Lphenol – 10 Mmol/Lreagent No. 2. Lyophilisateglucose Oxidase – 25000 Units/Lperoxidase – 1500 Units/L4-Aminoantipyrine – 0.16 Mmol/Lcalibratorglucose – 10 Mmol/L. Linearity - From 10 To 120 G/L, Storage Temperature - 20-25°C, Reagent Shelf Life - 18 Months In The Dark. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Azur-Eosin Dye According To Romanovsky. Dye Azur-Eosin According To Romanovsky 1 L. Complete Set + Buffer Solution Concentrate. Ratio: Glycerin-Methanol 1:1. One Liter Of Dye With A Phosphate Buffer Solution Is Designed To Stain Up To 6000 Blood Samples. Gost R Iso 23640-2015 (Department Of Biomedicine), Set Of Reagents For The Determination Of Bilirubin. A Set Of Reagents For Determining The Concentration Of Total And Direct Bilirubin. Test Material: Blood Serum. Shelf Life Of The Kit: 12 Months At +(18-25)°C. Composition: Reagent 1 - 100 Ml, Reagent 2 - 25 Ml, Reagent 3 - 1 Ml, Reagent 4 - 100 Ml, Calibrator - 1 Pc. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Alt Determination Kit. The Kit Is Intended For The Quantitative Determination Of Alanine Aminotransferase (Alt) Activity In Serum And Plasma Using An Optimized Enzymatic Kinetic Method (Ifcc, Without Pyridoxal 5-Phosphate). Kit Contents: Reagent No. 1 - 1 × 40 Ml; Reagent No. 2 - 1 × 10 Ml; Linearity: Deviation No More Than 5% In The Activity Range From 9 To 350 Units/L. Sensitivity: 7 Units/L. Coefficient Of Variation: No More Than 5%. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Total Protein Determination Kit. The Total Protein Agate Diagnostic Kit Is Intended For The Quantitative Determination Of Total Protein Content In Serum Or Blood Plasma.The Kit Is Designed For 400 Determinations With A Consumption Of 5.0 Ml Of Working Solution Of Biuret Reagent Per Analysis.General Protein-Agate (Biuret Method), 400 Samples X 5 Ml., (Calibrator 2 Bottles). Set Contents1. Biuret Reagent, Concentrate (Copper Sulfate – 120 Mmol/L, Potassium Iodide – 300 Mmol/L, Potassium Sodium Tartrate – 320 Mmol/L, Sodium Hydroxide – 3 Mol/L), 100 Ml – 1 Bottle.2. Total Protein Calibration Solution (Bovine Serum Albumin Solution With A Concentration Of 60 G/L With The Addition Of Sodium Chloride 9 G/L And Sodium Azide 1 G/L), 2 Ml - 2 Bottles. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine), Dye Fixative Eosin Methylene Blue. Dye-Fixer Eosin Methylene Blue According To May-Grunwald, 1 L. Designed For Fixing Blood Products And Pre-Staining. Composition: 0.2% Solution Of Eosin And Methylene Blue In Methanol. One Liter Of Fixative Dye Is Designed To Fix At Least 1000 Drugs. Gost R Iso 23640-2015 (Department Of Biomedicine), Calibration Kit For Hemoglobin Determination. The Hemoglobin Calibration Solution Is Intended For Calibration Of The Quantitative Determination Of Hemoglobin In Human Blood Using The Unified Hemiglobin Cyanide Method. Composition: Hemoglobin Solution With A Concentration Of 120 G/L With The Addition Of Ethylene Glycol 30 Vol%, 2.0 Ml - 1 Bottle. Storage And Operation Conditions: The Calibration Solution Should Be Stored In The Manufacturers Packaging At A Temperature Of +2–8° C Throughout The Entire Shelf Life. Storage At Temperatures Up To +25°C Is Allowed For No More Than 5 Days. Shelf Life: 2 Years. To Work On Existing Instruments: Spectrophotometer Pd-303 And Photometer Kfk-3 Zomz. Gost Iso 15193-2015 (Department Of Biomedicine)
|