Bids Are invited for Refer Soq Sh-I, Item No. 1. Sitc Of Dg Set. , Refer Soq Sh-I, Item No. 2. Providing, Fixing, Testing And Commissioning Of Exhaust Piping For Dg Set Exhaust System. , Refer Soq Sh-I, Item No. 3. Sitc Of Diesel Fuel Tank Of Suitable Capacity For 200 Kva Dg Set. , Refer Soq Sh-I, Item No. 4. Sitc Of Outdoor Type Amf Cum Essential Lt Panel. , Refer Soq Sh-I, Item No. 5. Sitc Of Retrofit Emission Control Devices For Dg Sets. , Refer Soq Sh-Ii, Item No. 1. Earthing With Gi Earth Plate 600Mm X 600Mm X 3Mm Thick Including Accessories. , Refer Soq Sh-Ii, Item No. 2. Providing And Fixing Of 25Mm X 5Mm Gi Strip In 40Mm Dia. G.I. Pipe. , Refer Soq Sh-Ii, Item No. 3. Providing And Fixing Of 25Mm X 5Mm Gi Strip On Surface Or Recess For Earth Connection. - Refer Soq Sh-Ii, Item No. 3. Providing And Fixing Of 25Mm X 5Mm G.I. Strip On Surface Or Recess For Earth Connection As Required. , Refer Soq Sh-Ii, Item No. 4. Earthing With Copper Earth Plate 600Mm X 600Mm X 3Mm Thick Including Accessories , Refer Soq Sh-Ii, Item No. 5. Providing And Fixing 50Mm X 5Mm Copper Strip In 60Mm Dia. G.I. Pipe. , Refer Soq Sh-Ii, Item No. 6. Providing And Fixing 50Mm X 5Mm Copper Strip On Surface Or In Recess For Connections Etc. - Refer Soq Sh-Ii, Item No. 6. Providing And Fixing 50Mm X 5Mm Copper Strip On Surface Or In Recess For Connections Etc. As Required. , Refer Soq Sh-Iii, Item No. 1.A. Supply Of 4C X 25 Sq.Mm Armoured Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 1.B. Supply Of 3.5C X 70 Sq.Mm Armoured Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 1.C. Supply Of 3.5C X 185 Sq.Mm Armoured Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 1.D. Supply Of 3.5C X 240 Sq.Mm Armoured Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 2.A. Supply Of 12C X 2.5 Sq.Mm Lt Control Cables , Refer Soq Sh-Iii, Item No. 3.A. Supply Of 40 Mm Dia. Hdpe Pipe , Refer Soq Sh-Iii, Item No. 3.B. Supply Of 63 Mm Dia. Hdpe Pipe , Refer Soq Sh-Iii, Item No. 3.C. Supply Of 90 Mm Dia. Hdpe Pipe , Refer Soq Sh-Iii, Item No. 4.A. Providing, Laying And Fixing Of 40 Mm Dia. Medium Class G.I. Pipe In Ground , Refer Soq Sh-Iii, Item No. 4.A. Providing, Laying And Fixing Of 80 Mm Dia. Medium Class G.I. Pipe In Ground , Refer Soq Sh-Iii, Item No. 5. Laying Of 40 Mm Dia. Hdpe Pipe , Refer Soq Sh-Iii, Item No. 6.A. Laying, Jointing And Commissioning Of 90Mm Dia. Hdpe Pipe By Carrying Out Hdd. - Refer Soq Sh-Iii, Item No. 6.A. Laying, Jointing And Commissioning Of 90 Mm Dia. Hdpe Pipe By Carrying Out Hdd Method , Refer Soq Sh-Iii, Item No. 7.A. Laying Of Power Cable Of 1.1 Kv Grade Of Size Upto 35 Sq.Mm In Pipe , Refer Soq Sh-Iii, Item No. 7.B. Laying Of Power Cable Of 1.1 Kv Grade Of Size Above 35 Sq.Mm And Upto 95 Sq.Mm In Pipe , Refer Soq Sh-Iii, Item No. 7.C. Laying Of Power Cable Of 1.1 Kv Grade Of Size Above 95 Sq.Mm And Upto 185 Sq.Mm In Pipe , Refer Soq Sh-Iii, Item No. 7.D. Laying Of Power Cable Of 1.1 Kv Grade Of Size Above 185 Sq.Mm And Upto 400 Sq.Mm In Pipe , Refer Soq Sh-Iii, Item No. 8.A. Laying And Fixing Of Power Cable Of 1.1Kv Grade Of Size Above 95Sq.Mm And Upto 185Sq.Mm On Existing Cable Tray - Refer Soq Sh-Iii, Item No. 8.A. Laying And Fixing Of Power Cable Of 1.1 Kv Grade Of Size Above 95 Sq.Mm And Upto 185 Sq.Mm On Existing Cable Tray , Refer Soq Sh-Iii, Item No. 9.A. Laying And Fixing Of Power Cable Of 1.1 Kv Grade Of Size Upto 35 Sq.Mm On Wall Or Surface. - Refer Soq Sh-Iii, Item No. 9.A. Laying And Fixing Of Power Cable Of 1.1 Kv Grade Of Size Upto 35 Sq.Mm On Wall Or Surface As Required , Refer Soq Sh-Iii, Item No. 9.B. Laying And Fixing Of Power Cable Of 1.1Kv Grade Of Size Above 35Sq.Mm And Upto 95Sq.Mm On Wall Or Surface - Refer Soq Sh-Iii, Item No. 9.B. Laying And Fixing Of Power Cable Of 1.1 Kv Grade Of Size Above 35 Sq.Mm And Upto 95 Sq.Mm On Wall Or Surface As Required , Refer Soq Sh-Iii, Item No. 10.A. Supplying And Making End Termination For 4C X 25 Sq.Mm Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 10.B. Supplying And Making End Termination For 3.5C X 70 Sq.Mm Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 10.C. Supply And Making End Termination For 3.5C X 185 Sq.Mm Aluminium Conductor Cable Of 1.1 Kv Grade - Refer Soq Sh-Iii, Item No. 10.C. Supplying And Making End Termination For 3.5C X 185 Sq.Mm Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 10.D. Supply And Making End Termination For 3.5C X 240 Sq.Mm Aluminium Conductor Cable Of 1.1 Kv Grade - Refer Soq Sh-Iii, Item No. 10.D. Supplying And Making End Termination For 3.5C X 240 Sq.Mm Aluminium Conductor Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 11.A. Supply And Making End Termination For 12C X 2.5 Sq.Mm Armoured Cable Of 1.1 Kv Grade - Refer Soq Sh-Iii, Item No. 11.A. Supplying And Making End Termination For 12C X 2.5 Sq.Mm Armoured Cable Of 1.1 Kv Grade , Refer Soq Sh-Iii, Item No. 12. Demolishing Cement Concrete Or Bituminous Road Or Paver Block Roads By Manual Or Mechanical Means Including Disposal Of Material Within 50 Mtr. - Refer Soq Sh-Iii, Item No. 12. Demolishing Cement Concrete Or Bituminous Road Or Paver Block Roads By Manual Or Mechanical Means Including Disposal Of Material Within 50 Meters , Refer Soq Sh-Iii, Item No. 13. Providing And Laying In Position Cement Concrete 1-2-4 In Foundation Or Road Crossing Etc.
|