Works For Complete Or Part Construction And Civil Engineering Work – Realization Of A 2X5000 M3 Potable Water Storage Complex. The Task Is To Construct A Complex Of 2X 5,000 M³ Open-Air, Twin Drinking Water Storage Basins Suitable For Storing Drinking Water At The High Point Of The Dn600 Göv Pipeline Between The Keleti Main Channel Surface Water Purification Plant (Kfcs) And The Debrecen I Water Plant In Accordance With The Customers Technical Requirements And Design Documentation. As A Result Of The Investment, A New Water Plant Will Be Established, Within The Framework Of Which The Storage Basins (Látóképi Water Storage) Will Be Filled With The Existing Network Pumps Of The Kfcs Water Plant, While The Drinking Water Will Reach The Debrecen I Water Plant By Gravity. The Following Will Be Planned As Part Of The Investment: 1. Construction Of An Artefact, Dividing Shaft, Lock Chamber: - Internal Dimensions: O Pool 2 Pcs Ø36.3 M X 6.0 M - Depending On The Technology, The Contracting Authority Allows A Change In The Internal Diameter Of A Maximum Of ±30 Cm (Construction Technology Tolerance), In The Event That The Contractor Guarantees That Each Chamber Of The Pool Has A Capacity Of 5000 M3, I.E. In Total 2X5000m3 Volume Suitable For Storing Drinking Water According To The Design Documentation. O Treatment Building 26.0 M X 22.0 M X 8.3 M O Dividing Shaft 5.0 M X 9.5 M X 3.7 M - Amount Of Concrete To Be Installed (Approx.) O 2 Pools And Treatment Building, Dividing Shaft 7275 M3, Of Which Pile Foundation: 2137.625 M3 - Size Of Pool Boundary Earthwork (Approx.): 12,600 M3 - Number Of Main Gate Valves To Be Installed: 8 Dn 600 Motorized Gate Valves, 5 Dn800 Motorized Gate Valves, 2 Dn300 Handwheel Gate Valves, 2 Dn600 Check Valves, 2 Dn800 Check Valves - Quantity And Size Of Main Pipelines To Be Built (Approx.): 107 Fm Dn600, 92 Fm Dn800, 36 Fm Dn300 - Size Of Chlorine Gas Dispenser: 2 Kg/H Capacity 2. External Buildings - Wire Requirement For Connecting External Utilities (Approx.) Main Yard Lines: 71 Fm Dn800, 110 Fm Dn600, 85 Fm Dn300 Pipeline - Size Of Service Roads (Approx.): 670 M2 - Size Of Boundary Fence (Approx.): 850 Fm - Size Of Green Area (Approx.): 6,630 M2 - Number Of Ground Cover Shrubs To Be Installed (Approx.): 10,000 Cs10 Container-Sized Plants 3. Parameters Of Automation And Control Technology - Security Equipment: 1 Recorder, 12 Cameras - Integration Of New Control Technology Into The Existing Control System, Remote Control And Monitoring Minimum Technical Requirements For The Structure: The Following Minimum Requirements Must Be Taken Into Account In The Subsequent Planning And Execution Together With Those Described In The Tender Plan. These Are Minimum Requirements, And It Is The Responsibility Of The Contractor And Responsible Designer To Ensure Compliance With Professional Regulations, Standards And Legislation: · Minimum Quality Of Structural Concrete C30/37 - Xv3(H) · Watertightness Class Of Structure: Class 1 Wmax≤0.2Mm · Definition Of Design Life: 50 Years · Consequence Class (Factor Ratio) And Kfi, Multiplier Definition: Cc2 Class, Kfi=1.0 · Buildings Importance Classes And Importance Factors: Iii. Importance Class G1=1.2 Minimum Amount Of Reinforced Concrete To Be Installed: 7275 M3 Ak Draws Attention To The Fact That The Construction Of A Drinking Water Storage Pool
Contact Information
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 118094083
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.