supply & installation of lab equipment , department of zoology , senior precision rotary microtome (spencer 820 type)(weswox optik™ mt-1090a), sturdy, rigid construction with an aluminium cover hinged to the base protecting the interior parts and opens to provide easy access for cleaning and lubrication; automatic feed release with automatic safety device: total feed excursion of 28mm; critical accuracy up to 1 micron in thickness; front -positioned feed indicator with latest cam drive system; technical data: feed adjustment 1-50 microns (in steps of 1 micron each), opening of object clamp (ball and flange type) 37x27 mm; size: 16x10x9 box containing standard accessories as 120 mm razor with back and handle in case; object holder diameter 22mm, 25mm, 28mm; 3 tightening key, dust cover, oil can and manual instruction. , hot air oven(any reputed and reliable brand), with digital temperature controller cum indicator; temperature range (to be set): 40°c 125°c; temperature accuracy: ±1°c or better; with timer; inner working size of oven: minimum 12x12x12; construction: double walled; inner chamber: s.s. 304 grade; insulation: high grade glass wool insulation between two walls; power supply: 220v , digital blood pressure machine(omron hem-7120), measurement method: oscillometric method; bp measurement range: 20-280 mmhg; pulse measurement range: 40-180 bpm; accuracy: pressure- ±3 mmhg, pulse- ±5%; power source: 4 aa batteries 1.5v and ac adapter ac 100-240v 50-60hz; arm cuff: circumference 22-32 cm. , original ac adapter for blood pressure monitors (240 v)(omron adapter s (240v)), , benchtop ph meter(hanna instruments hi2211), ph range: 0 to 14 ph resolution: 0.01 ph ph accuracy: ±0.01 ph ph calibration: automatic, one or two-point with five memorized buffer values (ph 4.01, 6.86, 7.01, 9.18, 10.01) ph temperature compensation: automatic or manual from -9.9 to 120.0°c ph input impedence: 10¹² ohms power supply: 12 vdc adapter (included) environment: 0 to 50°c (32 to 122°f; 273 to 323 k) , photocolorimeter(labtronics lt-116 digital), wavelength range: 400 - 700 nm accuracy +0.01 od detector: silicone photodiode filter range: 400 nm, 430 nm, 500 nm, 520 nm, 540 nm, 580 nm, 600 nm, 620 nm, 680 nm light source: highly accurate laser source , department of chemistry , magnetic stirrer hot plate (tarson 18x18 cm ceramic spinot magnetic stirrer hot plate 6030), tarson 18x18 cm ceramic spinot magnetic stirrer hot plate 6030 , hot air oven(any reputed and reliable brand), with digital temperature controller cum indicator; temperature range (to be set): 40°c 125°c; temperature accuracy: ±1°c or better; with timer; inner working size of oven: minimum 12x12x12; construction: double walled; inner chamber: s.s. 304 grade; insulation: high grade glass wool insulation between two walls; power supply: 220v , refrigerators(any reputed and reliable brand), double door above 250 liter , centrifuge(mediray / mht-15 / haematocrit centrifuge 13000 r.p.m), haematocrit centrifuge 13000 r.p.m.model mht-15, abs , uv cabinet for chromatography analysis(generic), uv cabinet for chromatography analysis tabletop - dual 254nm & 365nm wavelength tlc viewer chamber, enclosed uv light inspection box , potentiometer(equitronics), , conductivity meter(systonic), , ph meter(systonic), , computetr equiped with printer, box(dell, 8 gb ddr5 ram, 512 gb ssd hardisk), , department of botany , autoclave(scientrument brand / equivalent), 20–25 litre double-wall stainless-steel vertical autoclave; 2–3 kw; temperature up to 121°c; pressure 15–20 psi; double-wall insulation; fully/semi-automatic; floor-mounted; minimum 2-year warranty. , digital ph meter(goko / systronic / equivalent), digital lcd/table-top ph meter; ph range 0–14.00; mv measurement; combination ph electrode; buffer tablets/solutions; suitable for laboratory use. , bench-top centrifuge(remi r8c plus + head a-24-15 / equivalent), bench-top centrifuge; maximum speed about 6000 rpm; digital display; suitable rotor/head; timer and safety features; laboratory grade. , bod incubator (cooling)(scientrument brand / equivalent), inner material ss; chamber volume about 250 l; 2–4 shelves; temperature range 5–60°c; accuracy approximately ±0.1°c; minimum 2-year warranty. , laminar air flow bench / laminar hood(scientrument brand / equivalent), laminar flow bench; ms crca / ss 304 construction; laminated work table top / ss 304 option; washable hdpe pre-filter; hepa post-filter with 99.97% efficiency at 0.3 micron; minimum 2-year warranty. , digital balance(wenser mab-220t / equivalent), capacity 0–220 g; precision/readability 0.001 g; laboratory-grade digital balance; minimum 1-year warranty. , distillation plant(borosil / equivalent), laboratory distillation plant using borosilicate glass; 2-litre heating mantle with plug and cord; suitable for routine laboratory distillation. , induction cooktop(to be quoted by bidder / equivalent), laboratory-compatible induction cooktop; adjustable power and temperature settings; suitable cookware support; safety cut-off and overheat protection. , microwave oven(to be quoted by bidder / equivalent), laboratory/departmental microwave oven, approximately 20–30 litre capacity; multiple power levels, timer and standard safety features. , rotary shaker(to be quoted by bidder / equivalent), laboratory rotary shaker with adjustable speed, speed control, timer, and suitable platform/attachments for routine sample mixing. , department of physics , set-up for determination of moment of inertia of a metallic cylinder / rectangular rod about an axis passing through its center of gravity. (model- mim-05 make- digit-all), complete in all respect , set-up for determination of modulus of rigidity of a suspension wire by dynamical method (model- tpe-201 make-kamaljeeth instruments), complete with desktop type of size 250 x 250 x 900 mm with levelling screw, one mi plate (circular or rectangular or irregular) with chuck nuts, brass wire of dia 1mm, length 2m, mi plates – circular, rectangular & irregular , jollys apparatus for measurement of pressure coefficient of expansion of air. (model- pic-12 make- digit-all), complete with mercury, thermometer, beaker , set-up for measurement of planks constant by using led (model- pca-01 make- digit-all), the method is based on well known expression of diode current for vv0. the dependence of current with temperature is measured, keeping the v slightly below v0 and material constant ? is obtained from v-i characteristics of the diode. with digital voltmeter , ammeter, set of leds – 5 leds of known wavelength, 0-1a constant current power supply , set-up for measurement of e/m of electron using bar magnet (model- 1101 make-kamaljeeth instruments.), experiment setup consists: a) power supply - ht and lt power supply with digital meter, focus and intensity control, x shift for beam adjustment and variable deflection potential knob b) crt tube arrangement – on acrylic stand and slidable on a wing bridge stand c) wing bridge stand - graduation upto 15 cm on either sides d) compass – 4 inch diameter with mirror e) bar magnet – pair of 50 mm alnico magnets , set-up to study photo-electric effect (model- plk-01 make- digit-all), experiment setup consists: a) 15 inch small optical bench with fitted mm scale b) planck’s constant kit - variable regulated power supply, digital voltmeter and digital nano-ammeter c) gd-28 photo tube arrangement d) variable intensity spectrum tungsten filament illuminator e) set of patch cords f) filters set (set of 5 different filters) , set-up to verify malus law using polaroid experiment setup consists: (model- ml-105 make- digit-all), experiment setup consists: a) optical bench - ½ m length optical bench with 4 kinematic mounts – aluminium rail with heavy base and levelling screws b) digital light intensity meter - detects intensity of light incident on it and displayed as relative light intensity c) polarizer - graduated 360° scale with lc 5° d) analyzer - graduated 360° scale with lc 5° e) 5mw laser light with power supply , travelling microscope (model: tdm-201 make-kamaljeeth instruments), travelling microscope travelling microscope – micrometer type travelling microscope - 2 motion (x and z axes) base: cast iron moving parts: made of brass x- axis movement: 180 mm measurement: screw gauge type least count: 0.01 mm z- axis movement: 140 mm measurement: screw gauge type least count: 0.01 mm magnifier: yes , searles apparatus for determination of elestic constsnt of a material of a wire (model: sel-2004 make-kamaljeeth instruments), experiment setup consists: a) searle’s double bar on a stand – double bar arrangement suspended by hooks. sample rods are provided b) digital stop clock – mains operated, start/stop switch and reset button on front face. range 999.9 sec / resolution 0.1 sec. , set-up for verification of stefans law experiment setup consists:(model- sta-01 make- digit-all), experiment setup consists: a) 0-1a variable constant current power supply, digital voltmeter and digital ammeter b) 12 volt bulb & circuit fibracation. d) set of patch cords , set up for drawing the b-h hystresis curve of a given ferromagnetic specimen in the from of anchor ring using loop tracer (model- 501 make-kamaljeeth instruments dso model-smo502ed+ make- scientific), experiment setup consists: a) magnetic hysteresis kit - ac power supply, load resistor and filter circuit coupled with ferrite core coil of equal primary and secondary windings, connecting wires b) digital storage oscilloscope – 100 mhz dual channel, xy mode, , set-up for determination of dielectric constant of a material/ materials using fixed frequency ac source . (model- ale-239a make- digit-all), experiment setup consists: (a) r.f. generator (range: 9-10mhz approx.). (b) micro ammeter (range : 0-50 (c) potentiometer for sensitivity selection. (d) test capacitor for solid (metal aluminium sheets with variable air gap) (e) test capacitor for liquid (round metal aluminium sheets with fixed air gap) (f) variable gang capacitor. (g) sockets for test capacitor and variable capacitor brought out at front panel. (h) one solid bakelite plate to be insert in rap of test capacitor , set of tuning forks (make-kamaljeeth instruments), experiment setup consists: steel tunning fork set & rubber pad – set of 8 different frequency tunning forks of known frequencies , measurement of thickness of paper by interference pattern created by a wedge shaped film (model- wsf-06 make- digit-all), experiment setup consists: complete with sodium vapur lamp set, travelling microscope , power supply 5/1a volt variable with digital volt meter & short circuit protection(model- dps-501 make- digit-all), power supply 5/1a volt variable with digital volt meter & short circuit protection , power supply ±12 volt for op-amp with ±12v, ±0.44v, ±0.33v, ±0.22v, ±0.15v, ±0.1v, ±0.05v(model- opt-12 make- digit-all), power supply ±12 volt for op-amp with ±12v, ±0.44v, ±0.33v, ±0.22v, ±0.15v, ±0.1v, ±0.05v , multimeter (metravi) digital multimeter (model- dm-85t make- metravi), multimeter (metravi) digital multimeter with ac/dc voltage, ac/dc current, resistance, diode, capacitance, frequency, temperature (°c & °f), ncv, continuity, true rms, data hold, back light, torch light, auto range, auto power off. , digital voltmeter (model- dvm-02 make- digit-all), digital voltmeter range- 2v/20v , digital ammeter (model- dam-02 make- digit-all), digital ammeter range- 200ma/20ma , digital micro ammeter (model- damm-01 make- digit-all), digital micro ammeter range0-200µa , galvanometer (make- beemet), galvanometer table type 50-0-50 size- dcf-120mm , ic 74ls00, 74ls153, 74ls10, 74ls20(make- hitachi), ic 74ls00, 74ls153, 74ls10, 74ls20
|