|
Bids Are invited for Annual Maintenance Service-Air Conditioner - Uninstallation Of Split Ac (Indoor And Outdoor Unit), Including Safe Recovery Of Refrigerant, Capping Of Pipes And Making Good The Vacated Position , Uninstallation Of Window Ac, Including Removal Of Frame, Sealing Of The Opening And Making Good The Wall Surface , Installation Or Re-Installation Of Split Ac At A New Point — Mounting Of Indoor And Outdoor Units, Flaring, Leak-Testing, Evacuation, Vacuumization, Gas Top-Up, Testing And Commissioning, Complete In All Respects (Covers Both Re-Installation Of An Existing Covered Unit And Standard Installation Of An Additional Unit) , Installation Or Re-Installation Of Window Ac At A New Point — Frame Fixing, Sealing, Levelling, Testing And Commissioning, Complete In All Respects (Covers Both Re-Installation Of An Existing Covered Unit And Standard Installation Of An Additional Unit) , For 1.5 Ton Split Ac — 1/4? (6.35 Mm) Liquid Line + 1/2? (12.7 Mm) Suction Line, Insulated Pair With Vinyl Taping, Laid And Fixed Complete , For 2 Ton Split Ac — 3/8? (9.52 Mm) Liquid Line + 5/8? (15.88 Mm) Suction Line, Insulated Pair With Vinyl Taping, Laid And Fixed Complete , Power Supply Wire, Wall Socket To Unit — 3-Core, 2.5 Sq.Mm (For 1.5 Ton Split And Window Ac, Inverter And Non-Inverter Alike) , Power Supply Wire, Wall Socket To Unit — 3-Core, 4 Sq.Mm (For 2 Ton Split Ac, Inverter And Non-Inverter Alike) , Interconnecting Cable, Indoor Unit To Outdoor Unit — 4-Core, 2.5 Sq.Mm (For 1.5 Ton Split And Window Ac, Inverter And Non-Inverter Alike) , Interconnecting Cable, Indoor Unit To Outdoor Unit — 4-Core, 4 Sq.Mm (For 2 Ton Split Ac, Inverter And Non-Inverter Alike) , 3-Pin Top Plug, 16 A Heavy-Duty, Isi-Marked, Wired And Connected To Wall Socket , Outdoor-Unit Wall-Mounting Bracket — Long-Arm Or Short-Arm As Directed, Ms Powder-Coated Or Galvanised, With Fasteners, Fixed To Wall Complete. Applicable Only To A Relocation, A New Installation, Or A Unit Not Covered Under Part-A; Replacement Of A Bracket On A Covered Air-Conditioner Is Included In The Part-A Rate (Section Iv, Clause 9) , Outdoor-Unit Floor-Standing Stand, Ms Powder-Coated Or Galvanised, With Fasteners, Fixed Complete. Applicable Only To A Relocation, A New Installation, Or A Unit Not Covered Under Part-A; Replacement Of A Stand On A Covered Air-Conditioner Is Included In The Part-A Rate (Section Iv, Clause 9) , Pvc Rigid Drain Pipe, 25 Mm Nominal Bore, Laid And Fixed With Clips At Not More Than 600 Mm Centres, With Bends And Joints Complete , Black Nitrile / Elastomeric Pipe Insulation, 9 Mm Wall Thickness, With Adhesive And Jointing Tape, Fixed Complete. Applicable Only To Re-Insulation Of Retained Piping In A Relocation, Or To A Unit Not Covered Under Part-A; Insulation On A Covered Air-Conditioner Is Included In The Part-A Rate (Section Iv, Clause 9) , Pvc Casing-Capping Channel, 75 Mm × 40 Mm (Internal), Sized To Take The Refrigerant Pipe Pair, Drain Pipe And Interconnecting Cable Of A 1.5 Ton Ac — Laid And Fixed To Wall With Screws, Plugs And Clips, Including Bends And Junctions , Pvc Casing-Capping Channel, 100 Mm × 45 Mm (Internal), Sized To Take The Refrigerant Pipe Pair, Drain Pipe And Interconnecting Cable Of A 2 Ton Ac — Laid And Fixed To Wall With Screws, Plugs And Clips, Including Bends And Junctions , Pvc Flexible Corrugated Pipe, 19 Mm Or 25 Mm Internal Diameter As Required, For Covering Refrigerant Piping And Drainage, Laid And Fixed With Clips Complete , Universal Remote Handset, Programmed And Paired To The Unit. Applicable Only To An Air-Conditioner Not Covered Under Part-A — For Ex Le A Machine Relocated Into These Premises From Elsewhere; Replacement Of The Remote Of Any Of The 46 Covered Air-Conditioners Is Included In The Part-A Rate (Section Iv, Clause 9) , Universal Back Plate / Mounting Plate For Indoor Unit, Fixed To Wall Complete , Plyboard Backing For Indoor Unit, Supplied And Fixed To Wall To Receive The Indoor Unit , Fastener Set (Anchor Bolts, Screws, Plugs, Cl S) For Mounting Of Indoor And Outdoor Units , Wall Sleeve For Passage Of Refrigerant Piping Through The Wall, Fixed And Sealed Complete , Complete Evacuation, Vacuumisation And Recharge Of A 1.5 Ton Air-Conditioner Not Covered Under Part-A, To The Manufacturers Specified Charge, With Whichever Refrigerant The Oem Specifies For The Unit (R-22, R-32, R-410A Or Other), Including Leak Detection And Rectification, Brazing, Dehydration, Testing And Labour — Complete In All Respects , Complete Evacuation, Vacuumisation And Recharge Of A 2 Ton Air-Conditioner Not Covered Under Part-A, To The Manufacturers Specified Charge, With Whichever Refrigerant The Oem Specifies For The Unit (R-22, R-32, R-410A Or Other), Including Leak Detection And Rectification, Brazing, Dehydration, Testing And Labour — Complete In All Respects , Nitrogen Flushing And Pressure-Testing Of Existing Copper Piping Proposed To Be Re-Used, Including Certification Of Soundness , Pre-Installation / Pre-Relocation Site Survey And Technical Feasibility Report
|