|
Tender For Lbw And Revenue Works Under Age B&R-Ii Of Ge(S) Bathinda At Bathinda Mil Stn (Job No. Lbw-13 Of 26-27 And Rev- 14 Of 26-27)- 1 Excavating In Post Holes Or Similar Holes Each N.Exc 0.50 Cum Getting Out, Returning Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Arround In Layers N Exc 25Cm Watering And Ramming Surplus Soil To A Distance E Exc 50M And Making Good As In Soft/Loose Soil Complete All As Specified And Directed. 2 M & L For Pcc (1:2:4) Type B-2 (40Mm Graded Aggregate) As In Foundation Filling And Mass Concrete For Embedding Post Complete All As Specified And Directed. 3 M & L For Steel Work In Tubular Trusses Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To I. S.1161- 1979 Grade St.-240 Roof Trusses/ Framing For Roofing, Purlins, Grill/Guard Bars, Gates Etc, Complete All As Specified And Directed 4 S&F Mild Steel Plates (Plain Or Chequered) Channels,Squarecut Or Notched (Ordinary And Counter Sunk) Forming Holes, W/O Any Attachment Conforming To Fe-410-W( Gde-E-250 )Quality -A Complete All As Specified And As Directed. 5 M & L Mild Steel Screw Bolts (Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other Or Screwed Both Ends ,Each Screwed End To Be Fiitted With Washer And One Hexagonal Or Square Nut Length Of Bolt Exc 5 Cm But N Exc 10Cm Long Complete All As Specified Amd Directed . 6 S & F Pre- Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of An Green Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And Directed. 7 M & L For Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Chrome Primer On Steel Surface Over 10Cm Grith Including Preparation Of Surace Complete All As Specified And Directed. 8 Excavating In Trenches, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out Complete All As Specified And Directed. 9 Returning, Filling In Including Spreading, Leveling Watering And Well Ramming In Layers N. Exc 25 Cm In Soft/Loose Soil & Hard Dense Soil Complete All As Specified And As Directed. 10 Removal Of Excavated Material To A Distance Not. Exceeding 50M & Depositing Where Directed At Level Not Exceeding 1.5M Above The Starting Point Complete All As Specified And As Directed . 11 M&L Brick Work With Sub Class `B Bricks Straight Or Curved On Plan Exc 6.0M Mean Radius Built In Cement Mortar 1:6 Etc Complete All As Specified And As Directed. 12 M&L For Rendering 15Mm Thick In Cement Mortar 1:6 On Internal Wall Surfaces Of Brick Work Or Concrete Surfaces And Finishing The Surface Even & Smooth Without Using Extra Cement Complete All As Specified. 13 Material & Labour For Applying Two Or More Coats Of 100% Premium Acrylic Emulsion Paint Having Voc Less Than 50 Gm/Litre And Uv Resistance As Per Is 15489:2004, Alkali & Fungal Resistance, Dirt Resistance Exterior Paint Of Required Shade (Company Depot Tinted) With Silicon Additives @ 1.43 Litre/ 10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 0.90 Litre/ 10 Sqm Over New Surfaces Complete All As Specified And Directed 14 M & L 75Mm Thick, Cement Concrete 1:3:6, Type C2 (40Mm Graded Aggregate) As In Floors, Plinth Protection, Paths, Etc And Finishing Top Surfaces Even And Smooth (Without Using Extra Cement) Etc Complete All As Specified And As Directed. 15 M&L Hard Core Of Broken Stone Gauge Not Exceeding 63Mm Deposited, Spread And Levelled In Layers Not Exceeding 15Cm Thick, Watered And Rammed To A True Surfaces With Broken Bricks Bats Complete All As Specified And Directed. 16 M&L Pcc (1:4:8) Type D-2 Using 40Mm Graded Stone Aggregate In Foot Path/Walk Way Surface Finished Even & Fair Without Using Extra Cement Complete All As Specified And Directed. 17 M&L For Pre-Polished Kota Stone 20-25Mm Thick As In Flooring, Cills And Strair Case Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rounding Of Edges Complete All As Specified And Directed. 18 M&L Pcc (1:2:4) Type B-2 Using 40Mm Graded Stone Aggregate In Foot Path/Walk Way Surface Finished / Side Locking Of Path Etc. Even & Fair Without Using Extra Cement Complete All As Specified And Directed. 19 M & L For Providing And Laying 60Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block/ Interlocking Tile Of M-35 Grade, Prepolished & Preglazed, With Approved Colour, Design & Pattern (Laid In Required Colour & Pattern As Directed) As In Footparth, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc., Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand Complete All As Specified And As Directed 20 Providing, Cement Concrete B0 (12.5Mm Graded Stone Aggregate) In Lintels Upto 1.5M Clear Span, Cills, Steps, Seismic And Other Similar Bands, Plinth Courses, String Courses, Lacing Courses, Parapets And Railings Upto 60Cm In Height, Copings, Kneelers, Apex Stones, Bed Plates, Kerbs, Water Troughs And The Like Including Weathering, Slightly Rounded Or Charmfered Angles And Throating, Complete All As Specified And Directed. 21 M & L For Extra For Forming Fair Finished Drain Or Channel 30Cm Inner Grith In Cement Concrete, Using Extra Cement Including Forms, Moulds, Mit-Tred /Stopped Ends Etc. Complete All As Specified And Directed. 22 M & L For Moorum/Red Bajri Filling In Floors Or Paving, Laid In Layers N. Exc 15Cm Thick, Speed, Levelled And Rammed Including Watering Complete All As Specified And Directed. 23 Surface Excavation N.Exc 30Cm Depth & Average 15 Cm Deep & Getting Cut In Soft/Loose Soil Complete All As Specified And As Direcetd. 24 Material And Labour For Concealed One Light / Fan Point Controlled By One, One Way Modular Switch 06 Amp Wiring With 1.5 Sq Mm Nominal Cross Sectional Area, Single Core, 1100 Volt Grade, Multi-Stranded, Pvc Insulated, Unsheathed Frls Copper Conductor Cable With And Including Continuous Earth Wire Of Size 1.5 Sq Mm Nominal Cross Sectional Area, Single Core, 1100 Volts Grade, Multi-Stranded, Pvc Insulated, Unsheathed, Frlsh Copper Conductor Cable And Connected To Common Earth And Earth Dolly With Suitable Copper Lugs And Drawing Into And Including Rigid Non-Metallic Pvc Conduit Of 20 Mm Dia In Medium Grade Complete With And Including All Pvc Conduit Accessories Concealed Into Wall By Cutting Of Chases In Wall Complete And Including Modular Metal Flush Boxes Not Less Than 1.6Mm Thick Alongwith Modular Cover Plate With Frame Of Any Size For Mounting Of Any Type Modular Switches/Sockets/Bell Switch /Fan Regulator And Brass Screws, Cup Washers Etc Complete, Making Good The Distributed Surfaces Completely Matched And Finished With Existing Surface Including Painting Of Walls Etc Complete All As Specified And Directed. 25 All As Per Srl Item No. 24.00 (Here-In-Before) But One 3 Pin Socket Outlet 6 Amp On Same Board Point Complete All As Specified And Directed 26 All As Per Srl Item No. 24.00 (Here-In-Before) But One 3 Pin Socket Outlet 6 Amp On The Independent Board Point Complete All As Specified And Directed 27 All As Per Srl Item No. 24.00 (Here-In-Before) But For 15/16 Power Point (Ac & Geysers) By Using 4.0 Sqmm Pvc Insulated Unsheathed Copper Conductor Cable Fr-Lsh Multi Strand On Independent Board Including Provn Of 4.0 Sqmm Unsheathed, Multi Stranded Copper Conductor Cable Fr-Lsh Continues As Earth Wire Connected To Earth Dolly Etc Complete All As Specified And Directed 28 S & F Modular Switch 1 Way 6A/10A 1 Module Single Pole Complete All As Specified And Directed. 29 S & F Modular Switch 1 Way 16A, 1 Module Single Pole Complete All As Specified And Directed. 30 S & F Modular Socket Oultet 6A - 2/3 Pin Combined 2 Module, 230 Volt, Multipurpose, Complete All As Specified And Directed. 31 S & F Modular Socket Oultet 6A - 2/3 Pin Combined 2 Module, 230 Volt, Multipurpose, Complete All As Specified. 32 S & F Modular Fan Step Regulator, 120W - 2 Module With 5 Steps Type Complete All As Specified. 33 S & F Ceiling Rose Surface Bake Lite With 3 Terminals Complete All As Specified And Directed. 34 Supply And Fixing Of Inverter Led Tube Light Fittings 1200 Mm, 20 W ,6500K Higher Energy Saving Decorative Ultra Slim Square Profile Led Lighting Fixture With Extruded Aluminium Housing ,Enviromental Friendly, Energy Efficient Ready To Use Pack And Comprising Of Batten With All Accessories Internally Prewired And Connecting Up With Twin Core Twisted Copper Conductor Cable Complete All As Specified And Directed. 35 Supply And Fixing Of Building Security Light Led Type Of Capacity 25 W Comprising With Pressure Die Cast Aluminium Housing Ip 66 Protection With All Accessories Internally Prewired And Including Connecting Up With Twin Core Twisted Copper Conductor Cable Of Suitable Size Including Bracket Made Of 40Mm Dia Gi Light Grade Pipe Of 1.2M Long Bent To Shape Fixed With Suitable Ms Clamps, Bolts, Nuts And Washers Duly Painted Complete All As Specified And As Directed Please Enable Macros To View Boq Information
|