Tender For Certain Revenue Works Under Ge Chandimandir- 1 Taking Down Copper/Aluminium Point Wiring (Light, Fan, Socket Or Power) Complete, Including Fixture And Fittings Such As Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting Etc. Removing Materials To Store For Keeping In Safe Custody Or For Taking Credit (Credit For Above Items Should Be Made As Per Conditions Separately) And Making Good Disturbed Surfaces Of Walls, Floors, Etc. Complete All As Specified And Directed. 2 Point Wiring With Approved Colour Code Multi Stranded Copper Conductor, Pvc Insulated And Unsheathed Frlsh Cable Of Size 1.5 Sqmm ,1100 Volts Grade, Two Run Of Single Core Cable For Phase & Neutral And One Run Of Single Core Multi Stranded Copper Conductor, Pvc Insulated And Unsheathed Frlsh Cable Of Size 1.5 Sqmm ,1100 Volts Grade For Earth Continuity Conductor To Common Earth And Connected To Earth Dolly In And Including New Concealed Rigid Non Metallic Pvc Conduit Of Suitable Size But Not Less Than 20 Mm Dia And Including New Modular Sunken Box And Suitable Size Of Frame, Cover Plate For Mounting Switch, Socket And Regulator Fixed On Surface Flush With Wall , Comprising Of One Light /Bell/Buzzer Point Controlled By One Switch Or One Fan Point Controlled By One Switch &Fan Regulator, Complete All As Specified And Directed. Note : Unit Rate Is Inclusive Of Making Good The Disturbed Surfaces By Provding By Wall Putty/Pop After Mason Work And Finshing To Match The Original And Nothing Extra Shall Be Paid On This Account. Note :Unit Rate Is Inclusive Of Cutting Chases In Wall /Foor/Pcc And Making Good The Disturbed Surfaces To Match The Original And Nothing Extra Shall Be Paid On This Account. 3 All As Per Serial Item 02 Herein Before But For Socket Outlet 3 Pin 5 Amps On Same Board Complete All As Specified And Directed 4 All As Per Serial Item 02 Herein Before But For Socket Outlet 3 Pin 6 Amps On Independent Board Complete All As Specified And Directed 5 All As Per Serial Item 02 Herein Before But One Socket Outlet Three Pin ,6/16 Amp, Independent Board, With 2.5 Sqmm (Nominal Area ) Frlsh Cable & 2.5 Sqmm (Nominal Area ) Cable As Earth Continuity Conductor, Complete All As Specified And Directed 6 Modular Switch (Isi Marked), Single Pole, One Way 6 Amps, One Module (Isi Marked), Complete All As Specified & Directed. 7 Switch Modular Type (Isi Marked), Single Pole, One Way, 16 Amps, One Module (Isi Marked), Complete All As Specified & Directed. 8 Socket Shutters Outlet 2/3 Pin 6 Amp Modular Type Multi Purpose Two Module (Isi Marked), Complete All As Specified & Directed. 9 Socket Shutters Outlet 2 In 1 Pin 6/16 Amp Modular Type Multi Purpose Combined 2 Module (Isi Marked), Complete All As Specified & Directed. 10 Modular Switch Type Stepped Fan Regulator, Single Pole, 230 Volt Two Module Complete All As Specified And Directed. 11 Ceiling Rose, Pvc Or Polycarbonate Of Size 65Mmx50Mm Three Terminals (Isi Marked) All As Specified And Directed By Engineer-In-Charge. 12 Led Sleek Modern Wall Light Fitting 24 Watt, 220 V Ac, Scene Switch Type Cool/Warm White Of Approx Size 868 X 93 X 33 Mm, Polycarbonate Body, Decorative/Modern Incl Fitting Fixed On Wall/Ceiling And Connecting Up Complete With Flexible Cable White Of Suitable Size And Making Necessary Connection, Complete All As Specified And Directed. 13 Inverter Type Led Tube Light Batten 4 Ft. 1 X 18/20 Watt, 230 Volts, Inverter Type Inbuilt Lithium Ion Battery With Charging Time 8 To 10 Hrs And Back Up Time Minimum 4 Hrs Complete Including Fitting Fixed On Wall/Ceiling And Connection Up Complete With Flexible Cable White Of Suitable Size And Making Necessary Connection, Fixed As In Repair Complete All As Specified And Directed. 14 Led Lights Fitting, 2 Feet, 1X 10W, Inverter Rechargeable, 220V, Ac Decorative Box Type With Driver, Holder Including Led Tube Light Connecting Up With Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Fixed As In Repair Complete All As Specified And Directed. 15 Recess / Surface Mounted Led, Ultra Slim, 2 X 2, 36 Watt, Cool Day/Warm White Light (6000 K), Edge Lit Tile In Extruded Aluminium / Crca Steel Sheet Powder Coated Housing With Full Opal Diffuser Suitable For Perfect Lighting Complete Including Cutting Hole Of Required Size In Pop/ False Ceiling And Making Good Of Disturbed Surface Complete All As Specified And As Directed By Engineer-In-Charge. 16 Recess/ Surface Mounted 1 X 4 Backlit Panel 36 Watt Full Glow Having With Powder Coate Crca Body With High Qulaity Pmma Diffuser, Fixed As In Repair Complete All As Specified And Directed. 17 Led Industrial Outdoor Type Bulkhead Luminaires,Ip Rating Not Less Than 45, Highly Resistant To Dust And Water 1 X 9/10 Watt Fitting In Engineering Plastic Housing With Clear Prismatic Diffuser Complete With All Accessories And Connecting Up With Flexible Cable White Of Suitable Size And Making Necessary Connection Fixed As In Repair Complete All As Specified And Directed. 18 Led Building Security Light Fitting 1 X 35 Watt New Generation Energy Saving And Environmental Friendly Long Life Led Street Light Made Up Of Pressure Diecast Aluminium Housing With High Power Led As Lighting Source And Lens Embedded Pc Cover Having Top Opening Seperate Driver Compartment With Ip65 Protection Incl Mounting Bracket Of Suitable Size And Connection Complete All As Specified And Directed. 19 Exhaust Fans With Louvers 450 Mm Sweep, 1400 Rpm, Heavy Duty Single Phase 240 Volts, Ac 50 Hz, Steel Body And Connecting Up Including Louvers Including Making Necessary Opening On Stone /Brick Masonry Wall Of Suitable Size, Finishing It Properly And Making Good With Matching Colour With The Surroundings Provision Of Cable 3 Core Of Suitable Size From Ceiling Rose To Fan Complete All As Specified And As Directed. 20 Wall Mounted Fans Dacorative Type 400 Mm Sweep Black Colour, 230V Ac Supply, 50 Hz, High Performance, Smooth Oscillation, Copper Wound Motor Made Of Sturdy Engineering Plastic And Metal Ribs Guard Complete As Per Complete All As Specified And As Directed. 21 Single Pole And Neutral Sheet Metal Enclosure With A Two Pin And Earth Plug And Socket Complete With One Number Single Pole Mcb 20 Amps , 240 Volts For Ac/Geyser Point Complete All As Specified And As Directed. 22 Taking Down Carefully Old Copper Or Aluminium Sub Main Wiring Of Any Nos Of Wiring And Size With Earth Wire On Wooden Batten/ Surface Conduit/ Casing- Capping Complete With Its All Accessories And Making Good Disturbed Surfaces Of Wall , Floors Etc Complete All As Specified And Directed. 23 Sub Main Wiring With Two Runs Of Single Core Pvc Insulated And Unsheathed Multistranded, Copper Conductor (Frlsh) Cable Of Size 4.0 Sqmm, Lt, 1100V Grade, Drawn Through And Including Adequate Size Pvc Non Metallic Conduit With Accessories And Fittings And One Run Of 4.0 Sq Mm Single Core Multi Stranded Copper Conductor Cable As Earth Continuity Conductor Complete All As Specified And Directed By Engineer-In-Charge. 24 Sub Main Wiring With Two Single Core Frlsh Pvc Insulated And Unsheathed Cable With Copper Conductor Of Size 10 Sqmm (Nominal Area), 1100 Volt Grade(With Approved Colour Coding As Per Is) With And Including Continuous Earth Wire Of Size 10 Sqmm Pvc Insulated And Unsheathed Frlsh Multi Stranded Copper Conductor 1100 Volts Grade , And Connected To Main Board Drawing Through Pvc Concealed Conduit 25Mm Size(Minimum Size), Cutting Chases In Walls For Pvc Concealed Conduit And Making Good The Disturbed Surfaces By Providing By Wall Putty/Pop After Mason Work And Finshing To Match The Original Surfaces And Nothing Extra Shall Be Paid On This Account All As Specified And Directed. Note For Serial Item No 23 & 24: (I) Two Runs Of Cable, One Run Of Earth Wire Shall Be Considered As One Running Metre(Ii) Cutting And Chases Shall Be Measured And Paid Separately.(Iii) Colour Code Shall Be Red For Phase, Black For Neutral And Green For Earth 25 Sub Main Wiring With Four Single Core Frlsh Pvc Insulated And Unsheathed Cable With Copper Conductor Of Size 10 Sqmm (Nominal Area), 1100 Volt Grade(With Approved Colour Coding As Per Is) With And Including Continuous Earth Wire Of Size 10 Sqmm Pvc Insulated And Unsheathed Frlsh Multi Stranded Copper Conductor 1100 Volts Grade , And Connected To Main Board Drawing Through Pvc Concealed Conduit 25Mm Size(Minimum Size), Cutting Chases In Walls For Pvc Concealed Conduit And Making Good The Disturbed Surfaces By Providing By Wall Putty/Pop After Mason Work And Finshing To Match The Original Surfaces And Nothing Extra Shall Be Paid On This Account All As Specified And Directed. 26 Sub Main Wiring With Four Single Core Frlsh Pvc Insulated And Unsheathed Cable With Copper Conductor Of Size 16 Sqmm (Nominal Area), 1100 Volt Grade(With Approved Colour Coding As Per Is) With And Including Continuous Earth Wire Of Size 16 Sqmm Pvc Insulated And Unsheathed Frlsh Multi Stranded Copper Conductor 1100 Volts Grade , And Connected To Main Board Drawing Through Pvc Concealed Conduit Of Suitable Size, Cutting Chases In Walls For Pvc Concealed Conduit And Making Good The Disturbed Surfaces By Providing By Wall Putty/Pop After Mason Work And Finshing To Match The Original Surfaces And Nothing Extra Shall Be Paid On This Account All As Specified And Directed. Note For Serial Item No 25 & 26: (I) Four Runs Of Cable, One Run Of Earth Wire Shall Be Considered As One Running Metre(Ii) Cutting And Chases Shall Be Measured And Paid Separately.(Iii) Colour Code Shall Be Red For Phase, Black For Neutral And Green For Earth 27 Cutting Chases, Pinning In. Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc., And Making Good, Cutting Not Exc 10 Cm Girth Complete All As Specified. 28 Disconnecting And Taking Down Old Unserviceable Dbs/Junction Box/Panels Ect Of Any Type And Size Complete Along With All Mccbs/Mcbs Etc All As Specified And Directed. 29 Vertical Tpn Distribution Board Double Door Flush Mounting With Provisions For Mccbs Incomer Upto 125 Amp & Outgoing 4 Way Having Ip 54 Protection Complete. 30 Mccb, 125 Amps, Four Pole, 3 Phase , 16Ka, 415 Volt With Adjustable Thermal And Magnetic Release, With Proper Thimble Complete All As Specified And Directed 31 Mcb Distribution Board Factory Made Sheet Metal Enclosure Double Door Distribution Board Class Ip-43 Ik 09 With 200 Amp Rated Copper Bus Bar 240 Volts 12 Way (2 + 10 Way) Single Pole And Neutral Link, Complete All As Specified And As Directed. 32 Mcb Distribution Board Factory Made Sheet Metal Enclosure Double Door Distribution Board With 200 Amp Rated Copper Bus Bar 240 Volts 04 Way Single Pole And Neutral Link, Complete All As Specified And As Directed. 33 Mcb Single Pole (Sp) 40 To 63 Amp 240 Volts 10 Ka C Series With All Incoming/Outgoing Connection With Proper Size Lugs, Complete All As Specified And Directed. 34 Mcb Single Pole (Sp) 6 To 32 Amp 240 Volts 10 Ka C Series With All Incoming/Outgoing Connection With Proper Size Lugs, Complete All As Specified And Directed. 35 Mcb, Dp , 240 Volt, 32Amps, 10 Ka , C Series Including Connection With Suitable Size Aluminium / Copper Lugs Complete All As Specified And Directed 36 Fabrication, Install, Testing And Commission Of Wall Mounted Sheet Metal Busbar Chamber Cpri Approved, Grouted With Nut And Bolts (With Proper Locking Arrangement And Holes To Distribute Circuits) Of Size 600X500X300Mm With Copper Strip 40Mm X 6Mm(04 Nos) Of Length 450Mm With Approved Colour Coded And Pvc Adhesive Coated, Ip-54 As Per Is-13947 Protection Fixed On Insulator With The Help Of Nut/Bolts Including Provison Of 10 Nos 08 Mm Dia Hole With 8 Mm Dia 50 Mm Long Nut/Bolts With 02 Nos Of Washer Connected With 16 Sqmm Single Core Colour Coding Stranded Copper Cable With Thimble/Lugs Including One Mccb, 125 Amps, Four Pole 3 Phase 25 Ka, 415 Volt With Adjustable Thermal And Megnetic Release Complete Having Adjustable Type Base Frame And Equal Space Around Mccb As Incommer One No, Making Good Distrubed Surfaces To Match With Original, Including Taking Down Existing Complete All As Specifed And Directednote:- Contractor Will Submit Drawing Of This Panel To Engr In Charge For Approval. 37 Earthing Complete With Galvanized Steel Earth Plate Electrode 600Mm X 600Mm X 6Mm Buried Directly In Ground Vertically To A Depth Not Less Than 2.25 Meter Below Normal Ground Level (With Top Edge Of Earth Plate Not Less Than 1.5 Meter Below Ground Level) Connected To Galvanized Iron Earth Lead Wire 4Mm Dia, (Main Earthing Lead ) By Means Of Galvanized Bolts, Nuts And Washers All As Shown In Electrical Plate No 5 Of Mes Schedule Part-I (1991) With Connected To Earth Test Point & To Main Switch Board With & Including Adequate Quantity Of Charcoal Dust And Common Salt Alround Earth Plate & 15 Mm Dia Gi Pipe Light Grade For Earth Lead Protection Pipe For Suitable Length And Gi Pipe 20 Mm Dia Light Grade For Watering Pipe With Funnel & Wire Mesh Including Necessary Earth Work And Pcc (1: 3 : 6) Type C-1 For Earth Pit And 40 Mm Thick Pre-Cast Rcc Cover In 1 : 2 : 4 Type B1 With 3 Nos 8 Mm Dia Tmt Bars Both Ways, Including Taking Down Existing Earthing Complete All As Specified & Directed. 38 Earthing Complete With Galvanized Steel Earth Plate Electrode 600Mm X 600Mm X 6Mm Buried Directly In Ground Vertically To A Depth Not Less Than 2.25 Meter Below Normal Ground Level (With Top Edge Of Earth Plate Not Less Than 1.5 Meter Below Ground Level) Connected To Galvanized Iron Earth Lead Wire 4Mm Dia, (Main Earthing Lead ) By Means Of Galvanized Bolts, Nuts And Washers All As Shown In Electrical Plate No 5 Of Mes Schedule Part-I (1991) With Connected To Earth Test Point & To Main Switch Board With & Including Adequate Quantity Of Charcoal Dust And Common Salt Alround Earth Plate & 15 Mm Dia Gi Pipe Light Grade For Earth Lead Protection Pipe For Suitable Length And Gi Pipe 20 Mm Dia Light Grade For Watering Pipe With Funnel & Wire Mesh Including Necessary Earth Work And Pcc (1: 3 : 6) Type C-1 For Earth Pit And 40 Mm Thick Pre-Cast Rcc Cover In 1 : 2 : 4 Type B1 With 3 Nos 8 Mm Dia Tmt Bars Both Ways, Complete All As Specified & Directed. 39 Excavation In Trenches Not Exceeding 1.5M Wide And Not Exceeding 1.5M In Depth For Foundation Etc Or For Shaft, Wells, Cesspits, Manholes, Pier Holes Etc Not Exceeding 10 Sqm On Plan And Getting Out In Soft And Loose Soil All As Specified & Directed By Engineer-In-Charge. 40 Returning Filling In, Including Spreading, Leveling, Watering And Well Ramming In Layers Not Exceeding 25 Cm Depth , Complete All As Specified And Directed. 41 Removal Of Excavated Material To A Distance Not Exceeding 50 Metre And Depositing Where Directed At A Level Not Exceeding 1.5 Metre Above The Starting Point , Complete All As Specified And Directed. 42 32Mm Outer Dia, Double Walled Corrugated (Dwc) Hdpe Duct Pipe Of Pressure Rating 6 Kgf/Sq. Cm Conforming To Is 14930 Part-Ii With Anti Rodent And Non Flame Propogating Properties Of Approved Colour With Fittings For Cable Protection Of Approval Make Complete , All As Specified And Directed 43 Post Top Lantern Led Type 20 Watt 230 Watt Volts Ac Outdoor Type With Decorative Post Top For 360 Degree Indirect Light Ip 65 Protection With Impact And Corrosion Resistant Compelte With Driver And Lamp Complete , All As Specified And Directed 44 Supply And Laying Xlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminium Conductor, 1100 Volts Grade, Cross-Sectional Area 10 Sqmm, 2 Core, Laid In Trenches , Sleeving Through Pipes Of Fixed On Poles & Wall Or Laid Under Floors Inlcuding Jointing With Suitable Size Of Alumunium Lugs As Specified And Directed. 45 Led 10 W Bollard Warm White Light Ip65 Having A Cylindrical Body For Architectural Outdoor Lighting , Typically Giving Off Light From The Sides, Suitable To Illuminate Walkways , Steps Of Pathways, Including All Necessary Excavation And Earth Work, Pcc (1:3:6) Type C-2 Using 40Mm Graded Stone Aggregate, Embedded Block And Disposal Of Surplus Soil To A Distance N.Exc 50 Metre Complete All As Specified And Directed. Make : Jaquar Cat Part No. Obl-Gry-Lblddsc010Xw Or Equivalent As Approved By Ge.
|