Tender For Maintenance/ Servicing And Attending Day To Day Complaints Of Hot Water Boilers (Hamam), Standalone Chs And Heating Appliances Installed At Sector C Under Age E/M-I Of Ge 865 Ews- 1 Comprehensive Maintenance Of Hot Water Plants/Standalone Chs Plants For Checking The Burner Assy, Fuel Pumps, Injectors, Starter, Cleaning The Outer Side Of Coil Etc And Checking Continous Electric Supply Including Checking And Rectification Of Electrical Fault Of Hot Water Boilers/Standalone Chs Plants Installed At Various Units Locations At Leh Area Under Age E/M-I, Making The Plants Functional Including Repair/ Replacement Of Unserviceable Parts As Per Site Requirement Complete All As Specified And/Or As Directed By Engr-In-Charge. Note : - The Replacement Of Unserviceable Parts Shall Be Measured And Paid Separately Under Respective Items. 2 Supply Only Photocell Suitable For 0.35/ 0.5/1.0/1.5 Lakh Kcal/Hr Burner. 3 Supply Only Ignition Transformer Electronical Type Suitable For 0.35/0.5/1.0/1.5 Lakh Kcal/Hr Burner Rod Assy. 4 Supply Only Sequence Controller Suitable For 0.35/ 0.5/1.0/1.5 Lakh Kcal/Hr Burner Rod Assembly. 5 Supply Only Thermostat Assembly Tail Type As Per Existing Suitable For 50-300 Degree Centigrade Temperature. 6 Supply Only Temp Controller Digital Type Dtc 503 With Sensor Suitable For 0.35/ 0.5/1.0/1.5 Lakh Kcal/Hr Lal 2.25 Burner Rod Assembly. 7 Supply Only Burner Nozzle Suitable For 0.35/0.5/1.0/1.5 Lakh Kcal/Hr. 8 Supply Only Electrode Suitable For Burner Of Capacity 0.35/ 0.5/1.0/1.5 Lakh Kcal/Hr. 9 Supply Only Oil Pressure Pump Suitable For Burner Of Capacity 0.35/ 0.5/1.0/1.5 Lakh Kcal/Hr As47A. 10 Supply Only Diesel/Fuel Filter As Per Existing. 11 Supply Only Push Botton Type On/Off Switches As Per Existing. 12 Supply Only High Pressure Fuel Pipe 1.5 Mtr As Per Existing. 13 Supply Only Rotary Type Switch As Per Existing Model And Type. 14 Supply Only Indicating Lamps R/Y/B As Per Existing. 15 Supply And Fix Burner Assembly In The Existing Hot Water Boiler Including Making Necessary Arrangments With All Required Fixing Materials And Made Functional The Hot Water Boiler Of Capacity 1.0 Lakh Kcal/Hr Complete All As Specified And/Or As Directed By Engr-In-Charge. 16 Supply And Fix Burner Assembly In The Existing Hot Water Boiler Including Making Necessary Arrangments With All Required Fixing Materials And Made Functional The Hot Water Boiler Of Capacity 0.5/0.35 Lakh Kcal/Hr Complete All As Specified And/Or As Directed By Engr-In-Charge. 17 Attending Complaints Of Heat Panel For Checking The Heating Element, Thermostat, Electrical Connection Etc., Checking Continous Electric Supply Including Checking And Rectification Of Electrical Fault For Heat Panels Installed At Various Unit Locations At Leh Area Under Age E/M -I, Making The Plants Functional Incl Minor Repairs Whereever Required As Per Site Requirement Complete All As Specified And/Or As Directed By Engr-In-Charge. 18 Supply And Fix In Replacement Thermostat Switch With 0-110 Degree Setting Complete All As Specified And/Or As Directed By Engr-In-Charge. 19 Supply And Fix In Replacement Of Digital Type Volt Meter Complete With Touch Control Switch 0-500 Volts Complete All As Specified And/Or As Directed By Engr-In-Charge. 20 Supply And Fix In Replacement Of Digital Type Amp Meter Complete With Touch Control Switch And Suitable Cts 0-300 Amps Complete All As Specified And/Or As Directed By Engr-In-Charge. 21 Supply And Fix In Replacement 50Mm Dia Gun-Metal Globe Or Gate Valve, With Iron Wheel Head, Screwed Both Ends For Iron/Gi Pipe And Fixed Complete All As Specified And/Or As Directed By Engr-In-Charge. 22 Supply And Fix In Replacement 40Mm Dia Gun-Metal Globe Or Gate Valve, With Iron Wheel Head, Screwed Both Ends For Iron/Gi Pipe And Fixed Complete All As Specified And/Or As Directed By Engr-In-Charge. 23 Supply And Fix In Replacement 25 Mm Dia Gun-Metal Globe Or Gate Valve, With Iron Wheel Head, Screwed Both Ends For Iron/Gi Pipe And Fixed Complete All As Specified And/Or As Directed By Engr-In-Charge. 24 Supply And Fix In Replacement Of Mk-I Starter As Per Existing Complete All As Specified And/Or As Directed By Engr-In-Charge. 25 Supply And Fix In Replacement Of Pvc Flexible Copper Multistrand Wire 3 Core Of 6 Sqmm As Per Existing, From Panel To Starter Complete All As Specified And/Or As Directed By Engr-In-Charge. 26 Supply And Fix In Replacement Of Pvc Flexible Copper Multistrand Wire 2 Core Of 6 Sqmm As Per Existing, From Panel To Starter Complete All As Specified And/Or As Directed By Engr-In-Charge. 27 Material And Labour For Rewinding Of Electric Motor 3 Phase 415 Volts Of Capacity 3/5 Hp With Superior Quality Super Enameled Copper Winding Wire Of Appropriate Size And Gauge As Existing Including Varnishing, Cotton Tape, Pvc Sleeves Etc. Including Dismantling And Re-Fixing Complete All As Specified And/Or As Directed By Engr-In-Charge. 28 Repair And Refixing Of Electric Motor 3 Phase 415 Volts Of Capacity 0.5/2.0 Hp With Superior Quality Super Enameled Copper Winding Wire Suitable For 0.35/ 0.5/1.0/1.5 Lakh Kcal/Hr Including All Parts, Derusting, Cleaning, Over Hauling, Etc. For Complete Replacement Of Spare Parts Such As Shaft, Winding, Bearing, Starter Rotor And All Connected Items And After Replacement, Reassembling Of Motor And Testing Complete All As Specified And/Or As Directed By Engr-In-Charge. 29 Taking Down Unserviceable Burner Set Of Capacity 1.0 Lakh Kcal/Hr From Boiler And Removing All Unserviceable Parts Like Diffuser, Nozzle, Electrodes, Solenoid Valve, Air Damper Adjustment, Gear Pump, Coupling Set, Oil Supply Pipe, Gasket, Ignition Transformer, Reset Button, Flame Detector And Controller And Supply And Fix Diffuser, Nozzle, Electrodes, Solenoid Valve, Air Damper Adjustment, Gear Pump, Coupling Set, Oil Supply Pipe, Gasket, Ignition Transformer, Reset Button, Flame Detector And Controller And Testing On Completion, Complete All As Specified And/Or As Directed By Engr-In-Charge. 30 Taking Down Unserviceable Burner Set Of Capacity 0.5/0.35 Lakh Kcal/Hr From Boiler And Removing All Unserviceable Parts Like Diffuser, Nozzle, Electrodes, Solenoid Valve, Air Damper Adjustment, Gear Pump, Coupling Set, Oil Supply Pipe, Gasket, Ignition Transformer, Reset Button, Flame Detector And Controller And Supply And Fix Diffuser, Nozzle, Electrodes, Solenoid Valve, Air Damper Adjustment, Gear Pump, Coupling Set, Oil Supply Pipe, Gasket, Ignition Transformer, Reset Button, Flame Detector And Controller And Testing On Completion, Complete All As Specified And/Or As Directed By Engr-In-Charge. 31 Taking Down Unserviceable Burner Set Of Capacity 1.5 Lakh Kcal/Hr From Boiler And Removing All Unserviceable Parts Like Diffuser, Nozzle, Electrodes, Solenoid Valve, Air Damper Adjustment, Gear Pump, Coupling Set, Oil Supply Pipe, Gasket, Ignition Transformer, Reset Button, Flame Detector And Controller And Supply And Fix Diffuser, Nozzle, Electrodes, Solenoid Valve, Air Damper Adjustment, Gear Pump, Coupling Set, Oil Supply Pipe, Gasket, Ignition Transformer, Reset Button, Flame Detector And Controller And Testing On Completion, Ccomplete All As Specified And/Or As Directed By Engr-In-Charge. 32 Taking Up/Down Pp-R Pipe Of Dia 40 Mm Dia From Trenches/Wall/Ceiling Incl Connected Fitting/Accessories Complete All As Specified And/Or As Directed By Engr-In-Charge. 33 Supply And Layinging 3-Layer Pp-R Polypropylene Random Copolymer Concealed Pipes Of Dia 40 Mm Size, Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or Laid In Floors Etc. Complete All As Specified And/Or As Directed By Engr-In-Charge. 34 Labour Only For Fixing Pp-R Pipe Of Dia 40Mm Complete To Walls, Ceilings Or Laid In Floors Etc.Complete All As Specified And/Or As Directed By Engr-In-Charge. 35 Taking Up/Down Pp-R Pipe Of Dia 32 Mm Dia From Trenches/Wall/Ceiling Incl Connected Fitting/Accessories Complete All As Specified And/Or Directed By Engr-In-Charge. 36 Supply And Laying 3-Layer Pp-R Polypropylene Random Copolymer Concealed Pipes Of Dia 32 Mm Size, Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. Complete All As Specified And/Or As Directed By Engr-In-Charge. 37 Labour Only For Fixing Pp-R Pipe Of Dia 32Mm Complete To Walls, Ceilings Or Laid In Floors Etc.Complete All As Specified And/Or As Directed By Engr-In-Charge. 38 Taking Up/Down Pp-R Pipe Of Dia 25 Mm Dia From Trenches/Wall/Ceiling Incl Connected Fitting/Accessories Complete All As Specified And/Or Directed By Engr-In-Charge. 39 Supply And Laying 3-Layer Pp-R Polypropylene Random Copolymer Concealed Pipes Of Dia 25 Mm Size, Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. Complete All As Specified And/Or As Directed By Engr-In-Charge. 40 Labour Only For Fixing Pp-R Pipe Of Dia 25Mm Complete To Walls, Ceilings Or Laid In Floors Etc.Complete All As Specified And/Or As Directed By Engr-In-Charge. 41 Taking Up/Down Pp-R Pipe Of Dia 20 Mm Dia From Trenches/Wall/Ceilig Incl Connected Fitting/Accessories Complete All As Specified And/Or Directed By Engr-In-Charge. 42 Supply And Laying 3-Layer Pp-R Polypropylene Random Copolymer Concealed Pipes Of Dia 20 Mm Size, Sdr 7.4 (Pn16) Uv Stabilized And Antimicrobial Fusion Welded Having Thermal Stability For Hot & Cold Water Supply Including All Pp-R Plain & Brass Threaded Polypropylene Random Fittings Fixed Complete To Walls, Ceilings Or In Floors Etc. Complete All As Specified And/Or As Directed By Engr-In-Charge. 43 Labour Only For Fixing Pp-R Pipe Of Dia 20Mm Complete To Walls, Ceilings Or Laid In Floors Etc.Complete All As Specified And/Or As Directed By Engr-In-Charge. 44 Material And Labour For Lagging For 25Mm Bore Dia Pipes To Be Used In Water Supply All Round With 40 Mm Thick Bonded Mineral Wool Preformed ‘Snap On’ Pipe Sections Of Density 144 Kgs / Cum Conforming To Is 9842 And Providing Chicken Mess Wire Netting Of 25 Guage 20 Mm Mesh And Covered With Aluminum Foil 0.01 Mm Complete All As Specified And/Or As Directed By Engr-In-Charge. 45 All As Per Srl Item No 44 Above, But For 40Mm Dia Bore Pipe. 46 All As Per Srl Item No 44 Above, But For 32Mm Dia Bore Pipe. 47 All As Per Srl Item No 44 Above, But For 20Mm Dia Bore Pipe. 48 Supply And Fix In Replacement Of Pvc Heavy Duty Vertical Type Fuel Storage Tank Of 50 Ltrs Capacity With Necessary Connection At Bottom For Fuel Pipe Of Suitable Size Complete All As Specified And/Or As Directed By Engr-In-Charge. 49 Supply And Fix In Replacement Of Under Deck Insulation With Puf Slab Including Application Of Cold Bitumen On Puf Slab, Steel Wire Of Size 46 Gauge Fixed For Fastening Of 60Mm Puf Slab, Suitable For Steel Sheet Duct Of Any Size Complete All As Specified And/Or As Directed By Engr-In-Charge. 50 Supply And Fix In Replacement Of Exhaust Fan (For Standalone Chs) Steel Body Ac Single Phase 230V Of Size 380 M Sweep With Blades, Frame And Louvers And Connecting With Flexible Three Core Cable From The Ceiling Rose Complete All As Specified And/Or As Directed By Engr-In-Charge. 51 Supply And Fix In Replacement Of Exhaust Fan ( For Standalone Chs) Steel Body Ac Single Phase 230V Of Size 450 M Sweep Heavy Duty With Blades, Frame And Louvers And Connecting With Flexible Three Core Cable From The Ceiling Rose Complete All As Specified And/Or As Directed By Engr-In-Charge. 52 Supply And Fix In Replacement Of Ducting For Hot Air Blower To Room Of Any Size With Complete Insulation Of 6 Mm Thick As Per Site Requirement Complete All As Specified And/Or As Directed By Engr-In-Charge. 53 Material And Labour For Earthing Complete With Galvanised Steel Plate Electrode 600X600X6.0Mm Buried Directly In The Ground Vertically To A Depth Not Less Than 2.25 Mtr With Top Edge Not Less Than 1.5 Mtr Below Ground Level Connected To And Including Gi Earth Wire 4 Mm Dia And Gi Pipe 15Mm Dia Light Grade For Earthing Protection To The Extend Of Max 7.5 Mtr Connected To The Plate By Mean Of Gi Bolts And Nuts And Further To Test Point By Provn Of Charcoal Salt Etc Complete With All As Per Ssr Electrical Plate No-3 Part -1 Including Pcc Chamber In Pcc 1:3:6 Type C-2 Frame Cover Ms Funnel Gi Watering Pipe Including Excavation In Any Strata Complete Incl Taking Out Of Old Unsv Earthing Complete All As Specified And/Or As Directed By Engr-In-Charge. 54 Excavation In Trenches Not Exc 1.5 M Wide And Not Exc 1.5 M In Depth And Getting It Out For Laying Of Cable / Pole In Hard/Dense Soil Complete All As Specified And/Or As Directed By Engr-In-Charge. 55 Material And Labour For Crushed Stone Sand Cushioning To Underground Cables 8 Cm Below The Cable Before Laying & 15 Cm Above The Cable After Laying, Complete All As Specified In Clause 19.75 Of Ssr Part-I, Complete All As Specified And/Or As Directed By Engr-In-Charge. Note : Punned Thickness Only Will Be Measured And Paid For. 56 Supply And Laying Of Factory Made, Machine Pressed, Unreinforced, Pre-Cast Concrete Cable Cover Class Lv Type-1 Flate Size 250Mm X 150Mm X 40Mm, Complete All As Specified And/Or As Directed By Engr-In-Charge. 57 Labour Only For Laying Of Old Serviceable Cable Covers Retrieved From Excavation Complete All As Specified And/Or As Directed By Engr-In-Charge. 58 Returning, Filling In, Including Spreading, Leveling Watering, And Well Ramming In Layers Not Exc 25 Cm In Hard/Dense Soil Complete All As Specified And/Or As Directed By Engr-In-Charge. 59 Removing Excavated Material Not Exc 50M And Depositing Where Directed At A Level Exc. 1.5 Cm Above The Starting Point Complete All As Specified And/Or As Directed By Engr-In-Charge. 60 Supply And Laying In Replacement Of Xlpe Insulated, Armoured, Heavy Duty Electric Cables With Stranded Aluminium Conductor Rating 1100 Volts Grade Of Size 25 Sqmm 4 Core Laid In Trenches Or Passing Through Pipes, Ducts Or Fixed To Walls/Poles Complete All As Specified And/Or Asdirected By Engr-In-Charge.
|