Tender for Supply And Commissioning Of Swas System - Analysers + S Le Handling System For Ntpc Talcher 2X660 Mw / Ntpc Lara 2 X 800 Mw / Ntpc Singrauli 2 X 800 Mw Projects , Primary Racks (With Ibr Certified Isolation Valves And Ibr Certified Ss316h Cooler Coils) Ntpc Talcher 2 X 660 Mw , Wet Panel - Enclosed Type Walkway Through Panel Ntpc Talcher 2 X 660 Mw , Dry Panel Ntpc Talcher 2 X 660 Mw , Chiller Unit - 2X100% Redundant - Min. 5 Tr Rating (With 25% Extra Capacity) Ntpc Talcher 2 X 660 Mw , Conductivity(Specific, Cation) Analyser - Single Channel Ntpc Talcher 2 X 660 Mw , Conductivity(Specific) Analyser For Hotwell - Single Channel Ntpc Talcher 2 X 660 Mw , Ph Analyser Transmitter- Single Channel Ntpc Talcher 2 X 660 Mw , Ph Analyser Sensor- Single Channel Ntpc Talcher 2 X 660 Mw , Dissolved Oxygen Analyser- Single Channel Ntpc Talcher 2 X 660 Mw , Dissolved Oxygen Sensor- Single Channel Ntpc Talcher 2 X 660 Mw , Sodium Analyser [Multi Channel(2 Channel)+1 Spare Channel] Ntpc Talcher 2 X 660 Mw , Silica Analyser [Multi Channel (4 Channel) +1 Spare Channel] Ntpc Talcher 2 X 660 Mw , Degassed Cation Conductivity Analyser Ntpc Talcher 2 X 660 Mw , Turbidity Analyser Single Channel Ntpc Talcher 2 X 660 Mw , Total Iron Analyser Single Channel Ntpc Talcher 2 X 660 Mw , Hydrazine Analyser - Single Channel Ntpc Talcher 2 X 660 Mw , Loose Supply Items As Per Annexure-A Ntpc Talcher 2 X 660 Mw , Mandatory Spares As Per Annexure- B - Shs Ntpc Talcher 2 X 660 Mw , Mandatory Spares As Per Annexure- B - Analysers Ntpc Talcher 2 X 660 Mw , Commissioning Spares- Reagents / Consumables / Calibratiors / Standard Solution As Required For Commissioning & Handing Over Of System To Owner Ntpc Talcher 2 X 660 Mw , Chemical Reagents, Consumables And Standard Solutions For 18 Months Of Operation Ntpc Talcher 2 X 660 Mw , Annunciator - Microprocessor Based Minimum 96 Points, Window Size : 70 Mm X 50 Mm Ntpc Talcher 2 X 660 Mw , O & M Manuals / Documentation Charges Ntpc Talcher 2 X 660 Mw , Supervision Of Erection, Total Commissioning And Handing Over Of Swas System Ntpc Talcher 2 X 660 Mw , Price For One Line Of High Pressure & High Temp. - Primary & Secondary Cooling To Be Considered Along With Other Instruments As Per P&Id Applicable For The Project. Ntpc Talcher 2 X 660 Mw , Price For One Line Of Low Pressure & Low Temp. - Secondary Cooling To Be Considered Along With Other Instruments As Per P&Id Applicable For The Project. Ntpc Talcher 2 X 660 Mw , Freight Charges For Ntpc Talcher 2 X 660 Mw (Lump Sum) , Primary Racks (With Ibr Certified Isolation Valves And Ibr Certified Ss316h Cooler Coils) Ntpc Lara 2 X 800 Mw , Wet Panel - Enclosed Type Walkway Through Panel Ntpc Lara 2 X 800 Mw , Dry Panel Ntpc Lara 2 X 800 Mw , Chiller Unit - 2X100% Redundant - Min. 5 Tr Rating (With 25% Extra Capacity) Ntpc Lara 2 X 800 Mw , Conductivity(Specific, Cation) Analyser - Single Channel Ntpc Lara 2 X 800 Mw , Conductivity(Specific) Analyser For Hotwell - Single Channel Ntpc Lara 2 X 800 Mw , Ph Analyser Transmitter- Single Channel Ntpc Lara 2 X 800 Mw , Ph Analyser Sensor- Single Channel Ntpc Lara 2 X 800 Mw , Dissolved Oxygen Analyser- Single Channel Ntpc Lara 2 X 800 Mw , Dissolved Oxygen Sensor- Single Channel Ntpc Lara 2 X 800 Mw , Sodium Analyser [Multi Channel(2 Channel)+1 Spare Channel] Ntpc Lara 2 X 800 Mw , Silica Analyser [Multi Channel (4 Channel) +1 Spare Channel] Ntpc Lara 2 X 800 Mw , Hydrogen Analyser - Single Channel Ntpc Lara 2 X 800 Mw , Degassed Cation Conductivity Analyser Ntpc Lara 2 X 800 Mw , Turbidity Analyser Single Channel Ntpc Lara 2 X 800 Mw , Total Iron Analyser Single Channel Ntpc Lara 2 X 800 Mw , Loose Supply Items As Per Annexure-A Ntpc Lara 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Shs Ntpc Lara 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Analysers Ntpc Lara 2 X 800 Mw , Commissioning Spares- Reagents / Consumables / Calibratiors / Standard Solution As Required For Commissioning & Handing Over Of System To Owner Ntpc Lara 2 X 800 Mw , Chemical Reagents, Consumables And Standard Solutions For 18 Months Of Operation Ntpc Lara 2 X 800 Mw , Annunciator - Microprocessor Based Minimum 96 Points, Window Size : 70 Mm X 50 Mm Ntpc Lara 2 X 800 Mw , O & M Manuals / Documentation Charges Ntpc Lara 2 X 800 Mw , Supervision Of Erection, Total Commissioning And Handing Over Of Swas System Ntpc Lara 2 X 800 Mw , Freight Charges For Ntpc Lara 2 X 800 Mw (Lump Sum) , Primary Racks (With Ibr Certified Isolation Valves And Ibr Certified Ss316h Cooler Coils) Ntpc Singrauli 2 X 800 Mw , Wet Panel - Enclosed Type Walkway Through Panel Ntpc Singrauli 2 X 800 Mw , Dry Panel Ntpc Singrauli 2 X 800 Mw , Chiller Unit - 2X100% Redundant - Min. 5 Tr Rating (With 25% Extra Capacity) Ntpc Singrauli 2 X 800 Mw , Conductivity(Specific, Cation) Analyser - Single Channel Ntpc Singrauli 2 X 800 Mw , Conductivity(Specific) Analyser For Hotwell - Single Channel Ntpc Singrauli 2 X 800 Mw , Ph Analyser Transmitter- Single Channel Ntpc Singrauli 2 X 800 Mw , Ph Analyser Sensor- Single Channel Ntpc Singrauli 2 X 800 Mw , Dissolved Oxygen Analyser- Single Channel Ntpc Singrauli 2 X 800 Mw , Dissolved Oxygen Sensor- Single Channel Ntpc Singrauli 2 X 800 Mw , Sodium Analyser [Multi Channel(2 Channel)+1 Spare Channel] Ntpc Singrauli 2 X 800 Mw , Silica Analyser [Multi Channel (4 Channel) +1 Spare Channel] Ntpc Singrauli 2 X 800 Mw , Hydrogen Analyser - Single Channel Ntpc Singrauli 2 X 800 Mw , Degassed Cation Conductivity Analyser Ntpc Singrauli 2 X 800 Mw , Turbidity Analyser Single Channel Ntpc Singrauli 2 X 800 Mw , Total Iron Analyser Single Channel Ntpc Singrauli 2 X 800 Mw , Loose Supply Items As Per Annexure-A Ntpc Singrauli 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Shs Ntpc Singrauli 2 X 800 Mw , Mandatory Spares As Per Annexure- B - Analysers Ntpc Singrauli 2 X 800 Mw , Commissioning Spares- Reagents / Consumables / Calibratiors / Standard Solution As Required For Commissioning & Handing Over Of System To Owner Ntpc Singrauli 2 X 800 Mw , Chemical Reagents, Consumables And Standard Solutions For 18 Months Of Operation Ntpc Singrauli 2 X 800 Mw , Annunciator - Microprocessor Based Minimum 96 Points, Window Size : 70 Mm X 50 Mm Ntpc Singrauli 2 X 800 Mw , O & M Manuals / Documentation Charges Ntpc Singrauli 2 X 800 Mw , Supervision Of Erection, Total Commissioning And Handing Over Of Swas System Ntpc Singrauli 2 X 800 Mw , Freight Charges For Ntpc Singrauli 2 X 800 Mw (Lump Sum)
|