Iae. Thermoelectrode Wire Ptn Xk 2X0.3. Functional, Technical, Quality, Performance Characteristics: The Ptn Xk Wire Is Intended For Use As An Extension Wire Of A Thermoelectric Converter. Can Be Used In High Temperature Zones With Fixed Installation And No Mechanical Load On The Insulation. Number Of Cores, Pcs. – 2. Electrode Material - Chromel - Copel. Core Diameter, Mm – 0.3. Insulation – Silica Thread (Fiberglass). Shell – Silica Thread (Fiberglass). The Wire Is Designed For Operation At Ambient Temperatures From -60°С To +600°С And Maximum Permissible Humidity Up To 80% At Temperatures Up To +35°С. Delivery In A Coil 60 M Long. Certificate., Iae. Thermocouple Cable Ktms Xa 2X0.03 D1 Mm. Functional, Technical, Quality, Performance Characteristics: The Cable Is Intended For The Manufacture Of Thermoelectric Converters, Which Are Used To Measure Temperatures In The Range From Minus 60°C To Plus 1100°C. The Cable Consists Of Thermoelectrode Cores, Which Are Enclosed In A Stainless Steel Sheath. The Thermoelectrode Cores Are Arranged In Parallel And Insulated With Mineral Insulation - Periclase Or Magnesium Oxide. The Cable Sheath Must Be Made Of Stainless Steel Aisi 321 Or Its Equivalent - Steel 12Х18н10т. The Cable Sheath Must Be Resistant To Shock And Crushing. The Shell Should Not Have Holes Or Cracks. The Material Of Thermoelectrode Cores Is Chromel – Alumel. Number Of Thermoelectrode Cores, Pcs. – 2. Cross-Sectional Area Of Thermoelectrode Cores, Mm2 – 0.03. Nominal Outer Diameter Of The Cable (Steel Sheath), Mm – 1. Delivery In Coils With A Length Of At Least 50 M. Certificate., Iae. Cable Knmsnh-N 1X0.159 D2.0 Mm. Functional, Technical, Quality And Performance Characteristics: The Knmsnkh-N Cable Is Intended For The Manufacture Of Heating Elements And Electric Heating Devices. The Cable Must Have A Design With One Heating Core Placed In A Metal Sheath And Insulated From The Sheath With Mineral Insulation Based On Magnesium Oxide (Mgo). The Heating Core Material Is A Nichrome Alloy, Which Ensures Stability Of Electrical Resistance And Heating Characteristics At High Temperatures. The Cable Sheath Must Be Made Of Corrosion-Resistant Stainless Steel Grade 08Х18н10т, 12Х18н10т Or An Equivalent Material That Provides Performance Characteristics Not Lower Than Those Specified. The Shell Must Be Resistant To Shock, Vibration, Bending And Crushing. Cracks, Holes, Delaminations, Traces Of Corrosion And Other Defects That Impair The Performance Characteristics Of The Product Are Not Allowed On The Surface Of The Shell. Cable Brand - Knmsnh-N. Number Of Heating Cores - 1. Heating Core Material - Nichrome Alloy. The Cross-Sectional Area Of The Core Is 0.159 Mm². The Nominal Outer Diameter Of The Cable Is 2.0 Mm. Insulation - Mineral (Magnesium Oxide, Mgo). Shell Material - Stainless Steel 08Х18н10т, 12Х18н10т Or Equivalent. Delivery In A Coil Of At Least 50 M Length. Certificate., Iae. Thermoelectrode Wire Ptn Xa 2X0.3. Functional, Technical, Quality, Performance Characteristics: The Ptn Xa Wire Is Intended For Use As An Extension Wire Of A Thermoelectric Converter. Can Be Used In High Temperature Zones With Fixed Installation And No Mechanical Load On The Insulation. Number Of Cores, Pcs. – 2. Electrode Material - Chromel - Alumel. Core Diameter, Mm – 0.3. Insulation – Silica Thread (Fiberglass). Shell – Silica Thread (Fiberglass). The Wire Is Designed For Operation At Ambient Temperatures From -60°C To +800°C And Maximum Permissible Humidity Up To 80% At Temperatures Up To +35°C. Delivery In Coils Of At Least 50 M Length. Certificate., Iae. Knmss Cable 2X0.06 D1.5 Mm. Functional, Technical, Quality And Performance Characteristics: The Knmss Cable Is Designed For Transmitting Electrical Signals And Power Supply As Part Of Measuring, Control And Experimental Systems Operating Under Conditions Of Elevated Temperatures, Mechanical Loads, Vibration, High Humidity And Ionizing Radiation. The Cable Must Have Two Conductive Cores, Insulated From Each Other And From The Metal Sheath With Mineral Insulation Based On Magnesium Oxide (Mgo). The Cable Design Must Ensure High Reliability, Tightness, Mechanical Strength And Stability Of Electrical Characteristics Throughout Its Entire Service Life. The Cable Sheath Must Be Made Of Corrosion-Resistant Stainless Steel Grade 08Х18н10т, 12Х18н10т Or An Equivalent Material That Provides Performance Characteristics Not Lower Than Those Specified. The Shell Must Be Resistant To Shock, Vibration, Bending And Crushing. The Presence Of Cracks, Holes, Traces Of Corrosion And Other Defects That Impair The Performance Characteristics Of The Product Is Not Allowed. Cable Brand - Knmss. Number Of Cores - 2. Cross-Sectional Area Of Each Core - 0.06 Mm². Core Material - Stainless Steel. The Nominal Outer Diameter Of The Cable Is 1.5 Mm. Insulation - Mineral (Magnesium Oxide, Mgo). Shell Material - Stainless Steel. Delivery In Coils With A Length Of At Least 50 M. Certificate., Iae. Cable Knmsnkh-N 1X0.283 D3.0 Mm. Functional, Technical, Quality And Performance Characteristics: The Knmsnkh-N Cable Is Intended For The Manufacture Of Heating Elements And Electric Heating Devices. The Cable Must Have A Design With One Heating Core Placed In A Metal Sheath And Insulated From The Sheath With Mineral Insulation Based On Magnesium Oxide (Mgo). The Heating Core Material Is A Nichrome Alloy, Which Ensures Stability Of Electrical Resistance And Heating Characteristics At High Temperatures. The Cable Sheath Must Be Made Of Corrosion-Resistant Stainless Steel Grade 08Х18н10т, 12Х18н10т Or An Equivalent Material That Provides Performance Characteristics Not Lower Than Those Specified. The Shell Must Be Resistant To Shock, Vibration, Bending And Crushing. Cracks, Holes, Delaminations, Traces Of Corrosion And Other Defects That Impair The Performance Characteristics Of The Product Are Not Allowed On The Surface Of The Shell. Cable Brand - Knmsnh-N. Number Of Heating Cores - 1. Heating Core Material - Nichrome Alloy. The Cross-Sectional Area Of The Core Is 0.283 Mm². The Nominal Outer Diameter Of The Cable Is 3.0 Mm. Insulation - Mineral (Magnesium Oxide, Mgo). Shell Material - Stainless Steel 08Х18н10т, 12Х18н10т Or Equivalent. Delivery In Coils Of At Least 50 M Length. Certificate., Iae. Thermocouple Cable Ktms Xk 2X0.06 D1.5 Mm. Functional, Technical, Quality, Performance Characteristics: The Cable Is Intended For The Manufacture Of Thermoelectric Converters, Which Are Used To Measure Temperatures In The Range From Minus 60°C To Plus 600°C. The Cable Consists Of Thermoelectrode Cores, Which Are Enclosed In A Stainless Steel Sheath. The Thermoelectrode Cores Are Arranged In Parallel And Insulated With Mineral Insulation - Periclase Or Magnesium Oxide. The Cable Sheath Must Be Made Of Stainless Steel Aisi 321 Or Its Equivalent - Steel 12Х18н10т. The Cable Sheath Must Be Resistant To Shock And Crushing. The Shell Should Not Have Holes Or Cracks. The Material Of Thermoelectrode Cores Is Chromel – Copel. Number Of Thermoelectrode Cores, Pcs. – 2. Cross-Sectional Area Of Thermoelectrode Cores, Mm2 – 0.06. Nominal Outer Diameter Of The Cable (Steel Sheath), Mm – 1.5. Delivery In Coils Of At Least 50 M Length. Certificate.
|