Execution Of Construction Works And Post-Construction Inventory Through Adaptation Of The Building Of The Social Welfare Home At Ul. Kurasia 7 In Tarnobrzeg To The Existing Fire Protection Regulations In The Scope Of: - Dismantling Supporting Structures For Boxes By Drilling Holes Or Unscrewing Them (Applies To Existing Smoke Detectors, Rops And Fire Protection Control Panel), - Piercing Holes In Walls Or Ceilings, - Laying Cables In Ready-Made Grooves On A Surface Other Than Concrete, - Screwing Pvc Electrical Installation Strips On Bricks, - Embedding Plastic Expansion Bolts And Metal Dowels Shot Into Walls Or Ceilings, - Installing A Compact Alarm Control Panel - Fire Alarm Control Panel, - Installing Power Supplies (Up To 12V Dc), Up To 6.5W - Smoke Exhaust/Fire Door Control Panel, - Dismantling All Fire Detectors And Installations, All Smoke Detectors Are Not Isotope Detectors, - Addressable Installation, Universal, Optical Scattered Smoke Detectors, - Installation Of Addressable Multi-Sensor Smoke And Heat Detectors, - Installation Of Addressable Heat Detectors, - Installation Of Manual Fire Alarms, - Installation Of Manual Smoke Exhaust Buttons - Installation Of Acoustic And Optical Alarms, - In Addition To The Basic Design And Bill Of Quantities, As-Built Documentation Must Be Prepared, Agreed With The Fire Protection Expert And Signed By Designers Of A Given Industry, Along With A Certificate Of Correct Execution For All Performed Works, - Smoke Exhaust Flaps Should Be Installed In 3 Staircases And Appropriate Automation Should Be Installed To Control The Opening Of The Air Intake Doors, In Accordance With The Attached Drawing With The Following Parameters: • Staircase Segment A: Active Area Of The Flap At Least 1.4 M2, Aeration Area Of At Least 2.6 M2 Through The Door Open At An Angle Of 90 Degrees • Middle Staircase Segment C: Active Area Of The Damper At Least 1.2 M2, Area Aeration Area Of Min. 1.72 M2 Through The Door Open At An Angle Of 90 Degrees• Lower Cage, Segment C: Active Area Of The Flap Min. 1.2 M2, Aeration Area Of Min. 2.23 M2 Through The Door Open At An Angle Of 90 Degrees, The Door Must Open Automatically, - Colliding Doors In The Fire Zone Of The Staircase Must Be Properly Eliminated, .... - External Doors Should Be Replaced With Air Intake Doors With Parameters Consistent With The Technical Conditions For External Partitions Equipped With Appropriate Actuators, - Automatic Flap Control Connected To The New Fire Control Panel Should Be Installed And Its Retrofitting Should Be Planned, - They Should Be Secured At The Transitions Between Fire Zones, - A Fire Scenario Should Be Prepared, - The Buildings Fire Safety Manual Should Be Updated, Note: 1. Within The Scope Of The Order, The Contractor Must Estimate The Costs Of Accompanying Works Related To Damage Caused During The Execution Of The Works (Including Plastering, Filling, Painting).2. The Contractor Should Take Into Account That The Works Will Be Carried Out In An A
|