Medical Consumables – Digital Mammography System 2D. Digital Mammography System 2D Minimum Product Characteristics No. Specification Item 1 Bucky 1.1 Motorized Vertical Displacement Range ≥ 55 Cm To Ensure Easy Patient Access In Sitting, Lying, And Standing Positions. 1.2 Two Touchscreen Control Panel Monitors For Adjusting Position And Compression, One On Each Side. 1.3 Anti-Scatter Grid With A Density ≥ 30 L/Cm. 1.4 System For Additional Breast Retraction Into The Acquisition Field For Better Analysis. State The Name Of The Offered Option. 2 Generator 2.1 Built Into The Stand Of The Device Due To Space Limitations. 2.2 High-Frequency Generator ≥ 100 Khz. 2.3 Maximum Power ≥ 4.5 Kw. 2.4 Maximum Mas Value ≥ 600 Mas To Obtain High-Quality Images Even For High-Density And Large-Sized Breasts. 2.5 Maximum Ma Value ≥ 120 Ma. 2.6 Kv Range: Minimum Range From 23 To 35 Kv. 2.7 Separate Exposure Mode For Breasts With Implants. 2.8 Automatic Power Supply Voltage Compensation. 3 X-Ray Tube Assembly Holder 3.1 Motorized Rotation Range ≥ 315°. 3.2 Isocentric Motorized Rotation Of The C-Arm So That The Center Of The Detector Always Remains At The Same Height, Reducing Patient Positioning Time. 3.3 Heat Capacity Of The X-Ray Tube Assembly Holder ≥ 700 Khu. 3.4 Source-To-Image Receptor Distance (Sid) ≥ 65 Cm To Allow Higher Geometric Resolution And Easier Patient Positioning. 3.5 Manual And Automatic Adjustment Of Breast Compression. 3.6 Automatic Motorized Collimator Adjustment. 3.7 Compression Plate With Minimum Dimensions Of 18 X 23 Cm. 3.8 Compression Plate With Minimum Dimensions Of 24 X 30 Cm. 3.9 Display Of Adjusted Exposure Parameters: Kv, Mas, Compression Force, And Breast Thickness. 3.10 Automatic Exposure Control. 3.11 Automatic And Manual Release Of Compression Plates After Imaging. 3.12 Magnification Factor Minimum 1.6X. 4 X-Ray Tube 4.1 Minimum Two Focal Spots; Small Focal Spot Not Larger Than 0.1 Mm; Large Focal Spot Not Larger Than 0.3 Mm. 4.2 Rotating Anode. 4.3 Anode Rotation Speed ≥ 9600 Rpm. 4.4 Anode Heat Capacity ≥ 300 Khu. 4.5 Dual Motorized Filters. 4.6 Automatic And Manual Collimation. 4.7 Automatic Identification Of Attached Compression Plates And Fov Adjustment. 5 Detector 5.1 New Generation Digital Detector Made Of Amorphous Selenium Or Amorphous Silicon With Cesium Iodide. 5.2 Active Area Size Of The Detector Minimum 230 Mm X 295 Mm. 5.3 Image Matrix Resolution Minimum 2800 X 3580 Pixels. 5.4 Pixel Size ≤ 85 Μm. 5.5 Must Be Capable Of Operating Within A Minimum Temperature Range Of 13°C To 35°C To Ensure Seamless System Operation Under Local Conditions. 5.6 A/D Conversion Minimum 16 Bit. 5.7 Spatial Resolution Minimum 6 Lp/Mm. 6 Acquisition Station 6.1 Computer With Minimum 8Gb Ram. 6.2 Internal Storage (Hard Drive Or Ssd) Minimum 1Tb Size. 6.3 Internal Storage Capacity For A Minimum Of 40,000 Images On The Acquisition Workstation. 6.4 Dicom Monitor With A Minimum Size Of 23 Inches And Minimum Resolution ≥ 2 Megapixels. 6.5 Saving Images To Cd/Dvd In Dicom Format Or Equiva
Contact Information
Address
Goce Delcev 80-13 Kratovo 1360 1360
Contact No.
+38978321038
Email
zd_kratovo@yahoo.com
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 116766463
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.