|
Bids Are invited for Facility Management Services - Lumpsum Based - Government Office; Sitc Of Elevator With Civil And Electric Work; Consumables To Be Provided By Service Provider (Inclusive In Contract Cost) - Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Steel Conduit,With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface/ Recessed Medium Class Pvc Conduit As Required. , Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required. , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate & Switch Box Excluding Modular Plate As Required. , Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc. As Required. , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/6 A Modular Switch, Connections Etc. As Required. , Supplying And Fixing Following Way, Horizontal Type Three Pole And Neutral (Tpn), Sheet Steel, Mcb Distribution Board, 415 V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) , Supplying And Fixing Of Following Ways Surface/ Recess Mounting, Vertical Type, 415 V, Tpn Mcb Distribution Board Of Sheet Steel, Dust Protected, Duly Powder Painted, Inclusive Of 200 A Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcbs (But Without Mcbs And Incomer ) As Required . (Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required.) , Supplying And Fixing 5 A To 32 A Rating, 240/415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. , Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connections, Etc. As Required. , Supplying And Fixing Tp Sheet Steel Enclosure On Surface/ Recess Along With 16/25/32 A 415 V C Curve Tp Mcb Complete With Connections, Testingand Commissioning Etc. As Required. , Supply And Fixing Of 63 . Tp Mcb (10 Ka) C Curve. Cat A , Supply And Fixing Of 40 . Fp Mcb (10 Ka) C Curve. Cat A , Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral) Spn, 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required. (Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) , Supplying And Laying Of 6 Swg G.I Wire At 0.50 Metre Below Ground Level For Conductor Earth Electrode, Including Connection / Terminating With G.I. Thimble Etc. As Required. , Supplying, Installation, Testing & Commissioning Of 18 Watt Led Recessed/Surface Down Lighter (Round / Square/ Rectangular) Cob Type And Construction As Per Is : 10322 With Driver As Per The Requirement Complete In All Respect. Led Down Lighter (Cob Type) (System Lumen Efficacy =120 Lm/Watt ) , Excavation In Foundations In Ordinary Soil (Loam Clay Or Sand) Including Lift Upto 1.5 M (5 Fts.) And Lead Upto 30 Mt. (100 Fts.) & Including Filling, Watering And Ramming Of Excavated Earth Into The Trenches Or Into The Space Between The Building And The Sides Of Foundation Trenches Or Into The Plinth And Removal And Disposal Of Surplus Earth As Directed By The Engineer-Incharges Upto A Distance Of 30Mt. (100 Fts) From The Foundation Trenches. , Providing And Laying Cement Concrete 1:4:8 (1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size) Including Supply Of All Materials, Labour T & P Rtc Required For Proper Completion Of The Work And Curing Complete Also Including Cost Of Formwork In Foundation & Floors. , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chaijjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Up To 15° Landings, Balconies, Shelves, Chaijjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Above Plinth Level Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With 1:1.5:3 (1 Cement : 1.5 Coarse Sand(Zone-Lll) Derived From Natural Sources : 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , M-150 Brick Work In Super-Structure Above Plinth Level Up To Floor Two Level (Up To Two Storeys) Including Necessary Cutting And Moulding Of Bricks As Required. (1:4 Cement & Coarse Sand) , Tmt Fe-500 Or Iron In Plain Work Such As Reinforced Concrete Or Reinforced, Brick Work (When Not Included In Over All Rates ) Wrought To Required Shape As Necessary Including Bending For Proper Completion Of The Work And Including Supply Of All Steel And And Over Lapping & Hooks. , 15 Mm Cement Plaster In Single Coat On Rough Side Of Single Or Half Brick Wall For Interior Plastering Up To Floor Two Level Including Internal Rounded Angles Not Exceeding 80 Mm In Girth And Finshed Even And Smooth. (1) 1 Cement : 6 Coarse Sand , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. (Area Of Slab Over 0.50 Sqm) , Providing And Fixing 18 Mm Thick Gang Saw Cut, Mirror Polished, Premoulded And Prepolished, Machine Cut For Kitchen Platforms, Vanity Counters, Window Sills , Facias And Similar Locations Of Required Size, Approved Shade, Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand), Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. (Area Of Slab Upto 0.50 Sqm) , Distempering (Two Coat) With Oil Bound Distemper Of Approved Brand And Manufacture & Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over & Including A Priming Coat With Cement Primer Of Approved Brand & Manufacture Such As Berger,J&N, Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Droppings & Other Foreign Matters & Also Including Preparing The Surface Even With Plaster Of Paris Or Approved Synthetic Material & Sand Papered Smooth Including Cost Ofall Materials. (Ceiling) , Providing And Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand & Anufacturer, Over The Plastered Wall Surface To Prepare The Surface Even & Smooth Complete. , Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : , Steel Reinforcement Work In Rebaring , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge. , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. Hot Finished Seamless Type Tubes , Passenger Lift G+3, 4 Stop , 15 Person
|