Tender for Supply, Installation, Commissioning & Testing Of Latest Online Water Quality Analyzers, Rotameters, Flow Meters And Centralized Monitoring System For Dm Plant At Unit No. 5, 210 Mw Atps Mppgcl Chachai. , Analyzers , Dual Channel Conductivity Analyser Complete Set With All Accessories For Differential Cation Conductivity. Calibration Range: 0-50 ?s/Cm Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 , Single Channel Conductivity Analyser Complete Set With All Accessories. Calibration Range: 0-50 ?s/Cm Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 , Dual Channel Analyzer (Conductivity + Ph ) Complete Set With All Accessories. Conductivity Calibration Range: 0-10 ?s/Cm Ph Calibration Range: 0-14 Ph Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 , Dual Channel Analyzer (Conductivity + Ph ) Complete Set With All Accessories. Conductivity Calibration Range: 0-1 ?s/Cm Ph Calibration Range: 0-14 Ph Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbuscommunication Protocol : Rs-485 , Single Channel Ph Analyzer Ph Calibration Range: 0-14 Ph Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbuscommunication Protocol : Rs-485 , Silica Analyzer , Silica Analyzer Alongwith Complete Set Of All Accessories, Reagents Etc. Input Power Supply : 230 V Ac, 50 Hz Analog Output : 4-20 Ma Modbus Communication Protocol : Rs-485 Channels Location: 1. Sba- A Outlet 2. Mb- A Outlet 3. Sba- B Outlet 4. Mb- B Outlet , Rotameters/ Varible Area Flowmeters (For Dm Plant) , Bypass Rotameter Accuracy : ± 2% Of Full Flow, Moc Of Orifice Plate: Ss316, Moc Of Float : Ss316, Moc Of Float Retainer : Ss316, Moc Of Body : Ms Powder Coating, Moc Of Packing : Ptfe, Moc Of Measuring Tube : Borosilicate Toughened Glass, Wetted Parts: Ss316 Type Of Tapping : Corner Tapping (Carrier Rings), Range Of Rotameter : 16.0-80.0 M3/Hr, Output Pressure : 4-5 Kg/Cm2, Output Flow : 41-42 M3/Hr, Max. Flow : 46-47 M3/Hr, Line Size : 100 Nb, Pipe Id : 97.2-100 Mm, Pipe Od : 114 Mm, Tube Size : Pg-3 (For Normal Pressure Application), B- Ratio : 0.6-0.7 , Online Rotameters , Accuracy : ± 2% Of Full Flow, Moc Of Float : Ss316, Moc Of Float Retainer : Ss 316, Moc Of Body : Ms Powder Coating, Moc Of Packing : Ptfe, Moc Of Measuring Tube : Borosilicate Toughened Glass, Line Size: 50Nb, Wetted Parts: Ss316 Type Of Connection : Flange Type, Housing Protection Class : Ip-65 , Orientation : Inlet Connection - Bottom, Outlet Connection : Top, Range Of Rotameter : 0.6 - 6 M3/Hr, Output Pressure : 4.5 Kg/Cm2, Output Flow : 3.34-4.2 M3/Hr, Meter Size : 50 Nb, Flange Size : 40, Pipe Id : 33.9 Mm, Pipe Od : 48 Mm , Accuracy : ± 2% Of Full Flow, Moc Of Float : Ss316, Moc Of Float Retainer : Ss 316, Moc Of Body : Ms Powder Coating, Moc Of Packing : Ptfe, Moc Of Measuring Tube : Borosilicate Toughened Glass, Line Size: 50Nb Type Of Connection : Flange Type, Housing Protection Class : Ip-65 , Orientation : Inlet Connection - Bottom, Outlet Connection : Top, Range Of Rotameter : 1.6 - 16 M3/Hr, Output Pressure : 4-4.5 Kg/Cm2, Output Flow : 9.35-10.5 M3/Hr, Meter Size : 80 Nb, Flange Size : 50, Pipe Id : 45 Mm, Pipe Od : 60 Mm , Flowmeters With Totalizer , Type: Vortex Flow Meter Pipe Line Size : 100 Nb Pipe Line Material : Msrl Pipe Line Od : 114 Mm, Id : 97.2 Mm Flow : 0 - 75 M3/Hr Process Liquid : Dm Water , Type: Vortex Flow Meter Pipe Line Size : 80 Nb Pipe Line Material : Msrl Pipe Line ; Od : 90 Mm, Id : 80 Mm Flow : 0 - 75 M3/Hr Process Liquid : Dm Water , Type: Electromagnetic Flow Meter Pipe Line Size : 200 Nb Pipe Line Material : Erw Ms Pipe Line : Od =218 Mm ; Id : 200Mm Flow : 310 M3/Hr Discharge Head : 25 M Process Liquid : Clarified Water , Type: Electromagnetic Flow Meter Pipe Line Size : 150 Nb. Pipe Line Material : Erw Ms Pipe Line : Od =168 Mm ; Id : 150Mm Flow : 120 M3/Hr Discharge Head : 30 M Process Liquid : Clarified Water , Centralized Monitoring System Of Dm Plant Comprises Of Industrial Grade Pc, Screen/Monitor, Connectivity System Etc. , Ups System 2 X 10Kva (Hot-Standby Configuration) With Single Battery Bank, Alkaline Battery Bank Is To Be Supplied For At Least 10 Hour Power Backup. Input Power Supply : 230 V Ac Single Phase. Output Power Supply : 230 V Ac Single Phase. Ups Properties: 1) Master & Slave And Auto Changeover On Fault 2) If Both Ups Failed, Auto Switchover On Auxiliary Power Supply , Power Cable For All Instruments Three Core 2.5 Sq.Mm Multi Strand Copper 230Vac Armoured , Control Cable For All Instruments Communication Cable Rs-485 , Two Core, Four Pair , 01 Sq.Mm Armoured , Installation & Commissioning Of Whole System As Per Scope Of Work , annual maintenance contract Charges For 03 Years (Minimum 02 Days Per Visit Only) , For 1St Year (Total 3 Visit Per Year) , For 2Nd Year (Total 3 Visit Per Year) , For 3Rd Year (Total 3 Visit Per Year)
|