Tender For Provision Of Certain Sanction Works In The Area Of Age B/R-I And Age E/M Under Ge (Central), Delhi Cantt-10- 1 Surface Dressing N Exc 15 Cm Deep 2 Surface Excavation N.Exc (Not Exceeding) 30 Cm Deep And Averaging 15Cm Deep And Getting Out In Hard/Dense Soil Complete All As Specified And Directed. 3 Removal Of Surplus Soil To A Distance N.Exc 50 M And Depositing Where Directed At Level Not Exceeding 1.5 M Above The Starting Point Complete All As Specified & Directed By Engineer-In-Charge. 4 M&L Pcc 1:4:8 Type D2 Using 40Mm Graded Stone Aggregates As In Foundation Complete All As Specified And As Directed. 5 M&L, Pcc 1:3:6 Type C-2 Using 40Mm Graded Stone Aggregate As In Foundation, Fitting And Mass Concrete 6 M&L For Cement Concrete 1:2:4 Type B1 (Using 12.5Mm Graded Stone Aggregate) On Surface Finished Even And Smooth Without Using Extra Cement Complete All As Spd & Directed. 7 Supply And Application Of Acrylic Sports Flooring System On Prepared Concrete/Pcc Surface For Badminton Court (Indoor/Outdoor), Including All Materials, Labor, Equipment, And Necessary Primer, Base Coats, Finish Coats, And Line Marking As Per Badminton World Federation (Bwf) Standards.- Primer: One Coat Of Acrylic Primer Suitable For Cementitious Surfaces. Coverage: 8-10 Sqm Per Liter.- Base Coats: 2-3 Layers Of Acrylic Resin-Based Cushion Or Non-Cushion Base Coat, As Per Design. Each Coat 1-2 Mm Thickness. Typically 1.5-2.0 Kg Per Sqm Per Coat.- Finish Coats: 2 Layers Of Acrylic Color Finish Coat, Uv Stable, Non-Slip, With A Total Thickness Of 1-2 Mm. Color As Per Client Choice (Typically Green, Blue, Or Red). Coverage: 1.0-1.5 Kg Per Sqm Per Coat.- Line Marking: 50 Mm Wide Lines Using Acrylic Line Paint, White Or Contrasting Color, As Per Standard Badminton Court Dimensions.- Additives: Anti-Slip Additives, If Required, To Meet Sports Surface Standards.- Surface Preparation: Ensure Concrete/Pcc Is Clean, Dry, Free Of Dust, Oil, And Loose Particles. Repair Cracks And Level Uneven Areas.- Application Of Primer: Apply Evenly And Allow To Dry As Per Manufacturer’S Instructions (Typically 4-6 Hours).- Apply Base Coats: Spread Acrylic Base Coats Uniformly, Allow Each Layer To Cure (24 Hours Typically) Before Next Application.- Apply Finish Coats: Apply Two Coats Of Acrylic Finish, Ensuring Smooth, Even Surface. Allow 24 Hours Between Coats.- Line Marking: Mark Lines Accurately As Per Badminton Court Dimensions (13.4M X 6.1M For Singles, 13.4M X 7.6M For Doubles). Ensure Paint Is Dry Before Use.- Curing: Allow Final Surface To Cure For 48-72 Hours Before Use - Measurement: Area In Square Meters (Sqm) Of Acrylic Flooring Applied.- Payment: Per Square Meter Rate Includes All Materials, Labor, Equipment, Surface Preparation, Application, And Line Marking. 8 S&F Mild Steel Work As In Compound Girders ,Postand Stanchions, Latticegirders, Aerial Masts, Staging For Water Tanks And Like Including Caps Bases, Splices Etc Built Up From Two Or More Beam Or Channel Sections Or Angles With Gusset Plates, Or Nutt Bolt Or Pipe Section Including All Lattice Bars, Stiffeners, Gusset Plates Etc..(Fe-410-W(Gde E-250)Quality-A) 9 Supply And Fixing Of 10Mm Thick Multiwall Polycarbonate Sheet Roofing With Uv Protection On Both Sides, Including Aluminum H-Profiles, U-Profiles, End Caps, Sealing Strips, And Necessary Fasteners.Including Aluminium Flat Patti Includes Mild Steel Framework Fabrication And Painting. Work Includes Cutting, Fitting, Sealing, And Cleaning. Measurement: Sqm Of Installed Area. Payment: Per Sqm For Sheets, Accessories, Framework, And Labor; Lump Sum For Miscellaneous. 10 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified. 11 M&L For Two Coats Synthetic Enamelled Paint Over One Coat Of Red Oxide Primer Incl Preparation Of New Surface Of Steel Of Any Description Any Width Or Girth Complete All As Specifed And As Directed By Engr-In-Charge. 12 Excavation In Trenches Not Exc 1.5 Mtr Wide Or N.Exc 1.5 Mtr In Depth For Pipe Line, Drains, Foundations Of Sewarage Lines Or Manholes And Like And Getting Out In Soft/Loose Soil. 13 M&L For Rcc Type A-1 (1:1.5:3) Using 20Mm Graded Aggregates For Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves,Foundation. And The Like. 14 Excavating In Post Holes Each N Exc 0.5 Cum Getting Out, Returning Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceedings 25Cm Watering And Removing Surplus Soil To Distance N Exc 50 M And Making Good Surfac In Soft/Loose Soils. 15 Providing And Laying 60Mm Thick Factory Made Chamfered Edge Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design & Pattern As In Footparth, Parks,Lawns, Drive Ways Or Light Traffic Parking Etc.,Of Required Strength, Thickness & Size/Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Compacting And Proper Embedding/ Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. 16 M&L For Providing Cement Concrete Type B-1 1:2:4 (20Mm Graded Aggregate) As In Copings Complete All As Specified And Directed By Engineer-In-Charge. 17 S & F In Repai 1000 Ltr Capacity Three Layer White Colour Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Dismantling Old Water Tank All As Specified Including Of Float Valve In Ssr Part I. 18 S & F In Repai 2000 Ltr Capacity Three Layer White Colour Rotational Moulded Polyethylene Water Storage Tanks (Cylindrical Vertical With Closed Top) Hoisted And Fixed In Position Including Dismantling Old Water Tank All As Specified Including Of Float Valve In Ssr Part I. 19 Taking Up Or Down Steel Tubing 15 Mm Bore, And Connections, Including Cleaning For Re-Fixing Or Removal To Store In Repairs Complete All As Specified. 20 S & F 15 Mm Bore, Steel Water Tubing, Medium Grade, Galvanized, With All Fitting And Fixed Complete To Walls And Ceiling Or Laid Into Floor In Repairs Complete All As Specified. 21 Taking Up Or Down Steel Tubing 20 Mm Bore, And Connections, Including Cleaning For Re-Fixing Or Removal To Store In Repairs Complete All As Specified. 22 S & F 20 Mm Bore, Steel Water Tubing, Medium Grade, Galvanized, With All Fitting And Fixed Complete To Walls And Ceiling Or Laid Into Floor In Repairs Complete All As Specified. 23 S&F Framed Mild Steel Work As In Doors Or Gates Of Angle Or Other Sections With Gusset Plates, Covring Mild Steel Plain Sheet.Rails, Braces, Tank Stagging Etc Complete Drilled For Fixing Of Steel Sheeting Or Other Covering Doors Etc To Be Prepared For Hanging Or Sliding With And Including Either Hooks And Hinges Or Steel Hanging Door Fittings(Exclusive Of Steel Sheeting Or Other Covering, Running Rails And Gurders) And Hanging Also Fastening And Complete All As Specified And Directed (Fe-410-W(Gde E-250)Quality-A). 24 S & F Expanded Metal N Exc 4 Kg Weight Per Square Meter, Cut To Length, Bent To Shape Required And Tying With And Including Annealed Mild Steel Wire Not Less Than 0.9Mm Dia Or Fixing With Galvanised Steel Staples Supplied And Fixed Complete To Wood Or Steel Members All As Specified And Directed. 25 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exceeding 25Cm In Soft/Loose Soil 26 Removing Excavated Soil Exceeding 250M But Not Exceeding 500M And Depositing Where Directed 27 M&L 75Mm Thick Pcc (1:3:6) C-1 Using 20Mm Graded Stone Aggregate As In Floor, Plinth Protection Etc. Finished Even And Smooth Without Using Extra Cement Complete All As Specified And Directed By Engineer-In-Charge. 28 M&L For Brick Work With Subclass B Bricks, Straight Or Curved On Plan Exc 6M Mean Radius Built In Cm 1:4 Complete All As Specified And Directed By Engineer-In-Charge. (4Th Story Building Including Scaffolding) 29 M&L 15Mm Thick Rendering On Wall Or Concrete Surface In Cement Mortar 1:4 Finished Even And Fair. 30 M&L Glazed Ceramic Coloured Tiles (600X300Mm) X 6-7Mm Thick On Vertical Surfaces As In Skirting/Dado, Set And Jointed With Neat Cement Slurry And Pointed In White/Coloured Cement To Match The Shade Of Tiles Laid Over 10Mm Thick Rendering In Cement Mortar 1:4. 31 S&Fsteel Work As In Posts And Struts , Flats In Fencing Including Cutting Tops To Shape As Directed, Drilling Holes, Notching For Wire, Etc.; Flat Iron Fillets (For Securing Wire Mesh Etc.) Including All Necessary Drilling, Bolting Or Riveting, Etc., And Similar Work Conforming To Fe-290 Gde E-165 Complete All As Specified And Directed. Please Enable Macros To View Boq Information
|