Work Detail
Bids Are invited for Panel Mountable Mpcb 620-El1745 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- 63Arated Curremnt- 63Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1746 - Panel Mountable Mpcbcertification Confirming To - Iec 60947Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (22-32)Arated Current- 32Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1747 - Panel Mountable Mpcbcertification Confirming To - Iec 60947Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (28-40)Arated Current- 40Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1748 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (35-45)Arated Curremnt- 45Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1749 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (18-25)Arated Curremnt- 25Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1750 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (14-20)Arated Current- 20Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1751 - Panel Mountable Mpcbcertification Confirming To - Iec 60947Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (6-10)Arated Current- 10Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1752 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (4-6.3)Arated Curremnt- 6.3Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1753 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (8-12)Arated Curremnt- 12Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1754 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (2.5-4)Arated Current- 4Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1755 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (3.5-5)Arated Current- 5Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1756 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (1.6-2.5)Arated Current- 2.5Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1757 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (0.6-1)Arated Current- 1Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El158 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (0.5-0.8)Arated Current- 0.8Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. , 620-El1759 - Panel Mountable Mpcbcertification Confirming To - Iec 60947 Part-2-2003 Latestisi Markedhandle Type- Rotary/Toggle Switchrelease Type- Overload Releasethermal Magneticbreaking Capacity- 50Ka Or Betterthermal Release Adjustment Range(A)- (0.4-0.63)Arated Current- 0.63Arated Voltage(Ac)(V)- 690Voltrated Frequency- 50 Hzutilization Category(Iec947-4-1Iec947-4-2)- Ac3test Trip Function- Yesauxillary Contact- 1 No+1 Nc. Total Quantity : 127
Contact Information
Address
KORAPUT
View Notice Now...
Fill Detail for Getting Instant Access
Instant Access