Bids Are invited for Custom Bid For Services - Wiring Of Community Hall For Installation Of Air Conditioner(Ac ) To Be Installed For Majri Area - Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 3½ Core 95 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al, Sor No 7-1-19 , Providing & Erecting Epoxy Outdoor / Indoor End Termination Kit For Lt Xlpe Armoured Cable 70 To 120 Sq Mm., With Necessary Material As Per Specification No. Cb-Jt/Lt, Sor No 7-4-10 , Supplying & Erecting Crimping Type Aluminium Lugs For Cable 95 Sq Mm Complete As Per Specification No. Cb-Cl/Al, Sor No 7-10-6 , Providing & Erecting Floor/Wall Mounting, Mccb Panel Board, With Door, Suitable For Four Pole Incoming 250A, 6 Ways Four Pole Outgoing, Up To 100 A Mccbs On Iron Frame, As Per Specification No Sw-Swr/Mccbpb. (Excluding Mccbs), Sor No 5-7-3 , Providing & Erecting 3 Pole Mccb 415V, 400A, Rated Short-Circuit Breaking Capacity 36 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Adjustable Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/ Uv/ Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, With Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure /Panel As Per Specification No. Sw-Swr/Mccb, Sor No 5-5-4 , Providing & Erecting 3 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breaking Capacity 25 Ka (Ics=100% Of Icu), Adjustable Thermal (Overload) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt/Uv/Trip Alarm Contact. Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure/Panel As Per Specification No. Sw-Swr/Mccb, Sor No 5-5-1 , Providing & Erecting Incoming And Outgoing Cable Alleys Suitable For Mccb Panel Board With Door, 250A Incoming And 6 Way Outgoing Or 400A Incoming And 4 Way Outgoing Made From Crca Sheet 1.6 Mm Thick Duly Powder Coated And Having Vertical Insulated Partition For Shielding Between The Shared Face Of Cableway And Db., Sor No 5-7-13 , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured (Strip) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall/ Trusses/Pole Or Laid In Provided Trench/ Pipe As Per Specification No. Cb-Lt/Al, Sor No 7-1-29 , Supplying, Erecting & Marking Fpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb, Sor No 5-3-13 , Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb, Sor No 5-3-3 , Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity (Icn) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr/Mcb, Sor No 5-4-10 , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 4 Sq.Mm (56 No. X 0.30 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltagegrade Up To 1.1 Kv, Sor No 1-3-16 , Ac Mcb Box With 3 Pin Top 25A (Non Sor Item) (Box And Top Pin Included) (Qutation Attached), Sor No Non Sor Mcb Box , Supplying And Laying Hms Pvc Conduit Frls Grade 25 Mm Dia With Necessary Accessories In Rcc Work/False Ceiling/False Flooring As Per Specification No. Wg-Ma/Cc., Sor No 1-1-10 , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 75 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete., Sor No 7-6-10 , Making Cement Concrete Foundation In 1:3:6 Cement Concrete, (20 To 25) Mm. Stone Metal Duly Plastered With Necessary Curing For Complete. (Pole Muffing Or Any Other Purpose)., Sor No 16-3-7 , Supplying And Erecting Single Pole And Neutral Distribution Board (Spndb), With 2 Ways For Incoming And 6 Ways (6 Poles) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr/Mcbdb, Sor No 5-4-8
|