Tender for Supply/Fixing Of Nr/Sluice Valves, Foot Valves , Submersible Starters, Led Street/ Flood Light, Special Repairing Of Electromechanical Components Installed In Raw Water P/Plant Nonihat And Boosting P/Plant Jarmundi Unit And Operational & Maintenance Work With Supply/Fixing Of Spare Items For Urban Water Supply Scheme Basukinath During Shrawani Mela-2026 , Raw Water P/Plant Nonihat , Cost Towards Supply/Fixing Of 150Mm Dia. Sluice Valve -1 No. Double Flanged Type (Flanged Type) As Per Sample Isi Marked And 6 Kg Tested Pressure Reputed Make With Nut-Bolts ½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , Cost Towards Supply/Fixing Of 150Mm Dia. Nr Valve -1 No. Double Flanged Type As Per Sample Isi Marked And 6 Kg Tested Pressure Reputed Make With Nut-Bolts-½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , Supply/Fixing Of 90 Watt Led Flood Lighting Luminaire With Pressure Die Cast Housing And Toughened Glass Cover , Operating Voltage Range 100V-270V Ac With Structure, Stand, Clamp, Tee, Wires And Switches Etc. All Complete. , C/W P/Plant Basukinath- Jarmundi Unit , Cost Towards Supply/Fixing Of 100 Dia. Sluice Valve -1 No. Double Flanged Type (Flanged Type) As Per Sample Isi Marked And 6 Kg Tested Pressure Reputed Make With Nut-Bolts ½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , Cost Towards Supply/Fixing Of 100 Dia. Nr Valve -1 No. Double Flanged Type As Per Sample Isi Marked And 6 Kg Tested Pressure Reputed Make With Nut-Bolts-½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , Cost Towards Supply/Fixing Of 150 Mm Dia. Foot Valve-2 Nos.(Flanged Type) As Per Sample Isi Marked Reputed Make With Nut-Bolts ½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , C/W P/Plant Basukinath- Basukinath Unit , Cost Towards Supply/Fixing Of 80 Dia. Sluice Valve -1 No. Double Flanged Type (Flanged Type) As Per Sample Isi Marked And 6 Kg Tested Pressure Reputed Make With Nut-Bolts ½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , Cost Towards Supply/Fixing Of 80 Dia. Nr Valve -1 No. Double Flanged Type As Per Sample Isi Marked And 6 Kg Tested Pressure Reputed Make With Nut-Bolts-½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , Cost Towards Supply/Fixing Of 100 Mm Dia. Foot Valve-2 Nos.(Flanged Type) As Per Sample Isi Marked Reputed Make With Nut-Bolts ½ Kg And Rubber Insertion ½ Kg Etc. All Complete. , Hydt Based Water Supply Scheme -At W.T.P Campus , Supplying & Fitting Of 05 Hp Submersible Pump Starter. Having Suitable Contactor, Relay, On-Off Push Buttons, Voltmeter & Ampere Meter In Ss Enclosure, One Set Complete. Make-L&T/HavellS/Any Reputed Make Isi Mark. , Wtp Campus Basukinath , Supply/Fixing Of 90/100 Watt Led Street Lighting Luminaire With Pressure Die Cast Housing And Toughened Glass Cover , Operating Voltage Range 100V-270V Ac With Structure, Stand, Clamp, Tee, Wires And Switches Etc. All Complete. , Supply/Fixing Of 90/100 Watt Led Flood Lighting Luminaire With Pressure Die Cast Housing And Toughened Glass Cover , Operating Voltage Range 100V-270V Ac With Structure, Stand, Clamp, Tee, Wires And Switches Etc. All Complete Including Repairing Of Lighting Arrangements Inside And Outside Of Pump House At Raw Water P/Plant. , Raw Water P/Plant Nonihat , Supplying All Labour Tools And Tackles For Complete Opening, Dismantling Of 75 H.P., 440 Volt, 50C/S Star Delta, 3 Phase V.T. Then Changing Of Following Bearing :- (I) Ball Bearing 6212-01 No. And (Ii) Thrust Bearing-7320B As Per Sample -Skf/Nbc/Tata/ Any Isi Mark Reputed Make Repairing Of Stator And Rotor Tapping, Varnishing, Heating Re-Assembling & Testing On Full Load, And Transportation Charges Form P/Plant To Workshop And Back To The Same Etc. All Complete At P/Plant Nonihat. , Providing All Labour, Tools, Tackles And Technician For Disconnection And Taking Out 75 Hp Vt P/Set With Column Pipe From Intake Well All Complete. , Cost Towards All Labour, Tools, Tackles And Technician For Opening, Dismantling And Cleaning, Repairing And Overhauling Of 75 Hp 9 Stage Bowl Assembly Vt Pump Having Head 120 Meters, Discharge 113M3/Hr. Speed 1460 Rpm With Changing Of Following Accessories- I. C.I. Retainer Bearing (Spider Bearing)-05 Nos. Ii. Spider Cut Less Rubber Bushes-05 Nos. Iii. Lock As Per Sample. Iv. 30Mm Dia. S.S. Line Shaft-10 Ft. Each 2 Nos. V. 30Mm Dia. S.S. Line Shaft-5 Ft. Each 3 Nos. Vi. 30Mm Dia. S.S. Head Shaft-5 Ft. Each 1 No. Vii. S.S. Shaft Coupling (S.S. Socket)-6 Nos. Viii. 30Mm S.S. Shaft & Lever (S.S. Bush)-6 Nos. Ix. S. Box- Bush-01 No. X. S.S. Reducing Socket-01 No. Xi. Changing Nut Bolt Of Column Pipe Joint & Vt Pump Bowl Assembly With S.S. Nut Bolt- 10 Kg Etc. As Per Sample All Material As Per Required Reassembling The Same At Workshop, Complete Lathe Work For Line Shaft Threading, Key & Lock Making And Refitting Etc. All Complete Job. , Cost Towards Repairing Of 150 Kva Oil Cooled Servo Voltage Stabilizer Working On Three Phase Input Voltage-240 To 400 V And Output-400±1%V. Make-Power Line With Following Works- Cost Towards Disconnection And Cleaning Of Stabilizer With All Labour Tools And Tackles. , Cost Towards Supply/Fixing Of Servo Motor As Per Sample-10 Kg Each. , Cost Towards Supply/Fixing Of Panel Sensing/Control Pcb Card As Per Sample. , R.C Kit , Control Transformer. , 3 Phase Digital Voltmeter (Input/Output) As Per Sample. , Armored And Shaft. , Cost Towards Adding Of Transformer Oil. , Cost Towards Complete Servicing And Repairing Cost Of Stabilizer With All Labour, Tools And Tackles And Electrician Charges Etc. All Complete Job And Testing On Full Load. , Boosting P/Plant Basukinath (Jarmundi Unit) , Cost Towards Repairing, Overhauling And Servicing Of 60 H.P Centrifugal Pump Set Having 1450 Rpm,Head-90 Mtr And Discharge-22000Gph With Following Works- I. Complete Dismantling Of Pump Set From Base Plate And Opening & Cleaning Of Pump With All Labour, Tools And Tackles . Ii. Repairing Of Stainless Steel Pump Shaft-1 No. With Re- Metalling Of Shaft And Re-Threading, Turning And Finishing As Per Sample Ii. S.S. Shaft Sleeve As Per Sample Both Sides-2 Nos., Iii. Making & Fitting Of Check Nut-2 Nos. Iv. Re-Metalling ,Turning And Finishing Of Bearing Housing- 2 Nos., V. M/F Gland Titener As Per Sample-02 Nos., Vi. M/F Neck Ring As Per Sample; Vii. Nut-Bolt And Studs As Per Sample Viii. Supply/Fixing 6307 Ball Bearings (Skf/Nbc Make)- 02 Nos. Each, Ix. Supply/Fixing Rubber Coupling Tyre -01 No. X. Paper Packing, Gasket Etc. Complete Re-Assembling And Overhauling Of Pump, Installing At Site With All Labour, Tools & Tackles And Testing On Full Load With Transportation Charge Up & Down Etc. Including The Deduction Of Scrap Materials All Complete At Clear Water P/Plant Basukinath. , Shiv Ganga Pound Raw Water Filling And Other P/Plant , Operational Cost Of Urban Water Supply Scheme Basukinath-Shrawani Mela- 2026 , 18% Gst , 1% Labour Cess
|