Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - For The Work Of Dismantling And Erection Of 220 132 Kv Line And Transformer C R Panel At 220 Kv Ss Rasara And 132 Kv Ss Ballia Under Etd Ballia; Substation, Switchyar.. - Estimate For Dismantling And Erection Of 220 Kv Transformer Relay & Control Panel Of 160 Mva,220/132 Kv Ict-Ii At 220 Kv S/S,Rasra Under Etd-Balliashifting Of 02 No 220 Kv C&R Panel From The Store To Koisk With The Help Of Manual Labour/Crane At 220 Kv S/S Rasra Alongwith Other Associated Work With All Cost Of Men,Material And T&P Etc Required For Satisfactory Completion Of Work In The Direction Of Supervising Engineer. , Dismanteling Of Existing 02 No. Ziv Make Sas Based Make 160 Mva Control & Relay Panel By Disconnecting All Control Cables, Ac Cables, Dc Cables, Ct & Pt Cables Etc. And Cutting Of Earthing Strips Including Shifting Of Dismantled Protection Pannel From Control Room To Substation Store. , Erection Of New Ashida Make 160 Mva Control & Relay Panel At Above Dismantled Place With Proper Alignment As Per Direction Of Incharge Engineer And Making Earthing By Ms Flat (25X6mm/50X6mm) With Existing Earthmat As Per Site Requirement. , Termination Of All Control Cables, Ac Cables Dc Cables, Ct & Pt Cables Etc. Alongwith Proper Ferruling And Fastning Of Cable Glands Of Actual Size Of Above Protection Pannels (Cable Glands,Lugs And Ferrules Etc. Shall Be Arranged By Contractor At His Own Cost.) All Associated Works Must Be Completed As Per Technical Specification & Schematic Drawing. , Checking Of Heathiness Of All Wires By Checking Supervision Circuit,Closing And Tripping Circuit, Alarm And Indication Circuit,Ct & Pt Circuit Etc.Complete Job In All Respect. , Estimate For Dismantling And Erection Of 132 Kv Line Feeder Panel Of 132 Kv Kasara Bay At 132 Kv S/S,Ballia Under Etd-Balliacarriage Of 132Kv Line Protection Panel From 220 Kv S/S Azamgarh To 132Kv S/S Ballia.(Distance-125 Kms) , Dismantling Of 132Kv Old And Defective Relay Distance Protection Panel Of 132Kv Kasara Bay By Disconnecting All Control Cable Ac Cabel, Dc Cable ,Ct&Pt Cable,Protection Cable Etc. And Cutting Of Earthing Strip Including Shifting Of Dismantled Distance Protection From Control Room To Substation Store. , Shifting Of 132Kv Distance Protection Panel From S/S Store To Control Room Safely & Carefully By Manual Labour At Place Instructed By Incharge Engineer ( Approximate Distance 50.00 Meter).Grouting Also To Done If Required. , Erection Of New Carried 132Kv Distance Protection Panel At Above Dismantled Place As Per Proper Alignment And Direction Of Ae/Je With Making Earthing By M.S Flat (25X6 Mm /50X6 Mm ) As Per Site Requirement. , Termination Of All Control Cable Ac Cable, Dc Cable, Ct&Pt Cable ,Protection Cable Alongwith Proper Feruling And Fastening Of Cable Glands Of Proper Size Of Above Distance Protction Panel .Cable Glands & Ferrules Etc. Shall Be Arranged By Contractor At His Own Cost.All Associated Works Must Be Completed As Per Technical Specification & Schematic Drawing. , Checking Of Healthiness Of All Wire By Checking Supervision Circuit Closoing And Tripping Circuit , Alarm And Indication Circuit , Ct&Pt Circuit Etc Complete Job In All Respect.
|