Tender for Procurement Of Solar Training Pv System In Eee Department In Ptu Under The Capital Asset Fund. , Solar Pv Training System 1. Scope Of Supply The Bidder Shall Supply, Install, Test, Commission And Demonstrate A Solar Pv Training And Research System Suitable For Conducting Experiments On Photovoltaic Power Generation, Dc-Dc Power Conversion, Battery Charging, Inverter Operation, Maximum Power Point Tracking (Mppt), System Monitoring And Performance Analysis. The System Shall Comprise The Following Functional Units: A. Power Generating Unit A.1 Solar Photovoltaic Modules Sl. No. Parameter Specification 1 Quantity 2 Nos. 2 A.1 Solar Photovoltaic Modules Panel Type Polycrystalline 3 Rated Power 40 Wp Each 4 Maximum Power Voltage (Vmp) 18 V (App) 5 Open Circuit Voltage (Voc) 22 V (App) 6 Mounting Arrangement Suitable Mounting Structure With Necessary Accessories A.2 Artificial Sunlight Sl. No. Parameter Specification 1 Lamp Type (Tube) Halogen 2 Lamp Rating 150 W Each 3 Number Of Tubes Per Panel 6 Nos. 4 Number Of Light Panels 2 Nos. B. Power Conditioning Unit B.1 Dc-Dc Converter Module The Converter Shall Support Both Automatic And Manual Operation. Automatic Mode Sl. No. Parameter Specification 1 Input Voltage 15-25 V Dc 2 Output Voltage 13.8 V Dc 3 Maximum Load Current 2 A Manual Mode Sl. No. Parameter Specification 1 Input Voltage 0-25 V Dc 2 Output Voltage Variable According To Duty Cycle 3 Gate Signal 5 V Peak-To-Peak 4 Switching Frequency 20 Khz - 80 Khz 5 Maximum Load Current 2 A 6 Converter Topology Buck Converter B.2 Single-Phase Inverter Module Sl. No. Parameter Specification 1 Inverter Type Single Phase 2 Rated Output Power 150 W 3 Input Voltage 12 V Dc 4 Output Voltage 220 V Ac C. Measurement, Protection And Load Unit C.1 Voltage, Current And Temperature Measurement System The System Shall Incorporate Suitable Digital Metering Facilities For Monitoring Electrical And Thermal Parameters. Sl. No. Parameter Measurement Range 1 Module Voltage 0-200 V Dc 2 Inverter Input Voltage 0-200 V Dc 3 Dc Load Voltage 0-200 V Dc 4 Battery Input Voltage 0-200 V Dc 5 Module Current 0-10 A Dc 6 Inverter Input Current 0-10 A Dc 7 Dc Load Current 0-2 A Dc 8 Battery Input Current 0-2 A Dc 9 Generator Ac Current 0-2 A Ac 10 Generator Ac Voltage 0-750 V Ac 11 Temperature 0-200 °C C.2 Variable Load Control Sl. No. Parameter Specification 1 Potentiometer 0-200 O, 150 W C.3 Load Bank Sl. No. Parameter Specification 1 Ac Load 5 W Cfl Lamp 2 Dc Load Led Load Bank (12 Nos. Leds, 1.5 W Each) C.4 Protection System Sl. No. Protection Location Fuse Rating 1 Ac Mains 10 A. 2 Potentiometer Circuit 1.6 A 3 Battery-1 5 A 4 Battery-2 5 A C.5 Battery Bank Sl. No. Parameter Specification 1 Battery Rating 12 V, 4.5 Ah 2 Quantity 2 Nos. D. Data Acquisition And Analysis Unit The System Shall Provide Facilities For Performance Monitoring, Data Acquisition And Mppt Analysis. Sl. No. Parameter Specification 1 Pv Voltage Terminal Module Output Voltage Monitoring (Up To 150 V Max.) 2 Pv Current Terminal Module Current Monitoring (Up To 2 A Max.) 3 Mppt Signal Access Provision For External Monitoring And Analysis 4 Software Necessary Software For Mppt Implementation And Analysis 5 Data Logging Real-Time Acquisition And Storage Of System Parameters 6 Plotting Facility Graphical Display And Analysis Of Measured Data
Contact Information
Contact Person
The HoD, EEE,PTU
Address
The HoD, EEE,PTU
View Notice Now...
Fill Detail for Getting Instant Access
Download Tender Document / Tender Notice
Dear Sir,
Warm Greetings from TenderDetail.com !!
We have received Tender Document request for the TDR No : 114825618
Tender Notice along with it's Attachments ( Tender Document / Scan Image of News Paper)
sent to your Email Address :.
Please check your email for Tender Document.