The Dispenser Pump For A Dishwasher Is Designed To Automatically Supply Detergent Or Rinse Aid To The Washing Chamber In A Given Volume Based On A Signal From The Controller, It Is A Peristaltic Dosing Pump With An Electric Drive, Operating On A Voltage Of 220–230 V, Designed For The Precise Supply Of Liquid Chemicals At A Flow Rate Of Approximately 0.5–5 L/H, Made Of Chemically Resistant Materials (Plastic, Silicone Tubes), Resistant Resistant To Detergents, Moisture And Temperatures Up To 50–60 °C, Designed For Intensive Use In Professional Dishwashers., A Solid-State Relay (125A/400Ac) Is Used In Pka Combi Steamers And Is Designed To Turn On And Off Powerful Consumers (Components, Elements) Using Low Voltage Supplied To The Control Terminals. Material: Metal. Weight: 0.124. Dimensions (L X W X H), Mm *: 60 X 45 X 32. Voltage, V: 400., Electromagnetic Water Supply Valve For The Combi Steamer Pka-20-1/1 Pp2, Abat Is Designed For Automatic Admission Of Water Into The Tank Or Chamber Humidification System Upon A Signal From The Controller, A Normally Closed (Nc) Valve With A 220–230V Coil, Designed For Operating Water Pressure Up To 6–10 Bar And Medium Temperature Up To 90–95°C, Made In A Brass Or Plastic Case With A Threaded Compound, Resistant To Steam, Detergents And High Humidity., The Heating Element For The Boiler Of The Mps-3200 Dishwasher Is Designed To Heat The Water In The Boiler To The Operating Rinsing Temperature, It Is A Tubular Electric Heating Element Made Of Stainless Steel With A Flange Mount And Terminal Leads For Connecting Power, Designed To Operate From A 380 V Network, Has A Power Of 4 Kw (Depending On The Modification Of The Boiler), Is Resistant To Water, High Temperatures Up To 90–100 ° C And Detergents, Designed For Long-Term Industrial Operation In Catering Equipment., The Flexible Pipe For The Combi Steamer Pka-20-1/1 Pp2 (Abat) Is Designed For Supplying And Distributing Steam Or Hot Air Inside The Chamber, Made Of Heat-Resistant Plastic, Designed To Operate At Temperatures Up To 250°C And Steam Pressure Up To 3–5 Bar, Resistant To Corrosion And Condensate, Ensures A Tight Connection Of The Steam Manifold With The Chamber Or Distribution Pipe. Diameter K215 1 1/4 X 50., The Electric Motor Is Designed To Drive An Industrial Meat Grinder Of The Mim-600 Type; It Ensures Rotation Of The Auger And Cutting Mechanism During Meat Processing. Motor Type: Asynchronous, Squirrel-Cage. Rated Power: 2.2–3.0 Kw. Supply Voltage: 380 V. Frequency: 50 Hz. Number Of Phases: 3 (Three-Phase). Nominal Rotation Speed: ~1500 Rpm. Rated Current: 5–7 A. Insulation Class: Not Lower Than F. Degree Of Protection: Not Lower Than Ip54. Design Features: Design: Claw (Im B3). Cooling Type: Air, Self-Ventilated (Ic411). Housing Material: Aluminum / Cast Iron. Direction Of Rotation: Reverse. Operational Characteristics: Operating Conditions: Indoors, Temperature From +5 To +40 °C. Load Resistance: Designed To Work With Variable Loads (Starting Under Load Is Allowed)., Three-Pole Circuit Breaker (3P) 16–25A. Rated Current: 16A / 20A / 25A. Rated Voltage: 380–400 V. Frequency: 50/60 Hz. Breaking Capacity: At Least 4.5–6 Ka. Trip Characteristic: Type C (Universal For Equipment). Release Type: Thermal And Electromagnetic. Mechanical Wear Resistance: At Least 10,000 Cycles. Electrical Wear Resistance: At Least 4,000 Cycles., The Temperature Regulator For The Mps-3200 Dishwasher Is Designed To Control And Maintain The Set Water Temperature In The Boiler, Ensuring The Correct Operation Of The Heating Elements, It Is A Mechanical Or Electronic Regulator With A Remote Temperature Sensor Tk-24-02-Sp9/6 100, Designed For A Control Range Of Approximately 90 °C, Operating Voltage 220–230 V, Load Switching Up To 10–16 A, Resistant To Moisture, Steam And Detergents, Installed On The Tank Body., The Start Button For The Angelo Po Dw077 Dishwasher Is Designed To Turn On And Start The Operating Cycle Of The Equipment, It Is An Electric Button With A Return Mechanism And Normally Open Contacts (No), Installed On The Control Panel Of The Machine, Designed To Operate In Voltage Control Circuits Of 24–230 V Ac Or Dc With A Rated Contact Current Of Up To 5–10 A, The Showering Device Is Designed For Pre-Washing Dishes, Kitchen Utensils, Gastronorm Containers, Cauldrons And Baking Trays Before Loading Them Into Dishwashers. Provides Removal Of Food Residues With A Jet Of Water Under Pressure, Reduces The Load On Dishwashing Equipment, And Reduces The Consumption Of Detergents And Water. Type: Pre-Wash Shower With Flexible Hose. Installation: Wall. Material: Stainless Steel Steel Aisi 304. Height: Not Less Than 1000 Mm. Hose Length: At Least 1000–1200 Mm. Presence Of A Return Spring: Required. Spray Type: Trigger (With Water Supply Fixation). Operating Pressure: 2–6 Bar. Maximum Pressure: No Less Than 8 Bar. Water Temperature: Up To +90 °C. Connection: Standard 1/2 Or 3/4., The Temperature Sensor For The Mps-3200 Pr-S Dishwasher Is Designed To Monitor The Water Temperature In The Washing Tank Or Boiler And Transmit A Signal To The Control System To Maintain A Given Washing Mode, Is Resistant To Moisture, Steam And Detergents, Provides Measurement Accuracy Of ±1–2 °C And Is Intended For Long-Term Use In A Professional Kitchen., Exhaust Heating Elements Are Designed To Heat Air Or Remove Condensate In Exhaust Systems, Are Manufactured In The Form Of Tubular Electric Heaters Made Of Stainless Steel Or Aluminum With A Protective Shell, Are Designed To Operate From A Voltage Of 220–380V And A Power Of 1 Kw, Are Installed On The Exhaust System Nozzles With Fastening Through A Thread, Are Designed For Operation At Air Temperatures Up To 300°C, Are Resistant To Humid Environments And Short-Term Peaks Temperatures., The Water Level Sensor For The Mps-3200 Pr-S Dishwasher Is Designed To Control And Maintain The Required Water Level In The Washing Tank, Providing Automatic Switching On And Off Of The Water Supply, As Well As Protecting Equipment From Overflow And Operation Without Water. With Thread On Plastic., The Stop Sensor For The Angelo Po Dw077 Dishwasher Is Designed To Determine The Position Of The Basket On The Conveyor And Signal To The Controller About The Need To Stop Or Start The Movement, It Is A Microswitch With Normally Open (No) Contacts, Designed For A Control Voltage Of 24V, Withstands High Cycling And Operation In A Humid Environment With Detergents At Temperatures Up To 50–70°C., The Thermal Switch Is Designed To Automatically Turn Off The Electrical Circuit When The Maximum Permissible Temperature Is Reached And Protect Equipment From Overheating. It Is A Bimetallic Temperature Switch With A Fixed Operating Temperature Of 100 °C, Designed For Operation In Alternating Current Circuits With Voltages Up To 250 V And Load Switching Usually Up To 10–16 A, Has A Metal Case With A Contact Group And Terminals For Connection, Is Installed On Heating Elements, Boilers, Dishwashers And Other Heating Equipment, Operates In An Ambient Temperature Range Up To +125 °C And Is Characterized By High Reliability And Multiple Operation Cycles., Thermostat For Electric Frying Pan Angelo Po 191Br2e, 85 L. The Thermostat Is Designed To Automatically Maintain The Set Temperature Of The Working Surface Of A Tiltable Electric Frying Pan With A Volume Of 85 Liters. Provides Switching On/Off Of Heating Elements (Heating Elements) Depending On The Set Temperature Conditions. Device Type: Mechanical Capillary Thermostat (Adjustable). Temperature Control Range: +50 To +300 °C. Rated Voltage: 220–250 V. Network Frequency: 50/60 Hz., Contactor In Alternating Current Networks. Type: Electromagnetic Contactor. Rated Current: 9A / 12A / 18A / 25A / 32A. Rated Voltage: 380-400 V. Control Coil Voltage: 220 V Or 380 V. Frequency: 50/60 Hz. Number Of Poles: 3P (3 Power Contacts). Number Of Auxiliary Contacts: 1No + 1Nc (Minimum). Wear Resistance: At Least 1 Million Cycles., The Electromagnetic Starter For A Dishwasher Is Designed To Turn On And Control Electric Motors Of Pumps And Other Electrical Components Of The Machine, Operates In Alternating Current Circuits With A Voltage Of Up To 380 V With A Control Coil Of 220–230 V And A Frequency Of 50 Hz, Has Three Power Contacts For Switching The Load And Auxiliary Contacts (No/Nc) For Control And Signaling Circuits, Designed For A Rated Operating Current Of 9–25 A, Designed In Heat-Resistant Housing With Screw Terminals For Connection And The Ability To Install A Thermal Relay To Protect The Motor From Overload., The Compressor For The Refrigeration Chamber Khn-11.57 Is Designed To Compress And Circulate The Refrigerant In The Cooling System And Maintain A Given Temperature For Storing Products, It Is A Hermetic Piston Compressor Operating From A Three-Phase Network 380–400 V, 50 Hz, Designed For The Use Of R404a Refrigerant, With A Cooling Capacity Of 4 Kw, Equipped With A Protection System Against Overheating And Overload And Designed For Long-Term Continuous Operation As Part Of A Refrigeration Monoblock., The Electric Pump Is Designed For Pumping Clean And Slightly Contaminated Water. Pump Type: Centrifugal, Horizontal (Monoblock). Rated Power: 2.2 Kw. Supply Voltage: 380 V. Network Frequency: 50 Hz. Number Of Phases: 3 (Three-Phase). Rated Current: ~4.5–5.5 A. Protection Class: Not Lower Than Ip54. Insulation Class: Not Lower Than F.
|