|
Tender for Installation Of 63 Kva & 100 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (56 No. Work) (Dpr N0. 137,138,141,142,143,144,145,146,147,148,149,150,151,152,153,154,155,156,157,158,159,160,161,152,163,164,165,166,167,168,169,170,172,173,174,175,176,177,178,179,180,181,182,183,184,185,186,187,188,189,190,191,192,193,194,195) , Carriage Of All Petty Material Of All 56 Estimate, (Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 63Kva/100 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Weasel Conductor, From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Lt Abc 3X120+1X95+1X16 Sqmm From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Dropper Channel (56Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 125X65 Sqmm And Febrication Of Top Channel/ Dropper Channel For Fuse Set / T-Off Channel (112Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 125X65x6 Mm And Febrication Of Base Angle For Substation 63Kva/100Kva (112Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 63 Kva/100 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Laying Of Lt Abc 3X120+1X95+1X16 Sqmm By Providing Suspension Clamp Dead End Clamp, I-Hook Etc And Completion Work Properly, As Per Respo Norms, And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60Xo.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of 11Kv. Fuse Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Lt Fuse Set Protection Unit For 100 Kva Tf With Smc Box Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of 3-Phase Distributiong Box All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Installation Of 250 Kva Additonal Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (02 No. Work) (Dpr No. 140 & 171) , Carriage Of All Petty Material Of 02 Estimate, (, Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 250 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Coper L-Piece 50X225x10 Mm (Ls) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Dropper Channel(4Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Ms Channel 125X65 Sqmm And Febrication Of Top Channel/ Dropper Channel For Fuse Set / T-Off Channel (4Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Safely Installation Of 250 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth, As Per Direction Of Site Incharge. , Laying Of Lt Pvc Cable Al 1X400 Sqmm By Porviding Al Lug And Panching With Cremping Tool Complection Work Properly, As Per Respo/Norms And As Per Direction Of Site Incharge. , Grouting & Fixing Of Stay Rods (20X1800)Mm Including All Work O Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Wrapping Of Barbed Wire On 11Kv St/Pcc Poles As Anti-Climbing Device For A Length Of 0.9Mtrs. Wire Pitch/Gap 13Mm And Fixing Upper And Lower End Keeping Lower End At A Height Of 2.75 Mtr From The Ground Complete, Including Providing & Fixing Of Lower End & Upper End Clamps Made Of M.S. Flat 40X5mm Complete With Nuts & Bolts And All Other Required Material And T&P., As Per Direction Of Site Inchargc. , Construction Of Tif Plinth Suitable For 250Kva (Size Of 2X2x 1.5 Mt.) As Per Drawing, cement concrete Work In Foundation In Ratio 1:4:8 (Cement, Sand & Brick Ballast). 1St Class Brick Work In Side Walls cement concrete Ratio Of 1:4 (Cement & Fine Sand). 12Mm Thick Plaster In Ratio 1:4 (Cement & Fine Sand). The Reinforced Cement Concrete Work On Top Of Plinth In Ratio 1:2:4 Are Duly Filling Of Brick Ballast Inside The Plinth & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction O Site Incharge. , Erection & Fixing Of 11Kv. Fuse Set On Plain Cement Concrete Pole, By Providing All Required Fixing Materials As Per Respo/Norms And As Per Direction Of Site Incharge. , Construction Of Safety Fencing (Ms) For Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50mm) 4 Sqmm Dia M.S. Gi Wire Mess Corrosion Free Made Of Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Anglen-Iron To Be Fitted On Vertical Posts. Pickets (I Required) Fitted To Rail And Gate To Facilitate Entry And Exit With Lock. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Gi Angle 75X75x6 Mm Corrosion Free. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Metalic Materilas Should Be Galvanized & Corrosion Free) , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Propviding And Intallation All Requrment For Earthing Of Neutral By Boring And Lowering Of G.I. Pipe Size 32 Mm Dia... Into The Ground Up To Water Level 80 Fit. With The Lower End Of Solid Copper Cone Approx. 225Mm Long And 750 Gm. In Weight Shall Be Provided And In Pipe As Well As Bringing Out A Continuous Copper Wire 6 Swg From The Cone Up To The Ground Surface Where It Will Bc Bolted To The Nf.S. Earth Strip For Tif Neutral Connection, The Earth Strip *Vill Be Welded To The G.L. Pipe And Neutral Earthing Support, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Capacity Increasing 10/16 Kva To 25 Kva Tf In B.Plan 2026-27 Scheme At Various Site Of Edd-Pilkhuwa, Under Edc Hapur (18 No. Work) (Dpr No. 740,741,742,743,744,745,746,747,748,749,750,751,752,771,773,833,834 & 891) , Carriage Of All Petty Material Of 18 Estimate, (Poly. Pin Insulator, Poly. Disc Insulator Etc) From Electricity Store Center, Hapur To 33/11Kv Sub-Station/Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center, Hapur/J.E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of 25 Kva Tf From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Weasel Conductor, From Electricity Store Center, Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Erection Of Single Pole Structure With Exsiting Single Pole And Making It Double Pole All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Tif Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing Norms By Providing All Made O M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, And Jumpering Etc Work, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Top Channel/Dropper Channel(36Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 125X65x6 Mm And Febrication Of Base Angle For Substation 25Kva (36Nos) Suitable For Dp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Stone Pad 300X300x75 Mm As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Safely Installation Of 25 Kva Transformer With The Help Of Crane/Manual Labour At Lt Sub-Station Double Pole/Plinth By Providing Proper Size Aluminium Long Barel Lug For Ht/Lt As Per Direction Of Site Incharge. , Safely Removal Of Old & Used 10/16 Kva Transformer With The Help Of Crane/Manual Labour From Lt Sub-Station Double Pole/Plinth And Carrige Site To Store Hapur As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2500) Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of St/Pcc Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballst) Grouting Will Be Done In The Block Of Size (450X450)Mm Xl/6Th O Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo[Drawing Norms And As Per Direction Of Site Incharge. , Providing & Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Nuts & Bolts Etc.) As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo Norms And As Per Direction Of Site Incharge. , Specification, Quantity And Price Schedule For Replacement Of 33Kv Line Jindal Nagar Jarjar Line And Feeder Bifurcation 1Ikv Feeder No- 1 Reliance Road In B.Plan 2026-27 Scheme, In The Jurisdiction Of Edd-Pilkhuwa Under Edc Hapur. (02 No. Work) (Dpr No. 70 & 16) , Carriage Of All Petty Material Of 02 Estimate From Electricity Store Center Hapur To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Carriage Of Acsr Dog Conductor Of Estimate From Je Store/Ctr/Esc Hapur To Site Of Work, Including Loading & Unloading At Both Ends, As Per Direction Of Site Incharge. , Carriage Of All Type Cable Of Estimate From Je Store/Ctr/Esc Hapur To Site Of Work, Including Loading & Unloading At Both Ends, As Per Direction Of Site Incharge. , Carriage Of Plain Cement Concrete Pole 11 Mtrs. Long From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Carriage Of Plain Cement Concrete Pole 8.5 Mtrs. Long From Electricity Store Center Hapur/J,E. Store To Site Of Work With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Lncharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 11 Mtr. Long, And Fixing Of M.S. Top & Dropper Channel, M.S. Angle, E-Bracket, 11Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Nomrs By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Jumpering Etc Work And As Per Direction Of Site Incharge. , Erection Of Double Pole Structure With All Accessories On Plain Cement Concrete Pole 8.5 Mtr. Long, Fixing Of M.S. Top & Dropper Channel, M.S. Angle, E-Bracket, 11Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Nomrs By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Jumpering Etc Work And As Per Direction Of Site Incharge. , Erection & Fixing Of Single Plain Cement Concrete Pole 8.50 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing/Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm, Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, As Per Direction Of Site Incharge. , Providing Ms Channel 100X50 Sqmm And Febrication Of Top Channel/Dropper Channel/T-Off Channel/Bracket Channel Suitable For Dp/Single Pole For Pcc/Stp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Providing Msangle 65X65x6 Mm And Febrication Of Bracket /Bracing Angle Suitable For Dp/Single Pole For Pcc/Stp As Per Respo/Drawing Norms And As Per Direction Of Site Incharge. , Erection & Fixing Of Single Plain Cement Concrete Pole 11 Mtr. Long In 11 Kv Line After Digging Of Suitable Pits Including Fixing Of Requisite Accessories As Per Respo Drawing/Norms By Providing F-Bracket Made Of M.S. Flat Of Size 50X6 Mm Holding Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts, As Per Direction Of Site Incharge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor By Providing Holding Clamp, Nut & Bolt E-Bracet If Reqired As Per Respo/Drnwing Nonns And As Per Direction Of Site Incharge , Grouting & Fixing Of Stay Rods (20Xl800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30) M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, As Per Direction Of Site Incharge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I.Wire & Earthing Lugs As Per Respo Drawing/Norms By Providing Proper Size Nuts & Bolts, As Per Direction Of Site Incharge. , Grouting Of Plain Cement Concrete Supports In cement concrete 1:4:8 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 33 Kv 3X300 Sq.Mm Xlpe Cable And Lt Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11 Kv Cable Jointing Kit 3X185 Sqmm, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , Making And Fixing Of Side Breckit By Ms. Channel, Ms Angle By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Erecetion Of 11 Kv V-Type Crross Arm By Providing Holding Clamp & Nut Bolt As Per Respo Norms, And As Per Direction Of Site Incharge. , Providing And Trcnchless Laying (90X2=180 Mtrs. Double Circuit) Of 140/160Mm O/D Pn-4Pe-80 Pn-4 Grade Uv Stabilized Hdpe Pipe As Per Is Of 6 Meter, For Laying Of Underground Cable As Per Respo/Norms, Including Cost Of Above Hdpe Pipe, Es Per Direction Of Site Incharge. , Laying Of 11 Kv Xlpe Cable 3X185 Sqmm, Undergound (110X2=220 Mtrs. Double Circuit) Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape Al Both Ends As Per Respo/Norms And As Per Direction Of Site Incharge , Providing And Fixing Of Danger Board, Including Fixing Of All Accessories By Providing All Required Materials (Like Suitable Clamps, Nuts & Bolts Etc.) As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Barbed Wire, As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Stone Pad 300X300x75 Mm, As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Number Plate As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Pg Clamp, As Per Respo/Norms And As Per Direction Of Site Incharge. , Errection Of Brecing Set 4.3X4.3 Mtr Angle Iron 65X65x6 Mm By Providing Holding Clamp, Nut & Bolt As Per Respo/Norms And As Per Direction Of Site Incharge. , Dismantling Of Existing 33 Kv Line And Jarjar Conductor And And Bundling Same Including Carriage Of Above Material Form Site Of Work To Je Store/Esc-Hapur, With Loading And Unloading At Both Ends On Kachha Packka Road, As Per Direction Of Site Incharge. , Jumpering And Line Energisation Work Properly As Per Respo/Norms And As Per Direction Of Site Incharge.
|